Stable intravital high-resolution imaging of immune cells in the liver is challenging. Here we provide a highly sensitive and reliable method to study migration and cell-cell-interactions of immune cells in mouse liver over long periods (about 6 hours) by intravital multiphoton laser scanning microscopy in combination with intensive care monitoring.
Liver inflammation as a response to injury is a highly dynamic process involving the infiltration of distinct subtypes of leukocytes including monocytes, neutrophils, T cell subsets, B cells, natural killer (NK) and NKT cells. Intravital microscopy of the liver for monitoring immune cell migration is particularly challenging due to the high requirements regarding sample preparation and fixation, optical resolution and long-term animal survival. Yet, the dynamics of inflammatory processes as well as cellular interaction studies could provide critical information to better understand the initiation, progression and regression of inflammatory liver disease. Therefore, a highly sensitive and reliable method was established to study migration and cell-cell-interactions of different immune cells in mouse liver over long periods (about 6 hr) by intravital two-photon laser scanning microscopy (TPLSM) in combination with intensive care monitoring.
The method provided includes a gentle preparation and stable fixation of the liver with minimal perturbation of the organ; long term intravital imaging using multicolor multiphoton microscopy with virtually no photobleaching or phototoxic effects over a time period of up to 6 hr, allowing tracking of specific leukocyte subsets; and stable imaging conditions due to extensive monitoring of mouse vital parameters and stabilization of circulation, temperature and gas exchange.
To investigate lymphocyte migration upon liver inflammation CXCR6.gfp knock-in mice were subjected to intravital liver imaging under baseline conditions and after acute and chronic liver damage induced by intraperitoneal injection(s) of carbon tetrachloride (CCl4).
CXCR6 is a chemokine receptor expressed on lymphocytes, mainly on Natural Killer T (NKT)-, Natural Killer (NK)- and subsets of T lymphocytes such as CD4 T cells but also mucosal associated invariant (MAIT) T cells1. Following the migratory pattern and positioning of CXCR6.gfp+ immune cells allowed a detailed insight into their altered behavior upon liver injury and therefore their potential involvement in disease progression.
The visualization of cells and cellular functions in whole organs or even whole organisms has been of great interest for more than 50 years, including virtually all parts of the body2. Therefore, some early studies already employed intravital imaging of the liver3,4. However, several limitations exist up to date regarding long term stable high-resolution imaging of liver tissue.
Due to the anatomical position of the liver in close contact with the diaphragm and the gastrointestinal tract5, the most common problem for microscopic intravital imaging is movement due to respiration and, to a lesser extent, peristaltic of the intestinal tract6. In comparison to other solid organs, liver surgery is particularly challenging. Due to the dense microvascular structure, surgical manipulation can lead to massive hemorrhagic lesions, impaired microcirculation7 and also activation of resident immune cells such as Kupffer cells8. Therefore, mechanical fixation of the tissue as published elsewhere6,9 is likely to interfere with the intravital microscopy imaging.
In a healthy liver, 10-15% of the total blood volume resides within the liver vasculature, and the organ receives around 25% of the overall cardiac output10, rendering the organ highly susceptible to changes in the circulation (e.g., blood pressure fluctuations). Therefore, disruptions in the hepatic blood flow due to e.g., shear stress, displacement, injury by excessive tissue handling or centralized circulation will lead to artificial alterations in leukocyte migratory behavior, impaired liver oxygenation and therefore further liver damage, affecting liver immune responses as well as organ preservation and overall life time of the animal.
Early microscopic studies were based on intravital epifluorescence microscopy, but several technical constraints such as photo bleaching and low penetration depth limit the use of this technique for long term liver imaging4,11,12. With the development of multiphoton microscopy in the 1990s, the limitations of photo bleaching or penetration depth were mainly solved, as this new method was technically capable to perform imaging studies in virtually all organs under real life situations13-15. However, the main remaining challenges with respect to liver imaging were: breath movements, autofluorescence of liver tissue, securing unaltered blood flow in the hepatic sinusoids, and especially stable imaging for longer periods of several hr16.
