We present a protocol using liquid chromatography coupled with tandem mass spectrometry to identify and quantify major cellular lipids in Saccharomyces cerevisiae. The described method for a quantitative assessment of major lipid classes within a yeast cell is versatile, robust, and sensitive.
Lipids are structurally diverse amphipathic molecules that are insoluble in water. Lipids are essential contributors to the organization and function of biological membranes, energy storage and production, cellular signaling, vesicular transport of proteins, organelle biogenesis, and regulated cell death. Because the budding yeast Saccharomyces cerevisiae is a unicellular eukaryote amenable to thorough molecular analyses, its use as a model organism helped uncover mechanisms linking lipid metabolism and intracellular transport to complex biological processes within eukaryotic cells. The availability of a versatile analytical method for the robust, sensitive, and accurate quantitative assessment of major classes of lipids within a yeast cell is crucial for getting deep insights into these mechanisms. Here we present a protocol to use liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) for the quantitative analysis of major cellular lipids of S. cerevisiae. The LC-MS/MS method described is versatile and robust. It enables the identification and quantification of numerous species (including different isobaric or isomeric forms) within each of the 10 lipid classes. This method is sensitive and allows identification and quantitation of some lipid species at concentrations as low as 0.2 pmol/µL. The method has been successfully applied to assessing lipidomes of whole yeast cells and their purified organelles. The use of alternative mobile phase additives for electrospray ionization mass spectrometry in this method can increase the efficiency of ionization for some lipid species and can be therefore used to improve their identification and quantitation.
A body of evidence indicates that lipids, one of the major classes of biomolecules, play essential roles in many vital processes within a eukaryotic cell. These processes include the assembly of lipid bilayers that constitute the plasma membrane and membranes surrounding cellular organelles, transport of small molecules across cell membranes, response to changes in the extracellular environment and intracellular signal transduction, generation and storage of energy, import and export of proteins confined to different organelles, vesicular trafficking of proteins within the endomembrane system and protein secretion, and several modes of regulated cell death1,2,3,4,5,6,7,8,9,10.
The budding yeast S. cerevisiae, a unicellular eukaryotic organism, has been successfully used to uncover some of the mechanisms underlying the essential roles of lipids in these vital cellular processes4,5,6,7,8,9,10,11,12,13,14,15,16,17,18,19,20. S. cerevisiae is a valuable model organism for uncovering these mechanisms because it is amenable to comprehensive biochemical, genetic, cell biological, chemical biological, system biological, and microfluidic dissection analyses21,22,23,24,25. Further progress in understanding mechanisms through which lipid metabolism and intracellular transport contribute to these vital cellular processes requires sensitive mass spectrometry technologies for the quantitative characterization of the cellular lipidome, understanding the lipidome molecular complexity, and integrating quantitative lipidomics into a multidisciplinary platform of systems biology1,2,3,26,27,28,29,30.
Current methods for the mass spectrometry-assisted quantitative lipidomics of yeast cells and cells of other eukaryotic organisms are not sufficiently versatile, robust, or sensitive. Moreover, these currently used methods are unable to differentiate various isobaric or isomeric lipid species from each other. Here we describe a versatile, robust, and sensitive method that allows use of liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) for quantitative analysis of major cellular lipids of S. cerevisiae.
1. Preparation of sterile media for culturing yeast
2. Yeast strain
3. Culturing yeast in the complete YP medium with glucose
4. Transferring yeast to and culturing them in the synthetic minimal YNB medium with glucose
5. Preparation of reagents, labware and equipment for lipid extraction
6. Preparation of reagents, labware, and equipment for LC
7. Lipid extraction from yeast cells
8. Separation of extracted lipids by LC
9. Mass spectrometric analysis of lipids separated by LC
10. Identification and quantitation of different lipid classes and species by processing of raw data from LC-MS/MS
Our method for a quantitative assessment of major cellular lipids within a yeast cell with the help of LC-MS/MS was versatile and robust. It allowed us to identify and quantify 10 different lipid classes in S. cerevisiae cells cultured in the synthetic minimal YNB medium initially containing 2% glucose. These lipid classes include free (unesterified) fatty acids (FFA), CL, phytoceramide (PHC), phytosphingosine (PHS), PC, PE, PG, PI, PS, and TAG (Supplemental Table 1). Numerous molecular species of each of these classes were identified and quantified using this LC-MS/MS method (Supplemental Table 1).
Our LC-MS/MS method was also sensitive. Indeed, it enabled the identification and quantitation of molecular species of lipids at concentrations as low as 0.165 pmol/µL (see data for phytoceramide in Table 5). This limit of quantitation differs for different lipid classes within a wide range of concentrations (Table 5).
