This manuscript presents protocols for the application of novel genetically encoded nitric oxide (NO•) probes (geNOps) to monitor single cell NO• fluctuations in real-time using fluorescence microscopy. The Ca2+-triggered NO• formation on the level of individual endothelial cells was visualized by combining geNOps with a chemical Ca2+ sensor.
Nitric Oxide (NO•) is a small radical, which mediates multiple important cellular functions in mammals, bacteria and plants. Despite the existence of a large number of methods for detecting NO• in vivo and in vitro, the real-time monitoring of NO• at the single-cell level is very challenging. The physiological or pathological effects of NO• are determined by the actual concentration and dwell time of this radical. Accordingly, methods that allow the single-cell detection of NO• are highly desirable. Recently, we expanded the pallet of NO• indicators by introducing single fluorescent protein-based genetically encoded nitric oxide (NO•) probes (geNOps) that directly respond to cellular NO• fluctuations and, hence, addresses this need. Here we demonstrate the usage of geNOps to assess intracellular NO• signals in response to two different chemical NO•-liberating molecules. Our results also confirm that freshly prepared 3-(2-hydroxy-1-methyl-2-nitrosohydrazino)-N-methyl-1-propanamine (NOC-7) has a much higher potential to evoke change in intracellular NO• levels as compared with the inorganic NO• donor sodium nitroprusside (SNP). Furthermore, dual-color live-cell imaging using the green geNOps (G-geNOp) and the chemical Ca2+ indicator fura-2 was performed to visualize the tight regulation of Ca2+-dependent NO• formation in single endothelial cells. These representative experiments demonstrate that geNOps are suitable tools to investigate the real-time generation and degradation of single-cell NO• signals in diverse experimental setups.
We have recently developed a novel class of genetically encoded fluorescent NO• probes, called the geNOps1. These sensors consist of a simply built, bacteria-derived, NO• binding domain2, which is conjugated to a distinct fluorescent protein (FP) variant3 (cyan, green or orange FP). NO• binding to the non-heme iron(II) center4 within the geNOps instantly reduces the fluorescence intensity1. Importantly, the geNOps fluorescence recovers rapidly and fully when intracellular NO• levels decline1. Accordingly, geNOps allow real-time imaging of (sub)cellular NO• fluctuations. Although the NO• sensing mechanism of geNOps remain unclear so far, they have proven to be excellent NO• reporters, and thus have the potency to open up a new era of polychromatic, quantitative NO• bioimaging with high spatial and temporal resolutions1,5. Other available fluorescent NO• probes are based on small chemical compounds, which need to be loaded into cells, and are irreversibly modified by NO•6. Additional disadvantages of NO• sensitive small fluorophores are their potential cytotoxicity and relatively low specificity which make it difficult to use them in a reliable, analytical and conclusive manner7,8,9. Although the effective usage of genetically encoded fluorescent probes requires efficient gene transfer techniques, FP-based genetically encoded sensors have emerged as indispensable tools that have revolutionized our understanding of the inner functioning of cells10,11. Before the development of the single FP-based geNOps, a Förster resonance energy transfer (FRET)-based NO• sensor, referred to as NOA-112, was constructed. Sato et al. designed this sophisticated probe that consists of two subunits of the NO•-sensitive soluble guanylate cyclase (sGC), both conjugated to FRET-based sensors reporting cyclic guanosine monophosphate (cGMP) levels12. As this probe responds to cGMP, it only indirectly senses intracellular NO• fluctuations12. Although NOA-1 responds to NO• elevations in the nano-molar range, this tool has not been used frequently so far, probably due to limitations regarding the availability and practicability of this bulky bipartite sensor.
