The non-human primate (NHP) is an ideal model for studying human retinal cellular therapeutics due to the anatomical and genetic similarities. This manuscript describes a method for submacular transplantation of retinal pigment epithelial cells in the NHP eye and strategies to prevent intraoperative complications associated with macular manipulation.
Retinal pigment epithelial (RPE) transplantation holds great promise for the treatment of inherited and acquired retinal degenerative diseases. These conditions include retinitis pigmentosa (RP) and advanced forms of age-related macular degeneration (AMD), such as geographic atrophy (GA). Together, these disorders represent a significant proportion of currently untreatable blindness globally. These unmet medical needs have generated heightened academic interest in developing methods of RPE replacement. Among the animal models commonly utilized for preclinical testing of therapeutics, the non-human primate (NHP) is the only animal model that has a macula. As it shares this anatomical similarity with the human eye, the NHP eye is an important and appropriate preclinical animal model for the development of advanced therapy medicinal products (ATMPs) such as RPE cell therapy.
This manuscript describes a method for the submacular transplantation of an RPE monolayer, cultured on a polyethylene terephthalate (PET) cell carrier, underneath the macula onto a surgically created RPE wound in immunosuppressed NHPs. The fovea-the central avascular portion of the macula-is the site of the greatest mechanical weakness during the transplantation. Foveal trauma will occur if the initial subretinal fluid injection generates an excessive force on the retina. Hence, slow injection under perfluorocarbon liquid (PFCL) vitreous tamponade is recommended with a dual-bore subretinal injection cannula at low intraocular pressure (IOP) settings to create a retinal bleb.
Pretreatment with an intravitreal plasminogen injection to release parafoveal RPE-photoreceptor adhesions is also advised. These combined strategies can reduce the likelihood of foveal tears when compared to conventional techniques. The NHP is a key animal model in the preclinical phase of RPE cell therapy development. This protocol addresses the technical challenges associated with the delivery of RPE cellular therapy in the NHP eye.
RPE transplantation holds great promise for the treatment of inherited and acquired retinal degenerative diseases. These conditions include retinitis pigmentosa (RP, rod-cone dystrophy) and advanced forms of AMD such as GA. Collectively, these disorders represent a significant proportion of currently untreatable blindness globally1,2. The advanced stages of AMD are categorized into neovascular AMD (nAMD) and GA. While there are effective treatment options for nAMD, such as anti-vascular endothelial growth factor (anti-VEGF) injections, patients with GA have limited treatment options. RP is a highly heterogeneous group of inherited retinal disorders characterized by progressive retinal photoreceptor degeneration. In some patients, the causative genetic defect is located within the RPE rather than the photoreceptors; hence, RPE replacement therapy may be an alternative strategy if gene therapy is not feasible.
There is significant interest in developing effective treatments for these conditions. In particular, RPE transplantation has been gaining traction as a potential therapeutic approach3,4,5,6,7,8. Since the first reports on RPE transplantation appeared in the 1980s9, the field has expanded to include various RPE cell sources, delivery strategies, and experimental models of disease and transplantation10,11,12,13,14. Among the various animal models, only the NHP has a 'macula lutea' with a 'fovea centralis,' an anatomic specialization at the posterior pole of the retina shared with humans. The fovea contains a very high density of cone photoreceptors enabling high-resolution central vision15. The NHP also has a similar genomic and proteomic make-up16 when compared to humans. These similarities make it an important and appropriate animal model for the study of ocular diseases that affect the human retina17,18.
This manuscript describes a method for the submacular transplantation of an RPE xenograft, supported by a PET cell carrier, in immunosuppressed NHPs. A transvitreal technique for subretinal RPE transplantation in rabbits has been described in a previous manuscript19. However, in NHPs, the presence of the fovea requires particular care during intraoperative manipulation20. In particular, there is a high risk of a foveal tear if subretinal fluid injection methods generate an excessive force on the retina20. The focus of this manuscript is, therefore, on strategies to reduce the risk of inadvertent foveal trauma in NHP.
These include the use of preoperative intravitreal plasminogen injection for the release of parafoveal adhesions and surgical microscope-integrated optical coherence tomography (miOCT) intraoperatively for real-time visualization of the foveal anatomy. A custom-made 25/41 G dual-bore subretinal cannula with intraocular PFCL tamponade under low IOP settings is proposed to allow a more controlled process of foveal detachment. Furthermore, surgical removal of native RPE is recommended before implantation to allow better integration between the transplanted RPE cells and host photoreceptors. Finally, a peri- and postoperative systemic immunosuppression protocol for NHP models is described to improve the survival of the RPE xenograft post-transplantation11,21.
