Here, we present an experimental method for decoupling the interdependent Coriolis-force and rotating-buoyancy effects on full-field heat transfer distributions of a rotating channel.
An experimental method for exploring the heat transfer characteristics of an axially rotating channel is proposed. The governing flow parameters that characterize the transport phenomena in a rotating channel are identified via the parametric analysis of the momentum and energy equations referring to a rotating frame of reference. Based on these dimensionless flow equations, an experimental strategy that links the design of the test module, the experimental program and the data analysis is formulated with the attempt to reveal the isolated Coriolis-force and buoyancy effects on heat transfer performances. The effects of Coriolis force and rotating buoyancy are illustrated using the selective results measured from rotating channels with various geometries. While the Coriolis-force and rotating-buoyancy impacts share several common features among the various rotating channels, the unique heat transfer signatures are found in association with the flow direction, the channel shape and the arrangement of heat transfer enhancement devices. Regardless of the flow configurations of the rotating channels, the presented experimental method enables the development of physically consistent heat transfer correlations that permit the evaluation of isolated and interdependent Coriolis-force and rotating-buoyancy effects on the heat transfer properties of rotating channels.
While thermodynamic laws dictate the improved specific power and thermal efficiency of a gas turbine engine by elevating the turbine entry temperature, several hot engine components, such as turbine blades, are prone to thermal damage. Internal cooling of a gas turbine rotor blade permits a turbine entry temperature in excess of the temperature limits of the creep resistance of the blade material. However, the configurations of the internal cooling channels must comply with the blade profile. In particular, the coolant rotates within the rotor blade. With such harsh thermal conditions for a running gas turbine rotor blade, an effective blade cooling scheme is crucial to ensure the structure's integrity. Thus, the local heat transfer properties for a rotating channel are important for the efficient usage of the limited coolant flow available. The acquisition of useful heat transfer data that are applicable to the design of the internal coolant passages at realistic engine conditions is of primary importance when an experimental method is developed for measuring the heat transfer properties of a simulated cooling passage inside a gas turbine rotor blade.
Rotation at a speed above 10,000 rpm considerably alters the cooling performance of a rotating channel inside a gas turbine rotor blade. The identification of engine conditions for such a rotating channel is permissible using the similarity law. With rotation, the dimensionless groups that control the transport phenomena inside a radially rotating channel can be revealed by deriving the flow equations relative to a rotating frame of reference. Morris1 has derived the momentum conservation equation of flow relative to a rotating frame of reference as:
(1)
In equation (1), the local fluid velocity, v̄, with the position vector, r̄, relative to a frame of reference rotating at the angular velocity, ω, is affected by the Coriolis acceleration in terms of 2(ω×v̄), the decoupled centripetal buoyancy force, β(T–Tref)(ω×ω×r̄), the driven piezo-metric pressure gradient, , and the fluid dynamic viscosity, ν. The referenced fluid density, ρref, is referred to a pre-defined fluid reference temperature Tref, which is typical of the local fluid bulk temperature for experiments. If the irreversible conversion of mechanical energy into thermal energy is negligible, the energy conservation equation is reduced to:
(2)
The first term of equation (2) is obtained by treating the specific enthalpy to be directly related to the local fluid temperature, T, via the constant specific heat, Cp. As the perturbation of fluid density caused by the variation of fluid temperature in a heated rotating channel provides considerable influence on the motion of fluids when it links with the centripetal acceleration in equation (1), the fluid velocity and temperature fields in an axially rotating channel are coupled. Also, both Coriolis and centripetal accelerations vary simultaneously as the rotating speed is adjusted. Thus, the effects of Coriolis force and rotating buoyancy on the fields of fluid velocity and temperature are naturally coupled.
