Source: Huyett, P. et al. A Model for Perineural Invasion in Head and Neck Squamous Cell Carcinoma. J. Vis. Exp. (2017)
In this video, we demonstrate the procedure for developing an in vitro perineural cancer cell invasion model by co-culturing mouse dorsal root ganglion and neurotropic cancer cells. The model can be utilized to conduct cancer assays, producing rapid and reproducible results.
All procedures involving animal models have been reviewed by the local institutional animal care committee and the JoVE veterinary review board.
1. Preparation of Semi-solid Matrix Droplets (< 1 min per plate)
2. Insertion of DRG into Semi-solid Matrix Droplets (< 2 min per plate)
3. Preparation of the Head and Neck Cancer Cells
NOTE: Cell lines other than head and neck squamous cell carcinoma cells can be used in this experimental design.
4. Plating Head and Neck Cancer Cells
Figure 1. DRG-matrix assay. Correct placement of the dorsal root ganglion within the matrix droplet, shown with brightfield microscopy at 4X. Scale bar represents 1 mm.
Figure 2. Outgrowth of neurites. Neurites are absent on day 0 immediately after placing the DRG in the matrix droplet (A). By day 1 (B), neurite outgrowth is apparent at 10X on brightfield microscopy. Neurite growth continues on day 2 (C) and day 3 (D); however, note the efflux of the fibroblasts. Scale bar represents 0.1 mm.
Figure 3. DRG-matrix assay with FaDu. Head and neck squamous cell carcinoma line FaDu added peripherally around an assay on day 3 (A), shown in green fluorescent, and brightfield microscopy at 4X Progressive neural invasion is seen on day 4 (B) and day 5 (C). Scale bar represents 1 mm.
The authors have nothing to disclose.
DMEM/F-12 50/50 Mix with L-glutamine & 15 mM HEPES | Corning Cellgro | 10-090-CV | Manassas, VA |
Fetal bovine serum | Atlanta biologicals | S11150 | Flowery Branch, GA |
0.25% Trypsin-EDTA (1x) | Life Technologies Corporation | 25200056 | Grand Island, NY |
Phosphate buffered Saline 1x | Corning | 21-040-CM | Manassas, VA |
Matrigel hESC-Qualif Mouse | Corning Incorporated | 354277 | Bedford, MA |
Gamma Irradiated 35 mm glass bottom culture dishes | MatTek Corporation | P35G-1.5-14-C | Ashland, MA |
SteREO Discovery.V8 Operating Microscope | Carl Zeiss Microimaging | 495015-0021-000 | Thornwood, NY |
Schott ACE I light source | Schott | A20500 | Germany |
CellTracker | Life Technologies Corporation | C2925 | Carlsbad, CA |
BD PrecisionGlide Needle 21 G | BD | 305195 | Franklin Lakes, NJ |