The aim was to substantiate optimal use of data collection techniques for Nordic walking gait and posture analysis. Three-dimensional motion capture should be used during short duration analysis (i.e. single gait cycle), while accelerometry should be employed for longer duration analysis (i.e. repeated cycles) like a 6 Minute Walk Test.
Nordic walking (NW) has become a safe and simple form of exercise in recent years, and in studying this gait pattern, various data collection techniques have been employed, each with positives and negatives. The aim was to determine the effect of NW on older adult gait and posture and to determine optimal use of different data collection systems in both short and long duration analysis. Gait and posture during NW and normal walking were assessed in 17 healthy older adults (age: 69 ± 7.3). Participants performed two trials of 6 Minute Walk Tests (6MWT) (1 with poles (WP) and 1 without poles (NP)) and 6 trials of a 5m walk (3 WP and 3 NP). Motion was recorded using two systems, a 6-sensor accelerometry system and an 8-camera 3-dimensional motion capture system, in order to quantify spatial-temporal, kinematic, and kinetic parameters.
With both systems, participants demonstrated increased stride length and double support and decreased gait speed and cadence WP compared to NP (p <0.05). Also, with motion capture, larger single support time was found WP (p <0.05). With 3-D capture, smaller hip power generation and moments of force were found at heel contact and pre-swing as well as smaller knee power absorption at heel contact, pre-swing, and terminal swing WP compared to NP, when assessed over one cycle (p <0.05). Also, WP yielded smaller moments of force at heel contact and terminal swing along with larger moments at mid-stance of a gait cycle (p <0.05). No changes were found for posture.
NW seems appropriate for promoting a normal gait pattern in older adults. Three-dimensional motion capture should primarily be used during short duration gait analysis (i.e. single gait cycle), while accelerometry systems should be primarily employed in instances requiring longer duration analysis such as during the 6MWT.
Nordic walking (NW) is regarded as a simple and safe form of fitness walking using specially designed poles1. It is suggested that poles provide added stability, improve posture, and reduce joint stress of the lower extremities. However, limited or contradictory evidence exists regarding joint loading and postural alignment. On one hand, Schwameder et al.2, Willson et al.3, and Koizumi et al.4 report improvements in kinematic measures and/or reductions in ground reaction, compression, and shear forces with their pole walking studies. On the other hand, declining kinematic measures and increased joint loading in terms of braking/propulsive forces and moments of force have been reported by Hansen et al.5, Stief et al.6, and Hagen et al.7 while pole walking. Additionally, claims of improved postural alignment appear to have gone entirely unsupported by scientific research to this point.
Similar to the contradictory results found with gait patterns, different methods and equipment have been employed in this line of research as well. Several studies have used 3-dimensional motion capture systems4,6 and digital video cameras2,5, all with force plates incorporated into the system, in order to adequately assess gait. While additionally, other studies have employed other means of assessing Nordic poling gait including use of electrogoniometry7, electromyography (EMG)8, and strain gauges mounted to poles2,9. With the technique utilized in this protocol, it presents the specific advantage of being able to demonstrate a more appropriate representation (i.e. repeated gait cycles) of an individual's Nordic poling gait over alternative techniques that have focused more on short durations and single gait cycles. Also, this method uses accelerometry, a valid tool, which to this point has been sparsely used in Nordic walking research. Depending on the aim of individual research projects, the application of this protocol may be appropriate for situations as outlined in this protocol, particularly for short and long duration gait. It is important to note that both motion capture and accelerometry are suitable for obtaining a variety of gait characteristics including: spatial-temporal (e.g. stride length, gait speed, etc.), kinematic (e.g. range of motion), and kinetic (e.g. forces, power outputs, etc.) parameters.
And despite the use of these various pieces of equipment, only short duration gait events (i.e. single gait cycle) have been assessed, leaving questions in regards to best assessing longer duration gait (i.e. repeated gait cycles). Therefore, the rationale for the development and use of this technique is based upon the importance of fashioning a complete picture of Nordic poling gait.