Equations (1) and (2) in the dimensionless forms disclose the flow parameters that govern the heat convection in a rotating channel. With a basically uniform heat flux imposed on a rotating channel, the local fluid bulk temperature, Tb, increases linearly in the streamwise direction, s, from the reference inlet level, Tref. The local fluid bulk temperature is determined as Tref + τs, where τ is the gradient of the fluid bulk temperature in the direction of flow. Substitutions of the following dimensionless parameters of:
(3)
(4)
(5)
(6)
(7)
into equations (1) and (2), where Vmean, N and d respectively stand for the mean flow through velocity, rotating velocity and channel hydraulic diameter, the dimensionless flow momentum and energy equations are derived as equations (8) and (9) respectively.
(8)
(9)
Evidently, η in equation (9) is a function of Re, Ro, and Bu = Ro2βτdR, which are respectively referred to as Reynolds, rotation and buoyancy numbers. The Rossby number that quantifies the ratio between inertial and Coriolis forces is equivalent to the inverse rotation number in equation (8).
When Tb is calculated as Tref + τs in a rotating channel subject to a uniform heat flux, the τ value can be alternatively evaluated as Qf/(mCpL) in which Qf, m and L are the convective heating power, coolant mass flow rate and channel length, respectively. Thus, the dimensionless local fluid bulk temperature, ηb, is equal to s/d and the dimensionless temperature at channel wall, ηw, yields [(Tw–Tb)/Qf][mCp][L/d]+s/d. With the convective heat transfer rate defined as Qf/(Tw–Tb), the dimensionless wall-to-fluid temperature difference, ηw–ηb, is convertible into the local Nusselt number via equation (10) in which ζ is the dimensionless shape function of heating area and channel sectional area.
(10)
With a set of predefined geometries and the hydrodynamic and thermal boundary conditions, the dimensionless groups controlling the local Nusselt number of a rotating channel are identified as:
(11)
(12)
(13)
With experimental tests, the adjustment of rotating speed, N, for varying Ro to generate the heat transfer data at different strengths of Coriolis forces inevitably changes the centripetal acceleration, and thus, the relative strength of rotating buoyancy. Moreover, a set of heat transfer data collected from a rotating channel is always subject to a finite degree of rotating buoyancy effect. To disclose the individual effects of Coriolis-force and buoyancy on the heat transfer performance of a rotating channel requires the uncoupling of the Ro and Bu effects on Nu properties through the post data processing procedure that is inclusive in the present experimental method.
The engine and laboratory flow conditions for a rotating channel inside a gas turbine rotor blade can be specified by the ranges of Re, Ro and Bu. The typical engine conditions for the coolant flow through a gas turbine rotor blade, as well as the construction and commissioning of the rotating test facility that allowed experiments to be performed near the actual engine conditions was reported by Morris2. Based on the realistic engine conditions summarized by Morris2, Figure 1 constructs the realistic operating conditions in terms of Re, Ro and Bu ranges for a rotating coolant channel in a gas turbine rotor blade. In Figure 1, the indication of an engine's worst condition is referred to as the engine running condition at the highest rotor speed and the highest density ratio. In Figure 1, the lower limit and worst engine operating conditions respectively emerge at the lowest and highest engine speeds. It is extremely difficult to measure the full-field Nu distribution of a rotating channel running at a real engine speed between 5000 and 20,000 rpm. However, based on the similarity law, laboratory-scale tests have been conducted at reduced rotating speeds but with several attempts to provide a full coverage of the real-engine Re, Ro and Bu ranges. As an innovative experimental method, the NASA HOST program3,4,5,6 adopted the high-pressure tests for increasing the fluid densities at the predefined Re in order to extend the Ro range by reducing the mean fluid velocity. In this regard, the specific relationships between Re, Ro and Bu for an ideal gas with a gas constant, Rc, and viscosity, μ, are related as:
(14)
(15)
