Source: Hay, C. A. et al. Ultrasound-Guided Orthotopic Implantation of Murine Pancreatic Ductal Adenocarcinoma. J. Vis. Exp. (2019).
This video describes the protocol for ultrasound-guided orthotopic implantation of murine-derived pancreatic ductal adenocarcinoma cells directly into the pancreas of the mouse. This causes less inflammation at the implantation site compared to surgical procedures.
All procedures involving animal models have been reviewed by the local institutional animal care committee and the jove veterinary review board.
1. Pre-Surgical Preparation of Mice
NOTE: This step is recommended to be performed 24 hours prior to the procedure.
2. Ultrasound-Guided implantation of PDA cells
NOTE: All ultrasound procedures are performed using ultrasound imaging machine and software (see Table of Materials). The transducer has a center frequency of 40 MHz and a bandwidth of 22-55 MHz.
Figure 1: Ultrasound-guided implantation of PDA cells into the murine pancreas. (A) Orientation of mouse, ultrasound stage, and ultrasound probe used to obtain a high-resolution image of abdominal organs. Note the stage and platform have been turned 90° from the standard orientation to allow easy access to the upper left quadrant of mouse abdomen. (B) Ultrasonographic image depicting the identification of kidney, spleen and pancreas. Here the injection needle is positioned against the mouse abdomen. (C) Ultrasonographic image depicting the needle within the mouse pancreas. (D) Ultrasonographic image depicting the bubble at the injection site (outlined in blue) following controlled injection of tumor cells into the pancreas. (E) Laparotomy revealing the fluid bolus containing PDA cells in the pancreas after ultrasound guided injection. Please click here to view a larger version of this figure.
The authors have nothing to disclose.
50 mL Conicals | Thomas Scientific | 2602A26 | |
Blunt edged forceps | Fine Science Tools | 11000-12 | |
Cell Dissociation Buffer | Thermo-Fisher | 13151014 | |
Cotton Tipped swabs | Thermo-Fisher | 19062614 | |
Covidien Monoject 3/10mL, 29G X 1/2" | Thermo-Fisher | 8881600145 | |
Depilatory Agent | Amazon | Nair Body Lotion | |
Forceps (blunt edge) | Fine Science Tools | 11000-12 | |
Gauze | Fisher | 13-761-52 | |
Gentamicin | Thermo-Fisher | 15750060 | |
Induction Chamber | VetEquip | 941444 | |
Isofluorane | Penn Vet Supply | VED1350 | |
Isofluorane Vaporizer | VetEquip | 911103 | |
L-glutamine | Thermo-Fisher | 25030081 | |
Optixcare | MidWest Veterinary Supply | 052.50310.3 | |
Paper Tape | Medline | MMM1530Z5 | |
PBS | Thermo-Fisher | 14-190-250 | |
Slide warmer | C&A Scientific | XH-2001 | |
Sterilant (Clidox-S) | Fisher Scientific | NC0332382 (activator) NC9189926 (base) | Needs to be combined according to manufacturer's instructions |
Sterile Alcohol prep pad | Covidien | 6818 | |
Trypsin | Thermo-Fisher | 15090046 | |
Ultrasound gel | Thermo-Fisher | 03-34-1LT | |
Visualsonics Ultrasound Vevo 2100 | Visual Sonics | Vevo 2100 |