Versatile functions of NO•, which impact fundamental biological processes have been well characterized13,14. Many studies proved that the NO• concentration within cells and subdomains determines cell fate in health and diseases14,15,16. In mammalians, NO• is mainly generated enzymatically in various cell types by the well characterized nitric oxide synthase (NOS) family17. So far, three isoforms of NOS have been described18,19,20; these are the Ca2+/calmodulin-dependent endothelial NOS (eNOS or NOS-3)18 and neuronal NOS (nNOS or NOS-1)19, and the Ca2+/calmodulin-independent constitutively active inducible NOS (iNOS or NOS-2)20. Moreover, the existence of mitochondrial NOS (mtNOS) has also been suggested21. However, mtNOS is considered as a splicing variant of nNOS, and is therefore not separately classified as an isoform21. Another isoform, apart from those in mammalian cells, is the so-called bacterial NOS (bNOS), mainly found in gram-positive bacteria22. The enzymatic production of NO• is highly controlled and depends on the availability of several cofactors such as nicotinamide adenine dinucleotide phosphate (NADPH), flavin adenine dinucleotide (FAD), tetrahydrobiopterin (BH4), molecular oxygen and L-arginine17. The cationic amino acid L-arginine is the substrate that is converted to L-citrulline upon NO• production17. In addition to the highly regulated enzymatic generation of NO•, it has been postulated that the radical can be reduced non-enzymatically from nitrite pools by mitochondria under hypoxic conditions23. Once NO• is produced within a cell, it can freely diffuse through biomembranes14,15. However, the very short half-life of this radical is mainly determined by the environmental conditions, and various pathways and chemical reactions efficiently degrade NO• levels24. Eventually, the formation, diffusion, and degradation of NO• depends on diverse environmental parameters which determine the effective concentration of the highly biologically active molecule24.
The geNOps technology allows the direct detection of (sub)cellular NO• fluctuation1 and is therefore suitable to reinvestigate, and newly discover the mechanisms responsible for the buildup and decomposition of cellular NO• signals. Here, we provide simple protocols and representative results for the usage of geNOps to visualize exogenously evoked and endogenously generated NO• profiles, on the level of individual cells. Moreover, the geNOps technology can be adapted for application in other cell model systems to study the complex patterns of NO• formation, diffusion, and degradation in response to diverse cellular stimuli and stresses.
1. Preparation of Chemical Buffers and Solutions
2. Cell Preparation
NOTE: In order to achieve uniformity in the performance of measuring nitric oxide (NO•) in single cells using geNOps, cells need to be pre-incubated with an iron(II)/vitamin C containing buffer prior to imaging experiments in order to restore Fe2+ within the NO•-binding domain of the NO•-probes. In case of EA.hy926 and HEK293 cells, incubation for 20 min with the iron(II) booster solution leads to full activation of the NO• sensors.
3. Live Cell Imaging of NO• and Ca2+ Signals in Individual Cells
4. Data Analysis
Visualization of Single-cell NO• Profiles in Response to Transiently Applied NO Donors
We used an HEK cell clone which stably expresses G-geNOp (Figure 1A), in order to visualize NO• signals on the single cell-level in response to two different NO-liberating small chemical compounds, NOC-7 and SNP. The NO• donors were consecutively applied to and removed from cells during imaging using a gravity-based perfusion system that ensured continuous flow (Figure 1B). All cells expressing G-geNOp with different intensities showed a clear reduction of fluorescence in response to NOC-7 and SNP (Figure 1C), indicating fast NO• accumulation within cells upon the addition of the NO• donors. Normalized fluorescence signals (1-F/F0) demonstrated that both NO• donors evoked homogeneous cellular NO• elevations that completely recovered upon washout of the NO•-releasing compounds (Figure 1D). However, 10 µM SNP induced only 50% of the cellular NO• signal (9.63 ± 1.05%, n = 3/38) that was reached by 10 µM NOC-7 (18.10 ± 1.20%, n = 3/38, p < 0.0001). In order to achieve equal intracellular NO• levels with both NO• donors, a concentration of 1 mM of SNP was required (Figures 1C, 1D).
