Pseudomonas aeruginosa produces the rhamnolipid biosurfactants. Thin-layer chromatography detects and determines the proportion of mono- and di-rhamnolipids produced by each strain. Quantification of total rhamnolipids involves assessing rhamnose equivalents present in these biosurfactants extracted from the culture supernatants using the orcinol method.
The environmental bacterium Pseudomonas aeruginosa is an opportunistic pathogen with high antibiotic resistance that represents a health hazard. This bacterium produces high levels of biosurfactants known as rhamnolipids (RL), which are molecules with significant biotechnological value but are also associated with virulence traits. In this respect, the detection and quantification of RL may be useful for both biotechnology applications and biomedical research projects. In this article, we demonstrate step-by-step the technique to detect the production of the two forms of RL produced by P. aeruginosa using thin-layer chromatography (TLC): mono-rhamnolipids (mRL), molecules constituted by a dimer of fatty acids (mainly C10-C10) linked to one rhamnose moiety, and di-rhamnolipids (dRL), molecules constituted by a similar fatty acid dimer linked to two rhamnose moieties. Additionally, we present a method to measure the total amount of RL based on the acid hydrolysis of these biosurfactants extracted from a P. aeruginosa culture supernatant and the subsequent detection of the concentration of rhamnose that reacts with orcinol. The combination of both techniques can be used to estimate the approximate concentration of mRL and dRL produced by a specific strain, as exemplified here with the type strains PAO1 (phylogroup 1), PA14 (phylogroup 2), and PA7 (phylogroup 3).
Pseudomonas aeruginosa is an environmental bacterium and an opportunistic pathogen of great concern due to its production of virulence-associated traits and its high antibiotic resistance1,2. A characteristic secondary metabolite produced by this bacterium is the biosurfactant RL, which is produced in a coordinated manner with several virulence-associated traits such as the phenazine pyocyanin, an antibiotic with redox activity, and the protease elastase3. The tensio-active and emulsification properties of RL have been exploited in different industrial applications and are currently commercialized4.
Most P. aeruginosa strains, belonging to phylogroups 1 and 2, produce two types of RL: mRL, which consists of one rhamnose moiety linked to a fatty acid dimer mainly of 10 carbons, and dRL, which contains an additional rhamnose moiety linked to the first rhamnose4 (see Figure 1). However, it has been reported that two minor P. aeruginosa phylogroups (groups 3 and 5) only produce mRL5,6. The two types of RL contain a mixture of fatty acid dimers, which, as mentioned, are mainly C10-C10, but smaller proportions of molecules containing C12-C10, C12-C12, and C10-C12:1 dimers are also produced. The characterization of the RL congeners produced by different strains using HPLC MS/MS has been reported7,8. The methods described in this work can only differentiate between mRL and dRL but cannot be used for the characterization of the RL congeners.
P. aeruginosa and some Burkholderia species are natural producers of RL9, but the former bacterium is the most efficient producer. However, commercially used RL is currently produced in Pseudomonas putida KT2440 derivatives expressing P. aeruginosa genes to avoid the use of this opportunistic pathogen10,11. The detection and quantification of RL produced by P. aeruginosa are of great importance for studying the molecular mechanisms involved in the expression of virulence-related traits12, in the characterization of strains belonging to clades 3 or 513, and for constructing P. aeruginosa derivatives that overproduce these biosurfactants while having reduced virulence14. The production of biosurfactants by different microorganisms has been detected based on some general characteristics of these compounds, such as the collapse drop method or emulsification index15, but these methods are neither accurate nor specific16.
Here, we describe the protocol to detect mRL and dRL using the liquid extraction of total RL from the culture supernatants of different P. aeruginosa-type strains and the separation of both types of RL using TLC. In this method, the RL extracted from the culture supernatant is separated by their differential solubility in the solvents used for TLC, causing differential migration on the silica gel plate. Thus, mRL have a more rapid migration than dRL, and they can be detected as separate spots when the plates are dried and stained with α-naphthol.
The method described here for detecting mRL and dRL by TLC is based on a previously published article17, which is easy to perform and does not require expensive equipment. This method has been useful for detecting RL in various P. aeruginosa isolates13 using appropriate controls, such as a P. aeruginosa-derived mutant unable to produce RL. However, it is not the preferred method for characterizing novel biosurfactants produced by bacteria other than Pseudomonas aeruginosa due to its lack of specificity.