Although several studies addressed the function and migration of various leukocytes in the liver17, e.g., NKT-cells18-20, T cells21,22, liver macrophages23,24 or neutrophils25, long term multiphoton microscopy imaging had not yet been successfully established, a task even more challenging in animals with acute or chronic liver disease due to the existing damage and therefore higher susceptibility to further damage26. However, monitoring migratory behavior and cellular function of leukocytes in the liver in real time allows novel insights in their particular role in liver homeostasis and disease27.
The chemokine receptor CXCR6 is expressed on several lymphocyte subsets, including natural killer (NK) cells, NKT cells and some T cell populations18,28. Prior studies in mice have indicated that CXCR6 and its cognate ligand CXCL16 may control the patrolling of NKT cells on liver sinusoids during homeostasis. Consequently, the use of CXCR6.gfp mice (carrying a knock-in of green fluorescent protein [gfp] in the CXCR6 locus) has been described to investigate the migration of lymphocytes in various organs such as brain29 and also liver18,20, showing increased infiltration of CXCR6.gfp cells upon inflammation.
With the method provided in this study it was possible to follow these processes over a long period of time under stabilized conditions. The intravital multiphoton based procedure allowed imaging that was highly reproducible with minimal perturbation of the animal and the organ; optimized for long-term animal survival by extensive monitoring followed by close control of respiration and circulation; and highly flexible and easy to adopt also to other parenchymal organs such as kidney or spleen.
NOTE: The experiments were performed in accordance with the German legislation governing animal studies following the ‘Guide for the care and use of Laboratory Animals’ (NIH publication, 8th edition, 2011) and the Directive 2010/63/EU on the protection of animals used for scientific purposes (Official Journal of the European Union, 2010). Official permission was granted from the governmental animal care and use office (LANUV Nordrhein-Westfalen, Recklinghausen, Germany).
NOTE: Steps that can be omitted for short term imaging (e.g. snap shots, 3-D stacks or also short duration time-lapse microscopy) are marked with asterisks (*) to reduce preparation time and simplify the surgical protocol. Imaging can also be performed without extensive monitoring and circulation control if necessary, however, survival time will be markedly reduced.
1. Microscope Setup and Pre-surgery Preparation (5-10 min)
2. Tracheotomy (10-15 min)
3. Laparatomy (15-20 min)
4. Sample Setup (10-15 min)
5. Mouse Monitoring
6. Embedding and Tissue Fixation (5-10 min)
7. Imaging
To validate our intravital TPLSM approach, we subjected CXCR6gfp/+ mice to intravital TPLSM imaging. Mice were either left untreated as baseline controls or subjected to a single intraperitoneal injection of carbon tetrachloride (CCl4) to induce acute liver damage20.
Video sequences were taken over a time period of 2-5 hr, and cells were traced over time due to their green fluorescence. To show general cellular motility, all tracks that were detected during the procedure were plotted as a superimposed image (Figure 6A). While cells under baseline conditions showed long distance migration along the liver sinusoids towards the central vein, 18 hr after CCl4 treatment the CXCR6+/gfp cells showed already partially impaired movement patterns. Although some fast moving cells were still present in the liver sinusoids, several focal areas were visible with cells that had changed from random migration to local scanning, indicating a chemotactic response recruiting the cells to the area of injury. The effect was even more pronounced after 36 hr, showing an almost complete arrest of CXCR6+ cells with virtually no active migration. While under baseline conditions most migrating cells had variable migration speeds with random directional changes, CCl4 treated animals showed cells that were only slowly crawling as well as some freely motile cells patrolling the sinusoids after 18 hr but not after 36 hr. Using color-coded migration tracks, cell speed could be visualized directly to assess the effect of the CCl4 treatment. The impaired migration was also visible in the normalized track diagram (Figure 6B), showing that 18 hr after CCl4 the amount of long distance tracks as well as the average track length was markedly reduced, while after 36 hr no motile cells were detectable any more. In line with these findings, the cellular displacement, which describes the ability of a cell to freely patrol the vasculature, decreased over time, indicating a trapping of the cells 36 hr after CCl4 treatment at the site of hepatocellular damage (Figure 6C).
