Source: Ali Bazzi, Department of Electrical Engineering, University of Connecticut, Storrs, CT.

A flyback converter is a buck-boost converter, which can both buck and boost. It has electrical isolation between the input and the output using a coupled inductor or a "flyback transformer." This coupled inductor enables a turns ratio that provides both voltage step-up and step-down capability, like in a regular transformer but with energy storage using the air-gap of the coupled inductor.

The objective of this experiment is to study different characteristics of a flyback converter. This converter operates like a buck-boost converter but has electrical isolation through a coupled inductor. Open-loop operation with a manually-set duty ratio will be used. An approximation of the input-output relationship will be observed.

İlkeler

To better understand the flyback converter, first, one must understand a buck-boost converter. The flyback converter circuit can then be derived from the buck-boost converter.

The buck-boost converter, as its name implies, can either step-up or step-down a DC voltage input to higher or lower voltage, respectively. To derive a buck-boost converter circuit, a buck and boost converter are cascaded as shown in Fig. 1 (a). A current source/sink is used as the load for the buck converter and input to the boost converter, causing the boost converter to be flipped to maintain the input voltage polarity. Buck-boost converters thus have a reversed output voltage polarity.

As can be seen in Fig. 1 (b), the current source/sink can be replaced with a large inductor that acts as a current source or sink. However, "C1" is no longer needed, as the intermediate voltage across "L3" does not have to have a very small ripple voltage. Also Switch 2 is no longer needed since it may cause a short-circuit across "L2" and "L3." The circuit is thus updated as shown in Fig. 1 (c).

Also, Diode 1 was used in the buck converter to provide a current path for the inductor "L1," but "L1" and "L2" can be removed since a smooth current is no longer needed in the intermediate stage. Diode 1 can thus also be removed, as shown in Fig. 1 (d) and (e). The bottom-side Diode 2 can be moved to the top side or left on the bottom side, as shown in Fig. 1 (e) which is the most common buck-boost converter circuit implementation.

Figure 1
Figure 1. Derivation of a buck-boost converter circuit from cascaded buck and boost converters

The flyback converter goes one step further than the buck-boost converter by providing electrical isolation between the input and output voltages. This is desired in many power supply applications where grounds on the source and load sides need to be separated. Typically, flyback converters are used in ratings up to 200 W. The schematic shown in Fig. 2 illustrates how a flyback converter is derived from a buck-boost converter.

When the switch is on in a buck-boost converter, the diode is reverse biased and energy is stored in the inductor. When the switch is off, the inductor can either absorb energy from the capacitor once the diode is on, or can supply the capacitor and load with energy. This provides the step-down and step-up flexibility. However, the inductor can be replaced with a coupled inductor or flyback transformer to provide electrical isolation with the output side as shown in Fig. 2 (b). The switch being on the top side requires a high-side gate driver circuit, which is more elaborate and requires more components than a low-side circuit. Therefore, the switch can simply be moved such that one of its terminals is grounded and thus it requires a simple low-side gate driver as shown in Fig. 2 (c). In order to have the input and output voltage polarities on the same side, the output diode is reversed along with the transformer's polarity. The final flyback converter is shown in Fig. 2 (d).

Figure 2
Figure 2. Derivation of a flyback converter circuit from a buck-boost converter circuit

Prosedür

ATTENTION: This experiment is designed to limit the output voltage to be less than 50V DC. Only use duty ratios, frequencies, input voltage, or loads that are given here.

This experiment will utilize the DC-DC converter board provided by HiRel Systems. http://www.hirelsystems.com/shop/Power-Pole-Board.html

Information about the board operation can be found in this collections video “Introduction to the HiRel Board.”

The procedure shown here applies to any simple flyback converter circuit that can be built on proto boards, bread boards, or printed circuit boards.

