Source: Paranjape, S. R., et al. Compartmentalization of Human Stem Cell-Derived Neurons within Pre-Assembled Plastic Microfluidic Chips. J. Vis. Exp. (2019)
The video demonstrates the differentiation of neural stem cells (NSCs) using a microfluidic device comprising a somatic and an axonal compartment separated by a microgroove barrier. NSCs are introduced into the somatic compartment and are allowed to adhere. The NSCs differentiate into neurons inside the somatic compartment and extend axons through the microgroove barrier to the axonal compartment.
NOTE: Figure 1A, B shows a schematic of the pre-assembled cyclic olefin copolymer (COC) chip, including the locations of the main channels or compartments, wells, and microgrooves. The compartmentalized chip can establish distinct fluidic microenvironments within a compartment as demonstrated by the isolation of food coloring dye (Figure 1C).
1. Coating of multi-compartment chips for hSC-neurons
NOTE: Figure 2A shows an overview of the coating procedures.
2. Seeding NSCs into the multicompartment chip
NOTE: This protocol used commercially purchased NSCs, unlike our previous publication which began with human embryonic stem cells. In this protocol neural stem cells are plated directly into the plastic chips where they differentiate into neurons. The cells can be allowed to proliferate as NSCs (without differentiation) for up to 2 passages and stored in vials in liquid N2 for further use. This protocol uses NSC vials stored in liquid N2 after passage 1 or 2. Figure 2B shows an overview of the coating procedures.
Figure 1: The pre-assembled COC, multicompartment microfluidic chip. (A) A drawing of the chip identifying the upper and lower wells. The size of the chip is 75 mm x 25 mm, the size of standard microscope slides. (B) A zoomed-in region showing the channels and microgrooves separating the channels. (C) This photograph illustrates the creation of isolated microenvironments within each compartment using food coloring dye.
Figure 2: Plastic compartmentalized chip coating and NSC cell plating timeline. (A) Plastic multicompartment chips were coated with a pre-coating solution, and then poly-L-ornithine and laminin before pre-conditioning with NSC media. (B) NSCs were plated with 7 x 104 cells in the somatic compartment of the chip. The cells were grown in NSC media for 24 h and then the media was replaced with neural differentiation media. Differentiated neurons were observed by 7-10 days post differentiation.
The authors have nothing to disclose.
complete neural stem cell media: | |||
REC HU EGF 10 UG BIOSOURCE (TM) |
ThermoFisher Scientific | PHG0314 | 20ng/mL |
REC HU FGF BASIC 10 UG BIOSOURCE (TM) |
ThermoFisher Scientific | PHG0024 | 20ng/mL |
GlutaMAX Supplement (100X) | ThermoFisher Scientific | 35050061 | 2mM |
KnockOut DMEM/F-12 | ThermoFisher Scientific | 12660012 | |
StemPro Neural Supplement | ThermoFisher Scientific | A1050801 | 2% |
Gibco DPBS without Calcium and Magnesium | ThermoFisher Scientific | 14190144 | |
GIBCO HUMAN NSC (H9) KIT COMBO KIT | Gibco | N7800200 | |
Gibco Laminin | ThermoFisher Scientific | 23017015 | |
Glass Pasteur pipettes | Sigma-Aldrich | CLS7095D5X SIGMA | 5.75 in length |
H9-DERIVED HU NEURAL STEM CELL 1E6 CELLS/VIAL; 1 ML |
ThermoFisher Scientific | 510088 | |
hibernate-E Medium | ThermoFisher Scientific | A1247601 | |
Incubator, 5% CO2 37 °C | |||
Mr. Frosty | ThermoFisher Scientific | 5100-0001 | |
Neural differentiation media | Per 100 mL. | ||
Antibiotic-Antimycotic (100x) | ThermoFisher Scientific | 15240112 | 1mL (100X) |
Ascorbic acid | Sigma Aldrich | A8960 | 200mM |
BDNF | ThermoFisher Scientific | PHC7074 | 40 ng/mL |
Gibco B27 Plus Supplement (50X) | FisherScientific | A3582801 | 2mL (50X) |
Gibco CultureOne Supplement (100X) | FisherScientific | A3320201 | 1mL (100X) |
Gibco Neurobasal Plus Medium | FisherScientific | A3582901 | |
StemPro Accutase Cell Dissociation Reagent | ThermoFisher Scientific | A1110501 | |
XC pre-coat | Xona Microfluidics, LLC | XC Pre-Coat | included with XonaChips |
XonaChip | Xona Microfluidics, LLC | XC450 | 450 µm length microgroove barrier |
Humidifier Tray | Xona Microfluidics, LLC | humidifier tray |