This protocol describes implantation of a glass window onto the spinal cord of a mouse to facilitate visualization by intravital microscopy.
This protocol describes a method for spinal cord laminectomy and glass window implantation for in vivo imaging of the mouse spinal cord. An integrated digital vaporizer is utilized to achieve a stable plane of anesthesia at a low-flow rate of isoflurane. A single vertebral spine is removed, and a commercially available cover-glass is overlaid on a thin agarose bed. A 3D-printed plastic backplate is then affixed to the adjacent vertebral spines using tissue adhesive and dental cement. A stabilization platform is used to reduce motion artifact from respiration and heartbeat. This rapid and clamp-free method is well-suited for acute multi-photon fluorescence microscopy. Representative data are included for an application of this technique to two-photon microscopy of the spinal cord vasculature in transgenic mice expressing eGFP:Claudin-5 — a tight junction protein.
Transgenic animal models expressing fluorescent proteins, when combined with intravital microscopy, provide a powerful platform for addressing biology and pathophysiology. To apply these techniques to the spinal cord, specialized protocols are required to prepare the spinal cord for imaging. One such strategy is to conduct a laminectomy and spinal cord window implantation. The key features of an ideal laminectomy protocol for microscopy include preservation of native tissue structure and function, stability of the imaging field, quick processing time, and reproducibility of results. A particular challenge is to stabilize the imaging field against the motion induced by respiration and heartbeat. Multiple ex vivo and in vivo strategies have been reported to achieve these goals1,2,3,4,5. Most in vivo methods involve clamping the sides of the spinal column2,4 and is often followed by implanting a rigid metal apparatus3,4 for stability during surgery and downstream imaging applications. Clamping the spinal column can potentially compromise blood flow and induce blood-brain barrier (BBB) protein remodeling.
The purpose of this method is to make the intact spinal cord available for optical imaging in the living mouse while minimizing the invasiveness of the protocol and improving outcomes. We describe a single laminectomy and cover-glass implantation procedure paired with a minimally invasive oval plastic 3D-printed backplate that still achieves robust mechanical stability. The backplate is directly adhered to the anterior and posterior vertebral spines with dental cement. The backplate is equipped with lateral extension arms with screw holes that rigidly attach to the microscope stage via a metal arm. This effectively anchors the intact anterior and posterior vertebra to the microscope stage, providing mechanical resistance to the motion artifact that would otherwise be introduced by respiration and heartbeat. The method has been optimized for laminectomy of a single vertebra at thoracic level 12, omitting the clamps utilized in alternative strategies for stability during in vivo imaging. The procedure is rapid, taking approximately 30 min per mouse.
This protocol can be used to study disease mechanisms of the BBB. The BBB is a dynamic microvascular system comprised of endothelial cells, vascular smooth muscle, pericytes, and astrocyte foot processes that provide a highly selective environment for the central nervous system (CNS). Representative data depict the application of this protocol in transgenic mice engineered to express enhanced green fluorescent protein (eGFP):Claudin-5, a BBB tight junction protein. The provided backplate printing files can also be customized for alternative applications.
All experiments follow the University of Illinois, Chicago Institutional Animal Care and Use Committee protocols. This is a terminal procedure.
1. Reagent Preparation
2. Backplate 3D Printing
3. Surgical Preparation
4. Laminectomy
5. Cover-glass Implantation
6. Imaging Preparation
Implanted glass windows and intravital two-photon microscopy provides a useful tool for assessing dynamic changes in CNS proteins. The functional integrity of the BBB is influenced by the expression, subcellular localization, and turnover rates of tight junction proteins7. Previous studies have demonstrated that tight junction proteins undergo rapid and dynamic remodeling at steady state8. The currently described laminectomy and glass window preparation has been used in transgenic eGFP:Claudin-5 mice9, which bear fluorescent tight junction proteins, to assess BBB tight junction remodeling in the experimental autoimmune encephalomyelitis (EAE) model of multiple sclerosis10. In the representative data, imaging of eGFP:Claudin-5 was achieved with a two-photon microscope with 920 nm excitation, a 40× infrared objective (0.8 NA), and a green fluorescence emission filter (Figure 4). Optical stacks were sampled at 2 µm axial steps to 100 µm beneath the dural surface. Data depict visualization of the fluorescently labeled junctions throughout a vascular plexus. Single optical slices and Z-projection images are included (Figure 4). The clear delineation of tight junction structures in the Z-projection (Figure 4B) indicates that minimal X-Y image displacement is produced after successful laminectomy, window placement, and backplate implantation.
