– A Y-maze consists of a Y-shaped connector with three fly vials connected için it by straight or tapered tubes. Flies move through the maze toward the side with the stimulus that they prefer. To start the experiment, place a tissue paper with the solution containing the volatile chemicals into each vial. Then, connect them için the tapered tubes. The tapered tubes limit the ability of the flies için return için the center of the maze and slows the diffusion of the volatile chemicals.
Next, chill starved flies için slow them down. Do not use chemical anesthesia, as this may affect the outcome of the assay. Quickly connect the vial with the chilled flies için the final side of the maze. Leave the flies için explore the maze. To reduce any preference caused by bright light, carry out this step under far-red light, which flies do not see. Finally, count the flies on each side of the maze. Their location videodan the maze indicates their preference toward that volatile chemical scent.
In the example protocol, we will see a setup of the Y-maze assay with wild type Drosophila.
– Before conducting the assay the following morning, at the end of the day, transfer cohorts of 10 için 20 experimental lines için glass vials with moisture provided from a wet towel. The flies must be tested videodan 16 için 18 hours, or they could die due için desiccation or starvation. The next day, assemble the Y-maze. Start by joining the Y-shaped connector için two glass vials using foam connectors with trimmed pipette tips which make the conduits. Their tapering shape makes these one-way passages.
The third branch of the “Y” is attached için a loading tube, made from the large portion of a pipette tip, and allows passage from the loading vial için the choice point of the maze. Beyond each tapering tunnel is a glass vial, one of which must be loaded with an odorant. Load these as 40-microliter boluses soaked into 28-millimeter squares of tissue paper. Which of the two contains the odorant should alternate randomly.
To conduct the test, first cool the flies on ice briefly, so the flies are slowed down. This should be under far-red light from LED bulbs and at 25 degrees Celsius. Gently drop the cohort of flies into the loading vial and load the Y-maze with the test flies. Do not use gas anesthesia.
– It is really critical için transfer the flies için the loading vial both quickly and gently. It is actually the most difficult step of this experiment because flies have to wake up rapidly before the diffusion of odors in the Y-maze.
– The flies should be allowed için explore the maze for 24 hours, so a maximum number of flies move için one or the other glass vial. The number of flies present videodan the different tubes serves için calculate the olfactory index. Standard statistical methods should be applied için this value, gathered from the behavior of up için 10 flies.
If 10-fly cohorts are not providing consistent results, the trials can be run with 20-fly cohorts. To clean up the maze components, soak them, dismantled, in RBS 35 MD overnight. Follow this with rinses videodan tap water and a final rinse videodan DI water before air drying.