Next, we tested the capacity of freshly prepared versus expired NOC-7 to elevate intracellular NO• levels in HEK cells. For this purpose, we prepared four experimental buffers containing 5 µM NOC-7. The NO• donor was either added freshly just prior to measurement, or kept within reservoirs for 1 hr, 2 hr, and 3 hr at room temperature prior to measurement. The different buffers were consecutively applied to and removed from the G-geNOp expressing cells using a perfusion system (Figure 2B). This approach unveiled the stability of aqueous NOC-7 solutions which, as expected, showed decreased capacities over time to elevate intracellular NO• levels (Figures 2A, 2C). Interestingly, NO• signals recovered significantly faster upon the removal of expired buffers, as compared to the intracellular NO• response that was evoked by fresh NOC-7 (Figure 2C), perhaps indicating adhesion of the intact NO•-liberating molecules at cellular components.
Simultaneous Visualization of Ca2+ and NO• Signals in Single Endothelial Cells
In order to study Ca2+-triggered NO• formation in endothelial cells, the commonly used endothelial immortalized cell-surrogate, EA.hy926 cell line, was transiently transfected with G-geNOp and loaded with Fura-2/am (see Protocol 2.8). Transfection yielded approximately 10% of G-geNOp positive endothelial cells (n = 6, Figure 3A), which is sufficient to record Ca2+-evoked NO• production on the level of single endothelial cells. However, we achieved nearly 100% G-geNOp positive EA.hy926 cells using an adeno-associated viral vector (n = 6; see Protocol 2.2). Prior to multichannel measurements, cells were incubated for 20 min at room temperature in storage buffer consisting L-NNA, a potent irreversible NOS-inhibitor26. Control cells were kept in the same storage buffer without L-NNA (see Protocol 1.1) (Figure 3B). Treatment of control cells with histamine, a potent inositol 1,4,5-trisphosphate (IP3)-generating agonist, instantly elevated cytosolic Ca2+ levels followed by a gradual increase of intracellular NO• until the agonist was removed (Figures 3C, 3D). Cells pre-treated with the NOS-inhibitor showed similar cytosolic Ca2+ signals, whereas the intracellular NO• level remained almost unaffected in response to histamine (Figure 3E). EA.hy926 cells expressing G-geNOp were also treated with 1 µM and 100 µM of the IP3-generating agonist ATP in order to test whether or not geNOps are suitable to monitor NO• signals in response to both low physiological and supra-physiological concentrations of an agonist (Figure 3F). In the endothelial cell line 1 µM ATP evoked a clear cytosolic NO• signal, which was approximately half of the signal obtained by 100 µM ATP (Figure 3F).
Figure 1: Intracellular NO profiles in response to different NO-liberating molecules. (A) Wide field images of HEK cells stably expressing cytosolic G-geNOp. Scale bar = 20 µm. (B) Schematic illustration of a gravity based half-automatic perfusion system for the controlled application and removal of NOC-7 and SNP. (C) Representative (out of 3 independent experiments) non-normalized single-cell fluorescence intensity traces in arbitrary units versus time of HEK cells stably expressing cytosolic G-geNOp in response to 10 µM NOC-7, 10 µM SNP, and 1 mM SNP. Black bold curve represents the average curve of 26 single-cell traces (light grey curves). Dotted black curve represents F0, which was used for normalization. (D) Normalized and inverted single traces (1-F/F0, light grey curves), and mean curve (black bold curve) over time in response to 10 µM NOC-7, 10 µM SNP, and 1 mM SNP extracted from panel C. Please click here to view a larger version of this figure.
Figure 2: Stability test of NOC-7 using stably G-geNOp expressing HEK cells. (A) Representative NO• concentration response curve over time of stably G-GeNOps expressing HEK cells upon application of fresh and old NOC-7 buffer solutions. All NOC-7 containing buffers were prepared initially with a final concentration of 5 µM using the same stock solution (50 mM). The elapse time of the respective solutions after preparation until imaging amounts to 1 hr, 2 hr, and 3 hr as indicated. (B) Schematic illustration of a gravity based half-automatic perfusion system to consecutively add and remove NOC-7 containing solutions during imaging. (C) Temporal correlations of cellular NO• signals in response to freshly prepared and old NOC-7 buffers. Please click here to view a larger version of this figure.
