Presented here is a protocol for extraction of ramie fiber in alkali hydrogen peroxide system supported by controlled-release alkali source.
This protocol demonstrates a method for ramie fiber extraction by scouring raw ramie in an alkali hydrogen peroxide system supported by a controlled-release alkali source. The fiber extracted from ramie is a type of textile material of great importance. In previous studies, ramie fiber was extracted in an alkali hydrogen peroxide system supported only by sodium hydroxide.However, due to the strong alkalinity of sodium hydroxide, the oxidation reaction speed of hydrogen peroxide was difficult to control and thus resulted in great damage to the treated fiber. In this protocol, a controlled-release alkali source, which is composed of sodium hydroxide and magnesium hydroxide, is used to provide an alkali condition and buffer the pH value of the alkali hydrogen peroxidesystem. The substitution rate of magnesium hydroxide can adjust the pH value of the hydrogen peroxide system and has great influence on the fiber properties. The pH value and oxidation-reduction potential (ORP) value, which represents the oxidation ability of alkali hydrogen peroxide system, were monitored using a pH meter and ORP meter, respectively. The residual hydrogen peroxide content in the alkali hydrogen peroxide system during the extraction process and the chemical oxygen demand (COD) value of wastewater after fiber extraction are tested by KMnO4 titration method. The yield of fiber is measured using a precision electronic balance, and residual gums of fiber are tested by a chemical analysis method. The polymerization degree (PD value) of fiber is tested by an intrinsic viscosity method using the Ubbelohde viscometer. The tensile property of fiber, including tenacity, elongation, and rupture, is measured using a fiber strength instrument. Fourier transform infrared spectroscopy and X-ray diffraction are used to characterize the functional groups and crystal property of fiber. This protocol proves that the controlled-release alkali source can improve the properties of the fiber extracted in an alkali hydrogen peroxide system.
Ramie, commonly known as 'China grass' is a perennial herb whose fiber can be used as an excellent material for the textile industry1,2. It is one of the main economic crops native to China; the production of ramie in China has accounted for more than 90% of the total yield in the world1,2. Ramie fiber is one of the strongest and longest plant fibers, lustrous with an almost silky appearance3,4. The long length of ramie fiber make it suitable for single fiber spinning, which is seldom seen in bast fiber. The textile made from ramie fiber possesses many excellent properties, such as coolness, antibacterial, excellent thermal conductivity, ventilation, etc.3,4
Cellulose is the main component of ramie fibers, and the other components in ramie, such as pectin, lignin, water soluble materials, are defined as gums5,6. Ramie fiber can be extracted by dissolving the gums in solution containing chemical reagents, in a process defined as degumming5,6. Mainly two approaches of ramie fiber extraction exist: chemical degumming and bio-degumming. The energy consumption, time consumption, and COD value of degumming wastewater in traditional chemical degumming is rather high, as cellulose fiber is extracted by scouring raw ramie in concentrated NaOH under high pressure for 6 to 8 h7,8. Alternatively, bio-degumming is an eco-friendly option for ramie fiber extraction. Nevertheless, the harsh reaction condition and sophisticated equipment inhibit its further industrial application9,10. Therefore, oxidation degumming with alkali hydrogen peroxide presents a valuable and alternative application to focus on, for it requires shorter degumming time and lower degumming temperature11,12. However, due to the strong oxidation ability of the peroxides, substantial cellulose degradation may occur during the degumming process, which can cause great damage to fiber properties13,14. This is the biggest drawback of alkali peroxide oxidation degumming of ramie.
In previous studies, ramie fiber was extracted in an alkali hydrogen peroxide system supported only by sodium hydroxide15. However, due to the strong alkalinity of sodium hydroxide, the oxidation reaction speed of hydrogen peroxide was difficult to control and thus resulted in great damage to the treated fiber7. To improve the properties of ramie fiber, a controlled-release alkali source, which is composed of sodium hydroxide and magnesium hydroxide, is used in this study to offer an alkali condition and buffer the pH value of alkali hydrogen peroxide system16,17.
