Özet

Imágenes de contraste en embriones de ratón Uso de alta frecuencia de ultrasonido

Published: March 04, 2015
doi:

Özet

A continuación, presentamos un protocolo para inyectar medios de contraste de microburbujas de ultrasonidos en la vida, aislados finales de la gestación de embriones murinos etapa. Este método permite el estudio de los parámetros de perfusión y de marcadores moleculares vasculares dentro del embrión utilizando imágenes de ultrasonido de alta frecuencia con contraste.

Abstract

Ultrasound contrast-enhanced imaging can convey essential quantitative information regarding tissue vascularity and perfusion and, in targeted applications, facilitate the detection and measure of vascular biomarkers at the molecular level. Within the mouse embryo, this noninvasive technique may be used to uncover basic mechanisms underlying vascular development in the early mouse circulatory system and in genetic models of cardiovascular disease. The mouse embryo also presents as an excellent model for studying the adhesion of microbubbles to angiogenic targets (including vascular endothelial growth factor receptor 2 (VEGFR2) or αvβ3) and for assessing the quantitative nature of molecular ultrasound. We therefore developed a method to introduce ultrasound contrast agents into the vasculature of living, isolated embryos. This allows freedom in terms of injection control and positioning, reproducibility of the imaging plane without obstruction and motion, and simplified image analysis and quantification. Late gestational stage (embryonic day (E)16.6 and E17.5) murine embryos were isolated from the uterus, gently exteriorized from the yolk sac and microbubble contrast agents were injected into veins accessible on the chorionic surface of the placental disc. Nonlinear contrast ultrasound imaging was then employed to collect a number of basic perfusion parameters (peak enhancement, wash-in rate and time to peak) and quantify targeted microbubble binding in an endoglin mouse model. We show the successful circulation of microbubbles within living embryos and the utility of this approach in characterizing embryonic vasculature and microbubble behavior.

Introduction

La ecografía con contraste hace uso de agentes de contraste de microburbujas de visualizar y caracterizar el ambiente vascular. Estos agentes permiten la evaluación no invasiva de la microcirculación, la vascularización y la función cardiovascular. Además, la modificación de la superficie de la burbuja puede resultar en microburbujas específica de unión a los biomarcadores endoteliales, como se ha demostrado en aplicaciones preclínicos de la angiogénesis, la aterosclerosis y la inflamación 1,2 toma de imágenes por ultrasonido molecular de eventos vasculares posibles. Por lo tanto, un mayor contraste de ultrasonido puede ser usado para identificar los entornos complejos y diversos que influyen en los estados vasculares sanas y enfermas 3-5.

En el último número de años, el interés en la utilidad de las imágenes de microburbujas se ha extendido al modelo de embrión de ratón versátil. Como modelo de desarrollo de los mamíferos, la introducción de microburbujas en la vasculatura embrionaria mejora fisiológicaestudio del desarrollo del sistema circulatorio (por ejemplo, el flujo sanguíneo, el gasto cardíaco) y en casos de transgénicos y dirigidos modelos de ratones mutantes de la enfermedad cardíaca 6,7, puede ayudar a comprender cómo los factores genéticos alterar la función cardiovascular. De hecho, los análisis 2D cuantitativa y cualitativa de la vasculatura del cerebro embrionario ya se han logrado 8. Además, el embrión de ratón se presenta como un modelo excelente para examinar la unión de microburbujas dirigidas a los marcadores vasculares in vivo. Bartelle et al. 9, por ejemplo, han introducido microburbujas avidina en embrión ventrículos cardíaco para evaluar dirigido específicamente vinculante en Biotag-Bira embriones transgénicos y examinar la anatomía vascular. La generación de modelos heterocigotos y homocigotos ratón también puede ser utilizado como un sustituto de los estudios de modelos tumorales con el objetivo de definir la naturaleza cuantitativa de ultrasonido molecular – un punto de referencia importante en la traducción de esta técnica a la clínica.

