Source: Whitney Swanson1,2, Frances V. Sjaastad2,3, and Thomas S. Griffith1,2,3,4
1 Department of Urology, University of Minnesota, Minneapolis, MN 55455
2 Center for Immunology, University of Minnesota, Minneapolis, MN 55455
3 Microbiology, Immunology, and Cancer Biology Graduate Program, University of Minnesota, Minneapolis, MN 55455
4 Masonic Cancer Center, University of Minnesota, Minneapolis, MN 55455
Enzyme-linked immunosorbent assay (ELISA) is frequently used to measure the presence and/or concentration of an antigen, antibody, peptide, protein, hormone, or other biomolecule in a biological sample. It is extremely sensitive, capable of detecting low antigen concentrations. The sensitivity of ELISA is attributed to its ability to detect the interactions between a single antigen-antibody complex (1). Moreover, the inclusion of an enzyme-conjugated antigen-specific antibody permits the conversion of a colorless substrate into a chromogenic or fluorescent product that can be detected and easily quantitated by a plate reader. When compared to the values generated by titrated amounts of a known antigen of interest, the concentration of the same antigen in the experimental samples can be determined. Different ELISA protocols have been adapted to measure antigen concentrations in a variety of experimental samples, but they all have the same basic concept (2). Choosing the type of ELISA to perform, indirect, sandwich, or competitive, depends on a number of factors, including the complexity of the samples to be tested and the antigen-specific antibodies available to use. The indirect ELISA is frequently used to determine the outcome of an immunological response, such as measuring the concentration of an antibody in a sample. The sandwich ELISA is best suited for analyzing complex samples, such as tissue culture supernatants or tissue lysates, where the analyte, or antigen of interest, is part of a mixed sample. Finally, the competitive ELISA is most often used when there is only one antibody available to detect the antigen of interest. Competitive ELISAs are also useful for detecting a small antigen with only a single antibody epitope that cannot accommodate two different antibodies due to steric hinderance. The protocol will describe the basic procedures for the indirect, sandwich, and competitive ELISA assays.
The indirect ELISA assay is commonly used to measure the amount of antibodies in serum or in the supernatant of a hybridoma culture. The general procedure for the indirect ELISA assay is:
The sandwich ELISA assay differs from the indirect ELISA assay in that the method does not involve coating the plates with a purified antigen. Instead, a "capture" antibody is used to coat the wells of the plate. The antigen is "sandwiched" between the capture antibody and a second "detection" enzyme-conjugated antibody – where both antibodies are specific for the same antigen, but at different epitopes (3). By binding to the capture antibody/antigen complex, the detection antibody remains in the plate. Either monoclonal antibodies or polyclonal antisera can be used as the capture and detection antibodies. The main advantage of the sandwich ELISA is that the sample does not have to be purified before analysis. Moreover, the assay can be quite sensitive (4). Many commercially available ELISA kits are of the sandwich variety and use tested, matched pairs of antibodies. The general procedure for the sandwich ELISA assay is:
Most commercially available sandwich ELISA kits come with enzyme-conjugated detection antibodies. In cases where an enzyme-conjugated detection antibody is not available, a secondary enzyme-conjugated antibody specific for the detection antibody can be used. The enzyme on the secondary antibody performs the same role, which is to convert the colorless substrate to a chromogenic or fluorescent product. The above-mentioned secondary enzyme-conjugated antibody would more like to be used in a "homemade" sandwich ELISA developed by an investigator who has generated their own monoclonal antibodies, for example. One drawback to using a secondary enzyme-conjugated antibody is to be sure it only binds to the detection antibody, and not the capture antibody bound to the plate. This would result in a measurable product in all wells, regardless of the presence or absence of antigen or detection antibody.
Finally, the competitive ELISA assay is used to detect soluble antigens. It is simple to perform, but it is only suitable when the purified antigen is available in a relatively large amount. The general procedure for the competitive ELISA assay is:
The "competition" in this assay comes from the fact that more antigen in the test sample used in step 3 will result in less antibody available to bind to the antigen coating the well. Thus, the intensity of the chromogenic/fluorogenic product in the well at the end of the assay is inversely related to the amount of antigen present in the test sample.
