Here, we show how to perform intravital microscopy on post-capillary venules of the mouse cremaster muscle. Commonly applied to different models of inflammation and sepsis, particularly those induced by chemokines and cytokines, we highlight its relevance in the study of muscolopathies involving exaggerated muscular leukocyte infiltration.
Intravital microscopy (IVM) is widely used to monitor physiological and pathophysiological processes within the leukocyte recruitment cascade in vivo. The current protocol represents a practical and reproducible method to visualize the leukocyte endothelium interaction leading to leukocyte recruitment in skeletal muscle derived tissue within the intact organism of the mouse. The model is applicable to all fields of research that focus on granulocyte activation and their role in disease.
We provide a step by step protocol to guide through the method and to highlight potential pitfalls and technical difficulties. The protocol covers the following aspects: experimental settings and required material, anesthesia of the mouse, dissection of the cremaster muscle as well as tracheal and carotid cannulation, IVM recordings and offline analysis. Data formats like adherent leukocytes, rolling flux (RF) and rolling flux fraction (RFF) are explained in detail and appropriate applications are discussed. Representative results from dystrophin deficient mdx mice are provided in the results section.
IVM is a powerful tool to assess leukocyte recruitment in an in vivo setting; however, delineating for example endothelial and leukocyte function may require a combination with ex vivo setups like flow chamber experiments. Furthermore, the genetic background of animals of interest may greatly influence baseline recruitment, requiring individual fine tuning of the protocol provided. Despite its limitations, IVM may serve as a platform to readily translate in vitro findings into a living vertebrate organism.
Intravital microscopy (IVM) is a commonly applied tool in the field of leukocyte biology. Leukocyte recruitment follows a cascade of well-defined events initiated by leukocyte capture, rolling and adhesion to the endothelial wall, and finally transmigration and extravasation of leukocytes to the actual site of inflammation1. Each step is mediated and controlled by various chemokines (e.g., IL-8/CXCL8), receptors (e.g., LFA-1, Mac-1) and corresponding endothelial cell adhesion molecules (e.g., ICAM-1, VCAM-1 and E-Selectin)2,3. The interaction of different regulatory sites, controlling factors and mediators of the leukocyte recruitment cascade like receptor of advanced glycation end products (RAGE), intercellular adhesion molecule 1 (ICAM-1), C-X-C motif ligand (CXCL)1/2 and their receptor CXCR2 were uncovered using IVM4,5,6,7,8,9.
The method of IVM has been described for many different organs and tissues such as the intestine10, skin11, lymph nodes12, the embryonic yolk sack13 and others. However, the most widely studied method of IVM is the cremaster model, first described in rats14. Whilst still used in rats15, the method is nowadays mainly applied in mice due to the high abundance of different transgenic lines. Our group has recently highlighted the potential role of cremaster IVM in the field of inflammatory muscolopathies like Duchenne Muscular Dystrophy (DMD) studying dystrophin-deficient mdx mice16. Due to its thin interwoven and easily accessible fiber composition, the cremaster muscle represents the ideal candidate muscle to be studied as a whole mount using light or fluorescent microscopy. Leukocyte recruitment and extravasation mainly take place in post-capillary venules, which can readily be identified on a continuous muscular layer in the cremaster muscle.
The advantage of in vivo imaging compared to other in vitro assays is its biological context in a living organism. At the same time, delineating cell-specific contributions to altered leukocyte recruitment may require additional in vitro models like flow chambers or endothelial assays. The combination of multiple methods will yield most convincing data. Scientists should be aware of the limitations of the cremaster model as any surgical manipulation will lead to increased leukocyte trafficking and recruitment. Hence, baseline recruitment is difficult to estimate with this method. Despite its broad application, IVM of the cremaster can be challenging and a novel setup may take time and resources to establish. We now provide an easy protocol which will help to avoid some of the common mistakes in IVM. Also, limitations will be discussed and complimentary methods will be highlighted where applicable.
IVM of the cremaster represents an ideal approach to be implemented in the field of inflammatory and infectious studies. More specifically, the cremaster model may be of high interest to scientists studying skeletal muscle biology in the context of inflammatory disease.
Animals were housed under controlled and specific pathogen-free conditions at the IBF (Interfakultäre Biomedizinische Forschungseinrichtung), Heidelberg. All the procedures described here were approved by the local IRB and the Regierungspraesidium Karlsruhe, Baden-Wuerttemberg, Germany.
