An anion exchange resin-based method, adapted to liquid impingement-based bioaerosol sampling of viruses is demonstrated. When coupled with downstream molecular detection, the method allows for facile and sensitive detection of viruses from bioaerosols.

Abstract

This protocol demonstrates a customized bioaerosol sampling method for viruses. In this system, anion exchange resin is coupled with liquid impingement-based air sampling devices for efficacious concentration of negatively-charged viruses from bioaerosols. Thus, the resin serves as an additional concentration step in the bioaerosol sampling workflow. Nucleic acid extraction of the viral particles is then performed directly from the anion exchange resin, with the resulting sample suitable for molecular analyses. Further, this protocol describes a custom-built bioaerosol chamber capable of generating virus-laden bioaerosols under a variety of environmental conditions and allowing for continuous monitoring of environmental variables such as temperature, humidity, wind speed, and aerosol mass concentration. The main advantage of using this protocol is increased sensitivity of viral detection, as assessed via direct comparison to an unmodified conventional liquid impinger. Other advantages include the potential to concentrate diverse negatively-charged viruses, the low cost of anion exchange resin (~$0.14 per sample), and ease of use. Disadvantages include the inability of this protocol to assess infectivity of resin-adsorbed viral particles, and potentially the need for the optimization of the liquid sampling buffer used within the impinger.

Introduction

The purpose of this method is to provide a highly sensitive bioaerosol sampling platform to facilitate molecular detection of negatively-charged viruses from bioaerosols. Microorganisms, including viral particles, can survive in bioaerosols for extended periods of time1. Bioaerosols can travel over relatively long distances and maintain viability and infectivity, as evidenced by an outbreak of Legionnaires' disease that originated from industrial cooling towers located at a distance of 6 km from the affected individuals and resulted in 18 fatalities2. Indirect transmission of viruses to humans mediated by bioaerosols can occur in multiple settings and has been demonstrated for norovirus outbreaks in schools and restaurants3,4. Similarly, bioaerosol transmission of viruses can occur in agricultural settings such as in swine and poultry farms, with this transmission route being considered as a major factor in the movement of viruses between production facilities5,6,7,8,9.

Effective sampling of virus-laden bioaerosols allows for improvement in rapid diagnostics and preparedness for outbreak prevention, as shown in demonstrations in which H5 influenza A viruses were detected from bioaerosols in live animal markets in China and the United States10,11. Current bioaerosol sampling technologies involve a number of different particle capture principles, and can be broadly categorized into impingers, cyclones, impactors, and filters12. It is beyond the scope of this protocol to exhaustively cover all advantages and disadvantages of these platforms for sampling of viruses from bioaerosols; however, it can be stated that the majority of these sampling devices have not been optimized for the collection of viruses and bacteriophages13. Furthermore, infectivity of viral particles is often negatively affected, with liquid impingers considered to maintain viral infectivity more effectively than sampling devices such as solid impactors or filters14. However, one disadvantage of liquid impingement is the target dilution effect, which occurs because viruses are collected in relatively large volumes (typically ≥20 mL) of liquid in the collection vessel. Another important disadvantage involves the suboptimal efficiency of liquid impingers to concentrate particles <0.5 µM in size15. However, capture efficiency of these devices can be improved by immobilization on solid matrices, as immobilization can enhance preservation of viral nucleic acids and viral infectivity16,17.

We have previously demonstrated that anion exchange resin is an effective tool for the capture and concentration of viruses from liquid matrices, including F-RNA bacteriophages, hepatitis A virus, human adenovirus, and rotavirus18,19,20. As defined by the manufacturer, the anion exchange resin utilized in this work is a macroreticular polystyrene strong base anion exchange resin in which functionalized quaternary amine groups mediate attraction and capture of anions in a liquid medium21. Consequently, the anion exchange resin is expected to capture viruses with net-negative surface charges, including many enteric viruses, influenza viruses and other viruses relevant to public and animal health.

