Here, we present a protocol to detect total cellular reactive oxygen species (ROS) using 2',7'-dichlorodihydrofluorescein diacetate (DCFH-DA). This method can visualize cellular ROS localization in adherent cells with a fluorescence microscope and quantify ROS intensity with a fluorescence plate reader. This protocol is simple, efficient and cost-effective.
Oxidative stress is an important event under both physiological and pathological conditions. In this study, we demonstrate how to quantify oxidative stress by measuring total reactive oxygen species (ROS) using 2',7'-dichlorodihydrofluorescein diacetate (DCFH-DA) staining in colorectal cancer cell lines as an example. This protocol describes detailed steps including preparation of DCFH-DA solution, incubation of cells with DCFH-DA solution, and measurement of normalized intensity. DCFH-DA staining is a simple and cost-effective way to detect ROS in cells. It can be used to measure ROS generation after chemical treatment or genetic modifications. Therefore, it is useful for determining cellular oxidative stress upon environment stress, providing clues to mechanistic studies.
Three major reactive oxygen species (ROS) produced by cellular metabolism that are of physiological meaning are superoxide anion, hydroxyl radical, and hydrogen peroxide1. At low concentrations, they participate in physiological cell processes, but at high concentrations they have adverse effects on cell signaling pathways1. Our body has developed antioxidant systems, which are effective against excessive ROS. However, oxidative stress can occur when ROS overwhelm the detoxifying ability of our body, which contributes to many pathological conditions, including inflammation, cancer, and neurodegenerative disease2,3,4. The purpose of this method is to determine total cellular ROS in adherent cells using 2',7'-dichlorodihydrofluorescein diacetate (DCFH-DA) staining. The rationale is that oxidation of DCFH-DA to 2’-7’dichlorofluorescein (DCF) has been used extensively for total ROS detection including hydroxyl radicals (•OH) and nitrogen dioxide (•NO2). Mechanistically, DCFH-DA is taken up by cells where cellular esterase cleaves off the acetyl groups, resulting in DCFH. Oxidation of DCFH by ROS converts the molecule to DCF, which emits green fluorescence at an excitation wavelength of 485 nm and an emission wavelength of 530 nm. Compared with detection of fluorescence with flow cytometry and other alternative methods5, advantages of this method using a fluorescence microscope and a plate reader are that it produces clearly visible fluorescent images, and is easy to perform, efficient and cost-effective. This method has been widely used to detect cellular ROS for studying various conditions6,7,8. This protocol is used for detecting total ROS in adherent cells. Using this method to detect ROS in suspension cells may need some modifications.
1. Cell seeding
2. Preparation of the DCFH-DA solution
3. DCFH-DA staining
4. Imaging acquisition and intensity measurement
HCT116 colorectal cancer cells were treated with 100 µM FS or 10 µM DOX to induce oxidative stress7. As shown in Figure 1, green fluorescence was dramatically increased by both FS and DOX as expected. To quantify the relative intensity change, the cells were lysed after taking images and normalized with protein concentrations. The quantified fluorescence intensity was significantly increased by FS or DOX in HCT116 cells.
Figure 1: Iron treatment increases ROS in colorectal cancer cells. Representative fluorescent images taken by a fluorescence microscope and intensity quantification by a fluorescence microplate reader for 2',7'-dichlorodihydrofluorescein diacetate (DCFH-DA) staining in HCT116 cells after untreated control (Ctrl), (A) 100 µM ferrous sulfate (FS) or (B) 10 µM doxorubicin (DOX) treatment for 24 h. Scale bar = 400 µm. * = p < 0.05; *** = p < 0.001. Please click here to view a larger version of this figure.
The experimental protocol described here is easily reproducible to measure cellular total ROS. The critical steps include making DCFH-DA solution fresh and avoiding light exposure, minimizing cell status disturbance and extensive PBS washing right before taking images. For the preparation of DCFH-DA working solution, the stock solution should be added into pre-warmed DMEM right before adding into the 24 well plate. The reason is that old solutions that generate high background fluorescence or light exposure will lead to photobleaching. Most studies use 1x PBS or 1x Hanks' balanced salt solution (HBSS) to dilute DCFH-DA and use it as reaction buffer10. However, when using HCT116 and RKO, dilution of DCFH-DA stock solution with PBS and fetal bovine serum free DMEM generated high background signal even in untreated cell. This may be due to cell status disturbance. In addition, the DCFH-DA working solution should be added slowly along the well wall. Disturbance of cell status will generate high fluorescence signal compared to the undisturbed nearby area. It is also critical to wash at least twice with PBS before taking images to reduce auto-fluorescence of the phenol containing DMEM. Phenol-free DMEM may be a better choice but we show here that PBS washing was sufficient to minimize auto-fluorescence. As shown in Figure 1, even in untreated control groups two different batches of experiments could result in different representative images. To control experimental variations, we recommend treating cells with diluted DCFH-DA working solution (as in the protocol) instead of adding stock solution directly onto the cells. Also, images should be taken in fields with similar cell densities and the same exposure time. Finally, it is important to perform experiments on all comparison groups at the same time.
Due to the significance of ROS, specific ROS detection, in addition to total ROS detection, has also been developed. For example, cellular production of superoxide can be detected by dihydroethidium, which upon oxidation results in hydroxylation at the 2-position to form 2-hydroxyethidium. As 2-hydroxyethidium intercalates into cellular DNA, red fluorescence with excitation and emission wavelengths of 535 nm and 635 nm, respectively, can be observed. Mitochondrial superoxide can be visualized with the MitoSOX reagent, a cationic derivative of dihydroethidium that enters live cells and specifically targets mitochondria. The oxidation product of Mitosox which generates red fluorescence can intercalates into mitochondrial DNA. Chemoselective fluorescent naphthylimide peroxide probe was developed for H2O2 detection11. In addition, detection of hydroxyl radicals using fluorescence spectrophotometry was also reported12.
In summary, here we described a simple and optimized protocol for detecting cellular total ROS using cost-effective DCFH-DA staining.
The authors have nothing to disclose.
This work was supported in part by the National Institutes of Health (K01DK114390), a Research Scholar Grant from the American Cancer Society (RSG-18-050-01-NEC), a Research Pilot Project Grant from University of New Mexico Environmental Health Signature Program and Superfund (P42 ES025589), a Shared Resources Pilot Project Award and a Research Program Support Pilot Project Award from UNM comprehensive cancer center (P30CA118100), and a new investigator award from the Dedicated Health Research Funds at the University of New Mexico School of Medicine.
2',7'-Dichlorofluorescein diacetate | Cayman Chemical, Ann Arbor, MI | 20656 | |
Doxorubicin hydrochloride | TCI America, Portland, OR | D4193-25MG | |
Dulbecco's Modified Eagle Medium | Corning, Corning, NY | 45000-304 | |
Ferrous Sulfate Heptahydrate | VWR, Radnor, PA | 97061-542 | |
Invitrogen EVOS FL Auto Imaging System | Thermo Fisher Scientific Waltham, MA | AMAFD1000 | or any other fluorescence microscope |
Protein assay Bradford solution | Bio-Rad, Hercules, CA | 5000001 | |
SpectraMax M2 Microplate Reader | Molecular Devices, Radnor, PA | 89429-532 | or any other fluorescence microplate reader |