The purpose of this study was two-fold. First, the primary goal is to determine and substantiate the use of both accelerometry systems and 3-dimensional motion capture systems in the assessment of gait and posture over both short and long durations. Secondarily, the goal is to determine the overall effect of Nordic walking poles on gait patterns including spatial-temporal and kinetic measures as well as postural alignment of older adults. To date, minimal research has focused on older adult NW and of that which has been published, function (i.e. strength, balance, flexibility) has represented the primary outcome variables. Therefore, knowledge pertaining the role of walking poles on measureable gait variables is needed and can provide insight into how poles can play into our gait patterns as we age.
This study was performed in accordance with the guidelines of the Research Ethics Board of the University of Ottawa.
1. Screening Procedure
2. Pole Set-up and Nordic Walking Instruction
3. Data Collection and Testing Protocol
4. Data and Statistical Analysis14
Spatial-Temporal Gait Parameters
When walking with Nordic walking poles and assessed using motion capture and force plates, stride length (p <0.01), double support time (p <0.001), and single support time (p <0.001) are all significantly longer compared to walking without poles. In addition, gait speed (p <0.05) is significantly slower and cadence (p <0.001) is significantly smaller with poles compared to without in older adults. Further, when examining gait over a longer duration walk with the 6MWT and using accelerometry, similar results are noted with a longer stride length (p <0.001) and double support time (p <0.001) as well as a significantly slower gait speed (p < 0.001) and smaller cadence (p <0.001) (Table 1).
Lower Extremity Joint Kinetic Analysis
Kinetic measures are solely assessed using 3-dimensional motion capture.
Hip Joint
When using poles, significantly smaller hip power generation is seen at heel contact (H1) (p <0.05) as well as at pre-swing (H3) (p <0.01) compared to walking without poles (Figure 1). To coincide with these reductions in hip power generation, the moment of force while walking with poles is significantly smaller at both heel contact (p <0.05) and pre-swing (p <0.05) compared to without poles.
Knee Power Generation/Absorption
When using poles, significantly smaller knee power absorption is seen at heel contact (K1) (p <0.05), at pre-swing (K3) (p <0.001), and at terminal swing (K4) (p <0.001) compared to walking without poles (Figure 2). Additionally, with poles significantly smaller moments of force are found at heel contact (p <0.001) and at terminal swing (p <0.001) and significantly larger moments of force at mid-stance (p <0.01) compared to without poles.
Ankle Power Generation/Absorption
There are no significant power output or moment of force differences at the ankle joint at either heel contact (A1) or toe-off (A2).
Postural Analysis
There are no significant differences in trunk range of motion when using accelerometry in any of the three planes of motion (i.e. frontal, sagittal, and horizontal) or with motion capture in the frontal and sagittal planes.
The results found in this research coincide with previous research on the same topic using similar motion capture systems. These results demonstrate that this technique and use of both motion capture and accelerometry can be widely appropriate in the assessment of gait and posture.
Figure 1: Peak hip power over a single gait cycle. This figure represents a typical hip power profile in watts per kilogram of body weight over one single gait cycle (i.e. heel strike of one foot to the next heel strike of that same foot) to compare with poles (Red) to without poles (Blue). The arrows at H1, H2, and H3 phases are indicative of the changes in power generation/absorption in comparing with poles to without poles, with the asterisks indicating a significant difference between the two. Please click here to view a larger version of this figure.
Figure 2: Peak knee power over a single gait cycle. This figure represents a typical knee power profile in watts per kilogram of body weight over one single gait cycle (i.e. heel strike of one foot to the next hell strike of that same foot) to compare with poles (Red) to without poles (Blue). The arrows at K1, K2, K3, and K4 phases are indicative of the changes in power generation/absorption in comparing with poles to without poles, with the asterisks indicating a significant difference between the two. Please click here to view a larger version of this figure.
