Source: Iyer, M. R. et al., Isolating and Culturing Vestibular and Spiral Ganglion Somata from Neonatal Rodents for Patch-Clamp Recordings. J. Vis. Exp. (2023).
This video showcases a method for isolating vestibular neurons from a mouse pup's inner ear. It meticulously outlines the steps involved in dissecting the inner ear, harvesting the vestibular ganglion, and subsequently dissociating the ganglion into single cells. These cells are then cultured on glass-bottom dishes to establish a vestibular neuron culture.
All procedures involving sample collection have been performed in accordance with the institute's IRB guidelines.
1. Preparations
NOTE: The solutions and tools described in this section can be made well ahead of time and used on the day of dissection and recording.
2. Fabricating trituration pipettes
NOTE: Trituration pipettes can be reused for multiple experiments. Flush the pipettes with ethanol, water, and L-15 solution before each use and clean them with water and ethanol after each use. Carefully store between uses.
3. Extraction of vestibular ganglion and plating of vestibular neurons
The authors have nothing to disclose.
B27 Supplement (50x), serum free | Thermo Fisher Scientific | 17504044 | additive to culture medium, for SGN |
Beakers (1000, 100, 10) milliliter | |||
bench-top centrifuge | USA Scientific | 2641-0016 | |
Bunsen burner | |||
Collagenase | Sigma-Aldrich | C5318 | one out of three enzyme to digest tissue |
Coverglass, rectangular, #1 thickness, 22×40 | Warner Instruments | 64-0707 | |
DMSO | Biotium | 90082 | |
Dnase I,from bovine pancreas | Sigma-Aldrich | 11284932001 | one out of three enzyme to digest tissue |
Dumont #3 Forceps (Blunt) | Fine Science Tools | 11231-30 | |
Dumont #5 Forceps (Fine) | Fine Science Tools | 11251-10 | |
Dumont #55 Forceps (Fine) | Fine Science Tools | 11255-20 | |
Ethanol | Decon Labs | 2716 | for cleaning head and around dissection bench |
Filamented Borosilicate Capillaries for electrodes | Sutter Instruments | BF140-117-10 | |
Fine-edged dissection blade | Fine Science Tools | 10010-00 | |
Glass Pasteur Pipettes | VWR | 14673-010 | to pull trituration pipettes |
Heat-inactivated Fetal Bovine Serum | Thermo Fisher Scientific | 16140063 | additive to culture medium |
HEPES | Sigma-Aldrich | H3375-100G | for pH buffering all solutions in protocol |
Hot plate / magnetic stirrers | VWR | 76549-914 | |
Insulated bucket filled with ice | to keep all samples and solutions cool | ||
Large Spring Scissors | Fine Science Tools | 14133-13 | |
Leibovitz medium | Sigma Aldrich | L4386 | dissection and bath solutions |
Low-profile-bath recording chamber for culture dishes | Warner Instruments | 64-0236 | |
luer-lok syringes, 30 ml | BD | 302832 | for drawing L-15/HEPES/HEPES solution. |
MEM + Glutamax Supplement | Fisher Scientific | 41-090-101 | base of the culture medium |
microFil needle for filling micropipettes – 34 gauge | World Precision Instruments | MF34G | |
N2 Supplement (100x) | Thermo Fisher Scientific | 17502-048 | additiive to culture medium, for SGN |
NaOH (1 M) | Thomas Scientific | 319511-500ML | for titration pH |
Oxygen, Medical grade, with adequate regulator and tubing | USC Material Management | MEDOX200 (Identifier: 00015) | for dissolving into dissection and bath solutions |
Parafilm | Bemis | PM992 | |
Pasteur pipette bulb (3 ml) | Fisher Scientific | 03-448-25 | bulb for trituration pipettes |
Penicillin/Streptomycin | Thermo Fisher Scientific | 15140122 | additive to prevent contamination of culture medium |
Pentobarbital based euthanasia solution (e.g., Fatal Plus. 50 – 60 mg/kg dosing) | MWI Animal Health | 15199 | for euthanasia |
PES membrane filters , 0.2 micrometer | Nalgene | 566-0020 | for filtering solutions |
PES membrane sterile syringe filters, 0.22 um, 30 mm | CELLTREAT | 229747 | for filtering solutions drawn into syringes |
Petri dishes, 35 x 10 mm | Genessee Scientific | 32-103 | for micro dissection and to hold Tip dip solution in perforated-patch configuration |
Petri Dishes, 60 x 15 mm | Midland Scientific | P7455 | for gross dissection |
pH Meter | Mettler Toledo | Model S20 | |
Pipettors (1000, 200, 10) microliter | USA Scientific | ||
Poly-d-lysine coated glass bottomed culture dish | Mattek | P35GC-0-10-C | to plate neurons for culture |
Quick change platform, heated base, for 35 mm culture dishes | Warner Instruments | 64-0375 | |
Reference Cell | World Precision Instruments | RC1T | |
Scalpel blade | Miltex | 4-315 | |
Scalpel Handle | Fine Science Tools | 10003-12 | |
Scientific Scale | Mettler Toledo | XS64 | |
Serological Pipettes (10, 25) milliliter | Fisher Scientific | ||
Silicone Grease Kit (for sealing coverglass and chamber) | Warner Instruments | 64-0378 | |
Small Animal Guillotine | Kent Scientific | DCAP | |
Small animal guillotine | Kent Scientific | DCAP | for decapitation if dissecting rats older than P15. |
Stereo Dissection Microscope | Zeiss | Stemi 2000 | |
Straight surgical scissors | Fine Science Tools | 14060-09 | |
Syringe (3, 10, 30) milliliter | |||
Trypsin | Sigma Aldrich | T1426 | one out of three enzyme to digest tissue |
Tuberculin syringe | Covidien | 8881500105 | for delivering euthanasia solution by intraperitoneal injection |
Vannas Spring Scissor, 2.5 mm Cutting Edge | Fine Science Tools | 15000-08 | |
Volumetric flask, 1000 milliliter | |||
Vortex | VWR | 945300 | |
Water, sterile u ltrapure, R>18.18 megaOhms cm (e.g., filtered by a Millipore-Sigma water purification system) | Millipore-Sigma | CDUFBI001 |