The current protocol involves the addition of anion exchange resin to a liquid impinger. In this system, the resin serves as a secondary concentration step for viral particles captured in the impinger liquid. Nucleic acids can then be directly eluted in small volumes, providing a concentrated sample for molecular analyses. Thus, the main advantage of this method is the improvement in viral detection sensitivity, primarily through reduction in sample volume. Additionally, due to the inherent non-specific capture of negatively-charged viruses, the method is likely applicable for detection of a large number of viruses of interest. Here, the method is demonstrated for vaccine strains of type A and type B influenza viruses and the FRNA coliphage MS2 (MS2). These viruses are subsequently detected using standard qRT-PCR assays as previously described22. The end-point user should not expect to encounter difficulties in performing this method, because modifications to currently existing equipment do not constitute major disruptions to the conventional flow of bioaerosol sampling and analysis.

Protocol

1. Setup of the Bioaerosol Chamber (See Figure 2)

  1. Pre-load the liquid impingers with 20 mL of 0.01 M phosphate buffered saline, pH 7.5 (PBS).
    1. Add 0.5 g of anion exchange resin and suspend within the PBS of one of the liquid impingers, with another liquid impinger serving as a control.
  2. Position liquid impingers in parallel inside the bioaerosol chamber using clamp stands with aerosol inlets facing the nebulizer.
    NOTE: See Figure 2 for additional detail.
  3. Co-locate a direct-read aerosol monitor near the liquid impingers to measure mass concentration (mg/m3) of the bioaerosol.
  4. Co-locate additional direct-read instrumentation (indoor air quality monitor and thermal anemometer) near the liquid impingers to monitor environmental variables, such as temperature, relative humidity and wind speed, within the bioaerosol chamber.
  5. Run axial fans in the corners of the bioaerosol chamber to facilitate mixing of aerosol.
    NOTE: Axial fans run at a fixed speed and are not adjustable.

2. Model Bioaerosolization Experiments (see Figure 3)

  1. Perform serial, 10-fold dilutions of MS2 bacteriophage and influenza vaccine to desired concentrations in phosphate-buffered saline (PBS).
    NOTE: To demonstrate the method here, 103.5 FFU/mL of the type A and B influenza virus vaccine strains and 105 PFU/mL of the MS2 bacteriophage are utilized. To determine titers for the inocula, bacteriophages are propagated in Escherichia coli HS (pFamp)R and enumerated as previously described20. The commercial vaccine contains known quantities of four live attenuated influenza virus strains, two type A influenza viruses and two type B influenza viruses, expressed in fluorescent focus units or FFU.
  2. Prepare inocula within the glass vessel of a 6-jet collision nebulizer by creating suspensions of desired concentrations of viral particles in 100 mL of PBS and install within the custom bioaerosol chamber.
  3. Initiate instrumentation to measure variables within the bioaerosol chamber, such as temperature, % relative humidity, carbon dioxide concentration, and wind speed (generated using an axial fan). Use a direct-read aerosol monitor to track mass concentration within the bioaerosol chamber and to establish consistency within and between trials.
  4. Seal the bioaerosol chamber and purge for 10 min with HEPA-filtered air.
  5. Deliver filtered, dried air to the nebulizer operating at 6.9 kPa.
  6. Generate a target concentration of viral bioaerosols (via nebulizer) in each bioaerosol chamber trial. For this demonstration, bioaerosols with a concentration of 5 mg/m3 are generated.
  7. Once the target mass concentration of the aerosol has been reached, stop nebulization.
  8. Operate an air sampling pump for each liquid impinger that has been calibrated to a flow rate of 12.5 L/min. Conduct calibration using a primary flow standard before and after each sampling event to ensure consistency in sampling volume. Supply dilution air using a HEPA-filtered line located near the nebulizer and maintain constant pressure in the chamber.
  9. Actively sample the bioaerosol chamber atmosphere for a period of 40 min to achieve a sampling volume of 500 L per sample.
    NOTE: Sampling for 40 min at 12.5 L/min with two pumps in parallel allows for sampling of 1,000 L of the bioaerosol. Thus, at the completion of the experiment, it is expected that the majority of the air present in the bioaerosol chamber has been sampled and released into the environment via a HEPA-filtered system. This is evidenced by the decrease in particle concentration. Post-experiment, surfaces are decontaminated with 10% household bleach and 70% ethanol. Indicators are used in this demonstration; however, if known pathogenic organisms are used in this system, additional biosafety measures may be implemented as needed.

