We describe a simple and low cost technique for introducing high concentration of fluorescent and calcium-sensitive dyes into neurons or any neuronal tract using a polyethylene suction pipette.
Retrograde labeling of neurons is a standard anatomical method1,2 that has also been used to load calcium and voltage-sensitive dyes into neurons3-6. Generally, the dyes are applied as solid crystals or by local pressure injection using glass pipettes. However, this can result in dilution of the dye and reduced labeling intensity, particularly when several hours are required for dye diffusion. Here we demonstrate a simple and low-cost technique for introducing fluorescent and ion-sensitive dyes into neurons using a polyethylene suction pipette filled with the dye solution. This method offers a reliable way for maintaining a high concentration of the dye in contact with axons throughout the loading procedure.
Fluorescent dextrans have been used as anatomical tools and for imaging neuronal activity1-4. Fields et al., (2009)4 published a protocol for applying ion- and voltage-sensitive dyes to axonal tracts with a focus on the spinal cord as a model system. Here we describe a more detailed procedure for applying fluorescent and/or ion-sensitive dye to the cut ventral roots, dorsal roots or any neuronal tract of the spinal cord for in-vitro optophysiological and morphological studies.
1. Type-I and Type-II Pipettes
Start by pulling two short sections of polyethylene tubing (PE90, Clay Adams Brand) over the flame of an alcohol lamp7 to produce pipettes with tapered tips. One pipette (Type-I) should be short (3-7 mm) with a small tip that can tightly hold the target root or tract (Outer Diameter: 0.2-0.4 mm; Inner Diameter: 0.1-0.3 mm). Then pull a second pipette (Type-II) with a longer (8-12 cm) thinner, shaft and a very fine tip (Outer Diameter: 0.2-0.3 mm; inner Diameter: 0.1-0.2 mm) that can be inserted into the Type-I pipette as far as its tip. The second thinner pipette will be used to aspirate and introduce artificial cerebrospinal fluid (aCSF) and dye solution respectively from the Type-I pipette.
2. Positioning of Type-I Pipette
Dissect and isolate the spinal cord8,9 and place it in a bath, superfused with chilled aCSF (~16 °C) throughout the loading process. Place the Type-I pipette on an electrode holder (H1/12 electrode holder, Narishige) so that its back opening can be easily connected to a syringe (1ml U-100 Insulin syringe, Becton Dickenson or comparable) via a flexible tubing (PharMed BPT, Cole-Parmer, #AY242002; 10 cm) (Fig.1A-B).
3. Dye Application
4. Incubation
Incubate the tissue in the dark between 6 to 20 hours depending on the type of experiment. Once sufficient time has been allowed for filling, gently pull away the electrode from the tissue leaving the tissue ready for imaging or histology.
Troubleshooting
5. Representative Results
To illustrate an application of the method, we simultaneously loaded motoneurons, sensory afferents and spinal interneurons with three different dextran-conjugated fluorescent dyes (Fig. 3A). As illustrated in Fig. 3B, three classes of neuron are labeled; sensory afferents (red), interneurons projecting into the ventral funiculus (green) and motoneurons (blue).
Figure 1. Schematic showing Pipette Type-I and Type-II assembly. (A) A Type-I pipette (light blue) is placed on an electrode holder so that it’s back opening can be easily connected to the flexible elastomer tubing (B) and into which a Type-II pipette can be inserted (C).
Figure 2. Schematic showing the loading process of motoneurons with fluorescent dyes. (A) A Type-I pipette is placed near the ventral root to be filled. (B) Suction is applied to the pipette to draw aCSF into the pipette followed by the root. (C-D) Disconnect the flexible elastomer tubing from the backend of Type-I pipette and reduce the amount of aCSF by applying suction to the Type-II pipette. (E) Insert the tip of the Type-II pipette containing the dissolved dye into the remaining aCSF in the Type-I pipette. (E-F) Slowly fill the Type-I pipette with the dye and then remove the Type-II pipette.
Figure 3. Application of the filling procedure to the isolated mouse spinal cord. (A) Schematic showing the three Type-I pipettes used to fill different neuronal classes in the spinal cord. Motoneurons (blue; Cascade Blue dextran) and sacral sensory afferents (red; Texas-Red dextran) were backfilled through the ventral and dorsal roots, respectively. Fluorescein dextran was used to load spinal interneurons (green) whose axons ascend through the ventral funiculus (VF). 1 mg of each dextran dye (10,000MW; Molecular Probes) was dissolved in 6 μL distilled water containing 0.2% Triton X-100 (B). Confocal image of a section from the sacral cord of a spinal cord in which the neurons were back-labeled as described in A. Note that the labeled sensory afferents are primarily ipsilateral with a few contralateral projections. The labeled motoneurons are ipsilateral to the filled ventral root whereas the labeled interneurons are contralateral to the side of the fill (arrow head). Calibration bar 200 μm.
We describe here a simple and cost-effective protocol for introducing dyes into neurons, nerves and spinal tracts. This method involves exposing identified anatomical pathways to a highly concentrated dye solution for the duration of the loading process. This results in retrograde labeling of the target site with little background compared to microinjections, bath application and electroporation techniques. However, the method is limited to sites in the nervous system where a tract of axons can be isolated. Furthermore, because the dye appears to diffuse along the axons to reach the cell bodies, the loading time will depend on the distance from the site of dye application to the neuronal somata. At least under in vitro conditions, this restricts the method to axonal tracts a few mm in length.
Applications for this type of dye-loading include retrograde labeling of motoneurons and anterograde labeling of sensory afferents in normal and mutant mice10,11. In addition, it has been used to show that sensory afferents make direct contacts onto spinal relay interneurons that project to lumbar segments12, to define the activation patterns of motoneurons in neonatal mice13, and to record the responses of spinal motoneurons14 and interneurons15 to descending inputs.
The authors have nothing to disclose.
This work was supported by the intramural program of the National Institutes of Neurological Disorders and Stroke at the National Institutes of Health. We would also like to thank Dr. George Mentis for his earlier contributions to the method and to the data in Figure 3.
Material Name | Company | Catalogue number | Yorumlar | |
Tubing | PE90 (IDxOD:0.034″x0.050″; Wall Thikness:0.008″) | Clay Adams Brand Intermedic | 427421 | For Type I & Type II pipettes |
NSF-51(IDxOD:1/16×1/8; Wall Thikness:1/32) | PharMed BPT, Cole-Parmer | AY242002 | For Flexible tubing | |
Syringe | 1ml insulin Syringe U-100 | Becton Dickenson | 329650 | |
Needle | 19G x1-1/2″ Metal Hub Needle | MONOJECT | 200136 | Connecting Type II pipette to syringe |
Alcohol Lamp | ||||
Stopcock | Three-way Stopcock with Male Luer Slip Adapter | Baxter Healthcare Corp. | 2C6241 | Use with syringe |
Holder | H-1 electrode holder | Narishige | H-1/12 | |
Magnet stand | Narishige | GJ-8 | ||
Micromanipulator | Narishige | M-3333 | ||
Tweezers | S&T DUMONT Swiss 00632-11 | DUMONT | JF-5 TC |
*Those are suggested materials. Can be replaced with any compatible products