Figure 3: Simultaneous multichannel imaging of NO• and Ca2+ signals in single EA.hy926 cells. (A) Representative wide-field fluorescence images of EAhy.926 cells expressing G-geNOp (left panel) that are loaded with fura-2/am (middle and right panels). Scale bar = 20 µm. (B) Schematic illustration of the treatment of EAhy.926 cells with 500 µM Nω-nitro-L-arginine (L-NNA) for 20 min within a six-well plate prior to measurement. (C) Representative time course of a simultaneous record of fura-2 (excitation: 340 nm/380 nm emission: 510 nm) and G-geNOp signals (excitation: 480 nm; emission: 520 nm) in response to 100 µM histamine. As indicated histamine was removed after 3 min using a perfusion system. (D) Curves represent simultaneous recordings of cytosolic Ca2+ (fura-2 ratio signals, F340/F380 is grey solid line) and NO• (normalized and inverted curve, 1-F/F0 is green solid line) signals over time of a single fura-2/am loaded endothelial cell transiently expressing G-geNOp. Cells were stimulated with 100 µM histamine for 3 min in a Ca2+ (2 mM CaCl2) containing buffer (n = 8/3). (E) Representative simultaneously recorded Ca2+ (grey solid line) and NO• (green solid line) signals over time of an EA.hy926 cell that was pretreated with 500 µM Nω-Nitro-L-arginine (L-NNA) prior to measurement (n = 12/3). Cells were treated with 100 µM histamine in the presence of 2 mM Ca2+. (F) Average curves representing cytosolic NO• signals in response to 1 µM ATP followed by a second cell stimulation with 100 µM ATP. Bars represent mean values ± SD of maximal G-geNOp signals in response to 1 µM ATP (white bar) and 100 µM ATP (green bar) of 4 independent experiments; p < 0.001 vs. 1 µM ATP. P-value was calculated using an unpaired t-test. Please click here to view a larger version of this figure.
Since the discovery of NO• as an important signaling molecule in biology28, the specific real-time measurement of the radical in single cells, tissues and whole animals with high resolution in a feasible and reliable manner has been aspired. Here we report the application of recently developed genetically encoded fluorescent NO• probes (geNOps) that enable exact live-cell imaging of NO• signals using wide-field fluorescence microscopy1.
To circumvent elaborate and invasive transfection procedures HEK cell clone that stably expresses green fluorescent G-geNOp was used to quantify exogenously generated single-cell NO• profiles. As HEK cells normally do not produce NO• endogenously29, this cell type is suitable for the generation of a geNOp-based sensor cell line, which might be useful for many other applications in co-culture conditions with NO• producing primary cells or even in living animals30. However, in this study we demonstrate the capacity of various NO•-liberating compounds, of different concentrations and stabilities, to evoke intracellular NO• signals using the G-geNOp expressing HEK cell model. Our data revealed that the NO•-donor concentration, quality and method of application eventually determine the patterns of intracellular NO• profiles. Such information is indispensable for the in situ pharmacokinetic characterization of different NO• donors, which are indicative of several diseases. Notably, geNOps have been shown to stably respond to multiple repetitive applications of NO•-donor pulses over a very long time1. Accordingly, the experiments using NO•-liberating compounds presented herein, allow semi-quantitative conclusions regarding the various amplitudes and kinetics of respective cellular NO• signals (Figures 1 and 2).
Although the stably expressing HEK cell clone probably originates from a single cell, a broad heterogeneity of G-geNOps expression levels was observed (Figure 1). This is a common feature of stable cell clones as the transcription of the (genome-integrated) gene of interest is under the control of many factors such as diverse environmental stresses31 that influence cell growth rates32, and the cell cycle status33. The single FP-based geNOps are non-ratiometric probes and, hence, the NO•-induced loss of fluorescence intensity increases with the geNOp expression level1. Accordingly, normalization of the geNOps signals is essential for quantifying cellular NO• signals particularly in case of a comparative analysis. As shown in our recent study, a strict linear correlation between the basal fluorescence intensity of geNOps and the strength of the NO•-induced fluorescence quenching over a broad range of fluorescence intensities has been found1. This is an important feature of geNOps for absolute quantification of cellular NO• signals. As shown in Figure 1, normalization of the G-geNOps signals in response to NOC-7 and SNP revealed homogeneous NO• signals in different HEK cells from the same plate, indicating that HEK cells are not diverse with regards to their capacity to take up and degrade the NO• radical that originates from the NO• donor. In contrast, using geNOps in HeLa cells demonstrated clear heterogeneities of cellular NO• signals among different cells in response to NOC-7. These differences point to cell type-specific NO• metabolism and decomposition rates, which might have multiple implications in cell physiology and pathology, and can be uncovered using the geNOps technology.