To bring the laboratory conditions into the nominal correspondence with engine conditions seen in Figure 1, the rotating speed, N, coolant pressure, P, channel hydraulic diameter, d, rotating radius, R, and wall-to-fluid temperature difference, Tw–Tb, need to be controlled for matching the realistic Re, Ro and Bu ranges. Clearly, one of the most effective approaches to extend the Ro range is to increase channel hydraulic diameter, as Ro is proportional to d2. As the laboratory heat transfer test at realistic N is extremely difficult, the coolant pressure, P, is technically easier to be raised for extending Ro range; even if Ro is only proportional to P. Based on this theoretical background, the design philosophy of the present experimental method is to increase Ro by pressurizing the rotating test channel using the maximum channel hydraulic diameter allowed to fit into the rotating rig. Having increased the Ro range, the range of Bu is accordingly extended as Bu is proportional to Ro2. In Figure 1, the laboratory test conditions adopted to generate the heat transfer data of rotating channels are also included3,4,5,6,7,8,9,10,11,12,13,14,15,16,17,18,19,20,21,22,23,24,25,26,27,28,29. As indicated in Figure 1, the coverage of realistic engine conditions by the available heat transfer data is still limited, especially for the required Bu range. The open and the colored solid symbols depicted in Figure 1 are the pointed and full-field heat transfer experiments, respectively. As collected in Figure 1, most of the heat transfer data with cooling applications to gas turbine rotor blades1,2,3,4,5,6,7,8,9,10,11,12,13,14,15,16,17,18,20,21,22,23,24,25,26 are point measurements using the thermocouple method. The wall conduction effects on measuring the wall conductive heat flux and the temperatures at fluid-wall interfaces undermine the quality of heat transfer data converted from the thermocouple measurements. Also, the heat transfer measurements1,2,3,4,5,6,7,8,9,10,11,12,13,14,15,16,17,18,20,21,22,23,24,25,26 using the thermocouple method cannot detect the two-dimensional heat transfer variations over a rotating surface. With the present experimental method29,30,31,32, the detection of full-field Nusselt number distributions over the rotating channel wall is permissible. The minimization of wall conduction effect using 0.1 mm thick stainless-steel foils with Biot numbers >>1 to generate the heating power by the present experimental method permits the one-dimensional heat conduction from the heating foil to the coolant flow. In particular, the acquisition of full-field heat transfer data involving both Ro and Bu effects is not permissible using the transient liquid crystal technique and the thermocouple method. With the current steady-state liquid crystal thermography method19, the detectable temperature range of 35-55 °C disables the generation of heat transfer data with realistic density ratios.
Using the flow parameters governing the heat convection in a rotating channel to demonstrate that the full coverage of realistic engine conditions seen in Figure 1 has not yet been achieved, so the need for acquiring the full-field heat transfer data at realistic engine conditions has been continuously urged. The present experimental method enables the generation of full-field heat transfer with both Coriolis-force and rotating-buoyancy effects detected. The protocols are aimed at assisting the investigators to devise an experimental strategy relevant to the realistic full-field heat transfer measurement of a rotating channel. Along with the method of parametric analysis that is unique to the present experimental method, the generation of heat transfer correlation for assessing the isolated and interdependent Ro and Bu effects on Nu is permitted.
The article illustrates an experimental method aimed at generating the two-dimensional heat transfer data of a rotating channel with flow conditions similar to the realistic gas turbine engine conditions but operating at much lower rotating speeds in the laboratories. The method developed to select the rotating speed, the hydraulic diameter of test channel and the range of wall-to-fluid temperature differences for acquiring the heat transfer data at realistic engine conditions is illustrated in the introduction. The calibration tests for the infrared thermography system, the heat loss calibration tests and the operation of the rotating heat transfer test rig are shown. The factors causing the significant uncertainties for heat transfer measurements and the procedures for decoupling the Coriolis-force and buoyancy effects on the heat transfer properties of a rotating channel are described in the article with the selective results to demonstrate the present experimental method.
NOTE: The details of rotating test facilities, data acquisition, data processing and the heat transfer test module emulating an internal cooling channel of a gas turbine rotor blade are in our previous works29,30,31,32.