NOTE: All animal experiments were conducted in accordance with The Association of Research in Vision and Ophthalmology (ARVO) for the Use of Animals in Ophthalmic and Vision Research. Ethics approval was obtained from the Institutional Animal Care and Use Committee, SingHealth, Singapore. Animals were housed at the SingHealth Experimental Medicine Centre approved by the Association for Assessment and Accreditation of Laboratory Animal Care (AAALAC). This approval highlights that all animal experiments comply with the standards of the National Advisory Committee for Laboratory Animal Research guidelines set out by the Agri-Food and Veterinary Authority of Singapore. The following experimental protocol was established based on experiments conducted in 6 eyes of 6 Macaca fascicularis (4 male and 2 female, 4 to 6 years old, 2.8 to 4.0 kg) .
1. Achieving immunosuppression in the NHP model
2. Instrument sterilization
3. Preparation of preservative-free triamcinolone (40 mg/mL)
4. Pretreatment of NHP eyes with intravitreal plasminogen (0.25 µg/µL)
5. Surgical table and equipment setup
6. Preparation of anesthesia and positioning of the animal (preferably performed by veterinarian team)
7. Vitrectomy
NOTE: To access the subretinal space for the delivery of the PET-scaffold RPE graft, this protocol recommends a 4-port (valved) 25 G vitrectomy to be performed using a standard vitreoretinal surgical setup and a non-contact, wide-angled, 128° fundus lens. The protocol also recommends the use of a surgical microscope equipped with miOCT to guide several critical surgical steps, including the induction of foveal detachment, implantation of the RPE graft, and subretinal fluid drainage.
8. miOCT-guided foveal detachment
9. Removal of native RPE
10. Loading of the shooter for delivery of RPE cell monolayer transplant
11. miOCT-guided graft implantation and position adjustment
12. miOCT-guided drainage of subretinal fluid
13. Ending the operation
14. Postoperative animal care
15. Postoperative monitoring methods for multimodal imaging
16. Postoperative monitoring methods for full-field electroretinogram (ERG) studies
17. Euthanasia of NHP
The multimodal imaging modalities (fundus photography, fundus autofluorescence imaging (FAF), fundus fluorescein angiography (FFA)-early-phase and late-phase, and optical coherence tomography (OCT)) highlight the features of a successful submacular RPE graft transplant (Figure 1). Fundus photography shows the positioning of the RPE graft transplant at the fovea without migration over time. FAF imaging shows minimal changes in hyper-autofluorescence (demonstrated by white, high-intensity areas) overlapping the RPE graft. Early- and late-phase FFA do not show any obvious leakage (demonstrated by white, high-intensity areas that enlarge with time) surrounding the RPE graft. Initial images at Day 3 show window defect due to the removal of native RPE before graft implantation. Macular OCT images show the preservation of outer retinal layers (in particular, the photoreceptor layer) over the RPE graft as time progresses. Hematoxylin and eosin staining shows intact retinal layers with no evidence of microtears. The preservation of the outer nuclear layer above the peripheries of the graft suggests that the RPE cells are performing their physiological functions of maintaining photoreceptor health.
The intraocular and external views of the 25/41 G dual-bore cannula highlight the mechanism by which the IOP is controlled during subretinal injection (Figure 2). BSS enters the subretinal space during subretinal fluid injection via the central longer cannula. Significant increases in intraocular pressure cause the BSS within the vitreous cavity to exit the eye via the larger metal bore of the cannula. BSS then travels along the cannula and is eventually ejected from the egress port near the cannula hub. To assess whether the cannula is working as expected, ensure that fluid flows from the egress port near the cannula hub.
The miOCT allows the visualization of the bleb dimensions and a potential foveal tear intraoperatively during foveal detachment (Figure 3). Figure 3A1–A3 highlight a case of bleb with a foveal tear. In Figure 3A1, while the inferior bleb is visible under the surgical microscope, visualization of the tear is difficult. Figure 3A2 shows the longitudinal section of a bleb without any tears. Figure 3A3 shows a foveal tear when assessing the vertical section of the bleb. Figure 3B1–B3 show a successfully created bleb without the presence of any tears.