Nevertheless, two important features of geNOps have to be considered carefully for the correct usage of the sensors and data interpretations: i) geNOps require adequate iron(II) to fully respond to NO•1 and ii) depending on the FP variant, geNOps can be pH sensitive1. Here we describe a protocol that has been found to be suitable for the nontoxic iron(II) supplementation of geNOps, which are expressed in either HEK, HeLa or EA.hy926 cells (see Protocol 2.6). While it has been demonstrated that cell treatment with iron(II)/vitamin C did not affect cell morphology, cell viability and metabolic activity of cells1, it might be essential to optimize this important step for other cell types and tissues. However, in some experimental conditions, the requirement of iron(II) loading might limit the applicability of geNOps. Notably, it has been shown that ascorbate can reduce NO•35 and ascorbate-iron(II) complexes are able to scavenge NO•36,37. Moreover, excess iron(II) and ascorbate can induce inflammatory responses39 and uncouple eNOS41. Such effects need to be considered when using the geNOps technology. It has been shown that under certain experimental conditions, the intracellular pH is affected significantly34, which has the potential to influence the geNOps fluorescence1. Notably, the cyan and green geNOps variants are relatively pH sensitive showing a decrease of fluorescence upon acidification1. Hence, acute changes of the (sub)cellular pH might simulate false NO• signals when using the pH sensitive geNOps. As suggested in our previous work, the parallel usage of NO• insensitive geNOps (geNOpsmut) as negative controls is recommended to dissect real cellular NO• signal from pH changes1. In addition cellular pH changes can be inspected using pH probes such as SypHer34.
Further, we visualized the endogenous enzymatic NO• formation in response to a physiological Ca2+-mobilizing agonist in the endothelial cell surrogate EA.hy926. The EA.hy926 cell line is a frequently used model system consistently expressing eNOS38. Use of geNOps transiently expressed in EA.hy926 cells, confirmed that IP3-mediated Ca2+ signals evoke profound NO• formation in this cell type, which was almost completely blocked by L-NNA. In order to temporally correlate Ca2+ with NO• signals, G-geNOp-expressing cells were loaded with the UV-excitable chemical Ca2+-indicator fura-2/am. The spectral separation of the Ca2+ bound and unbound fura-2 fluorescence from the G-geNOp signal can be easily achieved with commercially available filter sets40. Imaging both probes unveiled that the Ca2+-triggered enzymatic NO• formation occurs much slower compared to the cytosolic Ca2+ rise in this endothelial cell type. Similar kinetics of single-cell NO• signals in endothelial cells from bovine pulmonary artery upon cell treatment with the IP3-generating agonist bradykinin, as well as shear stresses have been reported using NOA-1, an indirect highly NO•-sensitive sensor12. Accordingly, these data emphasize that the Ca2+-evoked eNOS-derived NO• formation requires a certain starting time until the full enzymatic activity is reached. Although the kinetics of cellular NO• formation, diffusion and degradation can be extracted from other data, e.g. tension-based measurements of NO•-induced vessel relaxation26, the great benefit of fluorescent NO• probes is that they directly convert cellular NO• fluctuations into visible signals in real-time. Hence, imaging cellular NO• signals with geNOps provides high spatial and temporal resolution, and offers unique possibilities in (re)investigating the (sub)cellular NO• homeostasis. For instance, imaging eNOS shuttling42 in combination with the geNOps technology in single endothelial cells might be suitable to correlate NO• formation with the subcellular localization and translocation of the NO•-producing enzyme or other relevant proteins such as calmodulin and caveolin43.
