We introduce a method for quantifying Stentor habituation using a microcontroller board-linked apparatus that can deliver mechanical pulses at a specified force and frequency. We also include methods for assembling the apparatus and setting up the experiment in a way that minimizes external perturbations.
Learning is usually associated with a complex nervous system, but there is increasing evidence that life at all levels, down to single cells, can display intelligent behaviors. In both natural and artificial systems, learning is the adaptive updating of system parameters based on new information, and intelligence is a measure of the computational process that facilitates learning. Stentor coeruleus is a unicellular pond-dwelling organism that exhibits habituation, a form of learning in which a behavioral response decreases following a repeated stimulus. Stentor contracts in response to mechanical stimulation, which is an apparent escape response from aquatic predators. However, repeated low-force perturbations induce habituation, demonstrated by a progressive reduction in contraction probability. Here, we introduce a method for quantifying Stentor habituation using a microcontroller board-linked apparatus that can deliver mechanical pulses at a specified force and frequency, including methods for building the apparatus and setting up the experiment in a way that minimizes external perturbations. In contrast to the previously described approaches for mechanically stimulating Stentor, this device allows the force of stimulation to be varied under computer control during the course of a single experiment, thus greatly increasing the variety of input sequences that can be applied. Understanding habituation at the level of a single cell will help characterize learning paradigms that are independent of complex circuitry.
Learning is usually associated with a complex nervous system, but there is increasing evidence that life at all levels, down to single cells, can display intelligent behaviors. In both natural and artificial systems, learning is the adaptive updating of system parameters based on new information1, and intelligence is a measure of the computational process that facilitates learning2.
Stentor coeruleus is a unicellular pond-dwelling organism that exhibits habituation, a form of learning in which a behavioral response decreases following a repeated stimulus3. Stentor contracts in response to mechanical stimulation3, which is an apparent escape response from aquatic predators. However, repeated low-force perturbations induce habituation, demonstrated by a progressive reduction in contraction probability3. The habituated Stentor still contracts after receiving high-force mechanical stimulation4 or photic stimulation5. These observations, which align with Thompson and Spencer's classic criteria for habituation in animals6, strongly suggest that the original contractile response decrement is due to learning rather than fatigue or ATP depletion. As a free-living cell, Stentor can be studied without much interference from surrounding cells, as would be the case in a multicellular tissue. Several additional features make Stentor a tractable system for studying learning: its large size (1 mm), its quantifiable habituation response3, the ease of injection and micromanipulation7, the fully sequenced genome8, and the availability of RNA interference (RNAi) tools9. Using this model organism to explore cell learning without a brain or nervous system requires a reproducible procedure for stimulating Stentor cells and measuring the response.
Here, we introduce a method for quantifying Stentor habituation using a microcontroller board-linked apparatus that can deliver mechanical pulses at a specified force and frequency, including methods for building the apparatus and setting up the experiment in a way that minimizes external perturbations (Figure 1). Understanding habituation at the level of a single cell will help characterize learning paradigms that are independent of complex circuitry.
Figure 1: Habituation experiment setup. The Petri plate containing Stentor is placed atop the flexible metal ruler of the habituation device. The armature of the habituation device then hits the metal ruler at a specified force and frequency, producing a stimulus wave across the field of cells. The USB microscope camera records the responses of the Stentor to the stimulation. Please click here to view a larger version of this figure.
Figure 2: Summary of the habituation experiment workflow. The figure shows the basic steps involved in studying Stentor using the habituation device. The figure was created with BioRender.com. Adapted from "Process Flowchart", by BioRender.com (2022). Retrieved from https://app.biorender.com/biorender-templates. Please click here to view a larger version of this figure.
NOTE: A summary of the habituation experiment workflow is shown in Figure 2.
1. Assembling the habituation device
Figure 3: Components of the habituation device. All the labeled electronics are required to assemble the machine. Please click here to view a larger version of this figure.
Figure 4: Electronics schematic. This is the circuit on the breadboard. The wires connecting to the microcontroller board are numbered as described in the protocol. D1 and D2 are the red and green LEDs, respectively, and are connected to ground through 330 Ω resistors. The two switches are pulled up with 10 KΩ resistors. Please click here to view a larger version of this figure.
2. Setting up the habituation experiment
3. Analyzing the experiment video
Figure 5: Stentor contracting after receiving a mechanical stimulus. (A) The Stentor are in their elongated state and anchored to the bottom of the Petri plate. (B) The Stentor have contracted after receiving a Level 4 mechanical stimulation from the habituation device. The images were taken with a USB microscope. Please click here to view a larger version of this figure.
Video 1: Video of Stentor contracting. The Stentor receive a Level 4 mechanical stimulus from the habituation device every minute. These cells have not yet habituated, so they contract after receiving the pulse. The cells are in the Petri plate placed atop the habituation device. Please click here to download this Video.
The method described above, using the Level 4 mechanical pulse at a frequency of 1 tap/min, should result in a progressive reduction in the contraction probability of the Stentor within 1 h. This is indicative of habituation (see Figure 6, Video 2).
Figure 6: Baseline habituation. The contraction probability of Stentor progressively declines over the course of 1 h after receiving Level 4 mechanical pulses at a frequency of 1 tap/min (n = 22-27). Please click here to view a larger version of this figure.
Video 2. Video of habituated Stentor. The cells receive a Level 4 mechanical stimulus after 1 h of receiving mechanical pulses of the same force at a frequency of 1 tap/min. Most of the cells have habituated to the stimuli during the hour and, thus, do not contract. Please click here to download this Video.