The absence of significant deterioration in the ERG waveforms suggests that the global function of both rod and cone photoreceptors is maintained with subretinal RPE xenografts (Figure 4). The ERG waveforms show the overall function of the retina. In particular, attention should be paid to the A-waves to determine any loss of photoreceptor function.
Figure 1: Postoperative in vivo analysis with multimodal imaging. (A) In vivo imaging of the left eye submacular RPE graft transplant (yellow on fundus photography) on various imaging modalities (left to right columns: fundus photography, autofluorescence, fundus fluorescein angiography-early phase, fundus fluorescein angiography-late phase, optical coherence tomography) for time points up to 3 months (top to bottom rows: Days 3, 14; Months 1, 3). The asterisk on the fundus photograph indicates the site of the retinotomy; the white dashed arrow indicates the direction of the line scan. The yellow drawn shape on fundus autofluorescence imaging highlights the location of the transplant. The white triangles on the OCT images indicate the respective lateral edges of the graft (as per the line scan on the color fundus image). (B) Hematoxylin and eosin staining of the transplant under atrophic fovea (due to intraoperative tear) with layers labeled. Scale bars = 1 mm in A (autofluorescence and FA images), 200 µm in A (OCT images), and 100 µm in B. Abbreviations: FA = fundus angiography; OCT = optical coherence tomography; RGC = retinal ganglion cell layer; INL = inner nuclear layer; ONL = outer nuclear layer; RPE = retinal pigment epithelium. Please click here to view a larger version of this figure.
Figure 2: Intraocular and external views of the 25/41 G dual-bore cannula. (A) Intraocular view of the 25/41 G dual-bore cannula during subretinal bleb creation. The white arrow points to the longer central cannula for subretinal injection. The dashed arrow points to the opening of the egress cannula through which the BSS passes to exit the eye. (B) External view of the 25/41 G dual-bore cannula. The asterisk marks the egress port near the cannula hub from which the intraocular BSS is drained. Abbreviation: BSS = balanced salt solution. Please click here to view a larger version of this figure.
Figure 3: Intraoperative microscope images and miOCT images of subretinal bleb complicated by a foveal tear. (A1) An intraoperative microscope image showing the position of longitudinal (blue) and transverse (red) scans in a bleb with a foveal tear. (A2) Longitudinal miOCT scan showing a subretinal bleb at the foveal region (yellow arrow). (A3) Transverse miOCT scan capturing a foveal tear (white arrowhead), along with a retinotomy (asterisk and a subretinal bleb (yellow arrow). (B1) An intraoperative microscopic image showing the position of longitudinal (blue) and transverse (red) scans in a successfully formed bleb. (B2) Longitudinal miOCT scan showing a subretinal bleb at the foveal region (yellow arrow). (B3) Transverse miOCT scan showing a successfully created subretinal bleb with an intact fovea superiorly (white diamond). Abbreviation: miOCT = microscope-integrated optical coherence tomography. Please click here to view a larger version of this figure.
Figure 4: ERG of RPE xenograft-transplanted eye. For the functional assessment of the retina, full-field ERG assessments of the RPE-xenografted eye performed at baseline (top row) and 3 months post-transplantation (bottom row) show no significant effect of the RPE xenograft transplantation on any response amplitudes, timing, or waveform under either dark-adapted or light-adapted conditions. Abbreviations: RPE = retinal pigment epithelium; ERG = electroretinogram; DA = dark-adapted; LA = light-adapted. Please click here to view a larger version of this figure.
There are two main approaches being evaluated for submacular RPE transplantation-the injection of an RPE suspension and the transplantation of a monolayer RPE graft. A detailed comparison between the two methods is beyond the scope of this manuscript. However, the transplantation of a monolayer RPE graft may be advantageous as the RPE cells are more organized in a monolayer than in a suspension. RPE cells in the graft are organized in a confluent monolayer, which resembles the organization of the physiological RPE cell layer and enables the transplanted RPE cells to perform their physiological functions. This enables more precise dosing parameters compared to cell suspensions, which is highly relevant for regulatory work and industrial scale-up.