Here we describe the practicable application of G-geNOp expressing HEK and EA.hy926 cells to visualize exogenously and endogenously generated cellular NO• signals on the single-cell level and in real-time on a conventional wide field fluorescence microscope. Our data imply that geNOps are suitable to specifically track (sub)cellular NO• dynamics under various experimental conditions using all kinds of interesting cell types.
The authors have nothing to disclose.
The authors acknowledge C.J. Edgell, Pathology Department, University of North Carolina at Chapel Hill, NC, USA for providing the EA.hy926 cells. Author E.E. is supported by Nikon Austria within the Nikon-Center of Excellence, Graz and is a fellow of the Ph.D. program in Molecular Medicine at the Medical University of Graz. The researchers are also supported by the Ph.D. program Metabolic and Cardiovascular Disease (DK-W1226) of the Medical University of Graz. This work was also funded by the FWF project P 28529-B27. Microscopic equipment is part of the Nikon-Center of Excellence, Graz that is supported by the Austrian infrastructure program 2013/2014, Nikon Austria Inc., and BioTechMed, Graz.
NaCl | Carl Roth, Karlsruhe, Germany | 3957.20 | sodium chloride |
KCl | Carl Roth, Karlsruhe, Germany | 6781.1 | potassium chloride |
CaCl2 .2H2O | Carl Roth, Karlsruhe, Germany | T885.1 | calcium chloride dihydrate |
MgCl2 .6H2O | Carl Roth, Karlsruhe, Germany | 2189.2 | magnesium chloride hexahydrate |
HEPES | Carl Roth, Karlsruhe, Germany | 9105.3 | 4-(2-Hydroxyethyl)-1-piperazineethanesulfonic acid |
NaHCO3 | Carl Roth, Karlsruhe, Germany | 8551.1 | sodium hydrogencarbonate |
KH2PO4 | Merck, Darmstadt, Germany | 104873 | potassium dihydrogen phosphate |
Na2HPO4 .2H2O | Carl Roth, Karlsruhe, Germany | 4984.1 | sodium hydrogenphosphate dihydrate |
D(+)-Glucose monohydrate | Carl Roth, Karlsruhe, Germany | 6780.1 | >99.5%; for cell culture, endotoxin free; |
EGTA | Carl Roth, Karlsruhe, Germany | 3054.2 | ethylene glycol-bis(2-aminoethylether)-N,N,N′,N′-tetraacetic acid; calcium chelating agent |
NaOH | Carl Roth, Karlsruhe, Germany | 6771.1 | sodium hydroxide |
HCl | Carl Roth, Karlsruhe, Germany | 4625.1 | hydrochloric acid, fuming, 37% (~10 N) |
DMSO | Carl Roth, Karlsruhe, Germany | 4720.1 | dimethyl sulfoxide; highly polar, aprotic organic solvent |
L-Glutamic acid hydrochloride | Sigma Aldrich, Vienna, Austria | G2128 | (S)-2-Aminoglutaric acid |
DMEM, low glucose | Sigma Aldrich, Vienna, Austria | D5523 | Dulbecco’s Modified Eagle’s Medium – low glucose; with 1000 mg/L glucose and L-glutamine, without sodium bicarbonate, powder, suitable for cell culture |
MEM Vitamin solution (100X) | Gibco/Thermo Fisher Scientific, Waltham, MA, USA | 11120037 | 100x the vitamins found in the standard Minimum Essential Medium (MEM) |
MEM Amino acids solution (50X) | Gibco/Thermo Fisher Scientific, Waltham, MA, USA | 11130036 | 50X the essential amino acids (except L-glutamine) found in the standard Minimum Essential Medium (MEM) |
Penicillin-Streptomycin (10,000 U/ml) | Gibco/Thermo Fisher Scientific, Waltham, MA, USA | 15140122.00 | antibiotics to prevent bacterial contamination of cell cultures |
Amphotericin B | Gibco/Thermo Fisher Scientific, Waltham, MA, USA | 15290026.00 | Gibco Amphotericin B contains 250 µg of amphotericin B (Fungizone) and 205 µg of sodium deoxycholate; prevents the contamination of cell cultures by yeast and multicellular fungi |