Altering the force and/or frequency of the mechanical pulse delivery can change the Stentor habituation dynamics. For example, using the Level 2 pulse at a frequency of 1 tap/min precludes habituation over the course of 1 h (see Figure 7). A Level 5 pulse should elicit contractions in few to zero Stentor.
Figure 7: Lack of habituation within 1 h for stronger forces. The contraction probability of Stentor does not appreciably decline over the course of 1 h after receiving Level 2 mechanical pulses at a frequency of 1 tap/min (n = 7-33). Please click here to view a larger version of this figure.
The most critical steps in the protocol relate to ensuring that the Stentor remain in optimal conditions for contractions to occur. The contraction response in the habituation assay requires that Stentors are anchored to a surface using their sticky holdfast since they rarely contract when they are freely swimming. However, the bottom surface of the 35 mm Petri plate used for habituation experiments is not typically conducive for anchoring unless coated with poly-ornithine. Furthermore, the Stentor cannot be exposed to any mechanical perturbation for a minimum of 2 h before the start of the habituation experiment because the Stentor forgetting timescale is 2-6 h3. If Stentor receive mechanical stimulation within 2 h of the habituation experiment start time, there is a possibility that this prior stimulation will induce a slight level of habituation in advance of the experiment, thereby reducing the contraction probability after the habituation device delivers the first mechanical pulse. Finally, during the analysis stage, it is important to only count the number of Stentor that contract after a pulse – rather than any incidental spontaneous contractions that occur prior to the pulse delivery – to obtain an accurate readout of the fraction of cells that contracted in response to the mechanical stimulation.
The protocol can be readily modified to study different types of habituation dynamics by changing the force and frequency of the mechanical pulses delivered by the habituation device. This also provides an opportunity to explore other types of learning, such as sensitization, that might occur in Stentor. The microcontroller board program code itself can also be adjusted to deliver different patterns of mechanical taps to the Stentor.
One potential issue to troubleshoot with this protocol is the low frequency of Stentor anchoring, which could constrain the number of Stentor that can be observed in the habituation experiment. Anchoring frequency is sometimes reduced in Stentor cultures that have not recently been fed or are contaminated. To address this problem, one should wash a fresh batch of Stentor to start a new culture and feed them regularly according to the protocol described in Lin et al.10.
This protocol is limited in that only a single plate of Stentor can be tested at a time, resulting in relatively low-throughput measurements. Furthermore, current software does not allow for the automation of single-cell image analysis. Most data acquired are, therefore, on a population level. Future models of the habituation device and image analysis tools may facilitate high-throughput single-cell experiments.
Habituation in Stentor has been previously studied using methods described by Wood3, but this new protocol allows experiments to be automated. Automation not only allows the researcher to reproducibly deliver mechanical pulses of a specified force and frequency but also facilitates long-term habituation experiments since the device can be left running without supervision for days. Furthermore, using a stepper motor rather than the solenoid employed in Wood's experiments3 reduces the risk of demagnetization over time and also allows the strength of the stimulus to be varied during the course of a single experiment.
Studying cellular habituation may reveal clinical insights for conditions such as attention-deficit/ hyperactivity disorder (ADHD) and Tourette's syndrome in which habituation is impaired11. Stentor habituation mechanisms may also unveil new non-synaptic learning paradigms independent of complex cellular circuitry. Finally, insights about single-cell learning could inspire methods for reprogramming cells within multicellular tissues – another potential avenue to fight disease.
The authors have nothing to disclose.
We thank Tatyana Makushok for innumerable discussions about Stentor learning. This work was funded by NSF grant MCB- 2012647 and by NIH grant R35 GM130327, as well as by the I2CELL award from the Foundation Fourmentin-Guilbert.
0.01% Poly-ornithine | Millipore Sigma | P4957 | Used to coat Petri plate |
35-mm Petri plate | Benz Microscope Optics Center Inc. | L331 | Contains Stentor during experiments |
6-well plate | StemCell Technologies | 38016 | Used to wash Stentor |
Aluminum breadboard, 4" x 24" x 1/2" (x1) | Thorlabs | MB424 | Used to construct habituation device |
Big easy driver stepper motor driver board (x1) | Sparkfun | ROB-12859 | Used to construct habituation device |
Construction rail, 1" x 5'' (x2) | Newport | Newport CR-1 | Used to construct habituation device |
Laptop | Apple Store | https://www.apple.com/macbook-air-m1/ | Connect laptop to USB microscope to visualize experiments |
Large right-angle bracket (x1) | Thorlabs | AP90RL | Used to construct habituation device |
Microcontroller board | Arduino | A000066 | Used to control habituation device |
Nema 17 Stepper Motor Bipolar 59Ncm 2A 84oz.in 48mm 4-Lead | Stepperonline.com | 5-17HS19-2004S1 | Used to construct habituation device |
Pasteurized spring water | Carolina | 132458 | Media for Stentor experiments |
Right-angle bracket (x3) | Thorlabs | AP90 | Used to construct habituation device |
Stemi 2000 stereo microscope | Zeiss | Used to visualize Stentor during wash steps | |
Stentor coeruleus | Carolina | 131598 | These are the cells used for habituation experiments |
USB microscope | Celestron | 44308 | Used to visualize and record experiments |
Webcam recorder | Apple Store | https://apps.apple.com/us/app/webcam-recorder/id1508067444?mt=12 | Install this application to take videos of experiments |