'Dergi'
/
/
Emission Spectroscopic Boundary Layer Investigation during Ablative Material Testing in Plasmatron
JoVE Journal
Mühendislik
This content is Free Access.
JoVE Journal Mühendislik
Emission Spectroscopic Boundary Layer Investigation during Ablative Material Testing in Plasmatron
DOI:

09:41 min

June 09, 2016

, , ,

'Bölümler'

  • 00:05'Başlık'
  • 01:06Measurement Techniques Setup
  • 03:07Experimental Testing
  • 05:24Spectrometer Calibration and Data Processing
  • 06:36Post-test Sample Inspection
  • 07:10Results: Emission Spectroscopic Boundary Layer Analysis during Ablative Material Testing
  • 08:37Conclusion

Özet

'Otomatik Çeviri'

Development of new ablative materials and their numerical modeling requires extensive experimental investigation. This protocol describes procedures for material response characterization in plasma flows with the core techniques being non-intrusive methods to track the material recession along with the chemistry in the reactive boundary layer by emission spectroscopy.

'İlgili Videolar'

Read Article