<p clculo = "jove_content"> microburbujas se presentó con mayor frecuencia a la circulación embrionaria a través de inyecciones intra-cardiaca en embriones únicos expuestos a través de una laparotomía 8-10. En inyecciones útero, sin embargo, se enfrentan a una serie de desafíos. Estos incluyen la orientación de la inyección, la necesidad de contrarrestar el movimiento en la madre y el embrión exteriorizada, el mantenimiento de la viabilidad de hemodinámica en la madre y embriones exteriorizados, abordando los efectos a largo plazo de la anestesia y las complicaciones por sangrado 11. Por lo tanto, el objetivo de la investigación fue desarrollar una técnica para la inyección de microburbujas en aislados de vida embriones en etapa tardía 12. Esta opción ofrece más libertad en términos de control de la inyección y el posicionamiento, la reproducibilidad del plano de formación de imágenes sin obstrucción, y análisis de imagen simplificada y cuantificación.

En el presente estudio, se describe un nuevo procedimiento para la inyección de microburbujas en que viven los embriones murinos FOr los efectos de estudiar el comportamiento cinético de microburbujas y de estudiar la unión a marcadores de superficie endoteliales endógenos de microburbujas dirigidas. Ecografía específica contraste no lineal se utiliza para medir una serie de parámetros de perfusión básicos, incluyendo la mejora de pico (PE), lavandería en la tasa y el tiempo hasta el pico (TTP) en aislados embriones E17.5. También demuestran la validez del modelo de embrión para evaluar la naturaleza cuantitativa de la ecografía molecular en una pérdida de la endoglina embrionario de modelo de ratón transgénico función, donde la endoglina es una diana clínicamente relevante debido a su alta expresión en las células endoteliales vasculares en los sitios de angiogénesis activa 13 . La adhesión de isotipo IgG de rata de control de la endoglina 2-dirigida (MB E), (MB C) y (U) MB microburbujas no focalizados se evalúa en la endoglina heterocigotos (Esp +/-) y homocigotos endoglina (Eng + / +) que expresan embriones. Análisis del bindi apuntadong revela que el ultrasonido molecular es capaz de diferenciar entre los genotipos endoglina y relacionando densidad de los receptores a los niveles cuantificables de ultrasonido moleculares.

Protocol

NOTA: Los procedimientos experimentales realizados en este estudio fueron aprobados por el Comité de Cuidado de Animales del Instituto de Investigación Sunnybrook (Toronto, Ontario, Canadá). Los procedimientos para el tratamiento humanitario de los animales deben ser observados en todo momento. Se supone que el investigador está entrenado en la operación básica de un sistema de imágenes de ultrasonido. Este protocolo funciona mejor con dos personas. 1. Modelos Animales Casa…

Representative Results

La inyección de agentes de contraste de ultrasonido en el útero los embriones de ratón ex depende del éxito en el aislamiento de la vida, embriones en fase tardía de la gestación del útero y el mantenimiento de la viabilidad en el transcurso de la inyección y de formación de imágenes de ultrasonido relacionada. Una vez que el embrión se ha exteriorizado y posicionado, como se muestra en la Figura 1, la inyección cuidadosa de agente de contraste en la vasculatura embrionaria…

Discussion

Los agentes de contraste de ultrasonido fueron inyectadas en la última etapa de la gestación de embriones de ratón y las imágenes de contraste no lineales fueron adquiridos para medir parámetros de perfusión y microburbujas dirigidos vinculante. El éxito de formación de imágenes de microburbujas dentro de la vasculatura embrionaria era dependiente de una serie de factores, siendo el primero la viabilidad del embrión. Todo el equipo y el aparato se prepararon de antemano con el fin de minimizar el tiempo requer…

Açıklamalar

The authors have nothing to disclose.

Acknowledgements

This work was supported by the Terry Fox Program of the National Cancer Institute of Canada.

