Abnormal sensory function underlies visceral pain and other symptoms of functional and inflammatory bowel diseases. A protocol for the electrophysiological recording of the colonic afferent nerves in an ex vivo rat colorectum preparation is presented here.
Dysfunction of the colonic sensory nerves has been implicated in the pathophysiology of several common conditions, including functional and inflammatory bowel diseases and diabetes. Here, we describe a protocol for the in vitro characterization of the electrophysiological properties of colonic afferents in rats. The colorectum, with the intact pelvic ganglion (PG) attached, is removed from the rat; superfused with carbogenated Krebs solution in the recording chamber; and cannulated at the oral and anal ends to allow for distension. A fine nerve bundle emanating from the PG is identified, and the multiunit afferent nerve activity is recorded using a suction electrode. Distension of the colonic segment elicits gradual increases in multiunit discharge. A principal component analysis is conducted to differentiate the low-threshold, the high-threshold, and the wide-dynamic range afferent fibers. Chemical sensitivity of colonic afferents can be studied through the bath or intraluminal administration of test compounds. This protocol can be modified for application to other species, such as mice and guinea pigs, and to study the differences in the electrophysiological properties of thoracolumbar/hypogastric and lumbosacral/pelvic afferents of the descending colon in normal and pathological conditions.
The gastrointestinal tract (GIT) is richly innervated with extrinsic afferent nerves that convey sensory signals from the gut to the central nervous system and that contribute to the gut-brain interaction. Altered excitability of these extrinsic afferents, as well as altered central processing of the afferent inputs, underlies visceral pain and other symptoms of GI conditions, including functional and inflammatory bowel diseases1. Sensory information from the colorectum is conveyed primarily through the thoracolumbar/hypogastric and the lumbosacral/pelvic nerves (PN)2. There has been an increased interest in studying the electrophysiological properties of these primary afferent fibers in rodent disease models. However, in vivo electrophysiological recordings of the colonic afferents in rodents is a technical challenge and requires considerable surgical skills. In addition, hemodynamic changes, tissue movement, and anesthetics may also impact nerve activity and sensitivity to test stimuli in vivo. Therefore, in recent years, an increasing number of studies have employed in vitro (ex vivo) preparations of different species, including mice, rats, guinea pigs, and humans, to examine the mechanisms of sensory transduction in colonic afferents and the altered excitability in disease conditions.3,4,5,6,7,8
Two types of ex vivo colonic preparation have primarily been reported: the "flat-sheet" preparation5,9,10 and the "tube" preparation3,4. A video protocol for the "flat-sheet" murine colorectum preparation has been previously published11. In this protocol, the mouse colorectum, with the PN) or lumbar splanchnic nerves (LSN) attached, is harvested and superfused in a tissue chamber. The colorectum is cut open longitudinally, and the nerve bundle is extended into a recording compartment filled with paraffin oil. Nerve activity is recorded using a monopolar platinum-iridium electrode. The protocol allows for the identification of the receptive fields of individual afferent fibers by using unbiased electrical stimulation. It localizes the application of chemical stimuli, as well as the application of different mechanical stimulation paradigms (e.g., focal mucosal probing and circumferential stretch), to the afferent nerve endings. Because the nerve must be extended to a separate chamber from the tissue chamber, it is critical to keep the attached nerve relatively long; the successful dissection of the nerves poses a challenge to those new to this methodology. More recently, Nullens et al. published a video protocol for the in vitro recording of the mesenteric afferents in murine jejunal and colonic segments12. In this "tube" preparation, the gut segment with the mesentery attached is kept intact, thus allowing for graded distension and the intra- and extra-luminal administration of different chemicals. Since the mesentery nerve is recorded using a suction electrode, which can be positioned close to the tissue, afferent activity can be recorded even though the mesentery nerve is relatively short. However, the mesentery nerve consists of mixed populations of vagal and spinal afferent fibers that innervate the jejunum or thoracolumbar hypogastric. Lumbosacral pelvic afferents innervate the colorectum, which cannot be discriminated in this protocol. Here, we present a detailed protocol for the electrophysiological recording of rat colonic afferents using the "tube" colorectum preparation with an intact PG. This method may allow for the characterization of the functional properties of lumbar splanchnic (hypogastric) and lumbosacral pelvic afferents.
