Functional studies of the auditory system in mammals have traditionally been conducted using spatially-focused techniques such as electrophysiological recordings. The following protocol describes a method of visualizing large-scale patterns of evoked hemodynamic activity in the cat auditory cortex using functional magnetic resonance imaging.
Current knowledge of sensory processing in the mammalian auditory system is mainly derived from electrophysiological studies in a variety of animal models, including monkeys, ferrets, bats, rodents, and cats. In order to draw suitable parallels between human and animal models of auditory function, it is important to establish a bridge between human functional imaging studies and animal electrophysiological studies. Functional magnetic resonance imaging (fMRI) is an established, minimally invasive method of measuring broad patterns of hemodynamic activity across different regions of the cerebral cortex. This technique is widely used to probe sensory function in the human brain, is a useful tool in linking studies of auditory processing in both humans and animals and has been successfully used to investigate auditory function in monkeys and rodents. The following protocol describes an experimental procedure for investigating auditory function in anesthetized adult cats by measuring stimulus-evoked hemodynamic changes in auditory cortex using fMRI. This method facilitates comparison of the hemodynamic responses across different models of auditory function thus leading to a better understanding of species-independent features of the mammalian auditory cortex.
Current understanding of auditory processing in mammals is mainly derived from invasive electrophysiological studies in monkeys1-5, ferrets6-10, bats11-14, rodents15-19, and cats20-24. Electrophysiological techniques commonly utilize extracellular microelectrodes to record the activity of single and multiple neurons within a small area of neural tissue surrounding the electrode tip. Established functional imaging methods, such as optical imaging and functional magnetic resonance imaging (fMRI), serve as useful complements to extracellular recordings by providing a macroscopic perspective of simultaneous driven activity across multiple, spatially distinct regions of the brain. Intrinsic signal optical imaging facilitates visualization of evoked activity in the brain by measuring activity-related changes in the reflectance properties of surface tissue while fMRI utilizes the blood-oxygen level-dependent (BOLD) contrast to measure stimulus-evoked hemodynamic changes in brain regions which are active during a particular task. Optical imaging requires direct exposure of the cortical surface to measures changes in surface tissue reflectance that are related to stimulus-evoked activity25. In comparison, fMRI is noninvasive and exploits the paramagnetic properties of deoxygenated blood to measure both cortical surface26-28 and sulcus-based27,29 evoked activity within an intact skull. Strong correlations between the BOLD signal and neuronal activity in nonhuman primate visual cortex30 and in human auditory cortex31 validate fMRI as a useful tool to study sensory function. Since fMRI has been used extensively to study features of the auditory pathway such as tonotopic organization32-36, lateralization of auditory function37, patterns of cortical activation, identification of cortical regions38, effects of sound intensity on auditory response properties39,40, and characteristics of the BOLD response time course29,41 in human, monkey, and rat models, the development of a suitable functional imaging protocol to study auditory function in the cat would provide a useful complement to the functional imaging literature. While fMRI has also been used to explore various functional aspects of the visual cortex in the anesthetized cat26-28,42, few studies have used this technique to examine sensory processing in cat auditory cortex. The purpose of the present protocol is to establish an effective method of using fMRI to quantify function in the auditory cortex of the anesthetized cat. The experimental procedures outlined in this manuscript have been successfully used to describe the features of the BOLD response time course in the adult cat auditory cortex43.
The following procedure can be applied to any imaging experiment in which anesthetized cats are used. Steps which are specifically required for auditory experiments (steps 1.1-1.7, 2.8, 4.1) can be modified to accommodate other sensory stimulus protocols.
All experimental procedures received approval from the Animal Use Subcommittee of the University Council on Animal Care at the University of Western Ontario and followed the guidelines specified by the Canadian Council on Animal Care (CCAC)44. The outlined experiment requires approximately 150 min from animal preparation to recovery. The time course of the experiment is illustrated in Figure 1.
1. Stimulus Equipment Preparation
Figure 2 shows the electronic components and corresponding connections required for generating an auditory stimulus in the MRI scanner. The requirements are as follows: a computer, an external sound card, a stereo power amplifier and an fMRI-compatible earphone system.
2. Animal Preparation
3. Brain Imaging
4. Stimulus Presentation
5. Data Analysis
Representative functional data were acquired in a 7T horizontal bore scanner and analyzed using the Statistical Parametric Mapping toolbox in MATLAB. Robust cortical hemodynamic responses to auditory stimulation have consistently been observed in cats using the described experimental protocol43. Figure 6 illustrates the BOLD activation in 2 animals in response to a 30 sec broadband noise stimulus presented in a block design. T-statistic maps of the broadband noise vs. baseline (no stimulus) contrast in 2 image slice planes reveal contiguous clusters of bilateral acoustically-evoked activity in the auditory cortex (Figures 6a and 6d; cluster-level FWE-corrected threshold: p < 0.05). Figures 6b and 6e show modulations in the BOLD signal, during a single functional run, at the highlighted voxels in Figures 6a and 6d respectively. With a square-wave general linear model fit, one should expect that the BOLD signal will be modulated relative to the baseline (no-stimulus condition) during each presentation of the auditory stimulus in a manner similar to the ON-OFF pattern of the block design. Figures 6c and 6f illustrate the event-related mean time courses of the BOLD response normalized to the mean BOLD baseline signal. In these examples, the BOLD signal exhibits a significant increase relative to the baseline 3-6 sec after the stimulus onset. This increase in the BOLD signal is typically maintained throughout the auditory stimulus presentation then declines to baseline values 6 sec after stimulus offset.