The rationale behind this technology can be described as follows. Magnesium hydroxide is slightly soluble in distilled water, and it can dissolve gradually into the degumming solution with the consumption of OH– and keep the pH value and thus oxidation ability of degumming solution in an appropriate range18. The substitution rate (SR) of magnesium hydroxide is defined as the mole proportion of NaOH replaced by magnesium hydroxide under the total alkali dosage of 10%, and the substitution rate can be calculated by the following equation. Moreover, Mg2+ can prevent cellulose degradation caused by over oxidation19,20.
Here, M2 (g) is the weight of Mg(OH)2, M1 (g) is the weight of NaOH, 40 is the molecular weight of NaOH, 58 is the molecular weight of Mg(OH)2, 2 is the number of OHs in Mg(OH)2, and SR is the substitution rate.
The technology of this protocol can be extended to the extracting, bleaching, and modifying of plant materials in an alkali hydrogen peroxide system. However, it must be noted that the selection of pH value and reaction temperature of the alkali hydrogen peroxide system is key for this technology21. The pH value of the alkali hydrogen peroxide system can be adjusted by changing the substitution rate17. The pH value and thus oxidation ability of the alkali hydrogen peroxide system decrease with the increasing of substitution rate. When the reaction temperature is set at 85 °C, the free radical reaction plays the main role in the system and the strong oxidation of the system is suitable for dissolving materials; when the reaction temperature is set at 125 °C, the free radical reaction is inhibited and a large amount of HOO exists in the system, which makes the system suitable for bleaching19.
1. Oxidation Degumming of Ramie
2. Testing of the Degumming Solution Property
3. Testing the Ramie Fiber Property
The solubility of Mg(OH)2 in distilled water and degumming solution was studied (Figure 1). The effect of Mg(OH)2 substitution rate on pH value and ORP value (Figure 2) of the degumming solution was tested. The degumming yield and residual gums of fiber degummed under various Mg(OH)2 substitution rate were calculated (Figure 3). DP value, crystallinity, tensile properties of fiber (Figure 4), and COD value of wastewater (Figure 5) were used to evaluate the effect of Mg(OH)2 on degumming. The FTIR pattern of fiber was obtained (Figure 6). The residual H2O2 content of the degumming solution during the fiber extraction process was tested (Figure 7) and the effect of the degumming temperature in the second stage is shown in Table 1. The comparison of oxidation degumming (using sustainable alkali source and NaOH) and traditional degumming is shown in Table 2.
Although the solubility of Mg(OH)2 in degumming solution was higher than that in distilled water due to the slat effect of degumming auxiliaries, it was still insufficiently soluble, and thus a controlled-released property was applied (Figure 1). When a controlled-released alkali source was used, the pH value of the degumming solution was stable and decreased with the rising of substitution rate (Figure 2A). The decreasing of the ORP value was slower under higher substitution rate (Figure 2B). Residual gum analysis revealed that the yield of degumming and residual gums of fiber increased with the substitution rate; the substitution rate should be above 60% to prevent fiber adhesion. (Figure 3). The DP value, crystallinity, and tensile properties of fiber increased with the substitution rate from 0% to 20%, but decreased upon further rising of the substitution rate (Figure 4): this is explained by the excessive amount of gums that were retained in the fiber when the substitution rate was over 20%. When the substitution rate was set at 20%, the pH value of the degumming solution was 11.8; and the tenacity, elongation, rupture, DP value, and hemicellulose content yield of fiber increased by 39.82%, 12.13%, 46.15%, 14.89%, and 5%, respectively (Figure 2, Figure 3, Figure 4). Moreover, the COD value of the degumming waste water decreased by 20% (Figure 5). In FTIR patterns of the fiber, the signals in the region of 3,400-2,800 cm-1 and the peak at 2,900 cm-1 were due to the stretching vibration of -CH and -OH in cellulose, and these signals existed in all samples. The carbonyl peak at 1,730-1,750 cm-1 was attributed to the C=O stretching of C-OH bending in hemicellulose, and this signal was stronger when the substitution rate was lower, which indicated that hemicellulose can be removed more effectively under a lower substitution rate (Figure 6). Residual H2O2 contents increased by 3 g/L when using the controlled-released alkali source; however, the substitution rate did not influence the residual H2O2 content (Figure 7). When the controlled-release alkali source was used for degumming, the decomposition speed of H2O2 was controlled by the degumming temperature. In the initial period of degumming (0 to 60 min), cellulose degradation seldom occurred, for it was covered by gums. Therefore, a large amount of free radicals was needed and the temperature should be set at 85 °C. After 60 min, most of the gums were removed and the cellulose was exposed to the degumming solution: the temperature should be raised to 125 °C to slow down the free radical reaction speed and therefore prevent the degradation of cellulose (Table 1). The comparison of oxidation degumming (using a sustainable alkali source and NaOH) and traditional degumming revealed that fiber degummed in alkali hydrogen peroxide system supported by controlled-release alkali source achieved the best properties (Table 2).