3. Nucleic Acid Extraction and qRT-PCR Detection

  1. Isolate nucleic acids directly from anion exchange resin and, for comparative purposes, from the liquid used within the liquid impingers. In this example, a RNA isolation procedure is described, but a similar protocol could be used for DNA viruses.
    1. Nucleic acid isolation from the anion exchange resin.
      1. Transfer all of the anion exchange resin-containing liquid of the liquid impinger to a sterile 50 mL conical tube.
      2. Allow the resin to settle, and slowly decant the liquid sample from the anion exchange resin. Use a 1 mL pipette tip to remove all of the remaining liquid from the anion exchange resin.
      3. From a viral RNA isolation kit, add 560 µL of viral lysis buffer containing carrier RNA directly to the anion exchange resin and incubate for 10 min at room temperature with periodic mixing.
      4. Using a 1 mL pipette tip, transfer the viral lysate (the viral lysis buffer) to a sterile 1.5 mL conical tube and proceed with RNA isolation using a viral RNA isolation kit (see Table of Materials) in accordance with the manufacturer's instructions, except that RNA is eluted in a total volume of 60 µL of elution buffer.
    2. Nucleic acid isolation from liquid impingers.
      1. Pipette 140 µL of the liquid sample into a sterile 1.5 mL conical tube and perform RNA isolation using the viral RNA isolation kit in accordance with the manufacturer's instructions, with the exception of eluting RNA in a total volume of 60 µL of elution buffer.
        NOTE: 140 µL is the maximum sample volume that can be processed with the specific viral RNA isolation kit employed here in a single-step preparation.
  2. Perform qRT-PCR for detection of MS2 and influenza A and B viruses as previously described23,24. In this demonstration, 5 µL of nucleic acid eluates are used for qRT-PCR.

Representative Results

Figure 1 demonstrates the principle behind charge-based capture of viruses from bioaerosols via inclusion of resin in liquid-based impingers. Figure 2 shows the setup of the custom-built bioaerosol chamber. Figure 3 describes the steps involved in setting up the aerosolization experiment and measures to ensure quality control. Figure 4 shows amplification curves for qRT-PCR detection of negatively-charged viruses captured from bioaerosols. Table 1 shows the primers and probes used for qRT-PCR for the example viruses used in this study.

Using MS2 and influenza viruses contained within the influenza vaccine as models in the custom bioaerosol chamber, the liquid impingers modified with anion exchange resin allowed for approximately 3x to 9x improvement in viral detection, depending on the specific virus, compared to direct testing of impingement liquid22. As shown in representative qRT-PCR amplification curves (Figure 4), detection of type A influenza viruses could be achieved up to 3.26 cycles sooner when anion exchange resin was used compared to direct testing of the impingement liquid. Considering that in a qRT-PCR that is 100% efficient, a gain of one Ct corresponds to a 2-fold increase in target concentration, this difference is equivalent to a 9.58x improvement in detection.

Figure 1
Figure 1: Liquid impingement coupled with anion exchange resin. Each of the modified bioaerosol sampling devices incorporates an anion exchange resin into its design. Each resin bead is a 0.5 to 1.0 mm sphere with a porous surface, a characteristic that increases the anion exchange surface area. Functional quaternary ammonium groups allow for capture of ions in liquid media, mediating capture of viruses with net-negative surface charges, including MS2 coliphages and influenza viruses, which are used in this protocol as model organisms (a tailed bacteriophage is drawn here as an example for captured viruses). Nucleic acid isolation is then performed directly from the resin (using commercially available kits), with the sample suitable for most molecular detection strategies (qRT-PCR employed here). Please click here to view a larger version of this figure.