To follow the migratory behavior of CXCR6+/gfp cells in liver in more detail, the migration speed of representative individual cells was plotted to visualize their level of motility over time. We and others previously described several distinct motion patterns of CXCR6+/gfp cells: Active random crawling with a sticking rolling pattern, showing phases of cellular motility and temporal quiescent states; directed cellular recruitment with cells scanning an area of interest but still capable of active crawling; total cellular arrest accompanied by immune cell activation18,20. While mice without treatment mainly showed cells that were freely motile with speeds up to 15 µm/sec, CXCR6+/gfp cells in mice treated with CCl4 displayed markedly reduced cell migration speed and partial arrest already after 18 hr and full migratory arrest after 36 hr (Figure 7A). In line with the single cell analysis, the statistical data of all cells within a sequence revealed decreasing overall migration speed after CCl4 treatment (Figure 7B), which was also resembled by average track speeds (Figure 7C) and track maximum migration speeds (Figure 7D), showing that the approach was suitable to describe differences in cell migration and positioning in developing liver disease.
Figure 1: Tracheotomy of the mouse. (A) Surgical equipment used for preparation. 1x standard pattern forceps, 1x Semken forceps, 1x Dumont No.7 forceps, Graefe forceps (serrated, 2x straight / 1x curved), 2x Blair retractors (4 pronged (blunt)), double ball stylus probe (e.g., Amalgam burnisher 3PL), Heidemann spatula HD2, needle holder (Mathieu or Halsey), 1x small surgical scissors (sharp/blunt, 1xcurved, 1x straight), micro-scissors (e.g., Vannas Spring Scissors), 1x small animal cauter, cotton swabs, eye protective salve, surgical thread, n-Butyl-2-Cyanoacrylatglue. (B) eyes are protected using an eye protective ointment. (C) Initial skin cut for trachea preparation. (D) Dissection of connective tissue between submaxillary salivary glands. (E) Exposition of the trachea. (F) Dissection of the muscular tissue surrounding trachea. (G) Placement of surgical thread underneath trachea for fixation of tube. (H) Tracheal incision using microscissors between upper cartilage rings. (I) Insertion of ventilation tube into trachea. (J) Placement of cranial surgical thread to fix tube to the skin. (K) Double fixation of the tube. (I) Sealing surgical incision using n-Butyl-2-Cyanoacrylat. Please click here to view a larger version of this figure.
Figure 2: Laparatomy and liver preparation. (A) Initial skin incision, blood vessels were cauterized to prevent excessive bleeding. (B) Opening of the peritoneum underneath the sternum. (C) Extension of the peritoneal cut using cautery unit. (D) Sealing of epigastric vessels. (E) Further extension of the peritoneal incision below ribs. (F) Placement of animal into agarose stage dish. (F) Placement of support stacks. (G) Placement of respiratory trigger sensor. (H) Setup of trigger threshold for respiration synchronized imaging. (I) Sternum fixation to retract ribs using surgical thread. (J) Disconnection of the gall bladder from the diaphragm and dissection of the falciform ligament. (K) Placement of staging cover slip. (L) Placement of liver lobe on stage. (M) Placement of coverslip on liver lobe. (N) Placement of i.p. catheter for long term anesthesia. Please click here to view a larger version of this figure.
Figure 3: Intraperitoneal catheter. 27 G needles connected with flexible silicone tubing.
Figure 4: Monitoring of the mouse. (A) Placement of ECG electrodes (green, red, blue cables). Needles for ECG detection are placed subcutaneously as shown. (B) Monitoring of ECG (red), expiratory CO2 (blue) and heart rate (red) showing long term progression (left) and actual measurement (right). (C) Temperature controlled power unit for heat pad control. Temperature is set to 36 °C. Please click here to view a larger version of this figure.