1. Preparation of Heat Transfer Tests
2. Determination of Thermal Emissivity Coefficient for Infrared Thermography System
3. Dynamic Balance of Rotating Rig
4. Evaluation of Heat Loss Coefficients
5. Baseline Heat Transfer Tests
6. Rotating Heat Transfer Tests
7. Parametric Analysis
Realistic operating conditions for the internal coolant flows inside a rotating gas turbine blade in terms of Re, Ro and Bu are compared with the emulated laboratory conditions in Figure 1. The data points fall in the realistic engine conditions using the present experimental method summarized in the protocols11,14,17,20,21. Although the full-field heat transfer data are more useful than the pointed heat transfer data measured from the rotating channels, most of the previous heat transfer experiments adopt the thermocouple method (Figure 1). The present infrared thermography method detects the full-field heat transfer information from a rotating surface with the buoyancy-induced flows fully developed. With the free or forced convective external flows for a static or rotating test channel, the present protocols include the generation of heat loss correlations for post data processing (Figure 2). At the top of Figure 2, the construction of the heat transfer test module is also demonstrated. The correlative coefficients for all the fitted lines shown by Figure 2 fall between 0.95-0.98. In view of the hloss correlation seen in the plot of hloss against N de Figure 2, the error bars indicate the data range determined at each rotating speed.
Figure 3, Figure 4, and Figure 5 depict the selective heat transfer results measured from the static two-pass S-channel with longitudinal wavy ribs, the rotating two-pass S-channel31 and the rotating furrowed32 and pin-fin channel33. The estimated maximum uncertainties of the Nu measurements for the static S-ribbed channel, the rotating S-channel31, furrowed channel32 and pin-fin channel33 are 7.9%, 8.8%, 9.2%, and 9.7%, respectively. To disclose the Re impact on the heat transfer properties of a coolant channel, the base-line full-field heat transfer data detected from the static channel by the present infrared thermography method as typified by Figure 3 are essential. The diagram shown at the top of Figure 3 also depicts the channel configuration of the two-pass S-channel with the longitudinal wavy ribs. The channel section is square with the semi-circular sectioned longitudinal wavy ribs on two opposite heated walls of the inlet and outlet legs.
The applicability of isolated Re impact from Ro and Bu effects on local and regionally averaged heat transfer is permitted by presenting the heat transfer data in terms of Nu/Nu0 (Figure 4). Both patterns and levels of Nu/Nu0 at the same Ro with similar Bu seem to be weak functions of Re (Figure 4). The typical results from the protocol for disclosing the isolated Coriolis force effects on heat transfer properties are demonstrated in Figure 5. In Figure 5, the variations of Nu/Nu0 at each fixed Ro against Bu for two different rotating channels with wavy endwalls32 and diamond shaped pin-fins33 tend to follow linear-like data trends. Thus, the linear extrapolation when Bu→0 is selected for the identified Nu/Nu0 levels at Bu = 0 and Ro>0. But, due to the different channel configurations, the Nu/Nu0 ratios measured from the rotating furrowed32 and pin-fin33 channels as depicted in Figure 5 are respectively decreased and increased by raising Bu. In this regard, the depiction of Nu/Nu0 variations against density ratio (Δρ/ρ)3,4,5,6,34 has often led to the non-linear Nu/Nu0 variations. Thus, the extrapolation of each Nu/Nu0 data trend at a fixed Ro toward the asymptotic limit of Δρ/ρ→0 with diminished buoyancy effect along a non-linear data trend is often affected by the type of correlative function selected. Nevertheless, the data extrapolating procedure for the heat transfer results detected from the leading and trailing walls of the rotating channels32 demonstrates the applicability to unravel the isolated Coriolis force effects on heat transfer properties with vanished buoyancy interaction at Bu=0 (Figure 5).