Additionally, a method for quantifying the rhamnose equivalents of total RL extracted from a P. aeruginosa culture supernatant is presented. This method quantifies these biosurfactants based on the reaction of orcinol with reductive sugars, resulting in a product that can be measured spectrophotometrically at 421 nm, as previously described18. Since the reaction with orcinol is not specific to rhamnose, it is important to perform this method with RL extracted from the culture supernatant that does not contain significant amounts of other sugar-containing molecules, such as lipopolysaccharides (LPS). An acidified chloroform/methanol mixture is used here for liquid extraction of RL18, but ethyl acetate can also be used, and solid-phase extraction (SPE) yields very good results19. The orcinol method described here does not require sophisticated equipment and can provide reliable results if performed with special care in preparing the analyzed samples, as discussed. To ensure proper sample preparation, it is important to include a Pseudomonas aeruginosa rhlA mutant unable to produce RL20 and to perform three biological and three technical replicates for each determination.
There has been significant controversy in the literature16,21regarding RL determination by the orcinol method, with some studies suggesting that RL production is overestimated and that the assay lacks specificity for rhamnose, potentially detecting other sugars. However, we demonstrate here that the methods described can be accurate and specific under the appropriate conditions. Furthermore, for comparison with the procedures outlined in this article, we utilize UPLC-MS/MS detection of a dRL standard and demonstrate that similar results are obtained with the orcinol method. The detailed protocol for quantifying RL using this method is included in Supplementary File 1.
These protocols are exemplified using the type strains PAO1 (phylogroup 1), PA14 (phylogroup 2), and PA7 (phylogroup 3). These strains were chosen because they are well-characterized and produce different RL profiles.
This procedure is schematized in Supplementary Figure 1. The reagents and equipment used for the study are listed in the Table of Materials.
1. Detection of mRL and dRL in culture supernatants of P. aeruginosa using TLC
2. Quantification of the total amount of RL measuring the rhamnose equivalents present in the biosurfactant
In this article, three different P. aeruginosa type strains were utilized to represent three phylogroups, each with varying RL production levels and proportions of mRL and dRL. These strains include PAO1 (a wound isolate from Australia, 195522), PA14 (a plant isolate from the USA, 197723), and PA7 (a clinical isolate from Argentina, 201024). As a negative control, the PAO1 rhlA mutant was employed, which is incapable of RL production. All strains were cultivated for 24 h in PPGAS medium, specifically designed to promote high RL levels25, at 37 °C. The PPGAS cultures were inoculated at an optical density of 0.05 at 600 nm using an LB medium26 overnight culture. Typically, P. aeruginosa strains achieve an optical density of 2 measured at 600 nm in PPGAS medium after 24 h, which roughly corresponds to 1 x 109 bacteria per mL. To collect the culture supernatants for RL detection and quantification, the cultures were centrifuged at 3,000 x g at 4 °C for 15 min, and the cell pellet was discarded. The results obtained using these two methods (Figure 2 and Figure 3) illustrate that both the types of RL produced by each strain and the quantity of their production differ among the three strains analyzed. As depicted in Figure 2, PAO1 produces approximately 30% mRL and 70% dRL, while PA14 produces an equal ratio of 50% mRL and 50% dRL, and PA7 exclusively produces mRL. This RL production profile is consistent with previous reports12,14.
Figure 3A illustrates the amount of rhamnose equivalents present in RL produced by each of these three types of strains. From the detected rhamnose amounts, it is evident that strain PA14 produces the highest amount of RL, while strain PA7 produces the lowest amount. However, these results alone cannot be used to estimate the µM concentration of RL produced by each strain. Additionally, the orcinol method alone cannot provide an approximate RL concentration, as it relies on characterizing the proportions of mRL and dRL produced by each strain of interest. Therefore, to obtain an estimate of the µM concentration of RL, the proportion of each type of RL determined in the TLC must be considered, and a standard curve with different concentrations of rhamnose should be included (Figure 3B).
The orcinol method can indeed be utilized to quantify the concentration of RL when only one type of this biosurfactant is produced. In such cases, the μM concentration of the detected rhamnose corresponds directly to the μM concentration of mRL. For dRL, since two rhamnoses are produced by the hydrolysis of each dRL molecule, the μM concentration of rhamnose detected in RL needs to be divided by 2 to obtain their μM concentration (refer to Figure 4).