Figure 5: Liver embedding and imaging. (A) Embedding of liver lobe. 3% agarose in PBS is injected at 41 °C under the cover slip using a 2 ml syringe with an 18G needle. (B) Liver lobe is fully embedded in agarose to minimize movement artifacts. (C) Sealing of peritoneum with remaining agarose to prevent dehydration. (D) Removal of agarose covering microscope field of view after full gelatinization. (E) Preparation of viewfield. F Adjustment of Z-level and evaluation of sample blood flow using light microscopy. (D) Cover dish to prevent excessive evaporation. Cover is lifted in the picture to show setup. Please click here to view a larger version of this figure.
Figure 6: Tracking of CXCR6gfp/+ cells in chronic liver damage after CCl4 injection. Mice were injected i.p. with 0.6 ml/kg CCl4 dissolved in sunflower oil 18 hr or 36 hr before imaging. On the day of the experiment, mice were subjected to intravital TPLSM as described. (A) Still images of cell tracking. Tracks from all time points were superimposed to show cellular motility and displacement. Images were taken using a single beam Titan Saphire Laser at 840 nm and a TPLSM microscope. Areas were scanned taking 3-5 Z-stacks with a penetration depth of 70µm with a sampling rate of approximately 30 seconds per scan cycle. Tracks were color coded to show migration speed (light blue: slow moving or sessile cells; purple: motile cells). Scale bars: 100 µm. (B) XY-diagrams of paths normalized for their origin showing track directionality and track length (µm). (C) Total displacement of cells from their origin. Please click here to view a larger version of this figure.
Figure 7: Migration statistics of CXCR6gfp/+ cells followed by intravital TPLSM in liver tissue in baseline and CCl4 treated mice. Cells were analyzed for their migration speed patrolling the liver. (A) Representative speed of single cells followed over time. Speed was measured at each time point and plotted for each frame individually. Lines represent individual cells. Y-axes are scaled according to maximum migration speed. (B) Statistical analysis of A. Frame specific speeds from all cells were grouped and analyzed in baseline and CCl4 treated mice. (C) Average track speed was calculated per track and data from all tracks were grouped for analysis. (D) Maximum speed of each track was plotted and analyzed. All experiments were performed in groups of 3 animals and results were confirmed in two independent experiments. ***P <0.001 (two-tailed unpaired Student t-test). Please click here to view a larger version of this figure.
The aim of our study was to develop a highly standardized, stable and reproducible method for intravital TPLSM imaging of the liver. Intravital imaging in general has given valuable insights into cellular behavior under real life conditions following homing and interaction of different leukocyte populations in development, homeostasis and disease. However, the somewhat challenging anatomical position of the liver, due to which respiratory and peristaltic intestinal movement directly are transmitted to the liver as well as their high fragility compared to other solid organs imposed several challenges for stable long term intravital imaging. Over recent years, many experimental studies in mice have revealed the highly dynamic nature of immune cell infiltration in injured liver28, with major contributions from resident or infiltrating monocytes/macrophages30-32, neutrophils33 or various lymphocyte subsets34,35. However, most of these data were derived from end-point analyses (e.g., multicolor flow cytometry after sacrificing the animals). Up to now only few studies exist describing the dynamics of cellular traffic during liver inflammation using multicolor intravital imaging. Using inverted microscopes circumvents the necessity for fixation and moisturizing of the liver due to the firm adhesion of the tissue to the glass bottom24. However, since many multiphoton microscopes are built as upright imaging systems, more elaborate preparation and fixation methods are needed to stabilize the tissue for the time of imaging. Commonly, custom made staging systems have been described for tissue fixation6, 36,37, however with these it is crucial to validate the liver microcirculation, since even minimal pressure on the tissue affects sinusoidal blood flow with even more severe effects on diseased liver38.