The so-called zero-buoyancy Nu/Nu0 ratios are only controlled by Ro to reflect the isolated Coriolis force effects. The manner of heat transfer variations from the static-channel references disclosed by steps 7.7 and 7.8 is typified by Figure 6. The separated Ro impact from the buoyancy effect on the heat transfer performances of a rotating channel is correlated as the Ro function to be a part of Nu/Nu0 correlation (Figure 6). The positive or negative ψ2 values in Figure 6 indicate the improving or impeding effects on heat transfer performances due to buoyancy interactions. The larger ψ2 magnitude, the higher degrees of rotating buoyancy impact are imposed on the heat transfer properties. The fitted lines indicated in Figure 6 are the plots of the correlative functions. The functional structures of the correlations for zero-buoyancy Nu/Nu0 ratios and ψ2 values are generally determined in accordance with the varying manners of the data trends emerged in Figure 6. As discussed previously, the different channel geometries between the furrowed32 and pin-fin33 channels have respectively led to the negative and positive ψ2 values in Figure 6. But the common feature of the reduced magnitudes of ψ2 values caused by increasing Ro is observed for the two types of rotating channels32,33 de Figure 6. Having correlated the ψ2 values and the Nu/Nu0 ratios at zero-buoyancy conditions into the Ro functions, the heat transfer correlations, which permit the evaluation of the isolated and coupled Ro and Bu effects on Nu/Nu0, is generated for the particular rotating channel.
Figure 1. Realistic operating Re, Ro and Bu ranges and the emulated laboratory conditions for a rotating coolant channel in a gas turbine rotor blade. The test conditions performed by NASA HOST program3,4,5,6 are indicated as the bar symbol. The open and solid symbols respectively signify the Bu, Ro, and Re test ranges for the pointed and full-field heat transfer measurements. Numbers in brackets are references from which data are taken. Please click here to view a larger version of this figure.
Figure 2. Typical heat loss coefficients (hloss) at various rotating speeds30 using the trapezoidal twin-pass rib-roughened rotating channel as an illustrative example. The diagram at the top depicts the constructional details of the rotating test module. The slope of each data trend constituted by the heat loss flux against the wall-to-ambient temperature difference shown in the left lower portion reveals the heat loss coefficient at the specific rotating speed. By correlating the heat loss coefficients detected at all the rotating speed tested, the generated heat loss correlation typified by the right lower plot is incorporated into the data processing program for Nu accountancy. The error bars in the lower right plot indicate the ranges of hloss30. Please click here to view a larger version of this figure.
Figure 3. Local Nusselt number distribution of the static twin-pass S-channel roughened by curly ribs at Re = 15,000 measured by present infrared thermography method. The top diagram depicts the endwall of the two-pass wavy channel and the longitudinal S-ribs. As indicated by the AA’ section view, the pair of longitudinal S-ribs is arranged inline on two opposite channel endwalls. In the detailed distribution of Nusselt number over the two-pass wavy endwall shown as the lower plot, the Nu data along the two longitudinal S-ribs are discarded due to the wall conduction effects on the distributions of heat-flux and wall-temperature. Please click here to view a larger version of this figure.
Figure 4. Examples demonstrating the isolation of Re impact from Ro and Bu effect on local and regionally-averaged heat transfer properties of rotating channel. The upper portion exhibits the detailed Nusselt number distributions at a fixed Ro of 0.15 with a different Re of 5000, 7500, and 12,500 to enlighten the impacts of Reynolds number on the heat transfer properties of the rotating endwall. The lower portion depicted the area-averaged heat transfer properties over the rotational leading and trailing endwalls. The normalized Nu/Nu0 ratios highlight the heat transfer variations from the non-rotating scenarios by rotation. Adapted with permission from Chang et al. 201731. Please click here to view a larger version of this figure.
Figure 5. Examples demonstrating the uncoupled Ro effect from Bu impact on heat transfer properties of rotating channel32,33. Each Bu-driven Nu/Nu0 variation is obtained at the fixed Ro and correlated as a linear function of Bu as indicated by the straight line in each plot. The correlation coefficients of these fitted lines fall between 0.96 and 0.98. The extrapolation of the Nu/Nu0 data trend toward Bu→0 along each fitted line reveals the Nu/Nu0 ratio at the tested Ro. The magnitude and slope of each Bu-driven Nu/Nu0 data trend disclose the manners of buoyancy effect on heat transfer performances. The magnitudes of the slopes represent the degrees of Bu impact on Nu/Nu0. The positive and negative slopes respectively reflect the improving and impairing buoyancy impact on heat transfer levels. Numbers in brackets are references from which data are taken. Please click here to view a larger version of this figure.