Figure 1. Custom printed backplate stabilization device. A) Orthogonal backplate views. B–D) Triangulated mesh models of dorsal and ventral surfaces of the backplate. E) Correctly printed backplate. F) Incorrectly printed backplate. See Supplementary Files 1 and 2. Please click here to view a larger version of this figure.
Figure 2. Surgical steps for laminectomy. A) Isoflurane anesthesia delivery system utilizing an integrated digital vaporizer including (i) a touch screen display for controlling anesthesia, (ii) control dials, (iii) inputs for optional add-on physiology modules, (iv) anesthesia concentration adjustment knob, (v) syringe pump pusher block, (vi) syringe with isoflurane, (vii) integrated digital vaporizer, (viii) inspiration tubing, (ix) inspiration tubing for induction chamber, (x) induction chamber, (xi) inspiration tubing for nose-cone, (xii) expiration tubing for nose-cone, (xiii) expiration tubing for induction chamber. B) Instruments used in the laminectomy include (i) feedback controlled heating unit, (ii) K-coupled rectal thermometer probe, (iii) flexible silicone heating pad, (iv) #11 blade, (v) #5 forceps, (vi) toothed titanium forceps, (vii) titanium iris scissors, (viii) bone microdrill, (ix) cautery gun, (x) 3D printed backplate, (xi) absorbent foam surgical spears, (xii) ceramic mixing tray for acrylic resin, (xiii) acrylic resin and accelerant, (xiii) tissue adhesive, (xiv) ophthalmic lubricant, (xv) 3 mm cover-glass. C) Stereomicroscope and surgical platform. During surgery, the surgical platform sits on a gliding stage (silver and black round base on microscope stage). D) Mouse situated on the custom surgical platform with heated bed, after superficial midline incision. The isoflurane nosecone holder is adjustable in the Y- and Z-axes to accommodate small and large mice. Ear bars stabilize the head with respect to the nosecone. The rectal thermoprobe measures core temperature. E) Surgical field at the step of muscle removal. F) Surgical field after removal of muscle. G) Surgical field during the thinning of the vertebral bone. H) Surgical field after removal of the vertebral bone. I) Surgical field during placement of coverglass. J) Surgical field after placement of coverglass. K) Surgical field during initial coating with acrylic. L) Surgical field after completion of backplate implanation. M-N) Mouse positioned in the surgical station after completed laminectomy. The brass fork is adjustable in X-, Y-, and Z-axes for positioning over spinal cord laminectomy site. The fork is mechanically anchored to the surgical platform to provide optimal stabilization of the imaging field during surgery and downstream applications including two-photon intravital microscopy. During surgery, the surgical platform is mounted on a gliding stage. Please click here to view a larger version of this figure.
Figure 3. Schematic depiction of anatomic placement of the spinal cord window. A) Schematic depiction of the superior view of a lower thoracic vertebral body, spinous process, and spinal cord (sc) segment. A dotted circle depicts the seat of the articular process, the main support point for backplate adhesion. B) Schematic depiction of the superior view of the spinal cord window. The target vertebral spine (here, T12) has been removed. A thin layer of agarose overlays the spinal cord. A coverglass rests on top of the agarose. Tissue adhesive is applied over the transverse processes (and, not shown here, on the exposed articular process of the adjacent, intact vertebral spines). Dental cement overlays the tissue adhesive. The backplate adheres to the tissue cement, resting on the transverse processes (shown) and the articular process of the adjacent, intact vertebral spines (not shown in this panel). An additional thin layer of dental cement is applied on the interior of the backplate rim. The backplate is depicted in a cutaway view to visualize the cover-glass. C) Schematic depiction of the lateral view of the spinal cord window. The target vertebral spine (here, T12) has been removed. A thin layer of agarose overlays the spinal cord. A cover-glass rests on top of the agarose. Tissue adhesive is applied over the exposed articular process of the adjacent, intact T11 and T13 vertebral spines. Dental cement overlays the tissue adhesive. The backplate adheres to the tissue cement, resting on the transverse processes and the articular process of the adjacent, intact vertebral spines (shown). The backplate is depicted in a cutaway view; in a true lateral view the agarose and cover-glass would be obscured by the lateral wall of the backplate. Anatomic structures are based on detailed magnetic resonance imaging of the C57Bl/6 spinal column conducted by Harrison and colleagues 11. Please click here to view a larger version of this figure.