1. Board setup:

  1. Connect the ±12 signal supply at the "DIN" connector but keep "S90" OFF.
  2. Make sure that the PWM control selector is in the open-loop position.
  3. Set the DC power supply at 16 V. Keep its output disconnected from the board for now.
  4. Before connecting the load resistor, adjust it to 10 Ω.
  5. Build the circuit shown in Fig. 3 by using the lower MOSFET and flyback magnetic board.
    1. Note that the turns ratio N1/N2=2.
  6. Connect "RL" across "V2+" and "COM."
    1. NEVER Disconnect the load during the experiment as the boost converter can become unstable and cause damage to the board.
  7. Make sure the switch array for MOSFET selection (lower MOSGET), PWM selection, and other settings are correct to achieve a functional Fig. 3.

Figure 1
Figure 3. Flyback converter circuit

2. Adjusting the Duty Ratio and Switching Frequency

  1. Connect the differential probe across the gate-to-source of the lower MOSFET.
  2. Turn ON "S90." A switching signal should appear on the scope screen.
    1. Adjust the signal time axis to see two or three periods.
    2. Adjust the frequency potentiometer to achieve a frequency of 100 kHz (period of 10 µs).
  3. Adjust the duty ratio potentiometer to achieve a 50% duty ratio (on-time of 5 µs).

3. Flyback Converter Testing for Variable Input

  1. Connect the input DC power supply, which is already set at 16 V, to "V1+" and "COM."
  2. Connect a regular probe to measure the input current at "CS1." Make sure the ground connector is connected to "COM."
    1. Connect the differential probe across the load.
    2. Capture the waveforms and measure the output voltage mean, input current peak, and input current mean.
    3. Record the input current and voltage readings on the DC power supply.
  3. Adjust the input voltage to 11 V, 13 V, and 15 V.
    1. Repeat the above steps for each of these voltages.
  4. Disconnect the input DC supply and adjust its output to 16 V.

4. Flyback Converter Testing for Variable Duty Ratio

  1. Connect a regular probe across the gate to source of the lower MOSFET.
  2. Connect the differential probe across the load.
  3. Connect the input DC supply to "V1+" and "COM."
  4. Capture the waveforms and measure the output voltage mean and on-time of the gate-to-source voltage (also the duty ratio).
    1. Record the input current and voltage readings on the DC power supply.
  5. Adjust the duty ratio to 10%, 25%, and 40%. Repeat the above steps for each of these three duty ratios.
  6. Reset the duty ratio to 50%.
  7. Disconnect the input DC supply.

5. Flyback Converter Testing for Variable Switching Frequency

  1. Connect a regular probe at "CS1" to measure the input current.
  2. Connect the differential probe across the load.
  3. On the second oscilloscope, observe the gate-to-source voltage using a regular probe to adjust the switching frequency as needed.
  4. Connect the input DC supply to "V1+" and "COM."
  5. Adjust the switching frequency to 70 kHz.
  6. Capture the waveforms from the first scope and measure the input current peak and output voltage mean.
    1. Record the frequency and duty ratio from the second scope but do not capture its waveform.
    2. Record the input current and voltage reading on the DC power supply.
  7. Adjust the switching frequency to 50 kHz, 30 kHz, and 10 kHz (or minimum possible if 10 kHz cannot be reached).
    1. Repeat the above steps for each of these three switching frequencies.
  8. Turn OFF the input DC supply and "S90," and then disassemble the circuit.

A flyback converter is an electrical device with the ability to generate a DC output voltage that can be either greater than or less than the DC input. If a buck converter, which steps down voltage is cascaded with a boost converter, which steps up voltage the result is a buck-boost converter. As its name implies, the buck-boost converter can either step down or step up its input voltage and is the basis of the flyback converter. The flyback converter differs from a buck-boost converter as it uses a coupled inductor, or a flyback transformer for electrical isolation between the output and input. This video will illustrate the construction of a flyback converter and investigate how changing the converter’s operating condition effects its output.