Figure 1. The solubility of Mg(OH)2 in distilled water and degumming solution19. Mg(OH)2 showed higher solubility in degumming solution compared with that in distilled water, because of the salt effect of degumming auxiliaries. Mg(OH)2 dissolves into the degumming solution slowly according to the inset chemical equations. Please click here to view a larger version of this figure.
Figure 2. The effect of Mg(OH)2 substitution rate on degumming solution properties. (A) The pH value of degumming solution. When Mg(OH)2 was used, the pH value of the degumming solution was stable and decreased with the rising of substitution rate. (B) The ORP value of degumming solution19. The decreasing speed of ORP value was slower under higher SR value. SR = substitution rate. Please click here to view a larger version of this figure.
Figure 3. The effect of Mg(OH)2 substitution rate on degumming yield and residual gums of fiber. The inset image shows the topographies of ramie fiber degummed under Mg(OH)2 substitution rates of: (a) 0%, (b) 20%, (c) 40%, (d) 60%, (e) 80%, (f) 100%19. The yield of degumming and residual gums of fiber increased with substitution rate and substitution rate should be above 60% to prevent fiber adhesion. Please click here to view a larger version of this figure.
Figure 4. The effect of Mg(OH)2 substitution rate on: (A) the DP value and crystallinity of fiber; and (B) the tensile properties of fiber19. DP value, crystallinity, and tensile properties of fiber increased with SR from 0% to 20%, but decreased with further rising of substitution rate. Error bars represent the standard deviation of data from 30 duplicate tests. Please click here to view a larger version of this figure.
Figure 5. The effect of Mg(OH)2 substitution rate on COD value of degumming wastewater19. The COD value of degumming wastewater decreased with the rising of substitution rate. Error bars represent the standard deviation of data from 30 duplicate tests. Please click here to view a larger version of this figure.
Figure 6. FTIR of fiber degummed with various substitution rates of Mg(OH)219. The signals in the region of 3,400-2,800 cm-1 and the peak at 2,900 cm-1 were due to the stretching vibration of -CH and -OH in cellulose; these signals were present in all samples. The carbonyl peak at 1,730-1,750 cm-1 was attributed to the C=O stretching of C-OH bending in hemicellulose; these signals were stronger when SR was lower, which indicated that hemicellulose can be removed more effectively under lower substitution rate. Please click here to view a larger version of this figure.
Figure 7. Residual H2O2 contents in degumming solution with various substitution rate of Mg(OH)219. Residual H2O2 contents increased when the controlled-released alkali source was used; however, the substitution rate did not have influence on the residual H2O2 content. SR = substitution rate. Please click here to view a larger version of this figure.
Temperature | Linear density (dtex) | Tenacity (cN/dtex) | Elongation (%) | Rupture (cN/dtex) |
100 °C | 6.1 | 6.69 | 2.33 | 0.08 |
125 °C | 5.6 | 8.3 | 2.75 | 0.14 |
Table 1. Tensile properties of fiber scouring under various temperature in the second stage19. The fiber exhibited better tensile properties under higher scouring temperature.
Oxidation degumming | Traditional degumming | ||
SR 20% | SR 0% | ||
Yield (%) | 74.2 | 72.34 | 65 |
Tenacity (cN/dtex) | 10.12 | 6.09 | 7.8 |
Elongation (%) | 2.72 | 2.39 | 2.43 |
Rupture (cN/dtex) | 0.13 | 0.07 | 0.1 |
PD value | 1980 | 1685 | 1732 |
COD value (mg/L) | 23000 | 29000 | 29800 |
Table 2. Comparison of oxidation degumming. Comparison of oxidation degumming (using sustainable alkali source and NaOH) and traditional degumming19 ramie fiber. Fiber degummed in an alkali hydrogen peroxide system supported by a controlled-release alkali source achieved the best properties. SR = substitution rate.
