An easy and convenient method to determine the extent of gap junction tracer coupling between retinal neurons is described. This technique enables one to investigate the function of the electrical synapses between neurons in the intact retina under different illumination conditions and at different times of the day and night.
In addition to chemical synaptic transmission, neurons that are connected by gap junctions can also communicate rapidly via electrical synaptic transmission. Increasing evidence indicates that gap junctions not only permit electrical current flow and synchronous activity between interconnected or coupled cells, but that the strength or effectiveness of electrical communication between coupled cells can be modulated to a great extent1,2. In addition, the large internal diameter (~1.2 nm) of many gap junction channels permits not only electric current flow, but also the diffusion of intracellular signaling molecules and small metabolites between interconnected cells, so that gap junctions may also mediate metabolic and chemical communication. The strength of gap junctional communication between neurons and its modulation by neurotransmitters and other factors can be studied by simultaneously electrically recording from coupled cells and by determining the extent of diffusion of tracer molecules, which are gap junction permeable, but not membrane permeable, following iontophoretic injection into single cells. However, these procedures can be extremely difficult to perform on neurons with small somata in intact neural tissue.
Numerous studies on electrical synapses and the modulation of electrical communication have been conducted in the vertebrate retina, since each of the five retinal neuron types is electrically connected by gap junctions3,4. Increasing evidence has shown that the circadian (24-hour) clock in the retina and changes in light stimulation regulate gap junction coupling3-8. For example, recent work has demonstrated that the retinal circadian clock decreases gap junction coupling between rod and cone photoreceptor cells during the day by increasing dopamine D2 receptor activation, and dramatically increases rod-cone coupling at night by reducing D2 receptor activation7,8. However, not only are these studies extremely difficult to perform on neurons with small somata in intact neural retinal tissue, but it can be difficult to adequately control the illumination conditions during the electrophysiological study of single retinal neurons to avoid light-induced changes in gap junction conductance.
Here, we present a straightforward method of determining the extent of gap junction tracer coupling between retinal neurons under different illumination conditions and at different times of the day and night. This cut-loading technique is a modification of scrape loading9-12, which is based on dye loading and diffusion through open gap junction channels. Scrape loading works well in cultured cells, but not in thick slices such as intact retinas. The cut-loading technique has been used to study photoreceptor coupling in intact fish and mammalian retinas7, 8,13, and can be used to study coupling between other retinal neurons, as described here.
1. Intact neural retina preparations for goldfish, mice and rabbits
2. Cut-loading
3. Quantification of tracer coupling using ImageJ
4. Representative Results
Representative examples of photoreceptor cell tracer coupling as determined by cut-loading are presented in Figures 2 and 3 (fish) and Figure 4 (rabbit). Confocal images were taken using the same settings for comparison (Fig. 2A-C and Fig. 4A-C) and the fluorescence intensity was plotted as a function of the distance from the cut and fitted by the exponential function shown in No. 3.8 above (Fig. 2D and Fig. 4D). Space constant values for each condition are shown in Figures 2E and 4E, illustrating that the extent of gap junction tracer coupling can be quantified using the cut-loading technique. In addition, the results are highly reproducible. Use of the cut-loading technique as a means of quantifying the extent of gap junction tracer coupling is also validated by the finding that fluorescence intensity decreases exponentially as a function of distance from the cut in all cases examined7,8 (see also Figs. 2D and 4D here), indicating that neurobiotin entered the photoreceptors via the razor cut and not from other retinal sites. Moreover, the qualitatively similar day/night difference in photoreceptor cell tracer coupling observed in goldfish with tracer injections into single cones and with cut-loading7 substantiates cut-loading as a relatively accurate means of measuring the extent of photoreceptor coupling.
The cut-loading technique can also be used to investigate other types of electrical synapses in the retina. For example, Figure 5 illustrates that rabbit A-type (Fig. 5A) and B-type (Fig. 5B) horizontal cells exhibit homologous tracer coupling following cut-loading and diffusion of neurobiotin under dark-adapted conditions.
Compound | Fish | Mouse | Rabbit |
NaCl | 130 | 120 | 117 |
NaHCO3 | 20 | 25 | 30 |
NaH2PO4 | – | 1 | 0.5 |
KCL | 2.5 | 5 | 3.1 |
Glucose | 10 | 10 | 10 |
MgCl2 | 1 | – | – |
MgSO4-7H2O | – | 1 | 1.2 |
Glutamine | – | 0.1 | 0.1 |
CaCl2 | 0.7 | 2 | 2 |
Table 1: Composition of the Ringer’s solutions for goldfish, mouse and rabbit retinas. The concentrations are presented in mM. The Ringer’s solutions are bubbled with 5% CO2 /95% O2 and maintained at 22 °C (fish) or 36 °C (mammals). “-” : not included in the Ringer for this species.