To understand how a flyback converter works, begin with a buck converter in series with a boost converter. The switches in this circuit are turned on and off by a pulse-width modulated signal. The load at the output of the buck converter is a current sink, which in turn is the input of the boost converter. In this circuit, the boost converter must be inverted so the direction of the current through the current sink is consistent with the operation of each stage. As a result, the cascaded converter has an output polarity that is reversed compared to its input. The circuit can be simplified to this buck-boost converter configuration. When the switch is closed, the voltage source drives current through the inductor. This current increases linearly with time and creates a magnetic field that stores energy in the inductor. At this time, the diode is reversed biased and does not conduct, so only the capacitor supplies energy to the load. When the switch is open, current through the inductor must continue in the same direction causing the inductor to reverse polarity. Now the diode becomes forward biased and the inductor can deliver energy to the load while at the same time charge the capacitor. When the switch closes again, the cycle repeats. Replacing the inductor with a coupled inductor or flyback transformer, provides electrical isolation between the input and output which is necessary when grounds on the source and load sides must be separated. Moving the switch from the high side of the voltage source to the low side, simplifies electrical demands on the switch and the circuit that drives it. Finally, reversing the polarity of the coupled inductor or flyback transformer, and reversing the direction of the diode, enables the polarity of the output to match the input. The result is the basic flyback converter. Now that we’ve see how to derive the flyback converter from the cascade of a buck and boost converter let’s investigate how its behavior changes with different operating conditions.

The output in this experiment is limited to 50 volts DC or less. Use only the specified duty cycles, frequencies input voltages, and loads. These experiments use the High Rel system’s Power Pole board With switch S90 turned off, plug the signal supply into connector J90. Set the pulse with modulation selection jumpers J62 and J63 to the open loop position. Adjust the DC supply to 16 volts, but do not connect its output to the power pole board. Next, build the flyback converter circuit with the lower MOSFET and the flyback magnetic board. Adjust the load resistor to 10 ohms. Then connect it to the board potentiometer between terminals V2+ and com. Set switch selector bank S30 as follows PWM to bottom MOSFET use onboard PWM and switched load off. Connect the oscilloscope’s differential probe between the gate and source of the lower MOSFET. Turn on switch S90 and observe the switching signal that turns the MOSFET on and off. Set RV60 to produce a switching frequency of 100 kilohertz. Set duty ratio potentiometer RV64 so the pulses have an on-time of five microseconds.

First, connect a regular probe between the gate and source of the lower MOSFET. Connect the differential probe across the load and connect the input DC supply to V1+ and com. The output voltage is a triangle wave resulting from the inductor and capacitor alternately supplying current to the load. The gate source voltage of the MOSFET is a digital pulse train. Measure the mean value of the output voltage and the on-time of the gate to source voltage then record the input current and voltage readings. Repeat this test with the pulse streams set to an on-time of one 2.5 and four microseconds which correspond to duty ratios of 0.1, 0.25, and 0.4, respectively. When the switch is closed, energy is stored in the inductor when the switch is open, energy is dissipated in the load. Ideally, the output increases with duty ratio however, for duty ratios above 0.5, stored energy is greater than dissipated energy, resulting in possible saturation of the core. To avoid residual energy storage, flyback converters are not operated above a duty ratio of 0.5.

Connect a regular scope probe to channel three of the oscilloscope. Clip this probe between CS1 and com to measure the input current. Observe the gate to source switching signal while adjusting potentiometer RV60 to produce a frequency of 70 kilohertz. Connect the DC power supply to input terminals V1+ and com. Observe the input current wave form and measure the mean input and output voltage. Record the frequency and duty ratio as well as the input current and voltage readings from the DC supply. Repeat this test after adjusting RV60 to a switching frequency of 50, 30, and 10 kilohertz with the duty cycle ratio fixed at 0.5. As the frequency decreases, the output ripple increases because the capacitor charge and discharge times also increase.