A key component in any type of ELISA is the titrated standards of known concentrations that will allow the user to determine the antigen concentration present in the test samples. Typically, a series of wells are designated for creating a standard curve, where known amounts of a purified recombinant protein are added to the wells in decreasing amounts. When these wells are processed at the same time as the test samples, the user can then have a reference set of absorbance values obtained from a microplate reader for known protein concentrations to go along with the absorbance values for the test samples. The user can then calculate a standard curve to which the test samples can be compared for determining the amount of protein of interest present. The standard curve can also determine the degree of precision of the user's dilution making.
Finally, the last step in each of the ELISA types listed above calls for the addition of a substrate. The degree of conversion of the substrate to product is directly related to the amount of enzyme present in the well. Horseradish peroxidase (HRP) and alkaline phosphatase (AP) are the most common enzymes found conjugated to antibodies. As expected, there are a number of substrates available specific for either enzyme that produce a chromogenic or fluorescent product. Moreover, substrates are available in a range of sensitivities that can increase the overall sensitivity of the assay. The user must also take into consideration the type of instrumentation available for reading the plate at the end of the experiment when picking the type of substrate to use, along with its corresponding enzyme-conjugated antibody.
Commonly used chromogenic substrates for HRP include 2,2'-Azinobis [3-ethylbenzothiazoline-6-sulfonic acid]-diammonium salt (ABTS) and 3,3',5,5'-tetramethylbenzidine (TMB), whereas p-Nitrophenyl Phosphate (PNPP) is used for AP. ABTS and TMB produce water-soluble green and blue colored reaction products, respectively. The green ABTS product has two major absorbance peaks, 410 and 650 nm, while the blue TMB product is best detected at 370 and 652 nm. The colors of ABTS and TMB change to yellow upon the addition of an acidic stop solution, which is best read at 450 nm. Color development for ABTS is slow, while it is fast for TMB. TMB is more sensitive than ABTS, and may produce a higher background signal if the enzymatic reaction proceeds too long. PNPP produces a yellow water-soluble product after AP conversion that absorbs light at 405 nm.
1. Indirect ELISA
An indirect ELISA is one where the primary antigen-specific antibody is recognized by a secondary conjugated antibody. The following protocol is an example of an indirect ELISA method, where the serum samples of of influenza A virus (IAV)-infected mice are tested for the presence of IAV-specific IgG antibody. One strength of this example is that different secondary antibodies can be used that recognize all antibody isotypes or specific isotypes (e.g., IgG).
Coating antigen to the microplate
Blocking
Incubation with the primary antibody
Incubation with the secondary antibody
Detection
2. Sandwich ELISA
In this ELISA version, the experimental sample is "sandwiched" between an unconjugated capture antibody and a conjugated detection antibody, both of which are specific to the same protein but at different epitopes. In the following sandwich ELISA example, concentration of human TNFα was determined in unknown sample using a standard curve generated from 2.5X serial dilution of a known standard, recombinant human TNFα (stating at concentration of 75 pg/mL).
Coating capture antibody to the microplate
Blocking
Add antigen containing test samples
Add enzyme-conjugated detection antibody
Detection
3. Competitive ELISA
The steps of a competitive ELISA are different from those used in indirect and sandwich ELISA, with the main difference being the competitive binding step between the sample antigen and the "add-in" antigen. The sample antigen is incubated with the unlabeled primary antibody. These antibody-antigen complexes are then added to the ELISA plate, which has been pre-coated with the same antigen. After an incubation period, any unbound antibody is washed away. There is an inverse correlation between the amount of free antibody available to bind the antigen in the well and the amount of antigen in the original sample. For example, a sample with abundant antigen would have more antigen-primary antibody complexes, leaving little unbound antibody to bind to the ELISA plate. An enzyme-conjugated secondary antibody specific to the primary antibody is then added to the wells, followed by the substrate.
Coating antigen to the microplate
Blocking
Incubation sample (antigen) with the primary antibody
Add antigen-antibody mixture to the well
Add the secondary antibody
Detection
Enzyme-linked Immunosorbent Assay, or ELISA is a highly sensitive quantitative assay commonly used to measure the concentration of an analyte like cytokines and antibodies in a biological sample. The general principle of this assay involves three steps: starting with capture, or immobilization, of the target analyte on a micro plate, followed by the detection of the analyte by target-specific detection proteins, and lastly, enzyme reaction, where a conjugated enzyme converts its substrate to a colored product. Based on different methods of capture and detection, ELISA can be of four types: direct, indirect, sandwich, and competitive.
