Diagnosis of Eimeria infection in chickens remains demanding. Parasite morphology- and host pathology-led approaches are commonly inconclusive, while molecular approaches based on PCR have proven demanding in cost and expertise. The aim of this protocol is to establish loop-mediated isothermal amplification (LAMP) as a straightforward molecular diagnostic for eimerian infection.
Eimeria species parasites, protozoa which cause the enteric disease coccidiosis, pose a serious threat to the production and welfare of chickens. In the absence of effective control clinical coccidiosis can be devastating. Resistance to the chemoprophylactics frequently used to control Eimeria is common and sub-clinical infection is widespread, influencing feed conversion ratios and susceptibility to other pathogens such as Clostridium perfringens. Despite the availability of polymerase chain reaction (PCR)-based tools, diagnosis of Eimeria infection still relies almost entirely on traditional approaches such as lesion scoring and oocyst morphology, but neither is straightforward. Limitations of the existing molecular tools include the requirement for specialist equipment and difficulties accessing DNA as template. In response a simple field DNA preparation protocol and a panel of species-specific loop-mediated isothermal amplification (LAMP) assays have been developed for the seven Eimeria recognised to infect the chicken. We now provide a detailed protocol describing the preparation of genomic DNA from intestinal tissue collected post-mortem, followed by setup and readout of the LAMP assays. Eimeria species-specific LAMP can be used to monitor parasite occurrence, assessing the efficacy of a farm’s anticoccidial strategy, and to diagnose sub-clinical infection or clinical disease with particular value when expert surveillance is unavailable.
La production de poulet mondial a été multiplié par dix au cours des dernières 50 années avec le monde en développement qui accueillent près de quatre fois l'expansion assisté dans le monde développé (www.faostat.org) . Comme la pertinence de la production de poulet à la sécurité alimentaire mondiale a augmenté de façon trop a le profil d'agents pathogènes qui peuvent causer une maladie grave chez les poulets. Un excellent exemple est l'espèce Eimeria, protozoaires parasites omniprésents qui peuvent causer la maladie entérique une coccidiose. Partout où les poulets sont élevés une ou plusieurs espèces d'Eimeria sont susceptibles d'être commune 2-4. Dans le monde développé Eimeria sont principalement contrôlée par la chimioprophylaxie, employant programmes de navette ou de rotation pour minimiser l'impact de la résistance 5. Les vaccins vivants sont également utilisés dans les systèmes où la valeur des oiseaux est suffisant pour justifier le coût (par exemple, les animaux reproducteurs, des couches et des poulets de chair 5). En resull de ces mesures coccidiose clinique est souvent bien contrôlé, bien que l'infection sous-clinique est commune 5. Dans le monde en développement de la vaccination est rare et la demande de drogues souvent moins bien informé. En conséquence coccidiose sous-clinique et clinique est plus fréquente et exerce un impact économique significatif 3.
Diagnostic de l'infection eimerian a toujours compté sur lésion totalisant post-mortem, bien que même les auteurs de le système de notation plus largement utilisé remarquer que pour certaines espèces "il semble douteux qu'une telle procédure devrait être tentée dans tout mais modérément sévères infections" 6. Preuve supplémentaire peut être recueillie grâce à la détection au microscope au stade résistant à l'environnement du cycle de vie des oocystes dans des échantillons fécaux ou litière, bien que se chevauchant morphologie peut confondre tous, mais l'expert 6,7. Alternatives moléculaires utilisant la réaction en chaîne par polymérase (PCR), amplificatio aléatoiren de l'ADN polymorphe PCR (RAPD-PCR) et des technologies de PCR quantitative ont été disponibles pour un maximum de 20 années 8-10, mais à ce jour ils ne ont pas réussi à devenir populaire. Coût relatif et l'exigence de l'équipement de laboratoire spécialiste ou traitement ont limité leur adoption, en dépit de la nature souvent subjective et techniquement exigeante de la pathology- plus âgés et les approches basées sur la microscopie-10,11. Ces limitations peuvent être exagérées dans la plupart des régions les plus pauvres du monde comme l'Asie du Sud-Est, où l'impact de la coccidiose sur la pauvreté peut être proportionnellement plus 12. En réponse il ya une demande claire pour des tests de diagnostic, nouvelle Eimeria espèces spécifiques simple et sensible, mais rentable.