Flyback converters are typically used in isolated power supplies where the output must be galvanically isolated from the input. Preventing circuit damage in the event of failure and protecting users from hazardous voltages. Cell phone chargers convert the 120 volt AC main supply to an internal DC voltage that becomes the input to a flyback converter. The flyback converter in turn generates a five volt output to the standard USB connector that plugs into a cell phone and charges it. Galvanic isolation in the flyback converter protects both the cell phone and the user from contact with the 120 AC supply. In contrast, the cell phone likely uses a buck converter to reduce five volts from the charger to nominal 3.6 volts for its lithium-ion battery. For these safe low voltages, no isolation is necessary. The cathode ray tube in and older television or computer monitor uses an electron beam to illuminate phosphors on the screen. The horizontal deflection drive of CRT’s often incorporates flyback converters operating in the step up mode. The flyback converter generates the high voltage that controls this beam and moves it to strike chosen points on the screen.

You’ve just watched JoVE’s introduction to flyback converters. You should now understand how the flyback converter is related to boost and buck converters and how its behavior varies with operating condition. Thanks for watching.

Sonuçlar

Flyback converters are isolated buck-boost converters that can step up or step down the input voltage. The turns-ratio of the flyback coupled inductor or transformer aids in the stepping up or down process. Given that the switching frequency is high, the flyback transformer size is small and uses ferrite cores. If the input voltage is Vvideodan and the output voltage is Vout, Vout/Vvideodan=(N2/N1)D/(1-D) when the converter is operating in continuous conduction mode, where 0≤D≤100%. Typically, flyback converters are not operated above 50% duty cycle to maintain energy balance in the flyback transformer.

As seen in the Vout/Vvideodan relationship, D and 1/(1-D) are multiplied and show the buck and boost capabilities, while the N2/N1 term shows the effect of the transformer's turns ratio. Among the main factors in designing and building a flyback converter are 1) the magnetizing inductance Lm of the flyback transformer, and 2) the snubber circuit across the transformer's input side.

Applications and Summary

Flyback converters are typically used in isolated power supplies where the output side should have galvanic isolation from the input side. This is common in driving high-side power semiconductors such as MOSFETs and IGBTs whose gate drive circuits may require isolated DC supplies. Flyback converters are typically operated at high switching frequencies higher than 100 kHz, and have power ratings typically not exceeding 200 W.

DEŞİFRE METNİ

A flyback converter is an electrical device with the ability to generate a DC output voltage that can be either greater than or less than the DC input. If a buck converter, which steps down voltage is cascaded with a boost converter, which steps up voltage the result is a buck-boost converter. As its name implies, the buck-boost converter can either step down or step up its input voltage and is the basis of the flyback converter. The flyback converter differs from a buck-boost converter as it uses a coupled inductor, or a flyback transformer for electrical isolation between the output and input. This video will illustrate the construction of a flyback converter and investigate how changing the converter’s operating condition effects its output.

To understand how a flyback converter works, begin with a buck converter in series with a boost converter. The switches in this circuit are turned on and off by a pulse-width modulated signal. The load at the output of the buck converter is a current sink, which in turn is the input of the boost converter. In this circuit, the boost converter must be inverted so the direction of the current through the current sink is consistent with the operation of each stage. As a result, the cascaded converter has an output polarity that is reversed compared to its input. The circuit can be simplified to this buck-boost converter configuration. When the switch is closed, the voltage source drives current through the inductor. This current increases linearly with time and creates a magnetic field that stores energy in the inductor. At this time, the diode is reversed biased and does not conduct, so only the capacitor supplies energy to the load. When the switch is open, current through the inductor must continue in the same direction causing the inductor to reverse polarity. Now the diode becomes forward biased and the inductor can deliver energy to the load while at the same time charge the capacitor. When the switch closes again, the cycle repeats. Replacing the inductor with a coupled inductor or flyback transformer, provides electrical isolation between the input and output which is necessary when grounds on the source and load sides must be separated. Moving the switch from the high side of the voltage source to the low side, simplifies electrical demands on the switch and the circuit that drives it. Finally, reversing the polarity of the coupled inductor or flyback transformer, and reversing the direction of the diode, enables the polarity of the output to match the input. The result is the basic flyback converter. Now that we’ve see how to derive the flyback converter from the cascade of a buck and boost converter let’s investigate how its behavior changes with different operating conditions.