1. Anesthesia administration
2. Surgical preparation of the trachea and carotid artery (optional)
3. Surgical preparation of the cremaster muscle
4. Intravital microscopy
5. Leukocyte visualization
NOTE: Adherent and rolling leukocytes can easily be seen without further visualization. To determine the center line velocity of freely moving leukocytes, perform differential staining.
6. End of experiment
NOTE: The overall estimated time to perform this protocol should be 90 – 150 minutes.
7. Offline analysis
IVM as per the provided protocol will yield unique insights into the cascade of leukocyte recruitment in skeletal muscle. The results section will focus on typical results obtained by IVM and highlight potential problems that may encounter.
The experimental setup for intravital microscopy is outlined in Figure 1. Preparation of the cremaster muscle and removal of connective tissue is crucial to obtain focused microscopic images with a uniform surface. Excess connective tissue eventually leads to blurry microscopic images (Supplemental Video 1) when performing IVM. Figure 2 shows representative microscopic images that can be obtained using IVM. First, post-capillary venules, which should be between 20-40 µm in diameter, are identified by confluence of two smaller vessels. Only adherent and rolling leukocytes can be visualized, circulating leukocytes may only be tracked in slow motion replay of recorded videos. The number of adherent leukocytes is defined as stationary leukocytes over a time of 30 seconds and expressed per mm2 of vessel surface (Figure 2). The number of rolling leukocytes passing a previously defined cross-section of the vessel is counted; rolling velocities may be obtained in offline analysis. Rolling may be expressed as rolling flux (RF = number of rolling cells over a predefined line/min) or as rolling flux fraction (RFF in % = RF/total leukocytes flux passing the vessel). RF is highly dependent on the number of circulating cells, whereas RFF is less affected by changes in white blood cell counts (WBCs). Note that in many cases leukocyte adherence and rolling are inversely related; a high number of adherent leukocytes may reduce the pool of freely circulating cells and thus dampen leukocyte rolling.
Technical challenges and potential pitfalls
The cremaster muscle encloses the testis and assembles a spherical structure. To mount the muscle onto the recording stage, a longitudinal incision is required to open the sphere. This may affect the overall microvasculature as small vessels might be severed. To avoid bias to altered blood flow, it is advisable to choose the central area for reordering. This area should neither be touched nor manipulated. Additionally, microcautery may prevent bleeding and changes in microvascular hemodynamics. The blood flow of surrounding capillaries generally provides a valuable hint if circulation is affected due to preparation within the field of interest. In general, more proximal vessels (towards the body of the mouse) tend to show better microcirculation, however image capture may be complicated by increased movement and disturbances that result from breathing of the animal.
To prevent the cremaster muscle from drying out during microscopic recording, permanent superfusion of the tissue is eminent. Insufficient or interrupted moistening will result in drying of the tissue and failure of the experiment.
Pinning of the cremaster tissue is necessary to keep it stretched and in place. To flatten the striated muscle, gentle stretching is required. Too little stretch results in uneven tissue, which complicates microscopy, excessive stretching will restrict blood flow and harm the tissue. Again capillary blood flow provides a reliable status of the overall circulatory condition of the tissue. Experience and practice is required to determine the degree of stretch when mounting the tissue.
Long preparation times will affect the overall inflammatory state of the organism and bias data. Therefore, make sure to focus on the question of interest while designing the experiment and keep preparation times as short as necessary. If no drug administration, monitor or blood tests are required a singular preparation of cremaster tissue may be sufficient.
In most settings, different experimental groups will be compared to wild type animals. It is of pivotal importance to make sure that hemodynamic and microvascular parameters are similar between experimental groups (Table 1). A multitude of parameters may affect leukocyte recruitment in vivo, including cardiac output, vessel diameter, center line velocity, wall shear rate and the number of circulating leukocytes. Table 1 displays data from two different transgenic mouse lines, the dystrophin deficient mdx mouse and the lys-eGFP mouse (expressing eGFP under the lys promoter in neutrophils and macrophages). Whereas parameters such as vessel diameter can be controlled by the investigator, centerline velocity and shear rate depend on the hemodynamics of the individual experimental group or the mouse strain. Clearly, the centerline velocity and wall shear rate are significantly different between mdx and lys-eGFP mice (Table 1) making meaningful comparison of IVM data impossible (statistical analysis by t-test with Welch’s correction, significance was set at P < 0.05). The centerline velocity is influenced by cardiac output, peripheral vascular resistance and intravasal volume. For example, a large volume of rhodamine or any other experimental substance given via the carotid catheter increases post capillary centerline velocity and inhibits leukocyte capture and rolling (Supplemental Video 2). On the contrary, cardiac failure, deep anesthesia or hypothermia may decrease post-capillary flow. Before approaching offline analysis of IVM data, requirements of data quality (for example hemodynamic parameters within physiological ranges) should be defined, in order to draw meaningful conclusions and reduce bias.