VICON | APDM | |||
With Poles | Without Poles | With Poles | Without Poles | |
Outcome Measures | Mean ± SD | |||
Stride Length (m) | 1.39 ± 0.19 | 1.31 ± 0.21 † | 1.47 ± 0.11 | 1.42 ± 0.11 † |
Gait Speed (m/sec) | 1.08 ± 0.23 | 1.18 ± 0.20 * | 1.25 ± 0.17 | 1.39 ± 0.14 † |
Cadence (steps/min) | 93.07 ± 10.90 | 108.78 ± 11.26 † | 101.92 ± 12.17 | 117.82 ± 9.74 † |
Double Support Time (sec) | 0.34 ± 0.06 | 0.28 ± 0.06 † | 0.28 ± 0.07 | 0.22 ± 0.06 † |
Single Support Time (sec) | 0.48 ± 0.05 | 0.41 ± 0.04 † | — | — |
Table 1: Spatial-temporal means and standard deviation for both data collection systems. This table represents the various spatial-temporal measures obtained from both accelerometry and motion capture systems. Both crosses and asterisks represent a significant difference between with poles and without poles for each respective system, with crosses specifically representing significant difference at p <0.01 and asterisks representing a significant difference at p <0.05.
The importance of maintaining consistency in terms of pole use is critical within this protocol. Particularly, appropriate steps for proper poling technique as well as proper pole set up are important to maintain consistency across different studies. Therefore the guidelines and instructions of a specific Nordic walking organization should be adhered to for protocols such as this. Additionally and particularly when using accelerometry, use of a full body set of tri-axial monitors is important to obtain a complete understanding of the subject's full body motion (e.g. gait and posture) including acceleration and rotation of each specific body segment. Such a system can and should be primarily employed in instances as per this protocol, using a relatively long walkway (e.g. 25 m) in order to account for long duration events as well as minimize the number of turns to account for primarily steady state walking. This could be particularly important when using validated gait tests such as the 6MWT13 within both clinical and research settings.
Further, motion capture systems have been reported as appropriate equipment in studying short duration events such as single gait cycles16 and should be used as such, as is the case with the second portion of this protocol. To ensure accuracy of this system, it is imperative to perform proper static and dynamic calibrations of the system to set the capture volume and more importantly the global coordinate system required for 3-dimensional reconstruction of the reflective markers. In order to assess both gait as well as postural alignment, a full body marker set (e.g. Plug-in Gait model) is necessary as the positions and displacements of the hip (PSIS and Sacral) and spinal (C7) markers are critical in the analysis and measurement of trunk range of motion (ROM) in the anterior-posterior (AP) and medial-lateral (ML) directions. And lastly, the forces plates integrated with the system should be collecting at a sufficient sampling rate, for instance, 1,000 Hz from this protocol. Sampling rate can be changed from study to study, however, researchers must be certain not to violate the Sampling Theorem, which states "the process signal must be sampled at a frequency at least twice as high as the highest frequency present in the signal itself"17.
Depending on equipment availability within different laboratory setting, various accelerometry systems and motion capture systems may be used, provided they allow for adherence to the critical steps of this protocol. For example, if unable to use a tri-axial monitor system that has both acceleration and gyroscope readings or if the lab space is insufficient to incorporate a long walkway, use of this system may not be entirely adequate for the assessment of one's gait and posture. Similarly, with motion capture systems, use of a lower-body model for each participant is adequate in the assessment of various gait characteristics, however, lower-body models would fail to appropriately assess postural alignment as some of the necessary hip and spinal markers may be missing to calculate trunk ROM. Also, if using this protocol to examine specific conditions (e.g. knee osteoarthritis or ACL injury), use of different or modified marker sets such as that used by Ali, Rouhi, and Robertson18 may be used to create a more complete assessment of the knee for such conditions. Additionally, as this study is focused on older adults only, the protocol can benefit from the addition of a control group for comparison purposes, however, this is largely dependent on the populations for each individual study. Depending on the population, a control group (e.g. young adults) may contribute to further understanding how gait and postural alignment changes, both with and without the use of Nordic poles. Also, to better understand the role that the poles themselves play during gait, use of strain gauges could be incorporated. Following a technique previously used on healthy young adults by Jensen and colleagues9, placement of a strain gauge on each of the poles could assist in the assessment of kinetic gait measurements. And lastly, following a technique employed by Shim and colleagues8, using electromyography (EMG) with this protocol can aid in understanding the specific muscle activation patterns of both the upper and lower extremities during Nordic walking.