Figure 1.: Flow chart showing the cut-loading procedure. After isolation of the intact neural retina, several radial cuts were made by a blade that was first dipped in 0.5% neurobiotin solution. The retina was incubated for tracer loading and diffusion, and then washed before fixation with 4% paraformaldehyde (PFA) in 0.1M phosphate buffer (PB). Tracer coupling was examined using streptavidin-conjugated Alexa-488.
Figure 2. Day-night difference in photoreceptor tracer coupling in goldfish is revealed by the cut-loading technique. Photoreceptor cell gap junction neurobiotin tracer coupling was extensive at night (B) and in the day following application of spiperone (10 μM), a selective dopamine D2 receptor antagonist (C), but not in the day under control conditions (A). D) Normalized relative fluorescent intensity as a function of the distance from the cuts (indicated by arrows in A-C). E) Space constant values obtained from the data in D and other experiments (n = 4). ***P < 0.001.
Figure 3. A representative example showing fluorescence in the photoreceptor cell layer of a dark-adapted goldfish retina at night following cut-loading with a solution of both neurobiotin and rhodamine dextran. Rhodamine dextran (shown in red), which does not diffuse through open gap junction channels due to its high molecular weight (> 10,000 MW), only labeled cells near the cut. In contrast, neurobiotin (shown in green) diffused through gap junctions and can be seen in photoreceptor cells far from the cut. The location of the cut is indicated by the arrow in each panel. Scale bar: 200 μm.
Figure 4. Day-night difference in photoreceptor tracer coupling in rabbit retina is revealed by the cut-loading technique. Photoreceptor cell gap junction neurobiotin tracer coupling was extensive at night (B) and in the day following application of spiperone (10 μM) (C), but not in the day under control conditions (A). In A-C, perpendicular views of the 3D reconstruction of rabbit photoreceptors near the cut are shown. D) Normalized relative fluorescent intensity as a function of the distance from the cuts. E) Space constant values obtained from the data in D and other experiments (n = 3). ***P < 0.001.
Figure 5. Cut-loading reveals that dark-adapted rabbit horizontal cells are tracer coupled. Both A-type (A) and B-type (B) horizontal cells in dark-adapted rabbit retinas exhibited homologous neurobiotin tracer coupling.
The cut-loading method described here is a useful and straightforward technique to determine the extent of gap junction tracer coupling between retinal neurons under different illumination conditions and at different times of the day and night. Advantages of this technique include the ability to quantify the extent of gap junction tracer coupling between neurons in intact retinal tissue under a variety of illumination conditions during the day and night and to do so for coupled neurons that have small diameter somata. Limitations of the technique in the study of gap junctions in intact tissue fall into two general categories. First, tracer diffusion through open gap junctions may be relatively difficult to observe due to a) the small diameter of or the charge associated with the open channels and b) the relative volumes of coupled cellular compartments1,14,15. That is, tracer diffusion from a small cell to a larger cell or group of coupled cells, compared to tracer diffusion from a larger cell to a smaller cell, may be more difficult to detect due to tracer dilution. Second, under some physiological conditions, the extent of tracer diffusion through gap junctions in intact tissue may not accurately reflect the strength of gap junctional conductance due to differences in the conductance of small electric current-carrying ions, compared to the permeability of relatively large tracer molecules1,14,15. In general, evidence of tracer coupling strongly suggests the presence of functioning, open gap junction channels, but under some physiological conditions, tracer diffusion may not occur or be observed even though electrophysiological recordings suggest the presence of functioning, open gap junctions.
It seems likely that the cut-loading technique can also be used to investigate the extent of gap junction tracer coupling between neurons in intact tissue from other regions of the central nervous system.
The authors have nothing to disclose.
This work was funded by NIH grant EY005102 to S.C.M. and EY018640 to C.P.R.
Name of the reagent | Company | Catalogue number | Comments (optional) |
Tricaine methane sulfonate (MS222) | Sigma-Aldrich | A5040 | 150 mg/L of buffered fish tank water |
Urethane | Sigma-Aldrich | U2500 | 2 g/kgloading dose |
Dual Tube Night Vision Goggle | Night Optics USA | D-221 | |
Filter Paper, Grade No. 4 | Whatman | 1004-090 | |
Fine Forceps, Dumont No. 5, Biologie, 11 cm long | Fine Science Tools | 11295-10 | |
Fine Scissors, spring-loaded, 8 mm blade, straight | Fine Science Tools | 15025-10 | |
Neurobiotin | Vector | SP-1120 | 0.5% |
Streptavidin-conjugated Alexa 488 | Invitrogen | S11223 | 2% |
Dextran rhodamine(high (> 10,000) MW) | Invitrogen | D1817 | 0.5% |
Vectashield mounting medium | Vector | H-1000 | |
Zeiss 510 META Laser Scanning Confocal Microscope | Carl Zeiss, Inc. | ||
LSM-5 Image Browser 3,2,0,115 | Carl Zeiss, Inc. | ||
ImageJ Software | NIH | ||
OriginPro 8.0 | OriginLab Corp. |