Membrane reactors enable hydrogenation in ambient conditions without direct H2 input. We can track the hydrogen production and utilization in these systems using atmospheric mass spectrometry (atm-MS) and gas chromatography mass spectrometry (GC-MS).
Industrial hydrogenation consumes ~11 Mt of fossil-derived H2 gas yearly. Our group invented a membrane reactor to bypass the need to use H2 gas for hydrogenation chemistry. The membrane reactor sources hydrogen from water and drives reactions using renewable electricity. In this reactor, a thin piece of Pd separates an electrochemical hydrogen production compartment from a chemical hydrogenation compartment. The Pd in the membrane reactor acts as (i) a hydrogen-selective membrane, (ii) a cathode, and (iii) a catalyst for hydrogenation. Herein, we report the use of atmospheric mass spectrometry (atm-MS) and gas chromatography mass spectrometry (GC-MS) to demonstrate that an applied electrochemical bias across a Pd membrane enables efficient hydrogenation without direct H2 input in a membrane reactor. With atm-MS, we measured a hydrogen permeation of 73%, which enabled the hydrogenation of propiophenone to propylbenzene with 100% selectivity, as measured by GC-MS. In contrast to conventional electrochemical hydrogenation, which is limited to low concentrations of starting material dissolved in a protic electrolyte, the physical separation of hydrogen production from utilization in the membrane reactor enables hydrogenation in any solvent or at any concentration. The use of high concentrations and a wide range of solvents is particularly important for reactor scalability and future commercialization.
Thermochemical hydrogenation reactions are used in ~20% of all chemical synthesis1. These reactions require large quantities of H2 gas, which are usually derived from fossil fuels, temperatures between 150 °C and 600 °C, and pressures up to 200 atm2. Electrochemical hydrogenation is an appealing way to bypass these requirements and to drive hydrogenation reactions using water and renewable electricity3. For conventional electrochemical hydrogenation, an unsaturated feedstock is dissolved in a protic electrolyte in an electrochemical cell. When a potential is applied to the cell, water oxidation occurs at the anode, while hydrogenation occurs at the cathode. In this reaction setup, both electrochemical water oxidation and chemical hydrogenation occur in the same reaction environment. The organic substrate is dissolved in a protic electrolyte to enable both electrochemical water splitting and hydrogenation of the feedstock. The proximity of these reactions can lead to byproduct formation and electrode fouling when the reactant is susceptible to nucleophilic attack or if the reactant concentration is too high (>0.25 M)4.
These challenges prompted our group to explore alternative ways to electrochemically drive hydrogenation reactions5,6,7. This search resulted in the use of a Pd membrane, which is conventionally used in hydrogen gas separation8. We use it as an electrode for water electrolysis on the electrochemical reactor side. This novel application of a palladium membrane enables the physical separation of the site of electrochemical water oxidation from the site of chemical hydrogenation. The resulting reactor configuration has two compartments: 1) an electrochemical compartment for hydrogen production; and 2) a chemical compartment for hydrogenation (Figure 1). Protons are generated in the electrochemical compartment by applying a potential across the Pt anode and the Pd membrane, which also serves as the cathode. These protons then migrate to the Pd membrane, where they are reduced to surface-adsorbed hydrogen atoms. The electrochemical compartment can be subdivided to include an optional cation exchange membrane to facilitate this proton migration. The surface-adsorbed hydrogen atoms permeate through the interstitial octahedral sites of the Pd fcc lattice9 and emerge on the opposite face of the membrane in the hydrogenation compartment, where they react with the unsaturated bonds of a given feedstock to form hydrogenated products7,10,11,12,13,14,15,16. The Pd in the membrane reactor, therefore, acts as (i) a hydrogen-selective membrane, (ii) a cathode, and (iii) a catalyst for hydrogenation.
Figure 1: Hydrogenation in a membrane reactor. Water oxidation at the anode produces protons, which are reduced on the palladium cathode. H permeates through the Pd membrane and reacts with propiophenone to form propylbenzene. Hydrogen evolution is a competing reaction that can occur on either side of the palladium membrane. For atmospheric mass-spectrometry, no chemical feedstock is used, necessitating H to leave the reactor in the form of H2 gas in either the electrochemical or hydrogenation compartments. Please click here to view a larger version of this figure.