However, the majority of P. aeruginosa strains produce both types of RL at varying proportions (as shown in Figure 2), making it possible to determine only an approximate concentration of the total RL. Taking this into account, we estimated RL production by each strain as follows: For the PA7 strain, since it only produces mRL, the rhamnose forming part of RL (44.6 µg/mL + 4.5 µg/mL) corresponds directly to the µM concentration (244.78), representing the concentration of this biosurfactant in the culture supernatant, as each RL molecule contains one rhamnose moiety. However, for the PAO1 strain, although the detected rhamnose concentration was 111.55 µg/mL + 11.41 µg/mL, only 30% corresponds to mRL. Therefore, 70% of the RL molecules contain two rhamnoses per molecule. To estimate the concentration of RL, the µM rhamnose concentration (612.24) was divided by 5, considering that 1/5 corresponds to the µM concentration of mRL (122.49) and 2/5 (244.89) to dRL. Thus, the approximate µM concentration of RL produced by this strain is 367.39.
For the PA14 strain, the detected rhamnose concentration was 194.39 µg/mL + 11.5 µg/mL, which was converted to the µM concentration (1,066.9) and divided by 3. The result represents the concentration of each RL type, considering that each type was produced at 50% and that dRL contains 2 rhamnoses per molecule. Thus, this strain produces 355.63 µM of mRL and the same concentration of dRL, resulting in an approximate µM concentration of RL of 711.27, almost twice as much as strain PAO1 and almost three times the concentration produced by the PA7 strain.
Figure 1: Chemical composition of main congeners of mono-rhamnolipids and di-rhamnolipids. (A) Mono-rhamnolipids. (B) Di-rhamnolipids. Please click here to view a larger version of this figure.
Figure 2: Detection of mono-rhamnolipids and di-rhamnolipids by thin-layer chromatography. (A) Picture of a TLC plate showing RL standards, and the RL produced by strains PAO1, PA14, PA7, and the PAO1 derived ΔrhlA mutant. (B) Estimation of the proportion of each RL type (mRL and dRL) in each of the samples tested in (A), using ImageJ software. Please click here to view a larger version of this figure.
Figure 3: Quantification of RL concentration using the orcinol method. (A) Rhamnose concentration (µg/mL) contained in RL extracted from the culture supernatants of PAO1 (black bar), PA14 (light gray bar), and PA7 (dark grey bar) strains. The bars denote the standard deviation. (B) The rhamnose calibration curve for the experiment shown in (A). Please click here to view a larger version of this figure.
Figure 4: Validation of the orcinol method compared with UPLC-MS/MS for dRL quantification. (A) The dRL standard was quantified using UPLC-MS/MS. (B) The orcinol method compared with rhamnose concentration expressed in mM. (C) The same mM concentration of dRL as rhamnose gives approximately twice the absorbance at 421 nm, as expected. Please click here to view a larger version of this figure.
Supplementary Figure 1: Schematic representation of the protocol. Please click here to download this File.
Supplementary File 1: Detail protocol to quantify dRL by UPLC-MS/MS. Please click here to download this File.
The most accurate method for detecting and quantifying RL is HPLC coupled with mass spectrometry (MS)7,8,27; however, it requires specialized and expensive equipment that may not be accessible to many researchers. The methods described here can be routinely performed with basic laboratory materials and equipment to detect and estimate RL concentrations, but they have some limitations, particularly their inaccuracy in determining mRL and dRL mixtures. Moreover, the preparation of the sample used for RL quantification should be carefully executed. Cultures used for RL detection and quantification should not be in the late stationary phase, as cells might be aggregated or lysed, resulting in non-homogeneous cell suspensions that could cause variability in the results obtained. Additionally, cellular debris might interfere with the orcinol method.
Accurate results can be obtained when the described protocol is performed with appropriate controls, such as a Pseudomonas aeruginosa strain unable to produce RL (like the PAO1 ΔrhlA mutant20 used in this work, Figure 2). These results are useful for characterizing different P. aeruginosa isolates12,13, genetically modifying strains to increase RL production14, or studying the molecular genetics of RL production by various P. aeruginosa isolates12.
Thus, the methods described here can be utilized to characterize Pseudomonas aeruginosa strains for their production of virulence factors and assess their biotechnological potential, especially in the early stages of investigation. It's important to note that these methods are not intended as substitutes for techniques like HPLC/MS but rather as accessible techniques for initial strain characterization and genetic manipulation of P. aeruginosa strains.
Furthermore, if the research focus is on RL production for biomedical purposes, it's crucial to acknowledge that RL production is just one of several factors produced by Pseudomonas aeruginosa. Additionally, the type of RL produced or the amount of their production is not strictly correlated with the virulence of a particular strain, as virulence is influenced by multiple factors28.