For direct ELISA, the target antigen is first bound to the plate, and is then detected by a specific detection antibody. This method is commonly used for screening antibodies for a specific antigen. Indirect ELISA is used for detecting antibodies in a sample in order to quantify immune responses. The plate is first coated with a specific capture antigen, which immobilizes the target antibody, and this antigen-antibody complex is then detected using a second antibody.
In the case of sandwich ELISA, the target analyte is an antigen, which is captured on the plate using a capture antibody and then detected by the detection antibody, hence forming an antibody-antigen-antibody sandwich. This method is useful for measuring the concentration of an antigen in a mixed sample.
Competitive ELISA is used when only one antibody is available for a target antigen of interest. The plate is first coated with the purified antigen. Meanwhile, the sample containing the antigen is pre-incubated with the antibody and then added to the plate, to allow any free antibody molecules to bind to the immobilized antigen. The higher the signal from the plate, the lower the antigen concentration in the sample. In all of the four types of ELISA, direct, indirect, sandwich, and competitive, the detection antibody is either directly conjugated to the enzyme or can be indirectly linked to it through another antibody or protein.
The enzymes commonly used for the reaction are horseradish peroxidase or alkaline phosphatase with their respective substrates, both producing a soluble, colored product that can be measured and quantified using a plate reader. In this video, you will observe how to perform indirect ELISA, sandwich ELISA, and competitive ELISA, followed by examples of quantification of the target analyte from the indirect and sandwich ELISA methods.
The first experiment will demonstrate how to use indirect ELISA to determine the presence of anti-influenza virus antibodies in serum obtained from influenza-infected mice.
To begin, add 50 microliters of purified antigen – in this case, 2 milligrams per milliliter of purified A/PR/8 Influenza A virus- to each well of a 96-well ELISA plate. Next, cover the plate with an adhesive cover and incubate it overnight at 4 degrees celsius to allow the antigen to bind to the plate. The following day, remove the coating solution by flicking the plate over a sink. Next, block the remaining protein-binding sites in the coated wells by adding 200 microliters of a blocking buffer- here, 5% donkey serum in 1X PBS- to each well. Leave the plate to incubate for at least 2 hours at room temperature. Following the incubation, remove the blocking buffer and then wash the plate by adding 200 microliters of 1X PBS containing 1% Tween-20. Flick the plate over the sink once more to remove the wash.
Then, prepare the test samples by adding 460 microliters of PBS to a fresh tube, and then adding 40 microliters of serum to make a 1 to 12.5 dilution. Then, add 300 microliters of PBS to a second tube, and then add 100 microliters of the first dilution. Continue this serial dilution range until obtaining a final sample with a dilution of 1 to 204,800. Add the serially diluted serum samples in triplicate to the wells. Cover the plate with an adhesive cover and incubate at room temperature for an hour. Next, remove the samples by flicking the plate into the sink and then wash the plate by adding 200 microliters of 1X PBS containing 1% Tween-20. Once again, flick the plate to remove the wash.
Now, add 100 microliters of an enzyme-conjugated secondary antibody, which in this experiment is a horseradish peroxidase, or HRP, conjugated donkey anti-mouse secondary, to each well. Incubate the plate for one hour at room temperature, and flick the plate to remove any excess liquid. Wash the plate with 1X PBS containing 1% Tween-20 and then apply 100 microliters of the indicator substrate at a concentration of one milligram per milliliter to each well. Incubate the plate with the substrate for 5 to 10 minutes at room temperature. In this example, the colorless 3,3', 5,5' – tetramethylbenzidine, or TMB, substrate turns a blue color when HRP is present. After 10 minutes, stop the enzymatic reaction by adding 100 microliters of 2N sulfuric acid. The samples will turn a yellow color.
Within 30 minutes of adding the stop solution, insert the plate into a microplate reader and read the plate at the appropriate wavelength for the substrate to determine the absorbance of the wells.
To begin the sandwich ELISA, the plate must be coated with purified capture antibody. To do this, add 100 microliters of the capture antibody at a concentration within the 1-10 microgram per milliliter range, to each well of a 96-well ELISA plate. Next, cover the plate with an adhesive plate cover and then incubate the plate overnight at 4 degrees celsius. After the incubation, remove the coating solution by flicking the plate over a sink.