The experimental protocol reported here has been approved by the Animal Ethical Committee of Shanghai Jiaotong University School of Medicine (# SYXK2013-0050). The dissection of the colorectum with intact ganglion and nerve trunk takes a minimum of 15 minutes for a person quite experienced in this technique. It is therefore necessary to keep the animal alive but under deep anesthesia whilst performing the dissections, to ensure viability of the tissue for subsequent electrophysiological recording.
1. Preparation of Perfusion Solution and Test Compounds
2. Preparation of the Recording Electrode
3. Tissue Collection
4. Dissection of the Colonic Afferent Nerves
5. Preparation of the Suction Electrode
6. Electrophysiological Recording
7. Testing the Colonic Afferent Sensitivity
Figure 1 is the schematic illustration of the experimental setup for the ex vivo "tube" colorectum preparation, with a representative recording from a nerve distal to the PG. The nerve presumably contained a mixture of pelvic and lumbar splanchnic afferents. In preparations from normal rats, the colonic afferent nerves typically have a low level of irregular spontaneous activity. Ramp distension of the colon induces a gradual increase in the firing rate (Figure 1B). The mechanosensory property of each nerve is represented by plotting the intraluminal pressure-afferent nerve response curve (Figure 1C). Averaged pressure-response curves can be compared between groups (i.e., control versus treated) to reveal whether a treatment alters the mechanosensory property of the colonic afferent nerves (see Rong et al.13 for details on the pressure-afferent response curve).
Alternatively, recordings can be made from the PN or the LSN proximal to the PG. Figure 2 is a representative recording from a PN bundle that exhibited a mechanosensory response qualitatively similar to that of the bundle distal to the PG, shown in Figure 1B. Principal component analysis of the neural signal allows for the identification of single-unit activity. The discriminated single units are classified as low-threshold (LT) fibers, wide-dynamic range (WDR) fibers, and high-threshold (HT) fibers, according to the profiles of the responses to distension. LT units are activated at a low distension pressure, and the firing rate reaches a maximum at about 20 mmHg. WDR units are also activated at a low distension pressure, and the firing rate continues to increase as the intraluminal pressure increases (Figure 2A and C). HT units are activated at a distension pressure >20 mmHg (see Dong et al.)4.
The chemical sensitivity of the colonic afferents can be tested by superfusion (bath application) or intraluminal infusion. For example, the bath application of 10 µM 5-HT caused a modest increase, whereas capsaicin at 0.3 µM evoked robust increases in pelvic afferent discharge that were followed by a period of decreased activity due to desensitization (Figure 3).
Figure 1. Electrophysiological Recording of Rat Colonic Afferent Nerves In Vitro. A. A schematic illustration of the ex vivo "tube" colon preparation of the rat. The colorectum, with the attached PG, is superfused in the recording chamber and is cannulated at both ends. Intraluminal infusion is achieved using a syringe pump and moves in the oral to anal direction. Distension of the colon is effected by closing the three-way tap (d) on the outlet cannula. A fine nerve branch from the PG is cut and recorded using a suction electrode. A branch of the LSN and three branches of the PN joining the PG are also shown. a. The proximal cut end of a fine nerve projecting to the colon. b. The distal cut end of the nerve sucked into the electrode. c. The cut end of two fine nerves projecting to the urinary bladder. LSN: lumbar splanchnic nerves, PN: pelvic nerves. B. The representative traces of the colonic afferent nerve signal and intraluminal pressure. C. A plot of the pressure-response curve of this nerve. Please click here to view a larger version of this figure.
Figure 2. Representative Electrophysiological Recording from a Branch of the Pelvic Nerves during Ramp Distension of the Ex Vivo Colorectum. A. The response pattern of two single units (WDR and LT units), together with the multiunit mechanosensory response during ramp distension. B. A schematic illustration of the nerve bundle being recorded. LSN: lumbar splanchnic nerves, PN: pelvic nerves. C. Superimposed waveform of the two single units. Please click here to view a larger version of this figure.
Figure 3. Representative Electrophysiological Recording from a Branch of the Pelvic Nerves During the Bath Application of 5-HT and Capsaicin. (Left) Application of 10 µM 5-HT. (Right) Application of 0.3 µM capsaicin. Please click here to view a larger version of this figure.