Figure 6. Uncoupled Ro and Bu effects on regionally averaged heat transfer performances of the rotating wavy channel32,33. The upper portion collects the heat transfer scenarios at various Ro but with vanished buoyancy effect at Bu = 0. Such Nu/Nu0 variations are solely caused by the various Coriolis forces at different Ro. The lower portion shows the variations of Bu impact on Nu/Nu0 at different Ro. The negative and positive ψ2 values indicate the respective impairing and improving Bu impacts on the heat transfer performances for the furrowed32 and pin-fin33 channels. The dotted lines in this Figure are the correlation results for Nu/Nu0 at Bu = 0. Numbers in brackets are references from which data are taken. Please click here to view a larger version of this figure.
While the endwall temperatures of a rotating channel are detected by an infrared thermography system, the fluid temperatures are measured by thermocouples. As the alternative magnetic field of an AC motor that drives a rotating rig induces electrical potential to interfere the thermocouple measurements, the DC motor must be adopted to drive a rotating test rig.
The fluid temperature distribution over the exit plane of a heated channel is not uniform. At least five thermocouples on the existing plane of a rotating channel are recommended for measuring the local fluid exit temperatures. In particular, these thermocouples measuring the fluid temperatures installed in the flow passage are subject to centrifugal forces during the rotating tests. The thermocouple wires are easily bent toward the hot channel walls. Thus, a shielded thermocouple cable for measuring the fluid entry temperature is used. On the flow exit plane, a mesh with several thermocouple beads weaved on the mesh can be sandwiched between the exit flanges of a test channel to detect the fluid exit temperatures at the predefined locations under a rotating test condition.
With considerable rotation induced buoyancy effects on the flow and heat transfer characteristics of a rotating channel, the method selected to detect the full-field heat transfer data needs to include both Coriolis-force and buoyancy effects. Using the transient liquid crystal method for measuring the full-field heat transfer data, the thermal boundary layers are not yet fully developed as the temporal channel-wall temperature variations are essential by this method for acquiring the convective heat transfer coefficients. As the centripetal acceleration could reach 105 x g in a coolant channel of a rotating gas turbine blade, the heat transfer data subject to the influences of the fully developed buoyancy flows, which are detectable by the present experimental method, are more practical for design activities.
The exposure of the scanned hot channel wall to an infrared camera inevitably incurs heat loss from the Joule heat generated by the heating foils. The protocols for conducting the heat loss calibration tests are critical for ensuring the quality of heat transfer data. Inheriting either from the free or forced convective external flows for a static or rotating test channel, the convective heat transfer coefficients can be correlated as the function of wall-to-ambient temperature difference at a fixed rotating speed (Figure 2). It is preferable to envelop the entire rotating heat transfer test module with a shield for recovering the "free-convective" like external flows during the rotating tests. The maximum experimental uncertainties of heat transfer data are generally reduced when the percentage of the heat loss flux from the supplied heat flux is reduced. Nevertheless, the heat loss coefficients are slightly increased as N increases even with the enveloped shield covering the entire heat transfer test module (Figure 3). The heat loss correlation is included in the post data processing program to evaluate the distribution of local heat loss flux for each set of heat transfer test results. As the thermal inertia of the heat transfer module filled by thermal insulation material is considerably increased, the time required for reaching the steady-state condition during each heat loss test is considerably extended from a heat transfer test with airflow.
It is essential to investigate the applicability of the isolating Re effect on heat transfer properties from those induced by rotation. As the Re effect on heat transfer performances depends on the channel configurations, it is not appropriate to customarily adopt the heat transfer correlations generated from other channel geometries as the static-channel heat transfer references. The present experimental method isolates Re impact from Ro and Bu effects by presenting the heat transfer data in terms of Nu/Nu0, in which the Nu0 data are measured for the static test channel. While the buoyancy effect in a rotation channel with centripetal acceleration about 105 x g is considerable, the gravitation-driven buoyancy effect on the heat transfer property of a static channel is generally negligible within the typical range of fluid density ratios examined for a static test channel.