Now, block the remaining protein- binding sites in the coated wells by adding 200 microliters of 5% nonfat dry milk to the wells. Incubate the plate at room temperature for at least 2 hours. Next, remove the blocking buffer, and then wash the wells with 1X PBS containing 1% Tween-20. Remove the wash by flicking the plate over the sink. Now, add 100 microliters of the test sample to the wells, seal the plate with an adhesive cover, and then incubate it at room temperature for 2 hours. After incubation, remove the samples by flicking the plate over the sink and then wash the wells with 200 microliters of 1X PBS containing 1% Tween-20. Flick the plate over the sink to remove the wash and then add 100 microliters of enzyme-conjugated detection antibody to the wells.
Seal the plate with an adhesive cover. Leave the plate to incubate at room temperature for 2 hours. After the incubation, remove the unbound detection antibody by flicking the plate over a sink and wash the wells with 200 microliters of 1X PBS containing 1% Tween-20. Next, add 100 microliters of the indicator substrate at a concentration of 1 milligram per milliliter, and incubate the plate for 5 to 10 minutes at room temperature. After 10 minutes, stop the enzymatic reaction by adding 100 microliters of 2N sulfuric acid to the wells and then read the plate within 30 minutes of adding the stop solution in a microplate reader.
To perform a competitive ELISA, first coat the wells of a 96-well ELISA plate with 100 microliters of purified antigen at a concentration of 1-10 micrograms per milliliter. Cover the plate with an adhesive plate cover and then incubate overnight at 4 degrees celsius. Following this, remove the unbound antigen solution from the wells by flicking the plate over a sink.
Next, block the remaining protein-binding sites in the coated wells by adding 200 microliters of blocking buffer to each well- here, 5% nonfat dry milk in PBS. Incubate the plate for at least 2 hours at room temperature. While blocking the wells, prepare the antigen-antibody mixture in a 1. 5 milliliter tube by adding 150 microliters of sample antigen to 150 microliters of primary antibody for each well in the assay. Incubate this mixture for 1 hour at 37 degrees celsius. Now, remove the blocking buffer from the wells by flicking the plate over a sink. Then, wash the wells with 1X PBS containing Tween 20 and then add 100 microliters of the sample antigen- primary antibody mixture.
Leave the plate to incubate at 37 degrees celsius for one hour. Next, remove the sample mixture by flicking the plate over a sink and then wash the wells with 1X PBS containing 1% Tween-20 to remove any unbound antibody. Add 100 microliters of an enzyme-conjugated secondary antibody to each well and incubate the plate for one hour at 37 degrees celsius. Following this, wash the plate with 1X PBS containing 1% Tween-20 and then add 100 microliters of the substrate solution to each well. Wait for 5-10 minutes. After 10 minutes, stop the enzymatic reaction by adding 100 microliters of 2N sulfuric acid and then measure the absorbance in a microplate reader within 30 minutes of adding the stop solution.
For the semi-quantitative indirect ELISA assay, the presence of influenza A virus antibodies in serially diluted samples of serum from influenza A- infected mice was determined by reading the absorbance of each well at 405 nanometers in a plate reader. This raw data is exported to a spread sheet for calculation purposes. In this experiment, the serially diluted serum samples, which range from 1 – 12.5, to 1 – 204,800, were repeated in triplicate.
To analyze the data, the mean absorbance value is therefore calculated for each set of triplicates by adding all the values for each dilution and dividing the sum by 3. Once the mean for each set of triplicates is determined, the mean OD450 readings are plotted against the serial dilutions. The OD readings decrease as the serum is diluted, indicating that less antibodies are found in the more diluted samples. In the quantitative sandwich ELISA, dilutions of known standard, in this case recombinate Human TNFalpha, were added to a 96-well plate and read along with the unknown samples.
To create the standard curve, the mean absorbance value for each set of readings of the known concentrations was calculated. Then, the mean absorbance value was plotted on the y-axis, against the known protein concentrations on the x-axis. A best fit curve is added through the points in the graph.