Delivery of the RPE patch graft into the subretinal space requires careful manipulation of the macula and accurate insertion of the graft in the subretinal space. Technological advances in microsurgery, such as miOCT, and a better understanding of intraoperative retinal tissue dynamics have reduced the learning curve of this procedure. In this discussion, the rationales of the following aspects will be explained: i) pre-operative plasminogen injection; ii) the use of intraoperative miOCT; iii) the use of a custom 41 G dual-bore cannula, low IOP settings, and PFCL for subretinal bleb creation; iv) scraping of the native RPE cell layer before transplantation; v) the use of sirolimus, triamcinolone, doxycycline, and minocycline to reduce immunogenic graft rejection.
Preoperative plasminogen injections release parafoveal retinal adhesions
In the initial experiments, it was challenging to detach the fovea with a single fluid wave. On assessment with miOCT, the images revealed the presence of parafoveal outer retinal adhesions to the native RPE along with evidence of intraretinal trauma20. These adhesions may have led to a vertical expansion of the bleb rather than the subretinal fluid wave spreading across the retinal contour, resulting in foveal trauma. Plasminogen is the inactive precursor of plasmin, a protease targeting fibronectin and laminin. Ocriplasmin is a bioengineered variant of human plasmin, approved by the Food and Drug Administration (FDA) and European Medicines Agency (EMA) for the treatment of symptomatic vitreomacular traction with or without a concomitant macular hole. However, postapproval reports of cystoid macula edema development after ocriplasmin injection have suggested a more extensive effect of the enzyme on the retina23.
Although the exact mechanisms have not been identified, it was suggested that plasmin could weaken retinal adhesion through the degradation of the interphotoreceptor matrix elements responsible for photoreceptor-RPE adhesion24. In this protocol, NHP eyes were treated with intravitreal plasminogen 1 week before surgery to release the parafoveal outer retinal adhesions. Under the assumption that the photoreceptor-RPE adhesion is weakened, a lower force is required to detach the neurosensory retina, including the distal parafoveal ring, which typically resists the subretinal fluid wave20. Thus, the force administered during retinal bleb detachment results in the expansion of the bleb across the retinal contour rather than stretching the retina tangentially. This reduces the risk of foveal tears. However, it should be noted that the effect of plasminogen on long-term graft survival was not studied in this protocol. Future studies should attempt to determine this effect.
miOCT provides anatomical feedback to guide subretinal bleb creation, graft implantation, and subretinal fluid drainage
Intraoperative, atraumatic manipulation of the macula is key to achieving good transplantation outcomes. However, microstructural changes of the macula related to manipulation may not always be evident on the operating microscope. In such procedures, the miOCT is an important tool that provides real-time, three-dimensional, intraoperative feedback of the macular structure. miOCT is especially useful during the steps of foveal detachment, graft implantation, and drainage of the subretinal fluid using a fluid-air exchange. During foveal detachment, miOCT can determine the vertical and horizontal dimensions of the bleb. Foveal microtears, which may not be visualized clearly on the surgical microscope, can be confirmed by miOCT (Figure 3). During the graft implantation, miOCT images guide by showing the graft's location or proximity to the fovea, through the often less-transparent, detached retina. miOCT can also highlight possible areas of retinal adhesion during a difficult transplantation process25. Finally, in the subretinal fluid drainage process, miOCT can reliably guide subretinal fluid drainage until complete retinal-RPE graft contact is achieved.
The combination of a dual-bore cannula, low IOP settings, and PFCL vitreous tamponade synergistically reduces macular trauma during subretinal bleb creation
Tangential retinal stretching and fluid turbulence can occur during the subretinal BSS injection for foveal detachment leading to unwanted foveal tears. To counteract these phenomena, factors, such as the relative position and distance from the foveal center where the injection is initiated, injection volume and velocity, vitreous tamponade, choice of subretinal instrumentation, and IOP have all been shown to be relevant20,26,27. The subretinal bleb for foveal detachment should be situated at a location adequately distant from the fovea, as retinal stretching may be highest at the bleb initiation site27. IOP should also be kept low throughout the creation of the subretinal bleb. When the IOP of the eye is high, a higher vertical increase in bleb size rather than expansion along the contour of the retina is observed, whereas blebs are shallower at lower pressures20. Furthermore, although an intravitreal injection of 50 µL will effectively double the IOP in humans28, given the shorter eye length in NHPs, the IOP rise during subretinal injection will probably be higher and more rapid than in humans. While most vitrectomy machines adjust for IOP fluctuation, the adjustment is not a simultaneous but rather a reactive process that occurs as subretinal injection proceeds. Hence, the higher the IOP, the higher the risk of retinal overstretching and resultant foveal trauma. Thus, it is essential to maintain a stable low IOP during subretinal injection.