Figure 4. Tight junction microstructure visualized by eGFP:Claudin-5 in the mouse spinal cord by intravital two-photon microscopy. A) Single optical section taken at 30 µm beneath the dural surface in a healthy eGFP:Claudin-5 mouse. Red arrow depicts an eGFP:Claudin-5 tight junction segment extending perpendicular to the longitudinal tight junction axis. Scale bar represents 5 µm. Inset: scale bar represents 10 µm. B) Z-projection of the vascular network extending 100 µm beneath the dural surface of the healthy mouse spinal cord. The optical stack was sampled at 2 µm axial step size and includes the slice from panel A. No image alignment has been performed. Sharp delineation of the junctional structures in the Z-projection demonstrates minimal image displacement between consecutive frames. C) Representative subset of optical slices taken at 10 µm intervals from the resultant Z-stack. Please click here to view a larger version of this figure.
Supplemental File 1. Please click here to download this file.
Supplemental File 2. Please click here to download this file.
The method described here allows for stable imaging of the spinal cord in mice through a glass window. This method has been applied to assess BBB remodeling in transgenic eGFP:Claudin5+/- mice that express a fluorescent BBB tight junction protein, but it could be applied equally well for studies of any fluorescent proteins or cells in the spinal cord.
Multiple methods for laminectomy and spinal cord stabilization have been developed. All protocols address stabilizing the spinal cord during imaging and window implementation for visual access to the structure of interest. The number of vertebra removed and the degree of invasiveness of the available protocols vary (e.g., components glued on the surface of superficial bone, as in the present protocol, versus embedded more deeply). Davalos and Akassoglou2 developed a laminectomy method using removable clamps on each side of the spinal column and one clamp at the base of the tail of the mouse in order to stabilize the spinal cord. This innovative strategy to suspend the animal relieved some of the thoracic displacement caused by the movement of the lungs expanding against the surgical table. To create a well for containing immersion fluid for a water-immersion microscopic lens, a rim of gelatin seal (e.g. Gelseal) was made around the spinal cord and filled with aCSF. The seal rim could be disrupted during imaging, but could also be easily wiped away at the end of the session to enable wound closure and subsequent reimaging. This method has been widely adopted12,13. Other groups have developed alternative stabilization methods. Fenrich et al.4 hand-prepared modified paper clips as a way to secure the spinal column. These modified paper clips were secured in the lateral vertebral pedicles with cyanoacrylate glue and maintained as permanently implanted handles for a removable external clip and external holding fork for excellent motion stability. Cupido and colleagues have presented variations on the aforementioned methods with incorporation of agarose overlaid onto the cord2,4,12. Farrar and Schaffer3 developed a quadrilateral metal stabilizer that could allow for the implementation of a glass window onto three vertebrae rather than only one. This method also allowed the spinal cord to be attached with screws to a larger bridge stabilizer during imaging to reduce potential motion.A miniaturized one-photon microscope implanted directly onto the laminectomy imaging chamber has also been developed for in vivo recording in freely moving mice at the one-photon level, but is not yet readily available to most laboratories13. In a different approach, Weinger et al.1 dissected an entire spinal cord and embedded it in agarose for ex vivo imaging, which allows for unsurpassable motion stability and access to the ventral spinal cord, but abrogates blood flow. Some limitations of these developments include lengthy surgical time4, possible disruption of the gelatin seal rim2, the need to customize the cover-glass dimensions to fit the desired area of spinal cord4, manual modification of paper clips4,12, relatively invasive surgical techniques12,14, and air bubbles forming when using the silicon elastomer3,4.
We have developed an alternative method that offers several advantages. This protocol has been optimized to reduce the amount of time spent during surgery. Whereas some surgical protocols require longer procedure times ranging from an hour and a half4 to an hour3; once mastered, this laminectomy method can be performed in approximately 30 min. Reducing the time spent in surgery can decrease physiologic stress to the mouse, and facilitate higher-throughput experimentation. This protocol removes a single vertebra, and incorporates superficial adhesion of the stabilization device making it less invasive than some comparable protocols4,5,12,14. Like the method of Figley et al., by utilizing a plastic implant this protocol offers compatibility with acoustic imaging5.