The membrane reactor is assembled by sandwiching a Pd membrane between the anode and cathode compartments of an electrochemical H-cell12. Chemical-resistant O-rings are used to secure the membrane into place and ensure a leak-free seal. The electrochemical compartment of the membrane reactor contains a hydrogen-rich aqueous solution. In this study, we use 1 M H2SO4 and an anode that consists of a Pt wire enveloped in a 5 cm2 piece of platinum mesh. The anode is submerged in the electrolyte solution through a hole in the top of the electrochemical compartment. The chemical hydrogenation compartment contains a solvent and hydrogenation feedstock7,10,11,12,16,17. The hole at the top of the H-cell compartment is used for sampling. The experiments shown here use 0.01 M propiophenone in ethanol as the hydrogenation feed. However, the starting material (and concentration) can be varied to fit the experimental needs. For instance, a starting material that contains a long hydrocarbon chain and an alkyne functional group may be dissolved in pentane to improve solubility11. The applied current for the reaction can be between 5 mA/cm2 and 300 mA/cm2. All reactions are carried out under ambient temperature and pressure.
Atmospheric mass spectrometry (atm-MS) is used to measure the percent of hydrogen in the electrochemical compartment that permeates to the hydrogenation compartment11,12. This measurement is important to understand the energy inputs required for the membrane reactor, because it reveals the maximum possible hydrogen utilization (i.e., how much of the hydrogen being produced can actually be used for hydrogenation reactions). Hydrogen permeation through the Pd membrane is calculated by measuring the amount of H2 that evolves from both the electrochemical and hydrogenation compartments11,12. A permeation value of 100% means that all the hydrogen produced in the electrochemical compartment is transported through the Pd membrane to the hydrogenation compartment and then subsequently combines to form hydrogen gas. A permeation value of <100% means that hydrogen evolution occurs in the electrochemical compartment prior to permeating through the membrane. As H2 is produced from either the electrochemical or hydrogenation compartment, it enters the instrument and is ionized to H2+. The quadrupole selects fragments of m/z = +2, and the corresponding charge is measured by the detector. The plot obtained by this technique is the ionic charge over time. The ionic charge is measured for the hydrogenation compartment first, and when the signal stabilizes, the channels are changed to measure the electrochemical compartment. Hydrogen permeation is calculated by dividing the average ionic charge in the hydrogenation compartment by the total ionic charge measured in the reactor (Equation 1)11,12. To calculate hydrogen permeation, H2 from the hydrogenation and electrochemical compartments are measured separately using atm-MS.
(Eq. 1)
Gas chromatography mass spectrometry (GC-MS) is used to monitor the progress of the hydrogenation reaction12,14,15,16. To collect data for the example, the hydrogenation compartment of the reactor is filled with 0.01 M propiophenone in ethanol. By applying a potential across the Pt anode and the Pd cathode, reactive hydrogen is supplied to the hydrogenation compartment. The reactive hydrogen atoms then hydrogenate the unsaturated feedstock, and the products are quantified using GC-MS, where the sample is fragmented and ionized. By analyzing the mass of these fragments, the composition of the hydrogenation solution can be determined, and reaction rates can be calculated12,14,15,16.
1. Pd rolling
2. Pd annealing
3. Pd cleaning
4. Reactor assembly (Figure 2, left to right)
Figure 2: An image of the H-cell assembly. The electrochemical compartment contains 1 M H2SO4 electrolyte; this is where water oxidation occurs. The palladium membrane separates the two halves of the H-cell, and the gaskets provide a leak-free seal. The hydrogenation compartment contains 0.01 M propiophenone in ethanol (EtOH). Please click here to view a larger version of this figure.
5. Pd electrodeposition
6. Atm-MS reactor setup
7. Atm-MS instrument setup
8. Atm-MS software setup
9. Electrochemical hydrogenation
10. Gas chromatography-mass spectrometry
Atm-MS is used to measure the ionic current of the hydrogen that is produced in the membrane reactor. We can use these measurements to quantify how much hydrogen permeates through the Pd membrane during electrolysis. First, the hydrogen evolving from the hydrogenation compartment is measured (Figure 3, left of the dotted lines). When the signal reaches a steady state, the channel is switched to the electrochemical compartment. The H2 gas evolving from the electrochemical compartment is then measured until the signal is stable (Figure 3, right-hand side of the dotted line). The total hydrogen permeation is calculated from the average current on the hydrogenation side divided by the total average current (electrochemical + hydrogenation compartments, Equation 1). Figure 3A shows 73% hydrogen permeation. An average ionic current of 27 pA was measured in the hydrogenation compartment, while the electrochemical compartment had an average current of 10 pA. In contrast, Figure 3B shows a membrane that is very poor at permeating hydrogen; its hydrogen permeability was less than 1%.