Once the standard curve is generated, the amount of TNFalpha protein in the test sample can be determined by first calculating the mean absorbance value for the test sample. In this example, the test samples gave OD450 readings of 0.636 and 0. 681. Adding these values and dividing the sum by 2 gives an average of 0.659. From the y-axis on the standard curve graph, extend a horizontal line from this absorbance value to the standard curve. At the point of intersection, extend a vertical line to the x-axis and read the corresponding concentration which, in this test sample, corresponds to a TNFalpha concentration of 38.72 picograms per milliliter.
In the following example of an indirect ELISA, the presence of influenza A virus (IAV)-specific IgG in the serum of IAV-infected mice was determined. C57Bl/6 mice were infected with influenza A virus (A/PR/8; 105 PFU in 100 µL PBS i.p.) and serum was collected 28 days later. To quantitate the amount of IAV-specific IgG in the serum, 96-well ELISA plates were coated with purified A/PR/8 Influenza A virus (50 µL/well of 2 mg/ml PBS virus) overnight at 4°C. Coated plates were blocked for 1 hour at room temperature with 5% normal donkey serum in PBS, followed by incubation with diluted serum samples from IAV-challenged mice overnight at 4°C. The serum was initially diluted 1:12.5, followed by 1:4 dilutions (dilution range – 1:12.5 to 1:204,800). After washing, plates were incubated with an alkaline phosphatase (AP)-conjugated donkey anti-mouse IgG for 1 h. The plates were washed, and then p-Nitrophenyl Phosphate (PNPP; 1 mg/mL, 100 µL/well) was added. The colorless PNPP solution turns to a yellow color when AP is present. After 5-10 min, the enzymatic reaction was stopped by adding 100 µL/well 2N H2SO4. The plate was read on a microplate reader at 405 nm. The results obtained are shown in Table 1 and Figure 1.
Sample | Wells | OD405 | Mean |
Serum 1:12.5 | A1 | 2.163 | 2.194 |
B1 | 2.214 | ||
C1 | 2.204 | ||
Serum 1:50 | A1 | 1.712 | 1.894 |
B1 | 2.345 | ||
C1 | 1.624 | ||
Serum 1:200 | A1 | 1.437 | 1.541 |
B1 | 1.73 | ||
C1 | 1.456 | ||
Serum 1:800 | A1 | 1.036 | 0.957 |
B1 | 0.912 | ||
C1 | 0.923 | ||
Serum 1:3200 | A1 | 0.579 | 0.48 |
B1 | 0.431 | ||
C1 | 0.429 | ||
Serum 1:12800 | A1 | 0.296 | 0.281 |
B1 | 0.312 | ||
C1 | 0.236 | ||
Serum 1:51200 | A1 | 0.308 | 0.283 |
B1 | 0.299 | ||
C1 | 0.243 | ||
Serum 1:204800 | A1 | 0.315 | 0.303 |
B1 | 0.298 | ||
C1 | 0.297 |
Table 1: Indirect ELISA assay data. Serum dilutions (from 1:12.5 to 1:204,800), of influenza A virus (IAV)-infected mice containing IAV-specific IgG, optical density (OD) (405 nm) values and mean OD405 values.
Figure 1: Indirect ELISA assay scatter plot of mean OD405 values(+ S. D.) and serum dilutions (from 1:12.5 to 1:204,800), of influenza A virus (IAV)-specific IgG in the serum of IAV-infected mice. The OD405 values can be inversely correlated to the serum dilutions.
In the following example of a sandwich ELISA, a 1:2.5 dilution of recombinant human TNFα standards (starting at a concentration of 75 pg/mL) was added to the indicated wells of a 96-well flat-bottom plate. These standards led to a corresponding 2.5-fold change in the absorbance readings.
Sample | Concentration (pg/mL) | Wells | Values | Mean Value | Back Concentration Calculation | Average |
Standard 1 | 75 | A1 | 1.187 | 1.169 | 76.376 | 75.01 |
A2 | 1.152 | 73.644 | ||||
Standard 2 | 30 | B1 | 0.534 | 0.52 | 30.827 | 29.962 |
B2 | 0.506 | 29.098 | ||||
Standard 3 | 12 | C1 | 0.23 | 0.217 | 12.838 | 12.105 |
C2 | 0.204 | 11.372 | ||||
Standard 4 | 4.8 | D1 | 0.09 | 0.084 | 5.055 | 4.726 |
D2 | 0.078 | 4.398 | ||||
Standard 5 | 1.92 | E1 | 0.033 | 0.031 | 1.941 | 1.86 |
E2 | 0.03 | 1.778 | ||||
Standard 6 | 0.768 | F1 | 0.009 | 0.011 | 0.626 | 0.764 |
F2 | 0.014 | 0.901 | ||||
Standard 7 | 0.307 | G1 | 0.002 | 0.004 | 0.238 | 0.377 |
G2 | 0.007 | 0.516 |
Table 2: TNFα Sandwich ELISA standard curve data. A 1:2.5 dilution of recombinant human TNFα standards (75 to 0.3 pg/mL), OD (450 nm) values, mean OD450 values, back concentration calculations and their averages.
