Source: Sauer, J., et al. Recording Spatially Restricted Oscillations in the Hippocampus of Behaving Mice. J. Vis. Exp. (2018).
This video outlines a protocol for implanting a multi-shank linear silicon probe into the mouse brain to measure local field potentials. The procedure involves securing the probe to a stereotaxic unit, positioning it accurately over the target brain region, inserting it into the brain, and securing it with dental cement. After implantation, the assembly is protected with a casing. Following recovery, the setup allows for recording local field potentials, providing insights into neuronal activity.
All procedures involving animal models have been reviewed by the local institutional animal care committee and the JoVE veterinary review board.
1. Preparations
2. Implantation Surgery
3. Recovery After Surgery
4. Data Acquisition
Figure 1: Image of the insertion tool. The silicon probe is attached to an insect pin glued to the base of a crocodile clamp. The shaft of the holder can be inserted in a stereotaxic micro manipulator for implantation.
The authors have nothing to disclose.
Crocodile clamp with stand | Reichelt Elektronik | HALTER ZD-10D | |
Silicon probe | Cambridge Neurotech | P-series 32 | |
Stereoscope | Olympus | SZ51 | |
Varnish-insulated copper wire | Bürklin Elektronik | 89 F 232 | |
Ground screws | Screws & More GmbH (screwsandmore.de) | DIN 84 A2 M1x2 | |
Flux | Stannol | 114018 | |
Ceramic-tipped forceps | Fine Science Tools | 11210-60 | |
Paraffine Wax | Sigma-Aldrich | 327204 | |
Cauterizer | Fine Science Tools | 18010-00 | |
Soldering iron | Kurtz Ersa | OIC1300 | |
Ethanol | Carl Roth | 9065.1 | |
Pasteur pipettes | Carl Roth | EA65.1 | |
Heat sterilizer | Fine Science Tools | 18000-45 | |
Stereotaxic frame | David Kopf | Model 1900 | |
Stereotaxic electrode holder | David Kopf | Model 1900 | |
Isoflurane | Abbvie | B506 | |
Oxygen concentrator | Respironix | 1020007 | |
Buprenorphine | Indivior UK Limited | ||
Electrical shaver | Tondeo | Eco-XS | |
Heating pad | Thermolux | 463265/-67 | |
Surgical clamps | Fine Science Tools | 18050-28 | |
Hydrogen peroxide | Sigma-Aldrich | H1009 | |
Sterile cotton wipes | Carl Roth | EH12.1 | |
Drill | Proxxon | Micromot 230/E | |
21G injection needle | B. Braun | 4657527 | |
Phosphate buffer/phosphate buffered saline | |||
Stereotaxic atlas | Elsevier | 9.78E+12 | |
Surgical scissors | Fine Science Tools | 14094-11 | |
Surgical forceps | Fine Science Tools | 11272-40 | |
27G injection needles | B. Braun | 4657705 | |
Vaseline | |||
Dental cement | Sun Medical | SuperBond T&M | |
Carprofen | Zoetis | Rimadyl 50mg/ml | |
Recording amplifier | Intan Technologies | C3323 | |
USB acquisition board | Intan Technologies | C3004 | |
Recording cables | Intan Technologies | C3216 | |
Electrical commutator | Doric lenses | HRJ-OE_FC_12_HARW |