Figure 3: Representative data of atmospheric-mass spectrometry. The plots show the ionic current corresponding to m/z = 2 versus the cycle number, where one cycle is 5 s. For both datasets, the left side of the plot (as shown by a left arrow from a dotted line) represents the hydrogen current evolving from the electrochemical compartment. The right-hand side of the plots (as shown by a right arrow from a dotted line) represents the hydrogen signal coming from the hydrogenation compartment. (A) Hydrogen permeation data for a Pd membrane where ~70% of the hydrogen evolves to the hydrogenation compartment. (B) Hydrogen permeation data for a membrane where <1% of hydrogen evolves to the hydrogenation compartment. Please click here to view a larger version of this figure.
GC-MS enables the identification and quantification of the species present during hydrogenation reactions. We show two examples of representative results for hydrogenation experiments in Figure 4. Figure 4A,C,E represents a scenario in which the Pd membrane is under an electrochemical bias (and, therefore, acts as a cathode). Figure 4B,D,F represents a scenario in which the Pd membrane is not under an electrochemical bias, and a separate Pd cathode (of the same surface area) completes the electrochemical circuit. In the first example (Figure 4C), a sharp peak at retention time (RT) 5.6 min was observed. This peak corresponds to the starting material, propiophenone (PP). As the reaction progressed, peaks at RT 5.5 min and RT 4.2 min began to form, while the PP peak diminished. These forming peaks represent 1-phenyl-1-propanol (PA) and propylbenzene (PB), respectively. We could achieve 100% selectivity toward PB in this example. In the second example (Figure 4D), the PP peak did not diminish over time, and no product peaks emerged. Moreover, this chromatogram displayed an unexpected peak at RT 2.9 min, which was attributed to an impurity.
Figure 4: Representative results for GC-MS. These results show the hydrogenation of propiophenone (PP) to 1-phenyl-1-propanol (PA) to propylbenzene (PB). Legend: PP is orange, PA is grey, and PB is blue. (A) Schematic of a hydrogenation experiment where electrochemical bias was applied to the Pd membrane.(B) Schematic of a hydrogenation experimental setup where there was no electrochemical bias on the Pd membrane. (C) GC-MS results for a 4 h hydrogenation experiment where electrochemical bias was applied to the Pd membrane. (D) GC-MS results for a 4 h hydrogenation experiment where electrochemical bias was not applied to the Pd membrane. (E) Kinetic profile of the hydrogenation solution over time during a hydrogenation reaction where electrochemical bias was applied to the Pd membrane. (F) Kinetic profile of the hydrogenation solution over time during a hydrogenation reaction where electrochemical bias was not applied to the Pd membrane. Please click here to view a larger version of this figure.
The Pd membrane enables hydrogen permeation and chemical hydrogenation. The preparation of this membrane is, therefore, important to the efficacy of the membrane reactor. The Pd membrane size, crystallography, and surface are tuned to improve the experimental results. Although Pd metal can evolve hydrogen at any thickness, the Pd membranes are rolled to 25 µm. This standardization of membrane thickness ensures that the time it takes for hydrogen to permeate through the membrane is constant for all the experiments. Moreover, the thinner the membrane, the more susceptible it is to pinhole formation. The Pd membranes are cut to be 30%-40% larger than the dimensions of the gasket used to hold it in place. Over multiple uses, the Pd membrane succumbs to hydrogen embrittlement by pinholing or tearing. This phenomenon makes the membrane crinkle and causes the membrane geometric surface area to shrink. The Pd used for the membranes must be annealed once it is prepared to the desired dimensions. This step aims to reduce crystalline imperfections, resulting in better hydrogen transport through the membrane. The surface of the Pd membrane is tuned to enhance the catalytic activity. The electrodeposition of Pd black enables a 250-fold increase in the catalytic surface area11. This increase in the surface area enables hydrogenation reactions to occur in the span of hours rather than days. Once a Pd membrane has been used for five hydrogenation reactions, it must be re-cleaned and re-electrodeposited. This cycle can be repeated until the membrane shows signs of irreversible damage (pinholes, cracks, or low/no hydrogenation activity).