Figure 2
Figure 2: Custom bioaerosol chamber schematic. A: 6-jet nebulizer supplied with filtered and dried air at a generating pressure of 6.9 kPa; B: Axial fans to facilitate uniform bioaaerosol mixing; C: Aerosol monitor to identify the relative bioaerosol concentrations; D: Liquid impinger with resin; E: Liquid impinger without resin; F: Thermal anemometer to measure wind speed; G: Air quality monitor to measure other environmental variables including temperature, carbon dioxide, and percent relative humidity; H: Active sampling pumps calibrated to 12.5 L/min; I: Pneumatically sealed glove ports for positioning sampling equipment within the bioaerosol chamber; J: Observation window. This figure was reused from previous work with permission from the publisher22. Please click here to view a larger version of this figure.

Figure 3
Figure 3: Workflow of the bioaerosolization experiment. Please click here to view a larger version of this figure.

Figure 4
Figure 4: Anion exchange resin improves qRT-PCR based detection of negatively-charged viruses in bioaerosols. In this example, type A influenza viruses at an inoculum concentration of 103.5 FFU/mL were aerosolized into the custom bioaerosol chamber until the bioaerosol mass concentration reached 5 mg/m3. Liquid impingers with and without resin were simultaneously engaged to each sample (500 L) of the bioaerosol. Viral RNA was obtained from the anion exchange resin or from the liquid of the impinger and assayed by qRT-PCR. The experiment was repeated in triplicate. Nucleic acids obtained from resin samples were detected at an average Ct of 26.76, whereas impinger liquid samples were detected at an average Ct of 30.02 (ΔCt of 3.26). This difference in Ct is equivalent to a 9.58x improvement in detection using the anion exchange resin. Please click here to view a larger version of this figure.

Viruses Primer name Primer sequence Reference
MS2 GI Fwd 5'-ATCCATTTTGGTAACGCCG-3' 23
GI Probe 5'-(6-FAM)-TAGGCATCTACGGGGACGA-(BBQ)-3'
GI Rev 5'-TGCAATCTCACTGGGACATAT-3'
IAC Fwd (46F) 5'-GACATCGATATGGGTGCCG-3'
IAC Probe 5'-(Cy5)-CACATTCACCAGGGAGACGCATGAGA-(BBQ)-3'
IAC Rev (186R) 5'-CGAGACGATGCAGCCATTC-3'
type A influenza viruses CDC universal influenza A virus forward primer 5'-GAC CRA TCC TGT CAC CTC TGA C-3' 24
CDC universal influenza A virus reverse primer 5'-AGG GCA TTY TGG ACA AAK CGT CTA-3'
CDC universal influenza A virus probe 5'-(FAM)-TGC AGT CCT CGC TCA CTG GGC ACG-(BHQ1)-3'
type B influenza viruses CDC universal influenza B virus forward primer 5'-TCCTCAACTCACTCTTCGAGCG-3' 24
CDC universal influenza B virus reverse primer 5'-CGGTGCTCTTGACCAAATTGG-3'
CDC universal influenza B virus probe 5'-(JOE)-CCAATTCGAGCAGCTGAAACTGCGGTG-(BHQ1)-3'

Table 1: Primers and probes used in this study. All primers and probes were from Friedman et al. 201123 and Selvaraju & Selvarangan 201024.