To avoid light scattering (during intravital microscopy) that could be caused by the differences between the refractive indices of air, water, and tissue, most protocols overlay an optically transparent substrate over the exposed spinal cord. Common substrates include high purity, low-melting temperature agarose10,12 or silicone polymers3,4,5. Agarose offers the advantage of ease of use, with minimal bubble formation, and is appropriate for acute imaging sessions. To protect the tissue from heat damage, it is convenient to heat the agarose to beyond the melting point and then allow it to cool to ~39 °C in a water bath during the laminectomy, so it can be ready at the appropriate time for application to the exposed spinal cord. For chronic imaging, silicone polymers are more resistant to dehydration. Pilot trials during the development of the current protocol omitted either the agarose layer or the overlying cover-glass, and found that the consequent light scatter reduced available depth of imaging.
A differentiating feature of this protocol is the incorporation of a 3D printed backplate and supportive backplate fork holder. After the laminectomy and window implantation, the preparation is stabilized by the addition of an 3D-printed oval backplate that is fixed in place with dental cement. The backplate serves two functions: first, it provides structural support and stabilization of the spinal cord, and second, it creates a lip to hold fluid for immersion objectives for microscopy. In prototypes of this setup, commercially available pillar posts, adaptors, and holding forks were used; we have recently switched to custom machined parts as depicted here. In either case, the essential feature is to provide structural rigor to stabilize the imaging field against the perturbations in space and time induced by heartbeat and respiration. Although the body of the animal is resting loosely on the heating pad, the spinal cord and its imaging field are slightly suspended from the holding fork, which also decreases respiratory displacement. The plastic substrate offers slight flexibility to accommodate tension from screwing into the plate holder. The black plastic color used for printing reflects minimal light into the fluorescence field. Through these methods, we successfully generate image stacks that can be used without post hoc alignment adjustment. Furthermore, the 3D backplate described herein is inexpensive to produce, costing only pennies in material for each print, once the printer is purchased. Furthermore, the costs of 3D printers have fallen in the recent years. The 3D printed backplate structural files (See Supplementary Files 1 and 2) published with this protocol can be readily modified to accommodate individual laboratory needs. We designed the long dimension of the backplate to accommodate the intervertebral space created by removal of thoracic 12 vertebral spine, which overlies the lumbar 2/3 spinal cord segments11. To apply this technique to a different vertebral section, the accompanying CAD files can be modified.
This protocol utilizes a commercially available low-flow anesthesia system that deploys a digital integrated direct injection vaporizer as an alternative to the traditional passive vaporizer. The major feature of the low-flow unit is the reduced operator exposure to isoflurane, a substantial health benefit. The low-flow anesthesia unit also offers cost savings due to the reduced consumption of isoflurane and utilization of room air instead of compressed gas. In the present study, 2% isoflurane delivered by integrated digital vaporizer at 150 mL/min, together with feedback-controlled thermal support, achieved a stable plane of anesthesia and appropriate maintenance of core body temperature. Consistent with this, published comparisons of digital integrated vaporizers and traditional vaporizers have also concluded that the digital integrated vaporizer yields a stable plane of anesthesia and good preservation of core body temperature, heart rate, respiratory rate, and recovery while utilizing less isoflurane15,16.
A non-steroidal anti-inflammatory drug (NSAID) such as carprofen can be administered Pre-operatively as a supplementary analgesic. Over the course of few hours, NSAIDs inhibit inflammatory cytokine transcription and interstitial edema; multi-day administration attenuates severity of neuroinflammatory diseases including experimental autoimmune encephalomyelitis, an animal model of multiple sclerosis17,18. Particularly in the study of neuroinflammatory disease, the beneficial effects of carprofen analgesia must be carefully weighed against disease modifying effects when determining analgesia and anesthesia for an experiment in close coordination with appropriate regulatory boards.
A limitation of this method is that it is not readily amenable to repeated imaging sessions across multiple days. The main reason is that the backplate structure is too large to close the skin over. Therefore, there is a risk that a mouse would dislodge the backplate upon waking from anesthesia. If repeated imaging was essential, there are several strategies that could be deployed, including reducing the size of the backplate, or changing the mount. As with any surgical procedure, there is a learning curve for operators. Close coordination with institutional animal care offices and review boards is required.
The authors have nothing to disclose.
S.E. Lutz is supported by the National Center for Advancing Translational Sciences, National Institutes of Health, under Grant KL2TR002002 and University of Illinois Chicago College of Medicine start-up funds. Simon Alford is supported by RO1 MH084874. The content is solely the responsibility of the authors and does not necessarily represent the official views of the NIH. The authors thank Dritan Agalliu in the Department of Neurology at Columbia University Medical Center for the Tg eGFP:Claudin-5 mice, scientific discussions, and insights into the development of the surgical protocol and imaging applications. The authors thank Sunil P. Gandhi in the Department of Neurobiology and Behavior at University of California, Irvine for designing the first prototype of the stereotactic apparatus and animal temperature controller, discussion of the surgical protocol, and training in two-photon microscopy. The authors also thank Steve Pickens (W. Nuhsbaum, Inc.) for assistance in customizing the surgical stereomicroscope, and Ron Lipinski (Whale Manufacturing) for machining stereotactic parts.
