Optical Recording of Neuronal Activity in Brain Slices Stained with a Voltage-Sensitive Dye

Published: October 31, 2024

Abstract

Source: Tominaga, Y., et al. Wide-field Single-photon Optical Recording in Brain Slices Using Voltage-sensitive Dye. J. Vis. Exp. (2019).

This video demonstrates a procedure for observing changes in neuronal activity in a brain slice stained with a voltage-sensitive dye. The dye reflects changes in the neuron's membrane potential by altering its fluorescence intensity. Through the application of electrical stimuli and advanced imaging techniques, this process enables visual tracking of real-time changes in neuronal membrane potential based on VSD fluorescence.

Protocol

All procedures involving animal samples have been reviewed and approved by the appropriate animal ethical review committee.

1. Daily Preparation of Experimental Apparatus

  1. Turn on the amplifier, computer, and camera system, and check that the software is running.
  2. Place artificial cerebrospinal fluid (ACSF) in a 50 mL tube and bubble with carbogen.
  3. Use a peristaltic pump to circulate the ACSF. Adjust the flow rate to approximately 1 mL/min.
  4. Adjust the height of the suction pipette so that the liquid level inside the experiment chamber is always constant.
    NOTE: The level of the solution is important to obtain a stable recording, therefore, the adjustment should be done using a micromanipulator.
  5. Install the ground electrode made up of yellow chip filled with 3 M KCl agar (2%) into a holder with an Ag-AgCl wire with small amount of 3 M KCl solution.
  6. Fill a small amount of ACSF (approximately two-third of the volume) into the glass electrode (1 mm outer diameter, 0.78 mm inner diameter pulled with a micropipette puller) using a tapered thin tubed yellow tip and place it in the electrode holder.
  7. Attach the holder to the rod installed in the manipulator. Ensure using an amplifier that the electrode resistance is approximately 1 MΩ.
    NOTE: The long-shank wide opening (4-8 µm opening) patch type electrode should be good for field recording and as a stimulating electrode.

2. Starting a Recording Session

  1. Take a slice preparation from the moist chamber with forceps.
  2. Quickly place the slice onto an experimental chamber under the microscope (Figure 1).
  3. Push the edge of the ring firmly into the silicone O-ring. Be careful not to break the membrane or the bottom of the experiment chamber.
    NOTE: The direction of the slice should be taken into consideration with respect to the direction of the stimulating and recording electrodes in the field of view. The healthy slice should stick to the membrane filter so there is no need to use other devices to fix the slices such as weights and nylon meshes.
  4. Place the tip of the stimulating electrode and the field potential recording electrode onto the slice under the microscope with transmitted light.
  5. Use the electrophysiological recording system to check the response. Confirm the usual (non-stained) electrophysiological recording with given configuration.
    NOTE: The recording electrode can be omitted but is useful to check the physiology of the slice.
  6. Adjust the excitation light intensity to approximately 70-80% of the maximum capacity at the camera that corresponds to 13-15 mW/cm2 at the specimen when sampling at 10 kHz with 5x water immersion objective lens and 1x PLAN APO tube lens. The excitation light wavelength is 530 nm, and the emission filter must be > 590 nm.
    NOTE: Use a shutter to minimize the amount of excitation light. Continuous light exposure may deteriorate the slice physiology. The possible harmful effect of the light depends on the intensity and duration of the light. Use electrophysiological recording to judge the effect of light. In case of the strength of 13-15 mW/cm2, about 1 s exposure should be the upper limit of the tolerance.
  7. Adjust the focus with the acquisition system using the fluorescent light source because the focus may be different depending on the wavelength and start the acquisition.
  8. Examine the data in an image acquisition software.
    NOTE: We used original microprogramming package of numerical analysis software for detailed analysis.

Representative Results

Figure 1
Figure 1. Recording system for optical signals from slice preparations. (A) A photograph of the microscope used to image the slices in the current manuscript. The optics consist of an objective lens (5x NA0.60), a mirror box for dichroic filter (580 nm), and a projection (tube) lens (PLAN APO x1.0). A high-speed camera is attached on the top of the projection lens through a c-mount. There is another usual USB camera for observation. Excitation light is introduced using fiber optics. (B) Photograph of the lenses that are compatible with the mirror box. (C) Schematic diagram of the recording system. The imaging system and electrophysiological recording system are controlled by a PC. LED illumination system with a photo-diode feedback control system was used as a light source.

Disclosures

The authors have nothing to disclose.

Materials

High speed image acquisition system Brainvision co. Ltd. MiCAM – Ultima Imaging system
High speed image acquisition system Brainvision co. Ltd. MiCAM 02 Imaging system
Macroscepe for wide field imaging Brainvision co. Ltd. THT macroscope macroscope
High powere LED illumination system with photo-diodode stablilizer Brainvision co. Ltd. LEX-2G LED illumination
Image acquisition software Brainvision co. Ltd. BV-ana image acquisition software
Multifunctional electric stimulator Brainvision co. Ltd. ESTM-8 Stimulus isolator+AD/DA converter
Membrane filter for slice support Merk Millipore Ltd., MA, USA Omnipore, JHWP01300, 0.45 µm pores, membrane filter/ 0.45 13
Numerical analysis software Wavemetrics Inc., OR, USA IgorPro analysing software
Stimulation isolator WPI Inc. A395 Stimulus isolator
AD/DA converter Instrutech ITC-18 AD/DA converter
Voltage sensitive dye Di-4-ANEPPS Invitrogen, Thermo-Fisher Scientific, Waltham, MA, USA catalog number: D-1199 VSD: Di-4-ANEPPS
Polyethoxylated castor oil Sigma-Aldrich Cremophor EL C5135 polyethoxylated castor oil

Play Video

Cite This Article
Optical Recording of Neuronal Activity in Brain Slices Stained with a Voltage-Sensitive Dye. J. Vis. Exp. (Pending Publication), e22736, doi: (2024).

View Video