Figure 2: Standard Curve for TNFα sandwich ELISA. A 1:2.5 dilution of recombinant human TNFα standards (75 to 0.3 pg/mL) was analyzed using sandwich ELISA.The OD450 values can be directly correlated to the standard dilution concentrations. The amount of TNFα protein in the test sample was determined using the standard curve, which corresponds to a concentration of 38.72 pg/mL.
Once the standard curve was generated, the amount of TNFα protein in the test sample was determined. In this sandwich ELISA example, the test samples gave OD450 readings of 0.636 and 0.681, which give an average of 0.6585. When plotting this OD450 reading on the above chart, this corresponds to a TNFα concentration of 38.72 pg/ml.
As demonstrated, a range of immunoassays (with slight variation in protocols) fall within the ELISA technique family. Determining which version of ELISA to use depends on a number of factors, including what antigen is being detected, the monoclonal antibody available for a particular antigen, and the desired sensitivity of the assay (5). Some strengths and weaknesses of the different ELISAs described herein are:
ELISA | Strengths | Weaknesses |
Indirect | 1) High sensitivity due to the fact that multiple enzyme-conjugated secondary antibodies can bind to the primary antibody | 1) High background signal may occur because the coating of the antigen of interest to the plate is not specific (i.e., all proteins in the sample will coat the plate) |
2) Many different primary antibodies can be recognized by a single enzyme-conjugated secondary antibody giving the user the flexibility of using the same enzyme-conjugated secondary antibody in many different ELISA (regardless of the antigen being detected) | ||
3) Best choice when only a single antibody for the antigen of interest is available | ||
Sandwich | 1) The use of antigen-specific capture and detection monoclonal antibody increases the sensitivity and specificity of the assay (compared to the indirect ELISA) | 1) Optimizing the concentrations of the capture and detection monoclonal antibodies can be difficult (especially for non-commercial kits) |
2) Best choice for detecting a large protein with multiple epitopes (such as a cytokine) | ||
Competitive | 1) Impure samples can be used | 1) Requires a large amount of highly pure antigen to be used to coat plate |
2) Less sensitivity to reagent dilution effects | ||
3) Ideal for detecting small molecules (such as a hapten) |
Table 3: Summary. A summary of the strengths and weaknesses of the different ELISA techniques.
While a simple and useful technique, there are also some drawbacks to any ELISA. One is the uncertainty of the amount of the protein of interest in the test samples. If the amount is too high or too low, the absorbance values obtained by the microplate reader may fall above or below the limits of the standard curve, respectively. This will make it difficult to accurately determine the amount of protein present in the test samples. If the values are too high, the test sample can be diluted prior to adding to the wells of the plate. The final values would then need to be adjusted according to the dilution factor. As mentioned, homemade kits often require careful optimization of the antibody concentrations used to yield a high signal-to-noise ratio.
Enzyme-linked Immunosorbent Assay, or ELISA is a highly sensitive quantitative assay commonly used to measure the concentration of an analyte like cytokines and antibodies in a biological sample. The general principle of this assay involves three steps: starting with capture, or immobilization, of the target analyte on a micro plate, followed by the detection of the analyte by target-specific detection proteins, and lastly, enzyme reaction, where a conjugated enzyme converts its substrate to a colored product. Based on different methods of capture and detection, ELISA can be of four types: direct, indirect, sandwich, and competitive.
For direct ELISA, the target antigen is first bound to the plate, and is then detected by a specific detection antibody. This method is commonly used for screening antibodies for a specific antigen. Indirect ELISA is used for detecting antibodies in a sample in order to quantify immune responses. The plate is first coated with a specific capture antigen, which immobilizes the target antibody, and this antigen-antibody complex is then detected using a second antibody.