Physiological Parameter | Normal Rangea | Mean Value (Experiment)b |
Heart rate | 110-226 beats/min | 143±4.1 beats/min |
Respiration rate | 20-40 breaths/min | 21±1.6 breaths/min |
End-tidal CO2 | 35-45 mm Hg | 30±1.7 mmHg |
Blood O2 saturation | 90-100%57 | 92±1.2% |
Rectal temperature | 38.5±0.5 °C | N/A |
Table 1. Normal ranges in awake cats and mean values in anesthetized cats for physiological parameters measured during the fMRI procedure. aNormal ranges obtained from guidelines specified by the Canadian Council on Animal Care. 44 b Mean values (± SEM) obtained from N = 7 cats over 20 imaging sessions.
Figure 1. Time course of the experiment. Each step in the experimental procedure is plotted along the time line (in min) relative to the time at which premedication is administered.
Figure 2. Auditory stimulus production equipment. (a) Electronic components used in the experimental protocol. (b) Diagram of connections between each component. The transformer box and the cable assembly of the MRI-compatible earphone system interface at the penetration panel between the scanner room and the computer room.
Figure 3. Experimental setup. (a) MRI-compatible sled. (b) 3-channel cat head RF coil. (c) Side view of an anesthetized cat situated in the sled. (d) Front view of the cat in the sled with its head in the 3-channel RF coil (adapted from Brown et al.43).
Figure 4. Examples of anatomical (left) and functional (right) image slices acquired in a 7T horizontal bore scanner using a 3-channel RF coil. Approximate location of the displayed slice is overlaid on a lateral view of the cat right hemisphere. A: anterior, P: posterior, L: left, R: right.
Figure 5. Schematic of a block design stimulus presentation. Baseline (i.e. no stimulus) blocks are alternated with 30 sec blocks of auditory stimulus presentation. Functional volumes are acquired continuously (every 3 sec) during the run. TA: duration of volume acquisition. TS: duration of stimulus block.
Figure 6. Representative examples of the BOLD response to broadband noise stimulation. (a), (d) T-statistic maps of broadband noise (BBN) vs. baseline (no-stimulus) contrast superimposed on axial (horizontal) anatomical image slices. Approximate locations of displayed slices in (a) and (d) are overlaid on a lateral view of the cat right hemisphere. (b), (e) Raw BOLD signal time courses (in volumes) at the highlighted voxels in (a) and (d) respectively for a single functional run (90 volumes). (c), (f) Event-related averaged BOLD response time courses (in seconds) at the highlighted voxels in (a) and (d) respectively before, during and after a stimulus block. Gray bars represent the period of auditory stimulus presentation. A: anterior, P: posterior, L: left, R: right. Click here to view larger figure.
In designing an fMRI experiment for an anesthetized animal model of auditory function, the following issues should be given careful consideration: (i) the impact of anesthesia on cortical responses, (ii) the effect of background scanner noise, and (iii) the optimization of the data collection phase of the experimental procedure.
While an anesthetized preparation offers the important advantage of producing a prolonged period of sedation and minimizing potential head motion during a functional imaging session, anesthesia is known to impact cortical hemodynamics. The anesthetics described in this protocol are commonly used in electrophysiological (ketamine) and functional imaging (isoflurane) studies of cat auditory46-48 and visual cortex26-28,42 respectively. Although ketamine is known to minimally influence cortical spontaneous activity49, it has been shown to decrease cerebral metabolism and thus the hemodynamic response in the rat auditory cortex at doses of 10 mg/kg50. However, at the doses recommended in this procedure (4 mg/kg), BOLD signal changes of up to 6% have been observed in the cat auditory cortex in response to acoustic stimulation43. Isoflurane is commonly used to explore functional aspects of cat visual cortex; however, it has also been shown to reduce the magnitude of the hemodynamic responses in the cat visual cortex when compared to an awake preparation51. Furthermore, at doses above 1.5%, isoflurane increases cerebral blood flow in the rat45 and heavily impacts neuronal response sensitivity in the cat auditory cortex52. At the doses administered in this protocol (0.4-0.5%), isoflurane serves as a supporting anesthetic agent to the primary anesthetic, ketamine, thus minimizing the negative effects associated with larger dosages. Propofol has also been used in functional imaging studies53, however, it has been shown to reduce somatosensory evoked potentials45 and BOLD responses in auditory cortex53 in a dose-dependent manner. This anesthetic was thus not suitable to provide the required duration of sedation while minimally impacting BOLD responses. The combination of ketamine and isoflurane described in this protocol thus provides several advantages: (i) it produces a period of deep sedation for up to 2.5 hr; (ii) it minimizes head motion such that rotational movements do not typically exceed 0.3° and translational movements do not typically exceed 0.1 mm43; and (iii) it minimally impacts the BOLD response with signal changes of up to 6% being observed.