The originality of this protocol resides in the fact that it provides the guideline for state of the art gait analyses in two very different set-ups. Therefore, this gives rational and viable options for researchers and clinicians to choose from when deciding on the protocol that will serve best the purpose of their analysis. To reiterate, with the 3-dimensional motion capture system, the goal is to study short duration events as is the case with a single gait cycle, while accelerometer systems are used in this instance to study gait as a whole over a longer period of time. Different 3-dimensional motion capture systems as well as video cameras, all with force plates integrated into them have been commonly used in the assessment of Nordic walking gait3–6. Stief et al.6 used a 6-camera system to collect 5 poling and 5 non-poling trials in order to measure the kinematics (i.e. ROM) and kinetics (i.e. moments of force) about the hip, knee, and ankle joints. Similarly, a 10-camera system was used by Koizumi et al.4 with two force plates incorporated into it to obtain kinetic measurements from 10 Nordic walking trials in order to ultimately calculate shear and compression forces of the lower extremity joints and lumbar spine. Further, Hansen et al.5 used a 5-camera digital video system to record movements, again with two force platforms embedded in the walkway in order to quantify kinetic variables including: compression forces, shear forces, ground reaction forces, and moments of force. Existing methods fundamentally point to the use of motion capture systems as widely accepted and largely appropriate for an accurate and efficient measure of an individual's gait patterns, albeit for short duration events.
Contrary to the commonality of motion capture, alternative methods such as the one used by Hagen et al.7 have at times been employed. In this particular study, electrogoniometry and force plates are used to evaluate the spatial-temporal measures (e.g. stride length), lower extremity ROM, and kinetics, specifically the vertical force. They did also use an accelerometry system, however, it is a uniaxial monitor that was only placed on the right radial side of the wrist to measure wrist acceleration and assist in estimation of shock to the body. Beyond Hagen et al.7 in recent years, Nordic walking gait has really yet to be examined using accelerometry. And further yet, research has yet to study longer duration gait events such as with the 6MWT. Just as motion capture is widely used for short duration events, accelerometry should become more of a staple in gait analysis, particularly over a lengthier period of time. If use of accelerometry is more widely recognized and valued in this respect, this may allow for a more representative evaluation of gait as it is performed on a daily basis.
Once the protocol is perfected, using both accelerometry and motion capture for Nordic poling gait analysis will help to create an assessment of gait in its entirety that could be representative of both short spurts of walking as well as longer. Moreover, such techniques may be employed with specific populations (e.g. Parkinson's disease) to gain a better understanding of how Nordic walking poles can affect not only a single stride, but also obtain a better representation of their gait from repeated strides. Also, if available in clinical practice, clinicians may be able to use accelerometry to more precisely measure a patient's gait during clinical assessment. Such systems are particularly user friendly and simplify data collection and analysis. Finally, looking at the effect of a Nordic walking intervention may be appropriate to coincide with this protocol. It is possible that learning the poling technique and then instantly performing laboratory testing may not result in an entirely accurate assessment. Instead, practice with the poles for a period of time (e.g. 8 weeks) may provide a better assessment of the effect of Nordic poles on gait and posture.
The authors have nothing to disclose.
On behalf of my co-author and myself, I would like to acknowledge Nordixx Canada for helping to fund this research, our participants for their time and patience, and our fellow colleagues, Josée, Ria, Lei, and Nadia, for their help with various aspects of this study.
Nordic walking poles | Nordixx Canada | Nordixx Global Traveler or Walker | Alternative poles may be used |
APDM accelerometry system | APDM | Opal system | Alternative systems may be used |
Vicon motion capture system | Vicon | Alternative systems may be used | |
Kistler force platforms | Kistler | Alternative platforms may be used | |
Vicon Nexus & Polygon | Vicon | Used in data analysis | |
14mm reflective markers | Vicon | Number or markers depends on model | |
Tape measure | |||
Weight scale | |||
Caliper |