Boucle amplification isotherme facilitée (LAMP) est une technique facile à préparer entraînée par polymérase-ADN qui est capable d'amplifier de grandes quantités d'ADN. Plus important encore, LAMP utilise un polymera Bst ADNSE au lieu de l'ADN polymerase Taq utilisée dans la PCR, ce qui facilite l'amplification d'ADN à une température constante sans la seule exigence pour le cyclage thermique 13,14. LAMP peut se prêter à l'application même dans le laboratoire le plus rudimentaires ou dans le domaine. Caractérisée par la résistance par rapport à de nombreux inhibiteurs de la PCR, haute sensibilité et spécificité, des tests de LAMP ont été élaborés pour un large éventail d'agents pathogènes y compris le virus de la maladie de Gumboro, Clostridium perfringens et Cryptosporidium 15-17. En réponse à la demande pour de nouveaux diagnostics Eimeria rentables espèces spécifiques d'un panel de tests LAMP spécifiques à chacune des sept espèces d'Eimeria qui infectent les poulets a été développé 18. Applications pour les nouveaux tests comprennent la surveillance parasite occurrence, d'une valeur particulière donnée l'association d'espèces telles que Eimeria maxima ou Eimeria necatrix avec une mauvaise pe économiquerformance 3,4. D'autres applications comprennent l'évaluation de l'efficacité de la stratégie anticoccidienne d'une ferme, le diagnostic de l'infection sous-clinique ou clinique de la maladie et l'évaluation des risques posés par Eimeria à une ferme.
The Eimeria species-specific LAMP assays described in this paper offer a new diagnostic tool kit in support of effective control of coccidia and the disease coccidiosis. The outcomes of eimerian infection can include severe economic loss as well as seriously compromised bird welfare and increased susceptibility to colonisation by zoonotic pathogens21. Opportunities to monitor flocks for the occurrence of some, or all Eimeria species can provide early warning of a breakdown in anticoccidial control efficacy. Key advantages of LAMP include robust target specificity, resulting from the requirement for six different DNA sequence targets, as well as high sensitivity, boosted by the inclusion of loop primers13, although the qualitative, not quantitative nature of LAMP may be considered a limitation. It is not currently possible to discriminate low level parasite escape from routine chemoprophylaxis or live vaccine replication from unchecked eimerian replication. Nonetheless, the technical ease of the protocol and definitive readout offers considerable improvement over the existing specialist and frequently subjective pathology- and morphology-led approaches6,7. Each assay may be completed at a cost of ~£0.75 per sample, independent of labour and equipment set up expenses. Thus, LAMP assays are also more cost effective than other molecular diagnostics such as PCR, since they require an isothermal incubation with no need for specialist equipment.
For many years access to Eimeria genomic DNA as template has limited the development and application of molecular field diagnostics. The oocyst is the most readily accessible phase of the eimerian lifecycle, but routine DNA extraction requires laboratory facilities22. Other, more labile intestinal lifecycle stages require purification prior to DNA preparation to prevent PCR inhibition and a consequent loss of sensitivity23,24. The ability to extract eimerian DNA of a quality suitable for LAMP using equipment no more specialised than a microcentrifuge and a water bath, supplemented by inhibitor adsorption using chelex resin, now promotes the wider use of molecular biology in eimerian diagnostics. Intriguingly, the reported detection of quantitative PCR-measurable Eimeria DNA in intestinal tissue 20 days after the initiation of parasite infection, 11 days after the last detectable oocyst output, raises the suggestion that LAMP may be used to detect resolved parasite exposure as well as ongoing infection, even after any visible lesions may have been resolved25.