Regarding the reproducibility of the methods described here, special attention should be paid when obtaining the organic phases in both the detection of RL by TLC (step 1.6) and the measurement of RL using the orcinol method (step 2.4). Even a small amount of the other phase taken during extraction can lead to considerable variation in the results obtained. The extraction of RL from the culture supernatant is a critical step in achieving reliable and reproducible results with the orcinol method. It's crucial that when collecting the organic phase, the interphase and the liquid phase are excluded. If an ether phase is not completely dried within 3 h, it likely contains water, necessitating a new extraction.
The use of the orcinol method for RL quantification has been debated, with arguments against its accuracy and specificity. It has been claimed that RL are often overestimated, and the method is not specific as orcinol can react with different sugars, not just rhamnose. The current data demonstrate that if RL are efficiently extracted from the culture supernatant, this technique is specific, as shown by the lack of reaction when the rhlA mutant is used as a negative control. However, to provide additional evidence of the method's accuracy in detection, independently of the extraction procedure, we detected a dRL standard by UPLC-MS/MS as described previously27, and compared the results obtained with the orcinol method18 (Supplementary File 1, Figure 4A). We found, as reported18, a very good correlation between the concentration of RL measured using this method, where each μM concentration of dRL detected corresponds to approximately twice the absorbance at 421 nm as the same rhamnose μM concentration (Figure 4B,C). This control experiment clearly demonstrates the accuracy of this method for RL quantification.
However, due to the challenge of measuring the concentration of mRL and dRL mixtures with the orcinol method, most publications report the results as rhamnose equivalents in RL. This value may not have a direct correlation with the actual RL concentration, as illustrated in the examples presented here, but nonetheless, it serves as a useful means of comparing RL quantities under different conditions, especially when using the same P. aeruginosa strain.
An alternative method for mRL and dRL quantification has been reported, which is based on the solubilization of the hydrophobic dye Victoria Pure Blue BO, commonly used in ballpoint pens29. This method is quick and inexpensive. However, this protocol was developed to quantify the heterologous production of RL by P. putida and is not feasible for use with RL produced by P. aeruginosa, as the expression of the blue toxin pyocyanin interferes with this method.
In summary, the methods described here offer a viable alternative for the detection and quantification of RL produced by P. aeruginosa that do not require sophisticated and expensive equipment. They provide a practical approach for researchers to assess RL production in a variety of experimental settings.
The authors have nothing to disclose.
The laboratory of GSCh is supported in part by grant IN201222 from Programa de Apoyo a Proyectos de Investigación e Innovación Tecnológica (PAPIIT), Dirección General de Asuntos del Personal Académico -UNAM.
1-NAPHTHOL | SIGMA-ALDRICH | 70442 | |
ACETIC ACID | J.T. BAKER | 9508-02 | |
CENTRIFUGE | For centrifuging tubes 1.5 mL and 50 mL | ||
CHLOROFORM | J.T. BAKER | 9180-02 | |
DRYING OVEN | |||
ETHER | J.T. BAKER | 9244-02 | |
GLASS PIPETTE | SIGMA-ALDRICH | CLS706510 | |
HYDROCHLORIC ACID | J.T. BAKER | 5622-02 | |
LB | |||
L-RHAMNOSE MONOHYDRATE | SIGMA-ALDRICH | R-3875 | |
METHANOL | J.T. BAKER | 9049-02 | |
ORCINOL MONOHYDRATE | SIGMA-ALDRICH | O1875 | |
PPGAS Broth | Tris HCL (0.12M), Potassium Chloride ( 0.02M) Ammonium Chloride (0.02M), Peptone (1%), pH 7.4 Autoclaved. Add Glucose (5%) and Magnesium Sulfate (0.0016M) | ||
QUARTZ CELL (CUVETTE) | SIGMA-ALDRICH | Z276669 | |
RECTANGULAR TLC DEVELOPING TANK | FISHER SCIENTIFIC | K4161801020 | |
RHAMNOLIPIDS | SIGMA-ALDRICH | R-90 | |
SPECTROPHOTOMETER | VIS | ||
SPRAYER | SIGMA-ALDRICH | Z529710-1EA | |
SULFURIC ACID | J.T. BAKER | 9681-02 | |
TES TUBES 5mL | CORNING | 352002 | |
TLC SILICA GEL 60 F254 | MERCK | 1.05554.0001 | |
WATER BATH | > 80 °C |