Therefore, the following points were addressed in the setup of this method to optimize the results obtained by in vivo TPLSM imaging: Enhancing the quality of the preparation by minimized sample perturbation and disruption of the microcirculation due to handling issues and increased animal survival; intensive care monitoring and subsequent adaptation of anesthesia, respiration and stabilization of the circulation further enhanced animal survival and minimized physiological artifacts, e.g., caused by imbalances in blood pH. Controlled respiration in combination with triggered imaging was essential to eliminate movement artifacts due to synchronization of the microscope with the respiratory cycles. The embedding of the organ in agarose containing physiological salt concentrations was beneficial to gently fixate the organ after preparation without any further mechanical manipulation and prevented also dehydration of the sample. Most protocols used for liver microscopy provide only insufficient methods for stable, long term anesthesia. However, the survival of the animals could be significantly enhanced with the anesthesia protocol provided here and in combination with the monitoring was sufficient to guarantee survival up to 8 hr. Alternative methods are generally suitable to visualize processes within a time period of up to 3 hours such as neutrophil invasion39, but lack the possibility to image longer lasting processes such as monocyte or lymphocyte invasion22 or even cell proliferation6. Understanding the dynamics of recruitment, infiltration and cellular interaction during acute and chronic liver inflammation can provide more detailed insight into the development and progression of liver disease. By using this enhanced understanding of the immunopathology it will be possible to design therapies much more refined in terms of addressing the target cells of interest rather than using e.g. non-selective immunosuppressive approaches.
To address the positioning, transmigration and interaction of leukocytes, high quality images are needed for accurate 4D tracking of the cells within the liver vasculature and liver tissue18,20,40.
The method we provide here can be applied using common laboratory reagents and equipment, making it both easy to handle and cost efficient with minimal perturbation of the sample. To maintain the physiological conditions of the mouse for as long as possible, it is necessary to fine-adjust the respiratory volume and frequency to control oxygenation and blood CO2 levels. Although due to the continuous infusion of liquids into the peritoneum there is at least a tentative supply to stabilize the circulation, ECG and heart frequency measurements only allow a partial control regarding stabilization of the circulation. By implementing direct blood pressure control and central venous liquid application it is likely that the vital parameters can be stabilized even more, leading to further enhancement of stability and survival.
Even under highly controlled conditions, imaging of animals which have been subjected to liver damage models commonly used in mice such as acetaminophen induced liver damage, CCl4 induced liver damage or dietary induced fatty liver disease remains challenging. Due to the essential function of the liver in metabolic state control and its central position in the circulation, alterations of the liver functionality or microcirculation directly impacts long-term survival of the animals, therefore limiting the possibility to obtain long TPLSM video-sequences of heavily damaged organs, e.g. with severe hemorrhages or destroyed microvasculature. Also, in severely altered liver microanatomy as in models with extensive necroses, it remains difficult to study cell-cell-interactions and local compartmentalization of inflammatory cell aggregates, because no standardized “counter-staining” for anatomical structures (such as hematoxylin-staining in conventional microscopy or DAPI staining in immunofluorescence) is available for intravital TPLSM.The quality of the data obtained by the imaging process further depends on the labeling intensity of the cells and the microscopic setup.
Several approaches exist to visualize GFP+ cells in liver. The highest fluorescence with very low background fluorescence is obtained between 900 and 920 nm excitation wavelength. The almost complete loss of liver background fluorescence does not allow investigating the positioning of the cells within the liver, when not using additional vessel trackers such as Dextran or Lectin. Therefore, we decided to image the migrating leukocytes at a wavelength of 840 nm, giving the best ratio between the GFP signal and detailed but not too bright liver background fluorescence.
Taken together, the intravital TPLSM imaging system introduced in this study can be applied to a broad variety of liver specific intravital microscopy questions. With this approach, TPLSM imaging in other solid organs such as kidney, liver, bladder, gut or pancreas is feasible with only minor modifications of the surgical procedures and tissue staging, therefore providing a highly flexible approach to investigate long term migratory processes of cells in vivo.
The authors have nothing to disclose.
The authors thank the Central Animal facility of the University Hospital Aachen for technical support. This work was supported by the German Research Foundation (DFG Ta434/2-1, DFG SFB/TRR 57) and by the Interdisciplinary Center for Clinical Research (IZKF) Aachen. This work was further supported by the Core Facility ”Two-Photon Imaging”, a Core Facility of the Interdisciplinary Center for Clinical Research (IZKF) Aachen within the Faculty of Medicine at RWTH Aachen University.