The relatively low cost and low technical requirements of LAMP Eimeria diagnostics can promote their application in the developing world where other more established approaches may not be available or appropriate. For this to be applicable each assay must be capable of detecting all strains which may be circulating within each region. While understanding of the genetic diversity prevailing among Eimeria species is limited26, the use of target sequences previously validated for use in quantitative PCR with strains from Africa, Asia, Europe and South America provides some evidence of conservation, supporting the utility of these LAMP assays around the world10.
The authors have nothing to disclose.
The work carried out in this study was supported in part by the Royal Veterinary College through the student research projects fund, as well as the Biotechnology and Biological Sciences Research Council and the Department for International Development (grant number BB/H009337/2). This manuscript has been assigned the reference PPB_00795 by the RVC.
Name | Company | Catalogue number | Comments |
RNAlater | Ambion | AM7024 | |
Ethanol | VWR Chemicals | 20821.321 | Caution, highly flammable |
100 x Tris-EDTA (TE) buffer concentrate | Sigma-Aldrich | T9285 | |
Chelex 100 resin | Bio-Rad | 142-1253 | |
Molecular grade water | Invitrogen | 10977035 | |
E. acervulina F3 | Sigma-Aldrich | VC00021 | *CCTAACATTTCGCTTCACGGAC |
E. acervulina B3 | Sigma-Aldrich | VC00021 | *ATGAGCAAGTGGAACACCTTG |
E. acervulina FIP | Sigma-Aldrich | VC00021 | *AGAGCACAGTGGCAGTGC-AGCAGACAGCATGGCTTACCT |
E. acervulina BIP | Sigma-Aldrich | VC00021 | *GAAGACCCTCTGAAGAACGGA-CCTTCTCACCGCTTACCGG |
E. acervulina LB | Sigma-Aldrich | VC00021 | *TAAGGTTACACCCGTGGAGG |
E. acervulina LF | Sigma-Aldrich | VC00021 | *GCCATGCACAAAGCGACTT |
E. brunetti F3 | Sigma-Aldrich | VC00021 | *GGCCATCAAGTTCCATGAGC |
E. brunetti B3 | Sigma-Aldrich | VC00021 | *TCAACCTCCTGAGTGTGGTT |
E. brunetti FIP | Sigma-Aldrich | VC00021 | *GAAAATGCCTTCGTAGCTGCT-GCTGGGTACGGAGCGTCTT |
E. brunetti BIP | Sigma-Aldrich | VC00021 | *TACTTCCTAGGATCCATCCTCGC-AGTTTCGCTGCCGCCTC |
E. brunetti LB | Sigma-Aldrich | VC00021 | *GAAACGCTCGAACATGGC |
E. brunetti LF | Sigma-Aldrich | VC00021 | *CTTCTCCACAGACCCAGAGGT |
E. maxima F3 | Sigma-Aldrich | VC00021 | *ACTACGGAAAAGTGCGTAGCT |
E. maxima B3 | Sigma-Aldrich | VC00021 | *CCTTCCTCCCTTCTGAAAACTG |
E. maxima FIP | Sigma-Aldrich | VC00021 | *GAGTCACTGCTGATGTACCAAA AG-GAACTATGCCGCTTTCCCCTG |
E. maxima BIP | Sigma-Aldrich | VC00021 | *AGAATGCGGATTTGTTAGCAGC-AGCAAGTCCAAGGTGTGTGTA |