Importantly, our method allowed identification and quantification of different isobaric or isomeric forms of lipids. Isobaric forms of lipids are lipid species with the same nominal mass (ie., sum of the masses of the most abundant isotopes) but differing exact masses31. Isomeric forms of lipids are lipid species with the same molecular formula but with different chemical structure31. For example, the use of our LC-MS/MS method distinguished between PHC (16:0_26:0) and the isobaric lipid species PC (16:0_10:0): although they have the same nominal mass value of 650, their exact masses are 650.6457 and 650.4755, respectively. Moreover, this LC-MS/MS method distinguished between two pairs of isomeric lipid species with the same molecular formula but different chemical structure: 1) PC (18:0_18:1) and PC (20:0_16:1), with molecular formula (C44H87N1O8P1) and exact mass (788.6163); and 2) PE (16:0_16:0) and PE (14:0_18:0), with the molecular formula (C37H75N1O8P1) and exact mass (692.5224).
Our LC-MS/MS method can be used to increase the efficiency of ionization for lipids of all classes, thus improving the identification and quantitation of major cellular lipids. Such improvement can be achieved by using alternative mobile phase additives for the ESI MS (Table 6). These alternative phases include ammonium formate, ammonium formate with formic acid, ammonium acetate, ammonium acetate with acetic acid, and ammonium acetate with formic acid. Each of these alternative mobile phase additives can be used for both the normal-phase and reverse-phase LC columns (Table 6).
Another advantage of our LC-MS/MS method consists in the ability to use two different methods for the fragmentation of precursor ions (MS1) of lipids into MS2 products. These two methods are high-energy collisional dissociation (HCD) and collision-induced dissociation (CID)32. We found that the CID method is beneficial if used in combination with the ammonium acetate mobile phase additive for the ESI (-) mode of MS, as under these conditions it allows an increase in the efficiency of MS1 lipid ion fragmentation into MS2 products for PHC, CL, FFA, PE, PG, PI, and PS (Table 7). In contrast, the HCD method is favorable if used in combination with the ammonium formate mobile phase additive for the ESI (+) mode of MS, as under these conditions it enables an increase in the efficiency of MS1 lipid ion fragmentation into MS2 products for PC, PHS and TAG (Table 8).
Figure 1: The total ion chromatogram (TIC) from liquid chromatography/mass spectrometry (LC/MS) data of lipids that were extracted from cells of the wild type strain BY4742. The TIC of lipids separated by LC on a reverse-phase column CSH C18 and detected by MS of parent ions that were created using the negative electrospray ionization mode. Please click here to view a larger version of this figure.
Figure 2: A chromatogram of two isomeric phosphatidylserine forms (34:0) that have the same m/z value (M-H) of 762.5294 but different retention times of 7.65 min and 8.49 min. The lipids were extracted from cells of the wild type strain BY4742 and separated by liquid chromatography on a reverse-phase column CSH C18. Please click here to view a larger version of this figure.
Figure 3: MS1 spectra of two isomeric phosphatidylserine species (34:0) that have the same m/z value (M-H) of 762.5294 but different retention times of 7.65 min and 8.49 min. The lipids were extracted from cells of the wild type strain BY4742, separated by liquid chromatography on a reverse-phase column CSH C18 (as shown in Figure 2) and detected by mass spectrometry of parent (MS1) ions that were created using the negative electrospray ionization mode. (A) The MS1 spectrum of a phosphatidylserine form (34:0) with the m/z value (M-H) of 762.5294 and the retention time of 7.65 min. (B) The MS1 spectrum of a phosphatidylserine form (34:0) with the m/z value (M-H) of 762.5294 and the retention time of 8.49 min. Please click here to view a larger version of this figure.
Figure 4: MS2 spectra of two isomeric phosphatidylserine species (34:0) that have the same m/z value (M-H) of 762.5294 but different retention times of 7.65 min and 8.49 min. The lipids were extracted from cells of the wild type strain BY4742, separated by liquid chromatography on a reverse-phase column CSH C18 (as shown in Figure 2) and detected by mass spectrometry of MS1 ions (as shown in Figure 3). Secondary ions (MS2) were then detected by mass spectrometry. (A) The MS2 spectrum of a phosphatidylserine form (34:0) with the m/z value (M-H) of 762.5294 and the retention time of 7.65 min. The loss of a serine moiety produced an ion with the m/z value (M-H) of 675.6149. (B) The MS2 spectrum of a phosphatidylserine form (34:0) with the m/z value (M-H) of 762.5294 and the retention time of 8.49 min. The loss of a serine moiety produced an ion with the m/z value (M-H) of 675.8843. Please click here to view a larger version of this figure.