Anesthetics | |||
Buprenorphine | Essex Pharma | 997.00.00 | Analgeticum, 0.1 mg/kg |
Fentanyl | Rotex Medica | charge: 30819 | |
Fluovac anesthesia system | Harvard Apparatus | 34-1030 | |
Glucose 5% | Braun | ||
ISOFLO (Isoflurane Vapor) vaporiser | Eickemeyer | 4802885 | |
Isoflurane | Forene Abbott | B 506 | |
Isotonic (0.9%) NaCl solution | DeltaSelect GmbH | PZN 00765145 | |
Ketamin 10% | ceva | Charge: 36217/09 | |
Xylazin 2% | medistar | Charge: 04-03-9338/23 | |
Consumable supplies | |||
20ml Syringe | BD Plastipak | ||
250ml Erlenmeyer flask | Schott Duran | 21 226 36 | |
25mL Beaker 2x | Schott Duran | 50-1150 | |
2ml syringe | BD Plastipak | ||
4-0 Vicryl suture | Ethicon | V7980 | |
Agarose | commercially available | ||
Bepanthen Eye and Nose ointment | Bayer Vital GmbH | 6029009.00.00 | |
Change-A-Tip Deluxe High-Temp Cautery Kit | Fine Science Tools Inc. | 18010-00 | |
Cotton Gauze swabs | Fuhrmann GmbH | 32014 | |
Cover Slip 24x50mm | ROTH | 1871 | |
Durapore silk tape | 3M | 1538-1 | |
Feather disposable scalpel | Feather | 02.001.30.011 | |
Fine Bore Polythene Tubing 0,58mm ID | Smiths medical | 800/100/200 | |
Histoacryl | Braun | 1050052 | 5x 0,5ml |
Leukoplast | BSN Medical Inc. | ||
Microscope Slides | ROTH | 1879 | |
Poly-Alcohol Haut…farblos Antisepticum | Antiseptica GmbH | 72PAH200 | |
Sterican needle 18 G x 1 | B. Braun | 304622 | |
Sterican needle 27 3/4 G x 1 | B. Braun | 4657705 | |
Tissue paper | commercially available | ||
Surgical Instruments | |||
Amalgam burnisher 3PL | Gatz | 0110? | |
Blair retractors (4 pronged (blunt)) x2 | Storz&Klein | S-01134 | |
Dumont No.7 forceps | Fine Science Tools Inc. | 91197-00 | |
Graefe forceps curved x1 | Fine Science Tools Inc. | 11151-10 | |
Graefe forceps straight x2 | Fine Science Tools Inc. | 11050-10 | |
Heidemann spatula HD2 | Stoma | 2030.00 | |
Needle holder Mathieu | Fine Science Tools Inc. | 12010-14 | |
Scissor | Fine Science Tools Inc. | 14074-11 | |
Semken forceps | Fine Science Tools Inc. | 11008-13 | |
Small surgical scissors curved | Fine Science Tools Inc. | 14029-10 | |
Small surgical scissors straight | Fine Science Tools Inc. | 14028-10 | |
Standard pattern forceps | Fine Science Tools Inc. | 11000-12 | |
Vannas spring scissors | Fine Science Tools Inc. | 15000-08 | |
Equipment | |||
ECG Trigger Unit | Rapid Biomedical | 3000003686 | |
MICROCAPSTAR End-Tidal Carbon Dioxide Analyzer | AD Instruments | ||
Minivent Typ 845 | Harvard Apparatus | 73-0043 | |
Multiphoton microscope Trimscope I | LaVision | ||
Perfusor Compact | B. Braun | ||
PowerLab 8/30 8 channel recorder | AD Instruments | PL3508 | |
Temperature controlled heating pad | Sygonix | 26857617 | |
Temperature sensor | comercially available | ||
Temperature controlled System for Microscopes -Cube&Box | Life Imaging Services |