3D printer | Raise3D | Pro2 | For printing backplates |
PLA 3D printing filament | Inland | PLA+-175-B | Black plastic 3D printing material |
3D CAD software | Dassault Systemes | Solidworks software | used to design 3D shapes |
3D printer software | Raise3D | Ideamaker software | software used to interface with the 3D printer |
3D printed oval backplate | custom | Stabilizing imaging field | |
Surgical dissecting microscope | Leica | M205 C | Equipped with Leica FusionOptics, Planapo 0.63x M-series objective, and gliding stage |
Microscope camera | Leica | MC170 | HD color camera for visualizing surgical field |
Gliding stage | Leica | 10446301 | The gliding stage is constructed of two metal plates. The base plate is fixed. The upper plate slides on greased interface to allow rotational and linear movement. |
Surgical station and stabilization fork | Whale Manufactoring | custom | Laminectomy |
SomnoSuite low-flow isoflurane delivery unit | Kent Scientific | SS-01 | Surgical anesthesia administration with integrated digitial vaporizer |
Stainless steel 1.5 inch mounting post | ThorLabs | P50/M | For mounting surgical station onto optical table for two-photon imaging |
Counterbored Clamping Fork for 1.5" mounting Post | ThorLabs | PF175 | For stabilizing surgical station mount onto optical table for two-photon imaging |
Ideal bone microdrill | Harvard apparatus | 72-6065 | Thinning bone for laminectomy |
Water bath | Fisher Scientific | 15-462-10 | Warming saline |
Cautery gun | FST | 18010-00 | Cauterizing minor bleeds |
Heating pad | Benchmark | BF11222 | 1.9” x 4.5” silicone heater with 20” Teflon leads, 10W, 5V |
K type thermocoupled rectal probe | Physitemp | RET3 | Measuring mouse body temperature |
petroleum jelly | Sigma | 8009-03-8 | Lubricating rectal probe |
Feedback-regulated thermal controller | custom | NA | Commercially available alternatives include the Physitemp TCAT series |
PVA Surgical eye spears | Beaver-visitec international | 40400-8 | Absorbing blood |
Electric trimmer | Wahl | 41590-0438 | Trimming mouse fur |
Blade, #11 | FST | 14002-14 | Surgical tool |
Forceps, #5 | FST | 11254-20 | Surgical tool |
Forceps, #4 | FST | 14002-14 | Surgical tool |
Titatnium toothed forceps | WPI | 555047FT | Surgical tool |
Titanium Iris scissors | WPI | 555562S | Surgical tool |
Vetbond tissue adhesive | 3M | 084-1469SB | Preparing tissue surface for dental acrylic |
Ceramic mixing tray | Jack Richeson | 420716 | Mixing dental acrylic agent with accelerant |
Orthojet dental acrylic | Lang Dental | 1520BLK, 1503BLK | Permanently bonding backplate to tissue |
Small round cover glass, #1 thickness, 3 mm | Harvard apparatus | 64-0720 | optical window |
NaCl | Fisher Scientific | 7647-14-5 | For aCSF |
KCl | Fisher Scientific | 7447-40-7 | For aCSF |
Glucose | Fisher Scientific | 50-99-7 | For aCSF |
HEPES | Sigma | 7365-45-9 | For aCSF |
MgCl2·6H2O | Fisher Scientific | 7791-18-6 | For aCSF |
CaCl2·2H2O | Fisher Scientific | 10035-04-8 | For aCSF |
Carprofen | Rimadyl | QM01AE91 | Analgesia |
Bacteriostatic water | Henry Schein | 2587428 | Diluent for carprofen |
Isoflurane | Henry Schein | 11695-6776-2 | Anesthesia |
Lactated ringer solution | Baxter | 0338-0117-04 | Hydration for mouse |
Agarose High EEO | Sigma | A9793 | gel point 34-37 degrees C |
Opthalmic lubricating ointment | Akwa Tears | 68788-0697 | Prevent corneal drying |
MOM Two-Photon Microscope | Sutter |