Source: Marger, L. et al., Calvarial Model of Bone Augmentation in Rabbit for Assessment of Bone Growth and Neovascularization in Bone Substitution Materials. J. Vis. Exp. (2019).
In this video, we describe the surgical procedure to generate a rabbit calvarial model to evaluate the bone regeneration capacities of bone sample substitution materials of interest.
All procedures involving animal models have been reviewed by the local institutional animal care committee and the JoVE veterinary review board.
1. Surgery
2. Post-surgical treatment
Figure 1: Specifications of PEEK cylinders. Two holes (0.8 mm in diameter) were drilled on the lateral stabilizing tabs for screwing. The positions of the 5 intramedullary holes (0.8 mm in diameter) to be drilled on the skull within the area delimited by the cylinder are marked using red circles.
Figure 2: Representative image of the rabbit skull and placement of the cylinders. Pictures showing the median and coronal sutures on the rabbit skull delineating the left-right parietal and frontal bones (A,B). Placement of the cylinders on both side of the sutures (C). Scale bars = 5 mm.
Figure 3: Representative image of cylinders fixed, filled and caped. Picture showing four cylinders fixed onto the skull of a rabbit with titanium screws. Within the area delimited by each cylinder, 5 intramedullary holes (0.8 mm in diameter, ~1 mm in depth) were drilled under irrigation with a round bur to allow bone cell migration. Cylinders were filled with different bone substitute samples (calibrated volumes) before capping (one closed cylinder is shown only). Scale bar = 5 mm.
The authors have nothing to disclose.
Drugs | |||
Fentanyl | Bischel | For analgesia | |
Ketalar 50mg/ml | Pfizer | Ketamine for anesthesia | |
Lidohex | Bichsel | Lubricating gel for the eyes | |
Opsite | Smith and Nephew | 66004978 | Sprayable dressing |
Povidone iodine 10%, Betadine | Mundipharma | anti-infective agent | |
Propofol 2% | Braun | 3538710 | For anesthesia |
Rapidocain 2% | sintetica | Local anesthesia | |
Rompun 2% | Bayer | Xylazin for anesthesia | |
Sevoflurane 5% | Abbvie | For anesthesia | |
Equipment | |||
Fresenius Vial pilot C | Imexmed | Infusion pump | |
Heated pad | Harvard Apparatus | ||
Suction dominant 50 | Medela | ||
Suction tubing Optimus | Promedical | 80342.2 | |
Surgical motor | Schick dental | Qube | Drilling of intramedullary holes |
Ventilation | Maquet Servo1 | ||
Material | |||
Cylinders and caps | Boutyplast | Customized | composition: PEEK (poly ether ether ketone) |
Manual self-retaining shaft | GlobalD | ACT1K | |
Mobile handle for self-retaining shaft | GlobalD | MTM | |
Self- drilling screws | GlobalD | VA1.2KL4 | cross-drive screws composed by Titanium grade5, ISO 5832-3 |
Surgical tray | |||
Endotracheal tube Shiley diameter 2,5mm | Covidien | 86233 | For intubation |
Endotracheal tube Shiley diameter 4,9mm | Covidien | 107-35G | For intubation |
Ethicon prolene 4-0 | Ehticon | 8581H | Non-resorbable suture |
Forceps | Marcel Blanc | BD027R | 145 mm |
Intubation catheter | Cook medical | Guide for intubation | |
Round surgical burs | Patterson | 78000 | 0.8 mm in diameter, Drilling of intramedullary holes |
Scalpel | Swann-Morton | n°10 and n°15 | |
Scissors | Marcel Blanc | 657 | 180 mm |
Syringes Omnifix | Braun | 4616057V | 5ml, 10ml and 50ml |
Venflon G22 | Braun | 42690985-01 | Vasofix safety for the ear iv line |