Materials

Reagents Company Catalog Number Comments/Description
Antibodies (biotinylated, eBioscience) Antibody choice depends on the experiment
      rat isotype IgG2 control eBioscience 13-4321-85 This antibody/microbubble combination is often required as experimental control 
      biotin anti-mouse CD309 eBioscience 13-5821-85
Biotinylated rat MJ 7/18 antibody to mouse endoglin In house hybridoma Outside antibodies may also be appropriate: we  have used eBioscience (13-1051-85 ) in the past
Distilled water
Embryo media
     500 mL Dulbecco’s Modified Eagle’s Medium with high glucose Sigma D5796
     50 mL Fetal Bovine Serum ATCC 30-2020 lot # 7592456
     Hepes  Gibco 15630 5mL, 1M
     Penicillin-Streptomycin  Gibco 15140-122 5 mL, 10,000 units Pen., 10,000 ug Strep
Ethanol, 70%
Ice
Paraformaldehyde Sigma 76240 4%
Phosphate Buffered Saline [1x]  Sigma D8537 1x, w/o calcium chloride & magnesium chloride
Pregnant mouse, CD-1 Charles River Laboratories Inc. 
0.9% sodium chloride (saline) Hospira 0409-7984-11
Ultrasound contrast agent, target ready and untargeted MicroMarker; VisualSonics Inc.
Ultrasound gel (Aquasonic 100, colourless) CSP Medical 133-1009
Equipment
Cell culture plates (4) :  100×20 mm Fisher Scientific 08-772-22
Cell culture plates (12) : 60×15 mm Sigma D8054
Centrifuge Sorvall Legend RT centrifuge 
Conical tubes, 50 mL BD Falcon VWR 21008-938
Diluent Beckman Coulter Isoton II Diluent, 8448011
Dissection scissors (Wagner) Fine Science Tools Wagner 14068-12
Forceps (2), Dumont SS (0.10×0.06 mm) Fine Science Tools 11200-33
Forceps, splinter VWR 25601-134
Glass beaker, 2 L (Griffin Beaker) VWR 89000-216
Glass capillaries, 1×90 mm GD-1 with filament Narishige GD-1
Glass needle puller Narishige PN-30
Gloves Ansell 4002
Gross anatomy probe Fine Science Tools 10088-15
Hot plate VWR 89090-994
Ice bucket Cole Parmer RK 06274-01
Imaging Platform VisualSonics Inc. Integrated Rail System
Light source, fiber-optic Fisher Scientific 12-562-36 Ideally has adjustable arms
Luers (12), polypropylene barbed female ¼-28 UNF thread Cole Parmer 45500-30
Micro-ultrasound system, high-frequency VisualSonics Inc. Vevo2100
Needles, 21 gauge  (1”) VWR 305165
Particle size analyzer Beckman Coulter Multisizer 3 Coulter Counter
Perforated spoon (Moria) Fine Science Tools MC 17 10373-17
Pins (6), black anodized minutien 0.15 mm Fine Science Tools 26002-15
Pipettors [2-20 uL, 20-200uL, 100-1000uL] Eppendorf Research Plus  adjustable 3120000038;       3120000054;       3120000062
Pipettor tips [2-200uL, 50-1000uL] Eppendorf epT.I.P.S.                   22491334;             022491351
Scissors
Sylgard 184 Silicone Elastomer Kit Dow Corning
Tubing, Tygon laboratory 1/32×3/32” VWR 63010-007
Wooden applicator stick (swab, cotton head) VWR CA89031-270
Surgical microscope 5-8x magnification Fisher Scientific Steromaster
Syringes, 1 mL Normject Fisher 14-817-25
Syringes (10), 30 mL VWR CA64000-041
Syringe infusion pump  Bio-lynx  NE-1000
Thermometer, -20-110oC VWR 89095-598
Timer VWR 33501-418
Tubes, Eppendorf VWR 20170-577
Tube racks (3) VWR 82024-462
Ultrasound transducer, 20 MHz VisualSonics Inc. MS250
Vannas-Tubingen, angled up Fine Science Tools 15005-08