FCS | Gibco/Thermo Fisher Scientific, Waltham, MA, USA | 10270106 | Fetal Bovine Serum, qualified, E.U.-approved, South America origin |
PBS, pH 7.4 | Gibco/Thermo Fisher Scientific, Waltham, MA, USA | 10010031.00 | phosphate-buffered saline |
Fura-2 (AM) | Teflabs, Austin, TX, USA | 102 | fluorescent cytosolic calcium indicators |
Histamine dihydrochlorid | Sigma Aldrich, Vienna, Austria | H7250 | 2-(4-Imidazolyl)ethylamine dihydrochloride; IP3-generating agonist |
Nω-Nitro-L-arginine | Sigma Aldrich, Vienna, Austria | N5501 | N5-(Nitroamidino)-L-2,5-diaminopentanoic acid; L-NNA; inhibitor of nitric oxide synthase |
NOC-7 | Calbiochem/Merck, Darmstadt, Germany | 487952 | 3-(2-Hydroxy-1-methyl-2-nitrosohydrazino)-N-methyl-1-propanamine; nitric oxide (NO) donor short half-life of NO release |
Sodium nitroprusside dihydrate | Santa Cruz Biotechnology, Texas, USA | sc-203395A | sodium nitroferricyanide(III) dihydrate; nitric oxide releasing compound |
30-mm Cover slips | Karl Hecht, Sondheim v. d. Rhön, Germany | 41001130 | glass cover slips, HECHT "Assistent", size 1, round, 30-mm, (VE: 100 pcs.) |
Iron(II) booster solution | Next generation fluorescent imaging (NGFI), Graz, Austria | n.a. | Iron(II) containing physiological buffer for non toxic iron(II) loading of cells; http://www.ngfi.eu/product/ironii-booster-solution/ |
G-geNOp plasmid | Next generation fluorescent imaging (NGFI), Graz, Austria | n.a. | plasmid DNA encoding green NO sensitive probe (G-geNOp); http://www.ngfi.eu/product/g-genop/ |
G-geNOp AAV5 | Next generation fluorescent imaging (NGFI), Graz, Austria | n.a. | adenovirus encoding green NO sensitive probe (G-geNOp); http://www.ngfi.eu/product-category/genops/viral-genops-vectors/g-genop-aav5/ |
G-geNOp sensor cell line | Next generation fluorescent imaging (NGFI), Graz, Austria | n.a. | human embryonic kidney cell line (HEK293) stably expressing green NO sensitive probe (G-geNOp); http://www.ngfi.eu/product-category/genops/g-genop-sensor-cell-line/ |
HEK293A cell line | Invitrogen/Thermo Fisher Scientific, Waltham, MA, USA | R70507 | subclone of human embryonic kidney cell line (HEK293) |
EA.hy926 cell line | American Type Culture Collection (ATCC), Wesel, Germany | CRL-2922 | somatic cell hybrid clone of human umbilical vein cell line with a thioguanine-resistant clone of A549 |
TILL iMIC | Till Photonics, Graefling, Germany | n.a. | digital microscope |
Polychrome V monochromator | Till Photonics, Graefling, Germany | n.a. | ultra fast switching |
AVT Stingray F145B | Allied Vision Technologies, Stadtroda, Germany | n.a. | Versatile CCD camera with Sony ICX285 EXview HAD sensor, IEEE 1394b |
alpha Plan Fluar 40 | Zeiss, Göttingen, Germany | n.a. | x40 objective |
dichroic filters | Chroma Technology Corp, Rockingham, Vermont, USA | n.a. | GFP emitter 514/3 nm (515dcxr) |
ValveBank8 Controller | AutoMate Scientific, Inc., Berkeley, California, USA | 01-08 | programmable perfusion system control unit |
BVC control | Vacuubrand, Wertheim, Germany | 727200 | Chemistry diaphragm pump ME 1C; vacuum pump for perfusion system |
ImageJ software | NIH Image | Java image processing program inspired by NIH Image. http://imagej.net/Welcome |