Detection mode | Lipid class | Hydrophobic tail composition | Calculated m/z value | Concentration (pmoles/µl) |
Negative | Ceramide | 18:1_17:0 | 550.5204675 | 226 |
Negative | Cardiolipin | 14:0_14:0_14:0_14:0 | 1239.839755 | 196 |
Negative | Free fatty acid | 19:0 | 297.2799035 | 837 |
Negative | Phosphatidylethanolamine | 15:0_15:0 | 662.4766305 | 377 |
Negative | Phosphatidylglycerol | 15:0_15:0 | 693.4712115 | 349 |
Negative | Phosphatidylinositol | 17:0_20:4 | 871.5342065 | 3 |
Negative | Phosphatidylserine | 17:0_17:0 | 762.5290605 | 318 |
Positive | Phosphatidylcholine | 13:0_13:0 | 650.4755335 | 385 |
Positive | Phytosphingosine | 16:1 | 272.2584055 | 225 |
Positive | Triacylglycerol | 28:1_10:1_10:1 | 818.7232155 | 367 |
Table 1: The composition of a mixture of internal lipid standards. Internal lipid standards were prepared in chloroform/methanol (2:1) mixture. Detection mode refers to a positive or negative mode of parent ions detection using an Orbitrap Velos Mass Spectrometer equipped with electrospray ionization (ESI) ion source. The calculated m/z values are for the adducts of lipids.
FTMS + p resolution | 60000 |
Mass range (dalton) | 150-2000 |
Ion source type | HESI |
Capillary temperature (°C) | 300 |
Source heater temperature (°C) | 300 |
Sheath gas flow | 10 |
Aux gas flow | 5 |
Positive polarity voltage (kV) | 3 |
Negative polarity voltage (kV) | 3 |
Source current (µA) | 100 |
Table 2: The Orbitrap Velos Mass Spectrometer's settings used to analyze lipids that were separated by LC. Abbreviations: FTMS + p = Fourier transform-based mass spectrometry in the ESI (+) mode; HESI = heated electrospray ionization.
Instrument polarity | Positive | Negative |
Activation type | High-energy-induced-collision-dissociation | Collision-induced-dissociation |
Minimal signal required | 5000 | 5000 |
Isolation width | 2 | 2 |
Normalized collision energy | 55 | 35 |
Default charge state | 2 | 2 |
Activation time | 0.1 | 10 |
FTMS + C resolution | 7500 | |
5 most intense peaks were selected for ms/ms |
Table 3: The Orbitrap Velos Mass Spectrometer's settings used to detect secondary ions (MS2). Abbreviation: FTMS + C = Fourier transform-based mass spectrometry in the ESI (+) mode.
Identification | |
Database | Orbitrap |
Peak detection | Recall isotope (ON) |
Search option | Product search Orbitrap |
Search type | Product |
Experiment type | LC-MS |
Precursor tolerance | 10 ppm |
Product tolerance | High-energy-induced-collision-dissociation [ESI (+) mode]: 20 ppm |
Collision-induced-dissociation [ESI (-) mode]: 0.5 Daltons | |
Quantitation | |
Execute quantitation | ON |
m/z tolerance | -5.0; +5.0 |
Tolerance type | ppm |
Filter | |
Top rank filter | ON |
Main node filter | Main isomer peak |
m-score threshold | 5 |
c-score threshold | 2 |
FFA priority | ON |
ID quality filter | A: Lipid class & all fatty acids are completely identified |
B: Lipid class & some fatty acids are identified | |
C: Lipid class or FA are identified | |
D: Lipid identified by other fragment ions (H2O, etc.) | |
Lipid Class | |
High-energy-induced-collision-dissociation [ESI (+) mode] | PC, TAG |
Collision-induced-dissociation [ESI (-) mode] | CER, CL, FFA, PE, PG, PI, PS |
Ions | |
High-energy-induced-collision-dissociation [ESI (+) mode] | + H; + NH4; + Na |
Collision-induced-dissociation [ESI (-) mode] | – H; – 2H; – HCOO |
Table 4: The search parameters used to identify different lipid classes and species with the help of the Lipid Identification software "Lipid Search" (V 4.1). Abbreviations: CER = ceramide; CL = cardiolipin; FFA = free (unesterified) fatty acid; PC = phosphatidylcholine; PE = phosphatidylethanolamine; PG = phosphatidylglycerol; PI = phosphatidylinositol; PS = phosphatidylserine; TAG = triacylglycerol.
Table 5: The lowest concentrations of molecular species of different lipid classes that can be identified and quantitated with the help of our LC-MS/MS method. An estimate of the lowest quantifiable concentration for each lipid class is based on the MS peak areas for its internal standard (these MS peak areas and lipid standard concentrations are displayed in bold) and its representative molecular form present at the lowest detectable concentration. Data are presented as mean values of two independent experiments, for each of which three technical replicates were performed. Please click here to view this table (Right click to download).