A commercial 20/41 G (DORC) or a custom-made 25/41 G dual-bore subretinal cannula is recommended for subretinal injection. The cannula allows fluid to exit the vitreous cavity in exchange for BSS injected into the subretinal space. This ensures the 'simultaneous' regulation of IOP during the subretinal injection. A schematic of the dual-bore cannula is seen in Figure 2. Finally, PFCL is utilized to reduce the risk of foveal tears20,26,27. As PFCLs, such as octaline, have higher specific gravity, they exert a downward force on the retina during foveal detachment29. This further stabilizes the foveal detachment bleb creation process and enhances the expansion of the bleb along the retinal contour. This technique has been successfully used for the subretinal injection of rtPA in the setting of massive submacular hemorrhage due to nAMD30.
Pretransplantation removal of native RPE allows the restoration of RPE–photoreceptor complex
Host RPE should be removed before graft transplantation. This is because the restoration of the RPE-photoreceptor complex is required to enable the RPE transplant to perform its physiological functions of supporting the photoreceptors21. The host RPE, if not removed, may pose as a mechanical barrier, which prevents the restoration of this complex. It can be removed either through the administration of RPE-toxic chemicals or by using physical means of removal. Chemical removal methods include the systemic or subretinal administration of sodium iodate31,32. As sodium iodate causes widespread degeneration of photoreceptors, RPE cells, and Choriocapillaris when administered, its retinal and systemic toxicity precludes its use for human trials32,33. Hence, physical intraoperative techniques are preferred. Various physical methods have been conceptualized. When physical methods are utilized, it is crucial that the Bruch's membrane remains undamaged. Many in vitro studies have demonstrated the dependence of RPE graft survival on an intact Bruch's membrane34,35,36.
Attempts at hydraulic debridement were associated with breaks in Bruch's membrane, an increased rate of epiretinal membrane development, and proliferative vitreoretinopathy, resulting in tractional retinal detachment37. A diamond-dusted spatula proposed for RPE debridement also led to breaks in the Bruch's membrane, resulting in cellular proliferation from the choroid into the subretinal space38. Interestingly, a custom-made extendable loop instrument could remove the overlying RPE with preservation of Bruch's membrane in the eyes of rabbits and pigs11,39. The removal of the underlying RPE is also useful for establishing animal models with RPE and outer retinal atrophy, similar to the advanced atrophic form of AMD. When a focal area of RPE is removed from the macula, the RPE wound closes via the hypertrophy of the remaining RPE cells. However, this wound healing response is associated with atrophy of the outer nuclear layer40. While the creation of an animal model is beyond the scope of this manuscript, a similar procedure can create an animal model of an advanced atrophic AMD phenotype for the testing of RPE-derived cell therapeutics.
The use of sirolimus, triamcinolone, doxycycline, and minocycline to reduce immunogenic graft rejection
The subretinal space is thought to be an immune-privileged site, maintained by an intact blood-retinal barrier and other factors41. In many studies involving the subretinal transplantation of stem-cell derivatives with an intact blood-retinal barrier, immunosuppressive drugs play a negligible role in graft survival42. The outer blood-retinal barrier is thought to be formed by the native RPE layer and the tight junctions between the RPE cells. While native RPE removal allows better integration of the transplanted RPE and host photoreceptors, the blood-retinal barrier is disrupted in the process, increasing the likelihood of an immune rejection. Classically, T-cells are central to the process of transplant rejection of other organs such as the kidney and liver43. Hence, initial immunosuppressive regimens for retinal tissue transplantation were targeted towards reducing these adaptive immune responses.
Sirolimus, a mechanistic target of rapamycin inhibitor, and tacrolimus, a calcineurin inhibitor, are examples of immunosuppressive drugs targeting adaptive immune responses. However, despite adequate T-cell suppression, graft survival rates remain low. In addition, RPE cells are known to suppress T-cell activation through the release of inhibitory factors and promote the generation of regulatory T-cells44. Hence, it has become increasingly apparent that adaptive immunity may not be the only contributor to graft rejection42. Subretinal transplantation of cellular products can result in the accumulation and activation of microglia45.
