Source: Wickham, R. J., et al. Combined Infusion and Stimulation with Fast-Scan Cyclic Voltammetry (CIS-FSCV) to Assess Ventral Tegmental Area Receptor Regulation of Phasic Dopamine. J. Vis. Exp. (2020).
This video demonstrates the implantation of electrodes and cannulas in an anesthetized rat to measure dopamine release in the nucleus accumbens using a potentiostat and the infusion of drugs to modulate dopaminergic activity in the ventral tegmental area.
All procedures involving animal models have been reviewed by the local institutional animal care committee and the JoVE veterinary review board.
1. Presurgical preparations
2. Electrode implantations
3. Optimizing carbon fiber and stimulating electrode/guide cannula locations
4. Combination infusion and stimulation FSCV recording
NOTE: Figure 1 shows the timeline for recording before and after VTA microinfusion.
Figure 1: Timeline for recording before and after VTA microinfusion.
The authors have nothing to disclose.
Electrode Filling Solution/Supplies | |||
Micropipette | World Precision Instruments | MF286-5 (28 gauge) | |
Potassium Acetate | Sigma | 236497-100G | |
Potassium Chloride | Sigma | P3911-25G | |
Electrode Supplies | |||
Carbon fiber | Thornel | T650 | |
Electrode puller | Narishige International | PE-22 | Note: horizontal pullers can be used as well |
Glass capillary | A-M systems | 626000 | |
Insulated wires for electrodes | Weico Wire and Cable Incorporated | UL 1423 | Length; 10 cm; diameter,0.4mm; must get custom made; insulated material should cover 5 cm of the wire |
Light Microscope (for viewing and cutting electrode) | Fischer Scientific | M3700 | |
Pin | Phoenix Enterprises | HWS1646 | To be soldered onto the insuled electrode wire and reference electrode; connects to headstage |
Putty | Alcolin | 23922-1003 | Used to place electrode on while cutting the carbon fiber |
Scalpal Blade | World Precision Instruments | 500239 | For cutting carbon fiber to the apprpriate length |
Silver Wire | Sigma | 327026-4G | |
FSCV Hardware/Software | |||
Faraday Cage | U-Line | H-3618 (36" x 24" x 42") | |
Potentiostat | Univ. of N. Carolina, Electronics Facility | ||
Stimulating electrode | PlasticsOne | MS303/2-A/SPC | when ordering, request a 22 mm cut below pedestal |
TarHeel HDCV Software | University of North Carolina-Chapel Hill | – | https://chem.unc.edu/critcl-main/criticl-electronics/criticl-electronics-hardware/ for ordering information |
UEI breakout box | Univ. of N. Carolina, Electronics Facility | https://chem.unc.edu/critcl-main/criticl-electronics/criticl-electronics-hardware/ for ordering information | |
UEI power supply | Univ. of N. Carolina, Electronics Facility | https://chem.unc.edu/critcl-main/criticl-electronics/criticl-electronics-hardware/ for ordering information | |
Stimulator Hardware | |||
Neurolog stimulus isolator | Digitimer Ltd. | DS4 | Neurolog 800A |
Infusion/Stimulation Supplies | |||
Infusion Pump | New Era Syringe Pump | NE-300 | |
Internal Cannula | PlasticsOne | C315I/SPC INTERNAL 33GA | |
Microliter Syringe | Hamilton | 80308 | |
Tubing | PlasticsOne | C313CT/ PKG TUBING 023 X 050 PE50 | |
Surgical Supplies | |||
Cannula Holder | Kopf Instruments | 1776 P-1 | |
Cotton Tip Applicators | Vitality Medical | 806 | |
Electrode Holder | Kopf Instruments | 1770 | |
Heating Pad | Kent Scientific | RT-0501 | |
Povidone Iodine | Vitality Medical | 29906-004 | |
Screws | Stoelting | Bone Anchor Screws/Pkg.of 100 | 1.59 mm O.D., 3.2 mm long |
Silver wire reference with AgCl | InVivo Metric | E255A | |
Square Gauze | Vitality Medical | 441408 | |
Stereotax | Kopf Instruments | Model 902 (Dual Arm Bar) | |
Drugs for infusions | |||
((2R)-amino-5-phosphonovaleric acid | Sigma Aldrich | A5282 | |
N-methyl-D-aspartate | Sigma Aldrich | M3262 | |
Mecamylamine hydrochloride (M9020-5mg) | Sigma Aldrich | M9020 | |
Scopolamine hydrobromide (S0929-1g) | Sigma Aldrich | S0929 |