E. maxima LB | Sigma-Aldrich | VC00021 | *CAAGCCTACGCGGACATC |
E. maxima LF | Sigma-Aldrich | VC00021 | *TTATGCAGCTGGGTCAACG |
E. mitis F3 | Sigma-Aldrich | VC00021 | *ACGATAGCCAAGACACGTAAGG |
E. mitis B3 | Sigma-Aldrich | VC00021 | *CCCCGTGATAAGAGTAGGAACA |
E. mitis FIP | Sigma-Aldrich | VC00021 | *CGCGGGTCGTGAGATTTAAATT AT-GGAAGATCAGGACGGGCACT |
E. mitis BIP | Sigma-Aldrich | VC00021 | *GTTTCAGTTGATGAACAAGCGA GA-TGCGCCTCTAGAATCAAGACG |
E. mitis LB | Sigma-Aldrich | VC00021 | *TCCATGCATCCCCTTGTT |
E. mitis LF | Sigma-Aldrich | VC00021 | *CGTGGGCACAGATTGATTC |
E. necatrix F3 | Sigma-Aldrich | VC00021 | *TGGCTTTCCCGCGTACC |
E. necatrix B3 | Sigma-Aldrich | VC00021 | *CGGCCCAACACAAAGACTG |
E. necatrix FIP | Sigma-Aldrich | VC00021 | *CGCTTGAGTTTTAAGCTATGCA CA-GACCCAAGCAGCTCACCAA |
E. necatrix BIP | Sigma-Aldrich | VC00021 | *CGCCATGCCATTCAATGAACG-*GAGGCATACCGGCGTTGTC |
E. necatrix LB | Sigma-Aldrich | VC00021 | *GTCTGTAACTTGGGACGTTGT |
E. necatrix LF | Sigma-Aldrich | VC00021 | *GAACAGCCGGAGCCTCTC |
E. praecox F3 | Sigma-Aldrich | VC00021 | *GCCCTTGTATGTTGCTGTTTCT |
E. praecox B3 | Sigma-Aldrich | VC00021 | *GCGCACGAATCTGAATCACAC |
E. praecox FIP | Sigma-Aldrich | VC00021 | *ATCTCCTCAAAGACTTTCGCGT A-GCGCTTGGCTATATCCATAGG |
E. praecox BIP | Sigma-Aldrich | VC00021 | *GCTCTCGTGGCATACTTGC-GCCAGGAGCCACTGATTGT |
E. praecox LB | Sigma-Aldrich | VC00021 | *GAATAGCATTGCCAGGTGG |
E. praecox LF | Sigma-Aldrich | VC00021 | *GTCCACTGTCATTAATATTGC TGC |
E. tenella F3 | Sigma-Aldrich | VC00021 | *GCTTGTGAAGGTCAGCGTG |
E. tenella B3 | Sigma-Aldrich | VC00021 | *GCTGAGTCCATACGTACTTCCT |
E. tenella FIP | Sigma-Aldrich | VC00021 | *GCCACTGCTATGGAAAGTCAC AC-CATAACTGGCATGCAGGGGT |
E. tenella BIP | Sigma-Aldrich | VC00021 | *GTTTGGCCCGAAAGTTGTGAA GA-CGTCAGAAATTGCTGCCCAAT |
E. tenella LB | Sigma-Aldrich | VC00021 | *CGCATGTGCAGTTGAAGACA |
E. tenella LF | Sigma-Aldrich | VC00021 | *CCAAATGTATCTGCTAGTTATA TTAACAAG |
10 x ThermoPol reaction buffer | New England Biolabs | B9004S | |
MgSO4 | Sigma-Aldrich | M7506 | |
dNTPs | Promega | U1330 | |
Betaine solution (5 M) | Sigma-Aldrich | B0300 | |
Bst polymerase | New England Biolabs | M0275S | |
Hydroxynaphthol blue | Sigma-Aldrich | 33936 | Dissolved in molecular grade water. |
UltraPure agarose | Invitrogen | 16500-500 | |
10 x Tris/Borate/EDTA (TBE) buffer | Invitrogen | AM9863 | |
Blue/Orange DNA loading dye (x6) | Promega | G1881 | |
GeneRuler 1Kb DNA ladder | Thermo Scientific | SM0313 | |
SafeView nucleic acid stain | NBS Biologicals | NBS-SV |