Referanslar

  1. Voigt, J. U. Ultrasound molecular imaging. Methods. 48 (2), 92-97 (2009).
  2. Klibanov, A. Preparation of targeted microbubbles: Ultrasound contrast agents for molecular imaging. Medical Biological Engineering Computing. 47 (8), 875-882 (2009).
  3. Cosgrove, D., Lassau, N. Imaging of perfusion using ultrasound. European Journal Of Nuclear Medicine And Molecular Imaging. 37 (S1), 65 (2010).
  4. Williams, R., et al. Dynamic microbubble contrast-enhanced US to measure tumor response to targeted therapy: A proposed clinical protocol with results from renal cell carcinoma patients receiving antiangiogenic therapy. Radiology. 260 (2), 581 (2011).
  5. Burns, P. N., Wilson, S. R. Focal liver masses: Enhancement patterns on contrast-enhanced Images – Concordance of US scans with CT scans and MR images. Radiology. 242 (1), 162 (2006).
  6. Phoon, C. K. L., Aristizabal, O., Turnbull, D. H. 40 MHz doppler characterization of umbilical and dorsal aortic Blood flow in the early mouse embryo. Ultrasound. In Medicine And Biology. 26 (8), 1275-1283 (2000).
  7. Phoon, C. K. L., Aristizabal, O., Turnbull, D. H. Spatial velocity profile in mouse embryonic aorta and doppler-derived volumetric flow: A preliminary model. Am J Physiol Heart Circ Physiol. 283, H908-H916 (2002).
  8. Aristizábal, O., Williamson, R., Turnbull, D. H. . 12A-4 in vivo 3D contrast-enhanced imaging of the embryonic mouse vasculature. Paper presented at Ultrasonics Symposium. , (2007).
  9. Bartelle, B. B., et al. Novel genetic approach for in vivo vascular imaging in mice. Circ.Res. 110 (7), 938-947 (2012).
  10. Endoh, M., et al. Fetal gene transfer by intrauterine injection with microbubble-enhanced ultrasound. Molecular Therapy. 5 (5), 501-508 (2002).
  11. Yamada, M., Hatta, T., Otani, H. Mouse exo utero development system: Protocol and troubleshooting. Congenital Anomalies. 48 (4), 183-187 (2008).
  12. Denbeigh, J. M., Nixon, B. A., Hudson, J. M., Purin, M. C., Foster, F. S. VEGFR2-targeted molecular imaging in the mouse embryo: An alternative to the tumor model. Ultrasound in medicine and biology. 40 (2), 389-399 (2014).
  13. Paauwe, M., Dijke, t. e. n., P, L. J. A. C., Hawinkels, Endoglin for tumor imaging and targeted cancer therapy. Expert Opinion On Therapeutic Targets. 17 (4), 421-435 (2013).
  14. Bourdeau, A., Faughnan, M. E., Letarte, M. Endoglin-deficient mice, a unique model to study hereditary hemorrhagic telangiectasia. Trends Cardiovasc. Med. 10 (7), 279-285 (2000).
  15. Whiteley, K. J., Adamson, S. L., Pfarrer, C. D. Vascular corrosion casting of the uteroplacental and fetoplacental vasculature in mice. Placenta And Trophoblast: Methods And Protocols. 121 (121), 371-392 (2006).
  16. Kulandavelu, S., et al. Embryonic and neonatal phenotyping of genetically engineered mice. ILAR Journal. 47 (2), 103-10 (2006).
  17. Kalaskar, V. K., Lauderdale, J. D. Mouse embryonic development in a serum-free whole embryo culture system. Journal of Visualized Experiments. 85, (2014).
  18. Willmann, J. K., et al. Targeted contrast-enhanced ultrasound imaging of tumor angiogenesis with contrast microbubbles conjugated to integrin-binding knottin peptides. The Journal of Nuclear Medicine. 51 (3), 433-440 (2010).
  19. Deshpande, N., Ren, Y., Foygel, K., Rosenberg, J., Willmann, J. K. Tumor angiogenic marker expression levels during tumor growth: Longitudinal assessment with molecularly targeted microbubbles and US imaging. Radiology. 258 (3), 804-811 (2011).
  20. Lyshchik, A., et al. Molecular imaging of vascular endothelial growth factor receptor 2 expression using targeted contrast-enhanced high-frequency ultrasonography. Journal Of Ultrasound In Medicine. 26 (11), 1575-1586 (2007).
  21. Jerkic, M., et al. Endoglin regulates nitric oxide-dependent vasodilatation. The FASEB Journal. 18 (3), 609-611 (2004).
