Source: Fink, A. M., et al. Quantifying Acute Changes in Renal Sympathetic Nerve Activity in Response to Central Nervous System Manipulations in Anesthetized Rats. J. Vis. Exp. (2018).
This video demonstrates a technique of studying the activity of renal sympathetic nerves (RSNs) in response to changes in arterial pressure in rats. Upon attaching a pressure-sensing catheter to the femoral artery, the renal sympathetic nerves are exposed. The nerves are then lifted onto a recording electrode, and their electrical activity is recorded. Next, a vasoconstricting drug is injected to elevate blood pressure, and corresponding changes in RSN activity are monitored.
All procedures involving animal models have been reviewed by the local institutional animal care committee and the JoVE veterinary review board.
1. Create Bipolar RSNA Electrodes
2. Administer Anesthesia and Prepare Surgical Sites
3. Cannulate the Femoral Artery for Mean Arterial Pressure Monitoring
4. Position the Rat in the Stereotaxic Surgery Frame to Access the Brain
5. Isolating the Renal Sympathetic Nerves
6. Record Data
Figure 1: RSNA and BP in response to phenylephrine injection IV. The raw RSNA (A) was full-wave rectified (B); rectified crushed "zero" RSNA is shown in inset C. Non-overlapping 10 s averages (minus noise) were calculated (D). To evoke the baroreflex, 0.1 mL of phenylephrine (1 µg/mL) was injected intravenously (at arrow). The bolus infusion elicited an abrupt increase in BP and transient inhibition of RSNA. The pedunculopontine tegmentum controls renal sympathetic nerve activity and cardiorespiratory activities in Nembutal-anesthetized rats
The authors have nothing to disclose.
Stainless steel wire | A-M Systems; Sequim, WA | 791000 | RSNA electrode |
Polyethylene (PE-50) tubing | VWR; Radnor, PA | 63019-048 | RSNA electrode; vessel cannulation |
Miniature pin connector | A-M Systems; Sequim, WA | 520200 | RSNA electrode |
Crimping tool | Daniels Manufacturing Corp.; Orlando, FL | M22520 | RSNA electrode |
Connector strip | Amphenol; Clinton Township, MI | 221-2653 | RSNA electrode |
J-B Kwik Epoxy | J-B Weld, Sulphur Springs, TX | 8270 | RSNA electrode |
Silicone | Permatex; Hartford, CT | 2222 | RSNA electrode |
Heparin sodium; Injectable (10 mL vial, 1000 U/mL) | KV Veterinary Supply; David City, NE | P03466 | Venous line patency |
Phenylephrine HCl; Injectable (1 mL vial; 10 mg/mL) | ACE Surgical Supply; Brockton, MA | 950-6312 | Testing renal sympathoinhibition |
Single-hook elastic surgical stays | Harvard Apparatus; Holliston, MA | 72-2595 | Incision |
Silk surgical tape | 3M, Minneapolis, MN | 1538-0 | Secure surgical stays |
Needles, 20 G | Sigma-Aldrich; St. Louis, MO | Z192554-100EA | Vessel cannulation |
Dumont #7 curved forceps | Fine Science Tools; Foster City, CA | 11274-20 | Vessel cannulation |
5-0 silk suture ties | Braintree Scientific; Braintree, MA | SUT-S 106 | Vessel cannulation |
Delicate hemostatic forceps | Roboz Surgical Instrument Co.; Gaithersburg, MD | RS-7117 | Vessel cannulation and RSNA surgery |
Crile Hemostatic forceps | Fine Science Tools; Foster City, CA | 13004-14 | Needle bending |
Telemetry transmitter | Data Sciences International; Minneapolis, MN | PA-10 | Mean arterial pressure monitoring (telemetry) |
Re-gel syringe | Data Sciences International; Minneapolis, MN | 276-0038-001 | Transmitter reuse (telemetry) |
Disposable pressure transducer | Transpac; San Clemente, CA | MI-1224 | Mean arterial pressure monitoring |
Clear-Cuff pressure infuser | MILA International Inc.; Florence, KY | 2281339 | Mean arterial pressure monitoring |
Vessel cannulation forceps | Fine Science Tools; Foster City, CA | 00574-11 | Catheter insertion |
Black monofilament nylon 4-0 suture on reverse cutting needle | McKesson Medical-Surgical; San Francisco, CA | S661GX | Secure telemetry transmitter |
Telemetry receiver | Data Sciences International; Minneapolis, MN | RPC-1 | Mean arterial pressure monitoring (telemetry) |
LabChart Pro (software), PowerLab (acquisition hardware) | AD Instruments; Colorado Springs, CO | ML846, MX2 matrix 2.0 (Compatible with Data Science International telemetry) | 3 options for software/acquisition hardware |
SciWorks (software), DataWave (acquisition hardware) | DataWave Technologies, Loveland, CO | N/A | |
Spike 2 (software), Micro1401-3 | Cambridge Electronic Design Ltd., London UK | 1401-3 | |
Micro-drill | Roboz Surgical Instrument Co.; Gaithersburg, MD | RS-6300 | CNS surgery |
Stereotaxic surgery frame | Stoelting; Wood Dale, IL | 51600 | CNS surgery |
Microelectrode amplifier with 10X pre-amplifier | A-M Systems; Sequim, WA | 1800-2 | RSNA recording |
Retractors | Fine Science Tools; Foster City, CA | 17009-07 | RSNA recording |
Micro-dissecting tweezers | Fine Science Tools; Foster City, CA | 11251-10 | RSNA recording |
Micro-hook | Fine Science Tools; Foster City, CA | 10064-14 | RSNA recording |
Mineral oil | Fisher Scientific; Waltham, MA | 8042-47-5 | RSNA recording |
Audio monitor | A-M Systems; Sequim, WA | 3300 | RSNA recording |
Silica gel | Wacker, Munchen; Germany | RT601A-B | RSNA recording |
Electrical clips | Tyco Electronics; Schaffhausen, Switzerland | EB0283-000 | Grounding or securing perfusion needle |
Bonn scissors, straight/sharp points | Roboz Surgical Instrument Co; Gaithersburg, MD | RS-5840 | Perfusion |
Gavage needle | Harvard Apparatus; Holliston, MA | 75-0286 | Perfusion |
Masterflex perfusion pump | Cole-Parmer; Vernon Hills, IL | 7524-10 | Perfusion |
Masterflex platinum-cured silicone tubing | Cole-Parmer; Vernon Hills, IL | 96410-15 | Perfusion |
Formalin (10% buffered solution; 4 L) | Sigma-Aldrich; St. Louis, MO | HT501128 | Perfusion |
Sucrose | Sigma-Aldrich; St. Louis, MO | S0389 | Cryoprotection |