The protocol presented here is a relatively straightforward experimental method to assess the electrophysiological properties of the colonic afferents of rats. The protocol (from tissue dissection to setting up the nerve recording) usually takes about 2 h to complete. Tissue collection (step 3) and preparation of the suction electrode (step 5) are the critical steps. It is crucial to be able to locate the PG, the LSN, and the PN and to take care not to damage the ganglion and nerves during tissue dissection. The tip of the glass pipette must be broken and beveled to a size compatible with the nerve bundle.
The preparation is usually viable for several hours, allowing for the study of the mechanosensitivity, the chemosensitivity, and the pharmacological profiles of the colorectal afferent nerves. Compared with the "flat-sheet" preparation11, in which mechanical stimulation is applied through mucosal stroking or circumferential stretching, this "tube" preparation allows for ramp or graded distension in a manner similar to the application of colorectal distension (CRD) in anesthetized or awake animals to assess visceral pain. Using a similar protocol, Wynn et al.3 studied the contribution of purinergic receptors to the mechanosensory transduction of rat colonic afferents and found that colonic afferents were activated by the bath application of ATP (P2X and P2Y agonist) and α,β-meATP (P2X agonist) and that distention-induced pelvic afferent discharge was attenuated by P2 receptor antagonists. More recently, we compared the mechanosensory responses of colonic afferents between normal and streptozotocin (STZ)-induced diabetic rats. We found a significant decrease in multiunit afferent nerve responses to ramp distension of the ex vivo colon in diabetic rats (3-6 weeks after STZ injection) compared to the control rats. The decreased mechanosensory response in colonic afferents observed in vitro was consistent with an attenuated visceromotor response (VMR) to in vivo CRD in the diabetic group. Single-unit analysis indicated that impaired mechanosensitivity of LT and WDR fibers may underlie the afferent hyposensitivity in the diabetic colon4. Using a similar protocol, we also successfully recorded from murine colonic afferents and detected significantly increased colonic afferent excitability in DSS-induced IBD mice (unpublished observations).
The colorectum is innervated by the thoracolumbar/hypogastric and the lumbosacral/pelvic afferent fibers1,2. It emerges that these two sets of primary afferents may differ significantly in their functional properties and may signal different qualities of colonic stimuli14,15,16,17. An important advantage of the current protocol is its potential to comparatively study the hypogastric and pelvic afferents of the colorectum. As illustrated in Figure 1, a lumbar splanchnic (hypogastric) nerve and 3 – 4 branches of the PN pass through the major PG and then project to the descending colon and the urinary bladder. We noted that the mechanosensory response of the PN bundle was qualitatively similar to that of the nerve distal to the PG, which presumably contained mixed lumbar splanchnic and pelvic afferents. Technically, it is highly feasible to place two suction electrodes near the PG to simultaneously record the LSN and the PN and to assess if they respond differently to mechanical and chemical stimulation.
The authors have nothing to disclose.
This protocol was supported by research grants from the National Natural Science Foundation of China (#31171066, #81270464) and the Sino-German Science Center (GZ919).
Sodium Pentobarbital | Shanghai Westang Bio-Tech | B558 | |
Capsaicin | Sigma | M2028 | |
Electrode puller | MicroData Instrument Inc | PMP107 | |
Neurolog System (Bioamplifier) | Digitimer, Ltd | Neurolog System | |
A/D converter | Cambridge Electronic Design | Micro1401 | |
Data processing software | Cambridge Electronic Design | Spike2 version 6 | |
Silver wire | World Precision Instruments | EP12 | |
Glass tubes | World Precision Instruments | 1B150-4 | |
Electrode holder | World Precision Instruments | MEH3SBW | |
Heating bath | Grant | GR150 | |
Dissecting microscope | Leica | Zoom2000 | |
Dissecting microscope | World Precision Instruments | PZMIII-BS | |
Cigarette lighter | any | NA | |
Surgical tools | World Precision Instruments | NA | |
Insect pins | home-made from 0.1 mm stainless steel wire | NA | |
Three way manipulator | World Precision Instruments | KITF-R | |
Rats | Any | NA | Any strain/sex can be used. |