The output in this experiment is limited to 50 volts DC or less. Use only the specified duty cycles, frequencies input voltages, and loads. These experiments use the High Rel system’s Power Pole board With switch S90 turned off, plug the signal supply into connector J90. Set the pulse with modulation selection jumpers J62 and J63 to the open loop position. Adjust the DC supply to 16 volts, but do not connect its output to the power pole board. Next, build the flyback converter circuit with the lower MOSFET and the flyback magnetic board. Adjust the load resistor to 10 ohms. Then connect it to the board potentiometer between terminals V2+ and com. Set switch selector bank S30 as follows PWM to bottom MOSFET use onboard PWM and switched load off. Connect the oscilloscope’s differential probe between the gate and source of the lower MOSFET. Turn on switch S90 and observe the switching signal that turns the MOSFET on and off. Set RV60 to produce a switching frequency of 100 kilohertz. Set duty ratio potentiometer RV64 so the pulses have an on-time of five microseconds.

First, connect a regular probe between the gate and source of the lower MOSFET. Connect the differential probe across the load and connect the input DC supply to V1+ and com. The output voltage is a triangle wave resulting from the inductor and capacitor alternately supplying current to the load. The gate source voltage of the MOSFET is a digital pulse train. Measure the mean value of the output voltage and the on-time of the gate to source voltage then record the input current and voltage readings. Repeat this test with the pulse streams set to an on-time of one 2.5 and four microseconds which correspond to duty ratios of 0.1, 0.25, and 0.4, respectively. When the switch is closed, energy is stored in the inductor when the switch is open, energy is dissipated in the load. Ideally, the output increases with duty ratio however, for duty ratios above 0.5, stored energy is greater than dissipated energy, resulting in possible saturation of the core. To avoid residual energy storage, flyback converters are not operated above a duty ratio of 0.5.

Connect a regular scope probe to channel three of the oscilloscope. Clip this probe between CS1 and com to measure the input current. Observe the gate to source switching signal while adjusting potentiometer RV60 to produce a frequency of 70 kilohertz. Connect the DC power supply to input terminals V1+ and com. Observe the input current wave form and measure the mean input and output voltage. Record the frequency and duty ratio as well as the input current and voltage readings from the DC supply. Repeat this test after adjusting RV60 to a switching frequency of 50, 30, and 10 kilohertz with the duty cycle ratio fixed at 0.5. As the frequency decreases, the output ripple increases because the capacitor charge and discharge times also increase.

Flyback converters are typically used in isolated power supplies where the output must be galvanically isolated from the input. Preventing circuit damage in the event of failure and protecting users from hazardous voltages. Cell phone chargers convert the 120 volt AC main supply to an internal DC voltage that becomes the input to a flyback converter. The flyback converter in turn generates a five volt output to the standard USB connector that plugs into a cell phone and charges it. Galvanic isolation in the flyback converter protects both the cell phone and the user from contact with the 120 AC supply. In contrast, the cell phone likely uses a buck converter to reduce five volts from the charger to nominal 3.6 volts for its lithium-ion battery. For these safe low voltages, no isolation is necessary. The cathode ray tube in and older television or computer monitor uses an electron beam to illuminate phosphors on the screen. The horizontal deflection drive of CRT’s often incorporates flyback converters operating in the step up mode. The flyback converter generates the high voltage that controls this beam and moves it to strike chosen points on the screen.