Source: Chen, B. et al., Facilitating Cerebral Organoid Culture via Lateral Soft Light Illumination. J. Vis. Exp. (2022).
This video showcases the utilization of a lateral soft light illumination technique to improve the naked-eye visualization of embryoid bodies, thereby facilitating their manipulation and transfer during cerebral organoid culture. It elucidates the setup of soft light illumination, methods for media changes and embryoid body transfer, as well as the procedure for inducing neural differentiation in embryoid bodies for cerebral organoid development.
All procedures involving sample collection have been performed in accordance with the institute's IRB guidelines.
1. Preparation of the soft light lamp (day 1)
2. EB transfer and medium replacement (days 2-5)
3. Neural induction (days 5-7)
Table 1. Composition of the Neural induction medium
Components | Volume |
DMEM-F12 | 97 mL |
N2 supplement | 1 mL |
Glutamax supplement | 1 mL |
MEM-NEAA | 1 mL |
Heparin | Final concentration 1 μg/mL |
Figure 1: Preparation of the soft light lamp. (A) The power supply and the LED lights were installed on one side of the acrylic board (as shown in the red dotted box). The LED soft light lamp's scattering wavelength is 450-470 nm, luminous flux is 1300-1800 lm, and color rendering index is 75-85 Ra. (B) It was checked whether the LED bulbs could light normally (as shown in the red dotted box). (C) A white pad was pasted on the front and back of the acrylic plate (as indicated by the red arrows). (D) The overall appearance of the soft light lamp. (E) The soft light lamp can also be replaced by a commercial LED painting light pad without a frame, which is usually used for tracking when copying sketches. A layer of white film needs to be pasted directly above the LED painting light pad. (F)The soft light lamp at work.
Figure 2: Optimized medium change and transfer operations of EBs. (A) EB preparation. The iPSCs were digested and added to the specialized 24-well plates (left). The cells formed EBs (right). The scale bar is 400 µm. (B) Schematic diagram of laterally illuminated soft light to assist in observing organoids. (C) The EBs were observed with different light sources. Yellow arrow: laterally illuminated light; red arrow: dark background; green arrows: EBs. (D) A swirl flow is induced by rotating the dish along a circular orbit. Due to the swirl flow, a secondary flow directed toward the center is induced. The EBs converge to the center of the dish driven by the secondary flow generated through rotation. White arrows: EBs. (E) Organoid transfer. (I) First, a wide-mouth pipette tip is used to suck up the mixture solution, including both the EBs and the culture medium. (II) Then, while keeping the pipette upright, the EBs gradually sink under the gravity effect and converge towards the mouth of the pipette tip. (III) As the mouth of the pipette tip touches the liquid (usually the fresh medium) surface again, and due to liquid surface tension, (IV) the EBs quickly sink into the medium (no need for additional blowing out by pipetting manually). Red line: the liquid level; yellow arrows: EBs. (F) Since free cells and dead cell fragments sink more slowly than EBs, most of the free cells and dead cell fragments can thus be removed through the above sedimentation method to facilitate the embryoid transfer. The red box in the upper right corner is an enlarged image. The scale bar is 400 µm.
The authors have nothing to disclose.
0.2 μm Filter | NEST Biotechnology, China | 331001 | |
1000 μL wide-bore pipette tip | Thermo Fisher Scientific, USA | 9405163 | |
6-well low adhesion plate | NEST Biotechnology, China | 703011 | It is used for EBs suspension cultures |
Centrifuge | Eppendorf, Germany | 5810 R | It can be used for centrifugation of various types of centrifuge tubes, reagent bottles and working plates. |
DMEM-F12 | Thermo Fisher Scientific, USA | 11330032 | |
Heparin | Merck, Germany | H3149 | |
Glutamax supplement | Thermo Fisher Scientific, USA | 35050061 | |
Glutamax supplement | Thermo Fisher Scientific, USA | 17504044 | |
MEM-NEAA | Thermo Fisher Scientific, USA | 11140050 | |
N2 supplement | Thermo Fisher Scientific, USA | 17502048 | |
Soft light lamp | NUT | NUT | A simple self made device, refer to supplementary figure 2 for preparation. |