During a heat transfer test after feeding heater power to generate the required temperature gradients for facilitating heat convection, a certain degree of buoyancy effect driven by the induced centripetal acceleration field in the rotating channel is inevitable. Such coupled Ro and Bu effects for a rotating channel at the realistic engine conditions are not negligible due to the extremely high centripetal accelerations. Thus, both Coriolis force and rotating buoyancy level are simultaneously altered when the rotating speed is adjusted. The simultaneous control of Ro and Re at the targeting values during the rotating experiment is essential for decoupling the Ro and Bu effects on heat transfer properties. Having fixed both Ro and Re, the heat transfer variations corresponding to the variation of heat flux, or buoyancy level, reflect the rotating buoyancy effect on heat transfer properties at the tested Ro. The Nu/Nu0 data converted from the data set generated in this manner permit the implementation of steps 7.4 – 7.8 for identifying the Coriolis force effect and rotating buoyance effect in isolation.
The Bu impact on the heat transfer property of a rotating channel is often Ro dependent as exemplified by Figure 6 in which the ψ2 values are varied as Ro changes. It is not appropriate to select the mathematic structure of the heat transfer correlation that treats the Ro and Bu as the independent parameters in the correlation.
In view of the Nu/Nu0 extrapolation toward the limiting condition of Bu→0, the linear-like Nu/Nu0 variations against the selected buoyancy parameter is preferable in order to reduce the uncertainty caused by the data extrapolation. In this regard, the fluid density ratio, Δρ/ρ or the buoyancy number, Bu, is recommended as the buoyancy parameter for disclosing the zero-buoyancy Nu/Nu0 level during such data extrapolating process.
With high pressure rotating tests, the deformations of heating foils and the constituent components of a rotating channel due to the thermal expansions at various patterns of temperature distribution often cause airflow leakage during the rotating test. Such small airflow leakage is difficult to be identified during the rotating test. Thus, immediate subsequent data processing is recommended for acquiring the heat transfer data of the rotating channel. By cross-examining the heat transfer results obtained from the previous rotating tests, the implication of any inconsistent data trend is the possible airflow leakage. The subsequent measures to detect and then prevent the airflow leakage are required.
We have demonstrated a method for generating the heat transfer data of a rotating channel at the realistic engine conditions with the Coriolis-force effect and rotating buoyancy effect uncoupled. The major limitation of the present experimental method for extending the test ranges of Ro and Bu is the sustainability of the infrared camera that rotates with the test channel. In general, 10 x g is the maximum sustainable centrifugal acceleration for an infrared camera. With respect to the existing method detecting the heat transfer rates of a rotating channel, the use of thin heating foil can minimize the effects of channel-wall conduction on the distribution of local convective heat flux and the detection of temperatures at wall-fluid interfaces. Also, the two-dimensional full-field heat transfer distribution over a rotating surface subject to the steady-state buoyancy effect are detectable using the present experimental technique. With the data analysis method developed, the influences of Coriolis force and rotating buoyancy on the full-field heat transfer property of a rotating channel can be uncoupled. This method has already been applied to a wide range of rotating channel configurations. We expect that the present experimental strategy can lead to the design- friendly heat transfer correlations and which will continue to extend for the full coverage of realistic engine conditions when the advancement of infrared camera technology permits its usages at the conditions with higher centrifugal accelerations.
The authors have nothing to disclose.
The present research work was financially sponsored by the Ministry of Science and Technology of Taiwan under the grant NSC 94-2611-E-022-001, NSC 95-2221-E-022-018, NSC 96-2221-E-022-015MY3 and NSC 97-2221-E-022-013-MY3.
Rotating test rig | In-house made | Design by this research group | |
Heat transfer test module | In-house made | Design by this research group | |
Mass flow meter | Eldride Product, Inc. | 3100301-01-01 359-1007 |
|
Infrared thermography system | NEC P384A-8 | 3100401-04 3127A-4 |
|
Instrumentation slip ring | Michigan Scientific SR36M | 3100506-62 3553-372 |