Source: Chintalapudi, S. R., et al. Isolation of Primary Murine Retinal Ganglion Cells (RGCs) by Flow Cytometry. J. Vis. Exp. (2017)
This video demonstrates the procedure for isolating murine primary retinal ganglion cells (RGCs) by using flow cytometry. This method allows for the future study of RGCs, with the goal of better understanding the major decline in visual acuity that results from the loss of functional RGCs in neurodegenerative diseases.
All procedures involving animal samples have been reviewed and approved by the appropriate animal ethical review committee.
1. Preparation of Instruments, Solutions, and Media
Note: All information about materials, reagents, tools, and instruments reported in the protocol are specified in the Table of Materials.
2. Preparation of the Retinal Cell Suspension
3. Immunolabeling the Retinal Cells
The authors have nothing to disclose.
Anti-mouse CD15 PE | BioLegend | 125606 | Clone MC-480 |
Anti-mouse CD48 PE-Cy7 | BioLegend | 103424 | Clone HM48-1 |
Anti-mouse CD57 | Sigma Aldrich | C6680-100TST | Clone VC1.1 |
Anti-mouse CD90.2 AF700 | BioLegend | 105320 | Clone 30-H12 |
Brilliant Violet 421 Goat Anti-mouse IgG | BioLegend | 405317 | Clone Poly4053 |
Purified Anti-mouse CD16/32 | BioLegend | 101302 | FcgRII/III block, Clone 93 |
Fetal Bovine Serum | Hyclone | SH30071.03 | U.S. origin |
AbC Total Antibody Compensation Bead Kit | Thermo Fisher Scientific | A10497 | Multi-species Ig |
Neurobasal Medium | Thermo Fisher Scientific | 21103049 | Add serum to media prior to culture. |
Phosphate-Buffered Saline (PBS) | Thermo Fisher Scientific | 10010049 | Saline solution |
Dissection Microscope | Olympus | SZ-PT Model | Stereo Microscope |
Sorvall Centrifuge | Thermo Scientific | ST 16R | All centrifugation performed at RT |
Base Plate – Dissection Pan | Fisher Scientific | SB15233FIM | A wax plate can also be used |
Forceps | Aesculap | 5002-7 | 4 ½ inches |
Iris Scissors, Straight | Aesculap | 1360 | 5 ½ inches |
Falcon 15 mL conical tubes | Fisher Scientific | 352097 | Polypropylene tubes |
Falcon 50 mL conical tubes | Fisher Scientific | 352098 | Polypropylene tubes |
BD FACS Tubes | Fisher Scientific | 352003 | Polypropylene tubes |
40 mm dishes | MidSci | TP93040 | Tissue culture treated |
70 μm nylon strainer | MidSci | 70ICS | sterile |
40 μm nylon strainer | MidSci | 40ICS | sterile |
BD 10 mL syringe | Fisher Scientific | 301604 | Disposable Syringe without needle |
Pestles | MidSci | PEST | sterile |
Wheaton Vials | Fisher Scientific | 986734 | No Liner |
BD 30 G needle | Fisher Scientific | 305128 | 1 inch |
Hausser Scientific Bright-Line Glass Counting Chamber | Fisher Scientific | 0267151B | Hemocytometer |
Gibco Trypan blue 0.4% Solution | Fisher Scientific | 15250061 | Viability Dye |
Eppendorf tubes | Fisher Scientific | 05-402-25 | 1.5mL |
EVOS Floid Cell Imaging | Thermo Fisher Scientific | 447113 | Fluorescence Imaging with a 20x objective |
100% Ethanol | Fisher Scientific | 04-355-452 | Used to make 70% Ethanol |
Pipet-Lite LTS Pipette L-1000XLS+ | Rainin | 17014282 | LTS Pipette |
Pipet-Lite LTS Pipette L-200XLS+ | Rainin | 17014391 | LTS Pipette |
Pipet-Lite LTS Pipette L-20XLS+ | Rainin | 17014392 | LTS Pipette |
Rack LTS 1000 mL – GPS-L1000S | Rainin | 17005088 | Blue Rack Sterile Tips |
Rack LTS 250 mL – GPS-L250S | Rainin | 17005092 | Green Rack Sterile Tips |
Rack LTS 20 mL – GPS-L10S | Rainin | 17005090 | Red Rack Sterile Tips |
FACSAria II Cell Sorter | BD Biosciences | N/A | Custom order |
LSR II Cytometer | BD Biosciences | N/A | Custom order |