  22. Denbeigh, J. M., Nixon, B. A., Lee, J. J. Y., et al. . Contrast-Enhanced Molecular Ultrasound Differentiates Endoglin Genotypes in Mouse Embryos. , (2014).
  23. Adamson, S. L., Lu, Y., Whiteley, K. J., et al. Interactions between trophoblast cells and the maternal and fetal circulation in the mouse placenta. Dev Biol. 250, 358-35 (2002).
  24. Needles, A., et al. Nonlinear contrast imaging with an array-based micro-ultrasound system. Ultrasound. Medicine Biology. 36 (12), 2097 (2010).
  25. Watson, E. D., Cross, J. C. Development of structures and transport functions in the mouse placenta. Physiology. 20 (3), 180-193 (2005).
  26. Shalaby, F., Rossant, J., Yamaguchi, T. P., et al. Failure of blood-island formation and vasculogenesis in Flk-1-deficient mice. Nature. 376, 62-66 (1995).
  27. Kwee, L., Baldwin, H. S., Shen, H. M., et al. Defective development of the embryonic and extraembryonic circulatory systems in vascular cell adhesion molecule (VCAM-1) deficient mice. Development. 121, (1995).
  28. Mercurio, A. M. Lessons from the α2 integrin knockout mouse. The American journal of pathology. , 161-163 (2002).
  29. Hodivala-Dilke, K. αvβ3 integrin and angiogenesis: a moody integrin in a changing environment. Curr Opin Cell Biol. 20, 514-519 (2008).
  30. Pysz, M. A., Gambhir, S. S., Willmann, J. K. Molecular imaging: current status and emerging strategies. Clinical radiology. 65, 500-516 (2010).
  31. Cybulsky, M. I., Iiyama, K., Li, H., et al. A major role for VCAM-1, but not ICAM-1, in early atherosclerosis. J Clin Invest. 107, 1255-1262 (2001).
  32. Xu, H., Gonzalo, J. A., St Pierre, ., Y, , et al. Leukocytosis and resistance to septic shock in intercellular adhesion molecule 1-deficient mice. J Exp Med. 180, 95-109 (1994).
  33. Gerwin, N., Gonzalo, J. A., Lloyd, C., et al. Prolonged eosinophil accumulation in allergic lung interstitium of ICAM-2-deficient mice results in extended hyperresponsiveness. Immunity. 10, 9-19 (1999).
  34. Johnson, R. C., Mayadas, T. N., Frenette, P. S., et al. Blood cell dynamics in P-selectin-deficient mice. Blood. 86, 1106-1114 (1995).
  35. Corrigan, N., Brazil, D., McAuliffe, F. High-frequency ultrasound assessment of the murine heart from embryo through to juvenile. Reproductive Sciences. 17 (2), 147-14 (2010).
  36. Turnbull, D. H., Bloomfield, T. S., Baldwin, H. S., Foster, F. S., Joyner, A. L. Ultrasound backscatter microscope analysis of early mouse embryonic brain development. Proc Natl Acad Sci U S A. 92, 2239-2243 (1995).
  37. Greco, A., Mancini, M. L., Gargiulo, S., et al. Ultrasound Biomicroscopy in Small Animal Research: Applications in Molecular and Preclinical Imaging. Journal of Biomedicine and Biotechnology. 2012, (2012).
  38. Pysz, M. A., Guracar, I., Foygel, K., Tian, L., Willmann, J. K. Quantitative assessment of tumor angiogenesis using real-time motion-compensated contrast-enhanced ultrasound imaging. Angiogenesis. 15, 433-442 (2012).
  39. Larina, I. V., et al. Live imaging of blood flow in mammalian embryos using doppler swept-source optical coherence tomography. J.Biomed.Opt. 13 (6), 060506-06 (2008).
  40. Garcia, M. D., Udan, R. S., Hadjantonakis, A. K., Dickinson, M. E. . Live imaging of mouse embryos. 4 (4), 104-10 (2011).
  41. Teichert, A., et al. Endothelial nitric oxide synthase gene expression during murine embryogenesis. Commencement of expression in the embryo occurs with the establishment of a unidirectional circulatory system. Circulation Research. 103 (1), 24-33 (2008).
  42. Walls, J. R., Coultas, L., Rossant, J., Henkelman, R. M. Three-dimensional analysis of vascular development in the mouse embryo. PLoS One. 3 (8), (2008).

Play Video

Bu Makaleden Alıntı Yapın
Denbeigh, J. M., Nixon, B. A., Puri, M. C., Foster, F. S. Contrast Imaging in Mouse Embryos Using High-frequency Ultrasound. J. Vis. Exp. (97), e52520, doi:10.3791/52520 (2015).

View Video