To determine the centerline velocity, freely circulating leukocytes need to be visualized. Either, fluorescent leukocytes (like in lys-eGFP mice) may be used or leukocytes must be dyed with fluorescent reagents like rhodamine (Figure 3). Rhodamine can be applied via the carotid catheter or as an i.p. injection. Since rhodamine is gradually taken up by other cell types as well, a titration of dosage and time is essential. Excess dosing and long intervals will produce significant background during microscopy.
Finally, we like to point out biological diversity of different mouse strains. Besides genetically altered strains, also generally accepted wild type strains may show physiological variance. Figure 4 compares commonly employed black 6 (C57BL/6) to black 10 (C57BL/10ScSn) mice. Black 6 mice clearly show enhanced rolling, adhesion and transmigration of leucocytes compared to black 10 mice (statistical analysis by one-way ANOVA with Tukey’s post-hoc test; significance was set at P < 0.05), even though both strains would be referred to as wild type. Therefore, correct genetic background should be considered, especially when utilizing transgenic mice. In our experimental setting, a comparison of black 6 mice and transgenic mdx mice (black 10 background) would largely conceal the enhanced inflammatory state of dystrophin deficient mdx mice over their correct black 10 wild type background (Figure 4).
Figure 1: Schematic experimental setup of IVM on cremaster muscle. After anesthesia, the trachea is cannulated and a catheter is placed in the carotid artery. The cremaster muscle is exposed and prepared for intravital microscopy on an upright microscope using either light microscopy or fluorescent microscopy. Videos are obtained for later offline analysis. Please click here to view a larger version of this figure.
Figure 2: Representative post-capillary venule segment from intravital microscopy with sequential frames. The left column shows light microscopic images, for better visualization the vessel is outlined with dotted lines. The venule is identified by confluent vessels (marked by red asterisks) and a vessel diameter of <40 µm. The right column depicts a schematic representation of the corresponding left image, showing leukocytes in red. The first four rows show sequential images of the same vessel over time. The bottom row indicates adherent leukocytes. In the schematic representation, individual leukocytes and their rolling distance are marked. In offline analysis adherence per square millimeter, rolling flux as well as rolling velocity may be calculated. Please click here to view a larger version of this figure.
Figure 3: Rolling leukocytes may be visualized by transgenic expression of fluorescent markers or by secondary staining with rhodamine. Representative microscopic images of leukocyte recruitment of eGFP leukocytes and rhodamine labeled leukocytes from n = 3 animals each. Rolling neutrophils expressing eGFP under the lys promoter from lys-eGFP transgenic mice can be directly detected by immunofluorescent microscopy (left column). Leukocytes without fluorescent makers may be stained by intravenous or intraperitoneal injection of rhodamine (right column). Notably, rhodamine is not exclusively taken up by neutrophils, giving substantially more background. Please click here to view a larger version of this figure.
Figure 4: Comparison of leukocyte recruitment in different transgenic and wild type mouse strains. (A) Rolling flux fraction, (B) adhesion and (C) transmigration of leucocytes is compared between black 6 (C57BL/6J), black 10 (C57BL/10ScSnJ) and mdx mice (C57BL/10ScSn-DmdmdxJ), shown as mean + SEM. Black 6 mice show enhanced leukocyte recruitment compared to black 10 mice. Similarly, mdx mice have greater recruitment compared to black 10, but not compared to black 6 wild type mice. This data demonstrates the importance of allocating correct genetic controls. Data from at least n = 3 animals per group. Statistical analysis by one-way ANOVA with Tukey’s post-hoc analysis. Significance was set at P < 0.05. Please click here to view a larger version of this figure.
Mouse strain | No. of mice | No. of venules | Vessel diameter | Centerline velocity | Wall shear rate | Systemic WBC |
N | n | µm | µm/s | s-1 | /µl | |
mdx | 3 | 12 | 28 ± 4 | 1150 ± 50 | 1010 ± 100 | 5200 ± 300 |
lys-eGFP | 3 | 15 | 27 ± 2 | 2220 ± 90 | 2030 ± 90 | 5800 ± 100 |
P | 0.83 | 0.0005 | 0.0016 | 0.13 |
Table 1: Relevant hemodynamic and microvascular parameters from two different transgenic mouse lines. Vessel diameter, center line velocity, wall shear rate and systemic WBCs are displayed for mdx mice lacking dystrophin and lys-eGFP mice. In this example mdx mice (C57BL/10J, black 10 background) and lys-eGFP mice (C57BL/6J, black 6 background) show statistically different centerline velocity and wall shear rate and should not be compared using IVM. Exemplary data from at least n = 3 animals per group are presented as mean ± SEM. Statistical analysis by unpaired t-test with Welch’s correction. Significance was set at P < 0.05.