In the case of sandwich ELISA, the target analyte is an antigen, which is captured on the plate using a capture antibody and then detected by the detection antibody, hence forming an antibody-antigen-antibody sandwich. This method is useful for measuring the concentration of an antigen in a mixed sample.
Competitive ELISA is used when only one antibody is available for a target antigen of interest. The plate is first coated with the purified antigen. Meanwhile, the sample containing the antigen is pre-incubated with the antibody and then added to the plate, to allow any free antibody molecules to bind to the immobilized antigen. The higher the signal from the plate, the lower the antigen concentration in the sample. In all of the four types of ELISA, direct, indirect, sandwich, and competitive, the detection antibody is either directly conjugated to the enzyme or can be indirectly linked to it through another antibody or protein.
The enzymes commonly used for the reaction are horseradish peroxidase or alkaline phosphatase with their respective substrates, both producing a soluble, colored product that can be measured and quantified using a plate reader. In this video, you will observe how to perform indirect ELISA, sandwich ELISA, and competitive ELISA, followed by examples of quantification of the target analyte from the indirect and sandwich ELISA methods.
The first experiment will demonstrate how to use indirect ELISA to determine the presence of anti-influenza virus antibodies in serum obtained from influenza-infected mice.
To begin, add 50 microliters of purified antigen – in this case, 2 milligrams per milliliter of purified A/PR/8 Influenza A virus- to each well of a 96-well ELISA plate. Next, cover the plate with an adhesive cover and incubate it overnight at 4 degrees celsius to allow the antigen to bind to the plate. The following day, remove the coating solution by flicking the plate over a sink. Next, block the remaining protein-binding sites in the coated wells by adding 200 microliters of a blocking buffer- here, 5% donkey serum in 1X PBS- to each well. Leave the plate to incubate for at least 2 hours at room temperature. Following the incubation, remove the blocking buffer and then wash the plate by adding 200 microliters of 1X PBS containing 1% Tween-20. Flick the plate over the sink once more to remove the wash.
Then, prepare the test samples by adding 460 microliters of PBS to a fresh tube, and then adding 40 microliters of serum to make a 1 to 12.5 dilution. Then, add 300 microliters of PBS to a second tube, and then add 100 microliters of the first dilution. Continue this serial dilution range until obtaining a final sample with a dilution of 1 to 204,800. Add the serially diluted serum samples in triplicate to the wells. Cover the plate with an adhesive cover and incubate at room temperature for an hour. Next, remove the samples by flicking the plate into the sink and then wash the plate by adding 200 microliters of 1X PBS containing 1% Tween-20. Once again, flick the plate to remove the wash.
Now, add 100 microliters of an enzyme-conjugated secondary antibody, which in this experiment is a horseradish peroxidase, or HRP, conjugated donkey anti-mouse secondary, to each well. Incubate the plate for one hour at room temperature, and flick the plate to remove any excess liquid. Wash the plate with 1X PBS containing 1% Tween-20 and then apply 100 microliters of the indicator substrate at a concentration of one milligram per milliliter to each well. Incubate the plate with the substrate for 5 to 10 minutes at room temperature. In this example, the colorless 3,3′, 5,5′ – tetramethylbenzidine, or TMB, substrate turns a blue color when HRP is present. After 10 minutes, stop the enzymatic reaction by adding 100 microliters of 2N sulfuric acid. The samples will turn a yellow color.
Within 30 minutes of adding the stop solution, insert the plate into a microplate reader and read the plate at the appropriate wavelength for the substrate to determine the absorbance of the wells.
To begin the sandwich ELISA, the plate must be coated with purified capture antibody. To do this, add 100 microliters of the capture antibody at a concentration within the 1-10 microgram per milliliter range, to each well of a 96-well ELISA plate. Next, cover the plate with an adhesive plate cover and then incubate the plate overnight at 4 degrees celsius. After the incubation, remove the coating solution by flicking the plate over a sink.
