Encyclopedia of Experiments
Biological Techniques
A subscription to JoVE is required to view this content.  Sign in or start your free trial.
Encyclopedia of Experiments Biological Techniques
High-Performance Thin Layer Chromatography: A Technique for Preliminary Separation and Quantification of Lipids From Neutrophils

High-Performance Thin Layer Chromatography: A Technique for Preliminary Separation and Quantification of Lipids From Neutrophils

Transcript

To begin, fill up to 5 milliliters of each solution in the corresponding glass chamber. Add any kind of filter paper to increase the running speed in each chamber. Pre-incubate a 20 x 10-centimeter HPTLC silica gel 60 glass plate in the first running solution. Once the running solution reaches the top of the plate, dry it for 10 minutes at 110 degrees Celsius.

Dissolve the liquid pellet previously obtained after drying with a vacuum concentrator, in the desired volume of 1:1 chloroform/methanol solution, and incubate for 15 minutes at 37 degrees Celsius to dissolve. Next, use a ruler and a soft pencil to mark the loading spots for the desired number of samples, plus at least one standard. Mark the running distance at approximately 4 centimeters for the first running solution, and at approximately 6 centimeters for the second running solution.

To load the samples, wash the 10-microliter syringe three times, in 1:1 chloroform/methanol, prior to loading each new sample. Load 10 microliters of each sample dropwise, trying to concentrate the sample on as small an area as possible. Place the plate vertically into the first chamber with running solution #1. Ensure that the plate is parallel to the wall of the glass chamber, to achieve a uniform migration speed.

Together the plates are placed parallel to the back wall of the glass chambers, and the solvent fronts do not run too far to ensure that the lipids are efficiently separated.

Once the solvent line has reached the first mark, remove the plate, dry it, and place it in the second solution. Repeat similar steps for the second, and for the third running solutions. Leave the plate in the solution until the solvent front reaches the top of the plate. Then, remove the plate, and dry it at room temperature for one minute.

Place the plate in the copper sulfate solution for seven seconds. After drying the plate thoroughly, bake it in an oven for seven minutes at 170 degrees Celsius. Remove the plate from the oven and allow it to cool.

Related Videos

Read Article