Several issues may arise if the membrane reactor is not assembled with proper care. The problems that emerge are leaky cells and punctured Pd membranes. To prevent leaking and damage to the membrane, the Pd membrane is sandwiched between two gaskets. When the cell is tightened, the gaskets are gently compressed against either side of the Pd membrane so that no fluid can escape around the edges. The gaskets also prevent direct contact of the cell walls with the Pd membrane and reduce the potential for physical damage.
The success of a hydrogenation reaction in a membrane reactor depends on numerous factors. The two primary considerations are the availability of hydrogen and its reactivity. The availability of hydrogen is dependent on, but not limited to, the current density, hydrogenation catalysts, and solvents. The current density is directly related to the number of protons reduced on the electrochemical side of the Pd membrane, where higher current densities result in more hydrogen production. However, this does not always correlate to the amount of hydrogen emerging in the hydrogenation compartment. H2 evolution is a competing reaction that can occur on both the electrochemical and chemical hydrogenation sides of the Pd membrane. This reaction occurs when two hydrogen atoms recombine and desorb from the Pd membrane surface as H2 gas. To minimize the amount of hydrogen loss via this process, appropriate catalysts and solvents must be used to maximize the hydrogen availability in the hydrogenation compartment. Pd black is a catalyst that is electrodeposited onto the hydrogenation side of the Pd foil, and it increases the hydrogenation rates. The Pd electrodeposition looks black, and this indicates a high surface area. If the Pd deposition is grey in color, it means that the catalyst was poorly deposited, which can be the cause of slow hydrogenation rates or poor hydrogenation product yields. To select an appropriate and efficient solvent, the solvent must be able to coordinate with the reactive hydrogen atom to prevent H-H recombination, but it cannot coordinate excessively such that the solvent prevents the unsaturated molecules from reaching the reactive hydrogen. To troubleshoot slow hydrogenation rates, one should try increasing the current density, verifying successful Pd black deposition, and/or using a different solvent.
Atm-MS enables the quantification of gasses at very low detection limits. The mass spectrometer ionizes gaseous samples and then separates and quantifies the fragments using a quadrupole. Hydrogen gas is quantified by selectively plotting an m/z ratio of 2. This ratio represents the H2+ fragment, where the mass is 2 amu and the charge is +1. Therefore, atm-MS measures the ionic current corresponding to the ionized hydrogen. Each side of the membrane reactor must have only one opening that can be connected to the atm-MS channel. It is important that there are no gas leaks to ensure all the gas formed is measured by the instrument. To ensure that all the electrochemically formed H2 is measured, it is critical that during reactor assembly, the hydrogenation compartment is filled with the selected saturated solvent only, as well as that there is no unsaturated substrate present. If the hydrogen reacts with a substrate in the hydrogenation compartment, then that hydrogen will not be measured by atm-MS, and the permeation will be underestimated. When the membrane reactor is first connected to the atm-MS and potential is applied to the membrane reactor, it takes several hours for the H2+ ionic current to stabilize. It is best practice to connect the hydrogenation compartment to the atm-MS first and then to change the connection to the electrochemical compartment. This is because it takes longer for the H2 gas evolving in the hydrogenation compartment to equilibrate than the H2 gas from the electrochemical compartment.
The membrane reactor was designed to carry out hydrogenation reactions under ambient conditions using only electricity and water. The progress of these hydrogenation reactions can be monitored using GC-MS. Figure 4 depicts the resulting chromatograms and kinetic profiles for the hydrogenation of propiophenone in a membrane reactor under an electrochemical bias (Figure 4A,C,E) and without an electrochemical bias (Figure 4B,D,F). When the Pd membrane is under an electrochemical bias (Figure 4A), hydrogen atoms are reduced in the electrochemical compartment and permeate through the Pd membrane7,10,12. The hydrogen emerges into the hydrogenation chamber with an effective pressure that is proportional to the applied potential18. Unsaturated bonds in the hydrogenation compartment then react with this hydrogen to form saturated products. The progress of the reaction can be monitored by taking periodic samples and analyzing them using GC-MS. A typical chromatogram (Figure 4C) will have only one peak that corresponds to the selected starting material at T = 0. As the reaction progresses, the starting material peak will lose intensity, while peaks corresponding to the hydrogenated products will form and increase in intensity. The peak intensities at different time points can then be turned into a kinetic plot (Figure 4E) by calculating the relative compositions using Equation 2. To assign the product peaks, two methods can be employed: 1) database search and match; and/or 2) comparison to a standard solution. The first method involves the comparison of the measured m/z ratios (measured by MS) to a database of standard mass spectra (e.g., the National Institute of Standards and Technology) to find the best match. This method is usually built-in in GC-MS software and can be executed automatically. The second method involves running standard solutions of all the expected hydrogenation products and recording the retention times of each one. Ideally, both methods are employed to confirm experimental results. If an unexpected peak arises in the GC chromatogram (Figure 4D), it is likely due to contamination or byproduct formation. When the Pd membrane is not under an electrochemical bias (Figure 4B), there is no hydrogenation reaction. The resulting chromatogram does not display product peaks over time (Figure 4D). A similar result may arise if the catalytic properties of the Pd membrane are not tuned for a particular hydrogenation chemistry, or if the applied potential to the Pd membrane is too low. To troubleshoot this situation, different secondary catalysts can be deposited on top of the electrodeposited Pd layer19, or a greater potential can be applied to the Pd membrane.