Microglia are the macrophages of the retina. They consist of two main populations: 1) the perivascular microglia of the inner retinal vasculature and 2) the microglia within the retinal tissue parenchyma. As microglia are part of the innate immune response, intravitreal glucocorticoids, such as triamcinolone, can suppress cytokine-mediated proliferation46. Doxycycline and minocycline can also suppress microglial activation and should be considered47,48. Lastly, differences in immune rejection of RPE allografts versus xenografts are incompletely understood49. For instance, alloantibodies against induced pluripotent stem cell-derived RPE cells have been reported in the serum of in vivo immune rejection models. However, the role of these antibodies and the importance of antibody-mediated rejection in graft survival remains unknown50. Hence, a multidrug regimen utilizing sirolimus for the suppression of adaptive immunity and a combination of triamcinolone, doxycycline, and minocycline for innate immunity suppression is proposed. This regimen has been successfully used in rabbits with good graft survival outcomes and minimal systemic effects11.
Limitations of this surgical technique
This paper describes a possible surgical method to deliver an RPE graft sheet into the subretinal space of NHP; however, this does not mean this is the only optimized way. Different vitreo-retinal surgeons may have other preferences for instrumentation and technique. For example, this implantation device design can only deliver flat implants supported with a stiffer cell carrier and hence may not be suitable for relatively flexible (or rolled) implants. RPE suspension transplants can omit much of this technique. Accordingly, surgical details will require modification based on each delivery strategy.
As interest in cellular therapeutics for the treatment of degenerative retinal diseases continues to grow, the NHP animal model will be essential in preclinical studies for studying the factors affecting RPE graft survival. In this manuscript, strategies are proposed to enable the smoother delivery of a submacular monolayer RPE graft in the NHP eye. Methods for better visualization of intraoperative complications are also recommended. It is anticipated that these methods will continue to improve as the use of cellular therapeutics expands. Future method papers should also consider proposing a comprehensive list of investigations to assess various structural and functional aspects of the graft.
The authors have nothing to disclose.
This study was supported by IAF-PP (HMBS Domain) (OrBID): OculaR BIomaterials and Device, A*STAR, Singapore (H17/01/a0/013), the NUS Start-up grant NUHSRO/2016/100/SU/01, NUHS Clinical Scientist Program (NCSP) grant and National Research Foundation Competitive Research Programme, Singapore (NRF-CRP21-2018-0008) to X.S., Hong Leong Endowed Professorship funds to G.E.H. and B.V.S. We would like to acknowledge the veterinary team at the Translational Pre-Clinical Model Platform (Singapore Eye Research Institute, Singapore) for providing support in NHP surgery preparation and animal follow-up. We would like to extend our appreciation to Jill Teo and colleagues from C. Zeiss Meditec Singapore for technical support for the OPMI-Lumera 700 with integrated intraoperative OCT device.
1% Mydriacyl (Tropicamide 1.0%) Sterile Ophthalmic preparation | Alcon | SIN 4715P | Surgical procedure |
10% Neutral buffered formalin | Leica | 3800598 | Histology procedure |
2.5% Mydfrin (Phenylephrine hydrochloride) Ophthalmic solution | Alcon | No. 01785 | Surgical procedure |
25 G AWH Vivid Chandelier | Synergetics | 56.54.25P | Surgical procedure |
25 Ga Bi-Blade Vitreous Cutter Combined Wide-Field Stellaris Elite Pack | Bausch & Lomb | SE5525WVB | Surgical procedure |
AMO ENDOSOL Balanced Salt Solution for ophthalmic irrigation | Abbott Medical Optics | 15020 | Surgical procedure |