Supplemental Video 1: Microscopic effect of insufficient removal of connective tissue on cremaster muscle. Please click here to view this video (Right-click to download).
Supplemental Video 2: Altered blood flow by either hypervolemia or hypotension. Please click here to view this video (Right-click to download).
IVM as a method has been widely used to study different cell types in different organs and has been extensively described and discussed19. The main aim of this study is to provide an efficient approach to set up and perform IVM in the cremaster muscle. Practicing the method will produce reliable and reproducible results. Thus, planning and standardization are key factors to master the technique. Above all, the technique is very dependent on hemodynamic and microvascular parameters, which need to be closely monitored and controlled for. As such, different hemodynamics between groups will yield misleading results.
Despite its role in studying physiological and pathological conditions, IVM alone may not fully unravel individual contribution of specific cell types to leukocyte recruitment in inflammation. To do so, other complementary methods may be combined with IVM. For example, ex vivo methods like flow chamber experiments may delineate between effects of the endothelium or the leukocyte. Also, flow chambers are excellent setups to translate rodent findings to human leukocytes, for example in newborn infants20. Further, in vitro methods like FACS or immunohistochemistry should complement IVM experiments. Each method may add specific information acquired from a controlled environment with little confounding factors.
The traumatic cremaster preparation presented here resembles physiological baseline conditions of inflammation as closely as possible. Yet, the mandatory surgical preparation itself is a stimulus of inflammation, which must be considered for interpretation. Pharmacological TNF stimulation of the cremaster tissue may provide an additional mode to boost inflammatory recruitment beyond the traumatic surgical stimulus16. Further, different mouse strains may show altered responses towards standardized stimuli. We have demonstrated that even common wild type strains may exhibit different baseline states of leukocyte recruitment. This shows the importance of assigning correct genetic controls, and establishing baseline data for new experimental groups when planning experiments. As transgenic strains are highly abundant these days, it is likely that even same strains may differ over time depending on breeding.
Taken together, IVM is a powerful tool to monitor leukocyte recruitment in the biological context of the mouse and should be accompanied with ex vivo and in vitro techniques. Further, cremaster IVM allows a variety of different modes including specific cell staining, inflammatory stimulation or pharmacological manipulation and pretreatment. As such it may serve as a platform to evaluate different pharmacological mediators and their biological effects in preclinical studies especially in the field of inflammation and more specifically in inflammatory musculopathies.
The authors have nothing to disclose.
This study was supported by the German Federal Ministry of Education and Research (BMBF) 01GL1746E as part of the PRIMAL Consortium. The authors acknowledge Britta Heckmann and Silvia Pezer for skillful technical assistance.
Material | |||
Ketanest S | Pfizer Pharma GmbH | PZN: 08509909 | anesthesia. Generic / IUPAC Name: ketamine |
Xylazine | CP-Pharma GmbH | Article-nr.: 1205 | anesthesia. Generic / IUPAC Name: xylazine (as hidrochloride) |
Saline Solution | B. Braun Melsungen | PZN 02737756 | surgical preparation. Generic / IUPAC Name: sodium chloride |
Syringe needle Omnican F | B. Braun Melsungen | REF 9161502 | surgical preparation |
Suture 6/0 USP | Resorba | REF 4217 | surgical preparation |
Polyethylene tube #10 | BD GmbH | Supplier No. 427401 | surgical preparation |
Polyethylene tube #90 | BD GmbH | Supplier No. 427421 | surgical preparation |
Rhodamine 6G | Sigma-Aldrich Chemie GmbH | CAS Number 989-38-8 | leukocyte staining. Generic / IUPAC Name: ethyl 2-[3-(ethylamino)-6-ethylimino-2,7-dimethylxanthen-9-yl]benzoate |
Setup Equipment | |||
Upright microscope | Olympus | BX51W1 | microscopy |
40-fold objective | Zeiss | Achroplan 40 × /0.80 W | microscopy |
ImSpector software | Lavision Biotec GmbH | ver. 4.0.469 | software |
ImageJ | National Institute of Health, USA | ver. 1.51j8 | software |