The setting of Mg(OH)2 substitution rate and reaction temperature was the key point of this protocol. Mg(OH)2 substitution rate can influence the pH value and thus oxidation ability of degumming solution. The best Mg(OH)2 substitution rate for ramie degumming was 20%, because cellulose cannot receive enough protection under a substitution rate below 20%, and an excessive amount of residual gums (low DP value and crystallinity) would be retained in fiber under a substitution rate above 20% (Figure 4A).
The reaction temperature can influence the reaction pathway of hydrogen peroxide. There were two parallel reactions in the oxidation degumming of ramie: the first was the reaction between H2O2 and gums; the second was the reaction of H2O2 and cellulose, which can cause damage to cellulose and thus decrease the tensile properties of degummed fiber. The rise of temperature can induce the acceleration of the two reactions (the reaction speed increased by 2 or 4 times, with temperature rise per 10 °C). The growth of the reaction speed for H2O2 and gums was much higher than H2O2 and cellulose, because its activation energy is higher, which made it more sensitive to temperature change. In the initial period of degumming (0 to 60 min), cellulose degradation seldom occurred, because it was covered by gums. Therefore, a large amount of free radicals was needed and the temperature should be set at 85 °C. After 60 min, most of gums were removed and the cellulose was exposed to the degumming solution; the temperature should be raised to 125 °C to slow down the free radical reaction speed and therefore prevent the degradation of cellulose (Table 1).
The technology of this protocol can be extended to other areas, such as the extracting, bleaching, and modifying of plant material in alkali hydrogen peroxide system. The Mg(OH)2 substitution rate and reaction temperature should be set according to the specific conditions. Normally, the pH value and thus oxidation ability of alkali hydrogen peroxide system decreases with the increasing of substitution rate. When the reaction temperature is set at 85°C, the free radical reaction plays the main role in the system and the strong oxidation ability makes the system suitable for dissolving materials; when the reaction temperature was set at 125 °C, the free radical reaction was inhibited and a large amount of HOO existed in the system, which makes the system suitable for bleaching19. The limitation of this technology is that the pH value of hydrogen peroxide system can only be set at values between 10.0 to 12.0 when the controlled-released alkali source is used.
We have demonstrated a method of improving the property of oxidation degummed ramie fiber by using Mg(OH)2 as the sustainable alkali resource (Table 2). This technology is now being applied in the pilot stage, and we expect that this technology will continue to develop.
The authors have nothing to disclose.
This work was supported by the earmarked fund for China Agriculture Research System for Bast and Leaf Fiber Crops (grant number CARS-19), The China Academy of Agricultural Science and Technology Innovation Project (grant number ASTIP-IBFC07), The innovation fund for graduate students in Donghua University (grant number 16D310107), The 'Xiaoping science and technology innovation team' (industrialization integrated R & D group of bast fiber biological degumming), China Scholarship Council.
Hydrogen peroxide, 30% | Fisher Scientific | H325-100 | Chemical for degumming |
Magnesium hydroxide, 99% | Fisher Scientific | AA1236722 | Chemical for degumming |
Sodium hydroxide | Fisher Scientific | S318-1 | Chemical for degumming |
Sodium bisulfite | Fisher Scientific | S654-500 | Chemical for degumming |
Sodium tripolyphosphate | Fisher Scientific | AC218675000 | Chemical for degumming |
Anthraquinone, >98% | Fisher Scientific | AC104930500 | Chemical for degumming |
1-Hydroxy Ethylidene-1,1-Diphosphonic Acid | Fisher Scientific | 50-901-10243 | Chemical for degumming |