Apo-minocycline | Apotex Inc | 2084104 | Immunosuppression |
AUROVISC – Hypromellose Ophthalmic Solution USP 2% w/v | Aurolab | TN 00002387 | Surgical procedure |
Autoclave MELAG, Vacuklav | MELAG | 1131-B2300 | Surgical procedure |
Autostainer XL (ST5010) | Leica | 2433 | Histology procedure |
Balanced Saline Solution | Beaver Visitec | 581732 | Surgical procedure |
Cotton Bud | WINNER MEDICAL | 1NA6-100 | Surgical procedure |
Diagnosys Espion E3 Console | Diagnosys | 272 | Ophthamic imaging |
Doxycycline | Yung Shin | MAL 19950403AEZ | Immunosuppression |
Eosin Y | Merck Millipore | 1.15935.0100 | Histology procedure |
ERG-Jet contact lens electrodes | Fabrinal | F-06 | Ophthamic imaging |
Extendable PolyTip Cannula 25 G/38 G | MedOne | 3247 | Surgical procedure |
FlexTip Brush (25 g) 1.5 mm | MedOne | 3222 | Surgical procedure |
Fluoresceine 10% Faure | Curatis AG | 5030376 | Ophthamic imaging |
Gauze Swab | WINNER MEDICAL | 1NP3275 | Surgical procedure |
Hamilton gas tight syringe 250 µL | Hamilton | 81101 | Surgical procedure |
Heidelberg Spectralis HRA + OCT Computer System | Heidelberg Engineering | N.A. | Ophthamic imaging |
Hematoxylin Gill II | Merck Millipore | 3801520 | Histology procedure |
Inverted microscope eclipse Ti-E main body (100-240V) | Nikon | 33131 | Histology procedure |
Ketamin injection | Ceva | 37711/58317 | Surgical procedure |
Lithium carbonate | Merck Millipore | 1.05680.0250 | Histology procedure |
Monkey plasminogen | Molecular Innovations | SKU-CYPLG | Surgical procedure |
Non-contact wide angled 128 degree fundus lens | C. Zeiss Medtech | Resight 700 | Surgical procedure |
Non-woven Ophthalmic Drape | Alcon | 8065103120 | Surgical procedure |
Ophthalmic Corneal/Scleral V-Lance Knife 20 G | Alcon | 8065912001 | Surgical procedure |
Paraffin Embedding Station | Leica | EG1150 H | Histology procedure |
Paraplast High Melt Paraffin | Leica | 39601095 | Histology procedure |
Phloxin B | Merck Millipore | 1.15935.0025 | Histology procedure |
Prepowdered Surgical Gloves | MAXITEX | 85-173-2/85-173-3/85-173-4 | Surgical procedure |
PRODINE Povidone-Iodine Solution BP | ICM PHARMA | PMLBLP20-01 | Surgical procedure |
Righton Slit Lamp Model MW50D (RAA133CB) | Righton-Oph | 5200162 | Ophthamic imaging |
Rotary microtome | Leica | RM2255 | Histology procedure |
Safil Polyglycolic acid, braided, coated, absorbable surgical suture 7/0 | B.Braun | G1048711 | Surgical procedure |
SHINCORT I.M. INJ. Triamcinolone Acetonide 40 mg/mL | Yung Shin | SHI40 SGP-2610015-001 | Surgical procedure |
Single-Use Hypodermic Needle 21 G | B.Braun | 4657527 | Surgical procedure |
Single-Use Hypodermic Needle 23 G | B.Braun | 4657667 | Surgical procedure |
Sirolimus | Pfizer | SIN12034P | Immunosuppression |
Stainless steel subdermal needle electrode | OcuScience | F-E2 | Ophthamic imaging |
Stellaris Elite vision enhancement system | Bausch & Lomb | BL15455 | Surgical procedure |
Sterican Single Use Insulin Needles Long Bevel 27 G 12 mm | B.Braun | 4665406 | Surgical procedure |
Sterican Single Use Insulin Needles Long Bevel 30 G 12 mm | B.Braun | 4656300 | Surgical procedure |
Surgical gown + 2 Hand Towels | STERIL | APP10 00 01 | Surgical procedure |
Tegaderm Film | 3M | 1626W | Surgical procedure |
TERUMO Syringe 1 cc/mL Luer SlipTip with needle 26 G | Teruma | SS-01S | Surgical procedure |
TERUMO Syringe 3 cc/mL Luer LockTip | Teruma | SS-03L | Surgical procedure |
TERUMO Syringe 5 cc/mL Luer LockTip | Teruma | SS-05L | Surgical procedure |
TobraDex (Tobramycin, Dexamethasone) Sterile Ophthalmic Ointment | Alcon | No. 01577 | Surgical procedure |
Topcon Retinal Camera TRC-50DX | Topcon | 948605 | Ophthamic imaging |
Vidisic Gel | Bausch & Lomb | GB41789155517 | Surgical procedure |
Xylazil-20 | Ilium | 38653/50276 | Surgical procedure |
Zeiss Opmi Rescan 700 | Carl Zeiss Meditec AG | 7210 | Surgical procedure |