Discussion

This protocol outlines a method for sensitive viral capture from bioaerosols using modified liquid impingers. The method is optimized for detection and quantification of the viral load in bioaerosols. The specific modification demonstrated here involves the addition of anion exchange resin to liquid contained within a common liquid impinger. This method was developed for its simplicity in downstream sample processing, whereas other sample processing techniques such as centrifugation, filtration, and precipitation-based methods do not offer such an advantage. Extraction of nucleic acids is performed directly from the resin, obviating the need for high-volume elutions and multiple sample preparation steps, ultimately contributing to improved detection sensitivity of the method via reduction in the effective sample volume. Furthermore, it has been shown that immobilization of viral particles on solid surfaces can contribute to increased stability of viral nucleic acid or retention of viral infectivity17,25. Immobilization may further contribute to increased capture efficiency by reducing losses due to reaerosolization16. The method can be easily coupled with downstream molecular analyses (qRT-PCR demonstrated here). The anion exchange resin may be field-extracted and shipped to a reference laboratory for analysis, while air-sampling equipment can stay dedicated to monitoring in the sampling area. As the principle behind the procedure involves the non-specific capture of viruses carrying a net-negative surface charge, the method is expected to be amenable to the detection of multiple pathogenic viruses of importance to human health and veterinary medicine. As reviewed by Michen and Graule26, a large number of viruses important to public and animal health have net-negative surface charges, with few known exceptions, such as certain strains of rotaviruses and polioviruses.

This protocol does not directly evaluate the effect of environmental conditions on the sensitivity of detection; however, when air sampling is conducted in field settings, it is conceivable that variables such as relative humidity and temperature may affect collection efficiencies across multiple types of air samplers12. Thus, conditions within the bioaerosol chamber may be modified to suit these environmental parameters as needed. The anion exchange resin method has been shown to effectively concentrate multiple viruses from water samples with a wide range of physicochemical properties, indicating that interference from particulate matter, bacteria, and other environmental contaminants is expected to be minimal18. Additionally, collection buffers may require optimization for specific viruses, as in some cases it has been shown that optimizing the collection buffer can lead to improved retention of viral stability27. A main disadvantage of the method as presented is the fact that it cannot determine viral infectivity. Another disadvantage of this protocol is the inability to assess potentially negative effects of nebulization and air sampling on viral stability, including desiccation, shearing, and non-specific adsorption to bioaerosol chamber surfaces22.

The modified bioaerosol sampling devices could be amenable to field-based sampling in multiple settings, including hospitals, schools, agricultural operations, and other venues. Because modifications are made to existing air sampling equipment, it is expected the modified devices would be easily adoptable by operators currently sampling bioaerosols for viruses. The protocol is demonstrated here in a custom-built bioaerosol chamber using MS2 and influenza viruses, which are useful targets for method development due to the fact that they represent examples of non-enveloped and enveloped viruses, MS2 is recognized as a surrogate of enteric viruses and are commonly employed in evaluation of impingers22,26,27,28,29.

Future work will involve optimization of sampling conditions (i.e., air sampling velocity, collection buffers) and inclusion of additional relevant viruses in testing protocols.

開示

The authors have nothing to disclose.

Acknowledgements

This work was supported by funding from the CDC/NIOSH High Plains Intermountain Center for Agricultural Health and Safety (5U54OH008085) and the Colorado Bioscience Discovery Evaluation Grant Program (14BGF-16).