The authors have nothing to disclose.
We are grateful to the Canadian Natural Sciences and Engineering Research Council (RGPIN-2018-06748), the Canadian Foundation for Innovation (229288), the Canadian Institute for Advanced Research (BSE-BERL-162173), and Canada Research Chairs for financial support. This research was undertaken thanks in part to funding from the Canada First Research Excellence Fund, Quantum Materials and Future Technologies Program. We thank Ben Herring at the UBC Shared Instrument Facility for assistance with the GC-MS instrument and method development. We thank Dr. Monika Stolar for contributions to the development and editing of this manuscript. Finally, we thank the entire Berlinguette Group at the University of British Columbia for their continued support and collaboration in studying the membrane reactor.
Ag/AgCl Reference Electrode | BASi research products | MW-2021 | Reference electrode |
Analytical Balance | Cole-Parmer | RK-11219-03 | Instrument |
Atmospheric Mass Spectrometer | ESS CatalySys | NA | Instrument |
Bench Power Supply | Newark | 1550 | Instrument |
Conductive Copper Foil Electrical Tape | McMaster Carr | 76555A711 | Electrochemical cell assembly |
Dichloromethane | Sigma Aldrich | 270997 | Reagent |
Electric Rolling Press with Dual Micrometer | MTI Corporation | MR100A | Equipment |
Electrochemical glass H-cell | University of British Columbia glass blowing | NA | Electrochemical cell assembly |
ESS catalysis QUADSTAR | ESS CatalySys | NA | Software |
Ethanol | Sigma Aldrich | 493511 | Reagent |
Flat Rolling Mill | Pepetolls | 18700A | Equipment |
Gas Chromatography Mass Spectrometer | Agilent | NA | Instrument |
GC-MS vial | Agilent | 5067-0205 | Vial for GC-MS |
Hexanes | Sigma Aldrich | 1.0706 | Reagent |
Hydrochloric Acid | Sigma Aldrich | 258148 | Reagent |
Hydrogen peroxide solution (30% v/v) | Sigma Aldrich | H1009 | Reagent |
Isopropyl Alcohol | Sigma Aldrich | W292907 | Reagent |
Masshunter Aquisition Software | Agilent | G1617FA | Software |
Micropipette (100 µL – 1000 µL) | Gilson | F123602 | instrument |
Micropipette (20 µL – 200 µL) | Gilson | F123601 | Instrument |
Mitutoyo Digital Micrometer | Uline | H-2780 | Instrument |
Muffle Furnace | MTI Corporation | KSL-1100X | Equipment |
Nitric acid | Sigma Aldrich | 438073 | Reagent |
Nitrogen gas | Sigma Aldrich | 608661 | Reagent |
Palladium (II) Chloride | Sigma Aldrich | 520659 | Reagent |
Pd wafer bar, 1 oz, 99.95% | Silver Gold Bull. | NA | Reagent |
Platinum Auxiliary Electrode | BASi research products | MW-1032 | Anode |
Potentiostat | Metrohm | PGSTAT302N | Instrument |
Propiophenone | Sigma Aldrich | P51605 | Reagent |
Proton Exchange Membrane, Nafion 212 | Fuel cell store | NA | Electrochemical cell assembly |
Sulfuric acid | Sigma Aldrich | 258105 | Reagent |