Degumming oil | Minglong auxiliaries limited liability company, Yiyang, Hunan,China | —— | Chemical for degumming |
Ethyl alcohol | Fisher Scientific | A962-4 | Chemical for testing |
Benzene | Fisher Scientific | AA43817AE | Chemical for testing |
Copper wire,0.5mm (0.02in) dia | Fisher Scientific | AA10783H4 | Chemical for testing |
Cupriethylenediamine solution 1mol/L | Fisher Scientific | 24991 | Chemical for testing, caution toxic |
Nitric acid (65% ~68% ) | Fisher Scientific | A200-612GAL | Chemical for testing, caution |
Ethylenediamine | Fisher Scientific | AC118420100 | Chemical for testing |
Potassium permanganate | Fisher Scientific | P279-500 | Chemical for testing |
Sulphuric acid | Fisher Scientific | A300C-212 | Chemical for testing |
Silver sulfate | Fisher Scientific | S190-25 | Chemical for testing |
Raw ramie | Guangyuan limited liability company, Changde, Hunan,China | —— | Raw materials |
Electric-heated thermostatic water bath | Senxin Experiment equipment limited liability company,Shanghai,China | DK-S28 | Equipments for degumming |
High temperature lbaorator dyeing machine | Shanghai Longda chemcials Crop. | RY-1261 | Equipments for degumming |
Thermometer | Sichuan Shubo (group)Co.,Ltd | 100 °C | Equipments for degumming |
Vacuum suction machine | Yukang KNET ,Shanghai,China | SHB-IIIA | Equipments for testing Mg(OH)2 solublity |
Suction flask | Sichuan Shubo (group)Co.,Ltd | 1000mL | Equipments for testing Mg(OH)2 solublity |
Sand-core funnels | Sichuan Shubo (group)Co.,Ltd | 35mL | Equipments for testing Mg(OH)2 solublity |
Oxidation reduction potential meter | Dapu instrument, Shanghai, China | MODEL 421 | Equipments for testing ORP value |
pH meter | Hanna instruments,Beijing,China | HI 98129 | Equipments for testing pH value |
Acid burette | Sichuan Shubo (group)Co.,Ltd | 50mL | Equipments for testing H2O2 content |
Flask | Sichuan Shubo (group)Co.,Ltd | 250mL/500mL | Equipments for testing H2O2 content; residual gums content |
Electric furnace | Jiangyi Experiment instruments limited liability company,Shanghai,China | 800-2000W | Equipments for testing residual gums content |
Reflux condensing tube | Sichuan Shubo (group)Co.,Ltd | 250mL | Equipments for testing residual gums content; COD value |
Fiber cutter (40mm) | Changzhou No.2 Textile Machine Co.,Ltd | Y171A | Equipments for testing fiber density |
Ostwald viscometer | Taizhou, jiaojiang, glass instruments company | 0.6mm | Equipments for testing fiber PD value |
Spherical fat extractor | Sichuan Shubo (group)Co.,Ltd | 250mL | Equipments for testing fiber PD value |
Soxhlet extractor | Sichuan Shubo (group)Co.,Ltd | 250mL | Equipments for testing fiber PD value |
Torsion balance | Liangping instrucments Co.,Ltd,Shanghai, China | JN-B | Equipments for testing fiber density |
Fiber strength instrument | Xinxian instruments, shanghai,China | XQ-2 | Equipments for testing fiber tensile property |
Tension clamp | Depu textile technology Co.,Ltd, Changzhou, jiangsu, China | 0.3cN/dtex | Equipments for testing fiber tensile property |
COD thermostatic heater | Qiangdao Xuyu environment protection technology Lit company | DL-801A | Equipments for testing COD value |
FTIR | Thermo Fisher, America | Nicolet | FTIR analysis |
XRD | Rigaku, Japan | D/max-2550 PC | XRD analysis |
Electronic balance | Shanghai jingtian Electronic instrument Co.,Ltd | FA2004A | Generral equipments |
Drying oven | Tonglixinda instruments, Tianjin,China | 101-2AS | Generral equipments |
Weighing bottle | Sichuan Shubo (group)Co.,Ltd | 50×30 | Generral equipments |
Beaker | Sichuan Shubo (group)Co.,Ltd | 500mL | Generral equipments |
Sample sieve | Xiaojin hardware instruments Co.,Ltd, Shangyu, Zhejiang | 120 mesh | Generral equipments |
Glass rod | Sichuan Shubo (group)Co.,Ltd | —— | Generral equipments |
Cylinder | Sichuan Shubo (group)Co.,Ltd | 250mL, 50mL | Generral equipments |
Pipette | Sichuan Shubo (group)Co.,Ltd | 5mL, 10mL | Generral equipments |
Rubber suction bulb | Sichuan Shubo (group)Co.,Ltd | —— | Generral equipments |
Orign | OriginLab | 8.0 | Software for figure drawing |