Now, block the remaining protein- binding sites in the coated wells by adding 200 microliters of 5% nonfat dry milk to the wells. Incubate the plate at room temperature for at least 2 hours. Next, remove the blocking buffer, and then wash the wells with 1X PBS containing 1% Tween-20. Remove the wash by flicking the plate over the sink. Now, add 100 microliters of the test sample to the wells, seal the plate with an adhesive cover, and then incubate it at room temperature for 2 hours. After incubation, remove the samples by flicking the plate over the sink and then wash the wells with 200 microliters of 1X PBS containing 1% Tween-20. Flick the plate over the sink to remove the wash and then add 100 microliters of enzyme-conjugated detection antibody to the wells.
Seal the plate with an adhesive cover. Leave the plate to incubate at room temperature for 2 hours. After the incubation, remove the unbound detection antibody by flicking the plate over a sink and wash the wells with 200 microliters of 1X PBS containing 1% Tween-20. Next, add 100 microliters of the indicator substrate at a concentration of 1 milligram per milliliter, and incubate the plate for 5 to 10 minutes at room temperature. After 10 minutes, stop the enzymatic reaction by adding 100 microliters of 2N sulfuric acid to the wells and then read the plate within 30 minutes of adding the stop solution in a microplate reader.
To perform a competitive ELISA, first coat the wells of a 96-well ELISA plate with 100 microliters of purified antigen at a concentration of 1-10 micrograms per milliliter. Cover the plate with an adhesive plate cover and then incubate overnight at 4 degrees celsius. Following this, remove the unbound antigen solution from the wells by flicking the plate over a sink.
Next, block the remaining protein-binding sites in the coated wells by adding 200 microliters of blocking buffer to each well- here, 5% nonfat dry milk in PBS. Incubate the plate for at least 2 hours at room temperature. While blocking the wells, prepare the antigen-antibody mixture in a 1. 5 milliliter tube by adding 150 microliters of sample antigen to 150 microliters of primary antibody for each well in the assay. Incubate this mixture for 1 hour at 37 degrees celsius. Now, remove the blocking buffer from the wells by flicking the plate over a sink. Then, wash the wells with 1X PBS containing Tween 20 and then add 100 microliters of the sample antigen- primary antibody mixture.
Leave the plate to incubate at 37 degrees celsius for one hour. Next, remove the sample mixture by flicking the plate over a sink and then wash the wells with 1X PBS containing 1% Tween-20 to remove any unbound antibody. Add 100 microliters of an enzyme-conjugated secondary antibody to each well and incubate the plate for one hour at 37 degrees celsius. Following this, wash the plate with 1X PBS containing 1% Tween-20 and then add 100 microliters of the substrate solution to each well. Wait for 5-10 minutes. After 10 minutes, stop the enzymatic reaction by adding 100 microliters of 2N sulfuric acid and then measure the absorbance in a microplate reader within 30 minutes of adding the stop solution.
For the semi-quantitative indirect ELISA assay, the presence of influenza A virus antibodies in serially diluted samples of serum from influenza A- infected mice was determined by reading the absorbance of each well at 405 nanometers in a plate reader. This raw data is exported to a spread sheet for calculation purposes. In this experiment, the serially diluted serum samples, which range from 1 – 12.5, to 1 – 204,800, were repeated in triplicate.
To analyze the data, the mean absorbance value is therefore calculated for each set of triplicates by adding all the values for each dilution and dividing the sum by 3. Once the mean for each set of triplicates is determined, the mean OD450 readings are plotted against the serial dilutions. The OD readings decrease as the serum is diluted, indicating that less antibodies are found in the more diluted samples. In the quantitative sandwich ELISA, dilutions of known standard, in this case recombinate Human TNFalpha, were added to a 96-well plate and read along with the unknown samples.
To create the standard curve, the mean absorbance value for each set of readings of the known concentrations was calculated. Then, the mean absorbance value was plotted on the y-axis, against the known protein concentrations on the x-axis. A best fit curve is added through the points in the graph.
Once the standard curve is generated, the amount of TNFalpha protein in the test sample can be determined by first calculating the mean absorbance value for the test sample. In this example, the test samples gave OD450 readings of 0.636 and 0. 681. Adding these values and dividing the sum by 2 gives an average of 0.659. From the y-axis on the standard curve graph, extend a horizontal line from this absorbance value to the standard curve. At the point of intersection, extend a vertical line to the x-axis and read the corresponding concentration which, in this test sample, corresponds to a TNFalpha concentration of 38.72 picograms per milliliter.