Materials

Escherichia coli bacteriophage MS2 (ATCC 15597-B1) American Type Culture Collection ATCC 15597-B1
FluMist Quadrivalent AstraZeneca Contact manufacturer Viral constitutents of this vaccine are subject to change on an annual basis
CFX96 Touch Real-Time PCR Detection System Bio-Rad 1855195
Primers and probes Integrated DNA Technologies NA
0.2 µM sterile filter NA NA
1 L pyrex bottles or equivalent NA NA
1 mL pipet tips NA NA
1 mL pipettor NA NA
50 mL serological pipet NA NA
PCR tubes NA NA
Pipet-aid or equivalent NA NA
QIAamp Viral RNA Mini Kit Qiagen 52904
QuantiTect Probe RT-PCR Kit Qiagen 204443
Amberlite IRA-900 chloride form Sigma-Aldrich 216585-500G
Phosphate buffered saline Sigma-Aldrich P5368-10PAK
Water (molecular biology grade) Sigma-Aldrich W4502-1L
Eppendorf DNA LoBind Microcentrifuge Tubes ThermoFisher 13-698-791
Falcon 50 mL Conical Centrifuge Tubes  ThermoFisher 14-432-22
Falcon Polypropylene Centrifuge Tubes ThermoFisher 05-538-62
SuperScript III Platinum One-Step qRT-PCR Kit w/ROX ThermoFisher 11745100
SKC Biosampler 20 mL, 3-piece glass set SKC Inc. 225-9593
Vac-u-Go sample pumps SKC Inc. 228-9695
Collison nebulizer (6-jet) BGI Inc. NA
HEPA capsule PALL 12144
Q-TRAK indoor air quality monitor 8554 TSI Inc. NA
Alnor velometer thermal anemometer AVM440-A TSI Inc. NA
SidePak AM510 personal aerosol monitor TSI Inc. NA
Bioaerosol chamber NA NA