One of the challenges in executing a functional image study of the auditory system is the impact of the background noise generated by the MRI scanner on the measured BOLD response. In this procedure, the sound stimulus is presented in a block design while functional volumes are continuously acquired during the functional run. The issue of scanner noise is addressed in two ways: (i) by the attenuating properties of the foam ear tips which effectively reduce the background noise by up to 30 dB and (ii) by presenting the sound stimulus at an intensity of about 90 dB SPL. As illustrated in Figure 6, the representative example demonstrates that the BOLD signal is effectively modulated during sound stimulus presentation paired with continuous volume acquisition. While the continuous volume acquisition method has been successfully used to investigate tonotopic organization33,35,36 and spatiotemporal processing54 in the auditory system, this approach limits the investigation of questions such as the effect of stimulus intensity on the BOLD response. The described experimental procedure can be modified to further reduce the impact of scanner noise by increasing the period between volume acquisitions and presenting the sound stimulus in the resulting silent interval. This 'sparse acquisition' approach has been used extensively in auditory studies to describe the properties of the BOLD response time course29,41,43,55, to characterize different regions within the auditory cortex37,38,43,56 and to examine the effect of sound intensity on the BOLD response39,40. During continuous volume acquisition, more volumes are collected in a shorter period of time, thus significantly improving the signal-to-noise ratio. The present protocol can therefore be used in conjunction with sparse acquisition experiments to confirm, localize and clearly delineate acoustically-evoked BOLD activity in auditory functional regions of interest.
Prior to acquiring functional volumes for an auditory experiment, it is important to confirm the presence of acoustically-evoked activity in the auditory cortex. BOLD activation is typically evident in the auditory cortex within 45 min of anesthesia induction (Figure 1). While it is likely that significant BOLD activation can be observed earlier in the experiment, no functional runs were collected prior to this 45 min delay due to the time required for animal preparation and collection of the anatomical scan. To optimize data collection, each functional run can be constructed to maximize the number of volumes collected for each stimulus condition. This can be achieved by modifying the procedure in a few ways. First, the time required to collect each volume can be reduced by decreasing the field of view of the functional image slices. The present procedure describes the acquisition of whole brain images. Instead, the boundaries of the 3-D functional volume can be aligned to the anatomical boundaries of the spatially-localized auditory cortex. Second, the volume acquisition time can also be reduced by decreasing the in-plane resolution. However, an in-plane resolution of at least 0.75 mm2 appears sufficient to resolve regional differences in functionality within the auditory cortex. If an increase in the in-plane resolution is desired, the corresponding increase in volume acquisition time can be balanced by reducing the number of slices within the 3-D functional volume and, instead, focusing on a particular sub-region within the auditory cortex.
Overall, the noninvasive nature of fMRI facilitates repeated functional experiments in a single animal over an extended period of time. This technique is therefore ideal for longitudinal investigations which require data collection at multiple time points and can potentially reduce the number of animals required for a given study.
The authors have nothing to disclose.
The authors would like to acknowledge the contributions of Kyle Gilbert, who designed the custom RF coil, and Kevin Barker, who designed the MRI-compatible sled. This work was supported by the Canadian Institutes of Health Research (CIHR), Natural Sciences and Engineering Research Council of Canada (NSERC), and Canada Foundation for Innovation (CFI).
Material | |||
Atropine sulphate injection 0.5 mg/mL | Rafter 8 Products | ||
Acepromazine 5 mg/mL | Vetoquinol Inc. | ||
Ketamine hydrochloride 100 mg/mL | Bimeda-MTC | ||
Dexmedetomidine hydrochloride (Dexdomitor 0.5 mg/mL) | Orion Pharma | ||
Isoflurane 99.9% | Abbott Laboratories | ||
Lidocaine (Xylocaine endotracheal 10 mg/metered dose) | Astra Zeneca | ||
Lubricating opthalmic ointment (Refresh Lacri Lube) | Allergan Inc. | ||
Saline 0.95% | |||
IV Catheter 22g (wings) | |||
IV Extension Set | Codan US Corp. | BC 269 | |
IV Administration Set 10 drips/mL | |||
Endotracheal tube 4.0 | |||
Heating pads (Snuggle Safe) | Lenric C21 Ltd. | ||
Syringe 60 mL | |||
Equipment | |||
External sound card | Roland Corporation | Cakewalk UA-25EX | |
Stereo power amplifier | Pyle Audio Inc. | Pyle Pro PCAU11 | |
MRI-compatible insert earphone system | Sensimetric Corporation | Model S14 | |
Foam ear tips for insert earphones | E-A-R Auditory Systems | Earlink 3B | |
End-tidal CO2 monitor | Nellcor | N-85 | |
MRI-compatible pulse oximeter | Nonin Medical Inc. | Model 7500 | |
Syringe pump | Harvard Apparatus | 70-2208 |