参考文献

  1. Pirtle, E. C., Beran, G. W. Virus survival in the environment. Revue scientifique et technique (International Office of Epizootics). 10 (3), 733-748 (1991).
  2. Nguyen, T. M., et al. A community-wide outbreak of legionnaires disease linked to industrial cooling towers–how far can contaminated aerosols spread?. The Journal of Infectious Diseases. 193 (1), 102-111 (2006).
  3. Marks, P. J., et al. Evidence for airborne transmission of Norwalk-like virus (NLV) in a hotel restaurant. Epidemiology and Infection. 124 (3), 481-487 (2000).
  4. Marks, P. J., et al. A school outbreak of Norwalk-like virus: Evidence for airborne transmission. Epidemiology and Infection. 131 (1), 727-736 (2003).
  5. Corzo, C. A., Culhane, M., Dee, S., Morrison, R. B., Torremorell, M. Airborne detection and quantification of swine influenza a virus in air samples collected inside, outside and downwind from swine barns. PLoS One. 8 (8), e71444 (2013).
  6. Anderson, B. D., et al. Bioaerosol sampling in modern agriculture: A novel approach for emerging pathogen surveillance. The Journal of Infectious Diseases. 214 (4), 537-545 (2016).
  7. Hietala, S. K., Hullinger, P. J., Crossley, B. M., Kinde, H., Ardans, A. A. Environmental air sampling to detect exotic Newcastle disease virus in two California commercial poultry flocks. Journal of Veterinary Diagnostic Investigation. 17 (2), 198-200 (2005).
  8. Jonges, M., et al. Wind-mediated spread of low-pathogenic avian influenza virus into the environment during outbreaks at commercial poultry farms. PLoS One. 10 (5), e0125401 (2015).
  9. Otake, S., Dee, S. A., Jacobson, L., Torremorell, M., Pijoan, C. Evaluation of aerosol transmission of porcine reproductive and respiratory syndrome virus under controlled field conditions. The Veterinary Record. 150 (26), 804-808 (2002).
  10. Wu, Y., et al. Aerosolized avian influenza A (H5N6) virus isolated from a live poultry market, China. The Journal of Infection. 74 (1), 89-91 (2017).
  11. Choi, M. J., et al. Live animal markets in Minnesota: A potential source for emergence of novel influenza A viruses and interspecies transmission. Clinical Infectious Diseases. 61 (9), 1355-1362 (2015).
  12. Haig, C. W., Mackay, W. G., Walker, J. T., Williams, C. Bioaerosol sampling: Sampling mechanisms, bioefficiency and field studies. The Journal of Hospical Infection. 93 (3), 242-255 (2016).
  13. Anderson, B. D., Lednicky, J. A., Torremorell, M., Gray, G. C. The use of bioaerosol aampling for airborne virus surveillance in swine production facilities: A mini review. Frontiers in Veterinary Science. 4, 121 (2017).
  14. Verreault, D., Moineau, S., Duchaine, C. Methods for sampling of airborne viruses. Microbiology and Molecular Biology Reviews. 72 (3), 413-444 (2008).
  15. Hogan, C. J. Sampling methodologies and dosage assessment techniques for submicrometre and ultrafine virus aerosol particles. Journal of Applied Microbiology. 99 (6), 1422-1434 (2005).
  16. Yu, K. -. P., Chen, Y. -. P., Gong, J. -. Y., Chen, Y. -. C., Cheng, C. -. C. Improving the collection efficiency of the liquid impinger for ultrafine particles and viral aerosols by applying granular bed filtration. Journal of Aerosol Science. 101, 133-143 (2016).
  17. Perez-Mendez, A., et al. Evaluation of a simple and cost effective filter paper-based shipping and storage medium for environmental sampling of F-RNA coliphages. J Virol Methods. 194 (1-2), 60-66 (2013).
  18. Chandler, J. C., et al. Field-based evaluation of a male-specific (F+) RNA coliphage concentration method. Journal of Virological Methods. 239, 9-16 (2017).
  19. Perez-Mendez, A., Chandler, J. C., Bisha, B., Goodridge, L. D. Concentration of enteric viruses from tap water using an anion exchange resin-based method. Journal of Virological Methods. 206, 95-98 (2014).
  20. Perez-Mendez, A., Chandler, J. C., Bisha, B., Goodridge, L. D. Evaluation of an anion exchange resin-based method for concentration of F-RNA coliphages (enteric virus indicators) from water samples. Journal of Virological Methods. 204, 109-115 (2014).
  21. Kammerer, J., Carle, R., Kammerer, D. R. Adsorption and ion exchange: Basic principles and their application in food processing. Journal of Agricultural and Food Chemistry. 59 (1), 22-42 (2011).
  22. Chandler, J. C., et al. A method for the improved detection of aerosolized influenza viruses and the male-specific (F+) RNA coliphage MS2. Journal of Virological Methods. 246, 38-41 (2017).
  23. Friedman, S. D., Cooper, E. M., Calci, K. R., Genthner, F. J. Design and assessment of a real time reverse transcription-PCR method to genotype single-stranded RNA male-specific coliphages (Family Leviviridae). Journal of Virological Methods. 173 (2), 196-202 (2011).
  24. Selvaraju, S. B., Selvarangan, R. Evaluation of three influenza A and B real-time reverse transcription-PCR assays and a new 2009 H1N1 assay for detection of influenza viruses. Journal of Clinical Microbiology. 48 (11), 3870-3875 (2010).
  25. Cademartiri, R., et al. Immobilization of bacteriophages on modified silica particles. Biomaterials. 31 (7), 1904-1910 (2010).
  26. Michen, B., Graule, T. Isoelectric points of viruses. Journal of Appled Microbiology. 109 (2), 388-397 (2010).
  27. Turgeon, N., Toulouse, M. J., Martel, B., Moineau, S., Duchaine, C. Comparison of five bacteriophages as models for viral aerosol studies. Applied and Environmental Microbiology. 80 (14), 4242-4250 (2014).
  28. Vergara, G. G., et al. Evaluation of FRNA coliphages as indicators of human enteric viruses in a tropical urban freshwater catchment. Water Research. 79, 39-47 (2015).
  29. Tung-Thompson, G., Libera, D. A., Koch, K. L., de Los Reyes, F. L., Jaykus, L. A. Aerosolization of a human norovirus surrogate, bacteriophage MS2, during simulated vomiting. PLoS One. 10 (8), e0134277 (2015).

Play Video

記事を引用
Schaeffer, J. W., Chandler, J. C., Davidson, M., Magzamen, S. L., Pérez-Méndez, A., Reynolds, S. J., Goodridge, L. D., Volckens, J., Franklin, A. B., Shriner, S. A., Bisha, B. Detection of Viruses from Bioaerosols Using Anion Exchange Resin. J. Vis. Exp. (138), e58111, doi:10.3791/58111 (2018).

View Video