Lipid standard | ESI mode | AmF | AmF/FA | AmAc | AmAc/AA | AmAc/FA |
PHC | – | 74 | 75.2 | 85.8 | 77 | 74.8 |
CL | – | 72.9 | 75.1 | 78.3 | 68.4 | 74 |
FFA | – | 77.1 | 77.2 | 75.5 | 84 | 72.9 |
PE | – | 98 | 96 | 95 | 91.5 | 86 |
PG | – | 64 | 45.1 | 75.9 | 60.5 | 55 |
PI | – | 79.3 | 76 | 82.5 | 80.3 | 77 |
PS | – | 73.7 | 61.6 | 85.8 | 81.4 | 73.7 |
PC | + | 93.5 | 86.9 | 69.3 | 60.5 | 62.7 |
PHS | + | 89.1 | 79.2 | 78.1 | 73.7 | 69.3 |
TAG | + | 92.4 | 88 | 86.9 | 80.3 | 84.7 |
Table 6: The effects of alternative mobile phase additives for the ESI MS on the efficiencies of ionization for lipids of different classes. Different lipids were separated from each other by reverse-phase liquid chromatography. Commercial lipid standards that belong to different classes of lipids are named in Table 1. The ESI (-) or ESI (+) mode of ionization was used for MS in the presence of different mobile phase additives. The percentage of ionization for each lipid standard is shown as a mean value from three technical replicates. For each lipid, the ionization percentage was calculated based on the MS peak area. A value of the highest ionization efficiency for each lipid is displayed in bold. Abbreviations: AmF = ammonium formate; AmF/FA = ammonium formate with formic acid; AmAc = ammonium acetate; AmAc/AA = ammonium acetate with acetic acid; AmAc/FA = ammonium acetate with formic acid; CL = cardiolipin; FFA = free (unesterified) fatty acid; PC = phosphatidylcholine; PE = phosphatidylethanolamine; PG = phosphatidylglycerol; PHC = phytoceramide; PHS = phytosphingosine; PI = phosphatidylinositol; PS = phosphatidylserine; TAG = triacylglycerol.
Lipid standard | ESI mode | AmF | AmAc |
PHC | – | 75 | 83.8 |
CL | – | 70.9 | 79.3 |
FFA | – | 76.1 | 74.5 |
PE | – | 98 | 95 |
PG | – | 64 | 75.9 |
PI | – | 79.3 | 82.5 |
PS | – | 71.5 | 84.8 |
PC | + | 52.3 | 60.5 |
PHS | + | 78.4 | 75.2 |
TAG | + | 65.7 | 69.7 |
Table 7: The effect of the collision-induced dissociation (CID) method on the efficiency of precursor ions (MS1) fragmentation. Commercial lipid standards that belong to different classes of lipids are named in Table 1. The ESI (-) or ESI (+) mode of ionization was used for MS, in the presence of an ammonium formate (AmF) or ammonium acetate (AmAc) mobile phase additive. The percentage of MS1 lipid ions that were fragmented into MS2 products is shown as a mean value from three technical replicates. For each lipid, the ionization percentage was calculated based on the MS2 peak area. A value of the highest percentage of MS1 lipid ions that were fragmented is displayed in bold for each lipid (compare with the data presented in Table 8). This value is the highest if the efficiency of MS2 product ion formation is the highest. Abbreviations: CL = cardiolipin; FFA = free (unesterified) fatty acid; PC = phosphatidylcholine; PE = phosphatidylethanolamine; PG = phosphatidylglycerol; PHC = phytoceramide; PHS = phytosphingosine; PI = phosphatidylinositol; PS = phosphatidylserine; TAG = triacylglycerol.
Lipid standard | ESI mode | AmF | AmAc |
PHC | – | 68.4 | 65.4 |
CL | – | 74.3 | 75.2 |
FFA | – | 84.2 | 81.2 |
PE | – | 85.1 | 73.1 |
PG | – | 68.4 | 67.1 |
PI | – | 58.7 | 55.8 |
PS | – | 67.4 | 68.5 |
PC | + | 92.5 | 65.3 |
PHS | + | 87.1 | 75.1 |
TAG | + | 91.4 | 84.9 |
Table 8: The effect of the high-energy collisional dissociation (HCD) method on the efficiency of precursor ions (MS1) fragmentation. Commercial lipid standards that belong to different classes of lipids are named in Table 1. The ESI (-) or ESI (+) mode of ionization was used for MS, in the presence of an ammonium formate (AmF) or ammonium acetate (AmAc) mobile phase additive. The percentage of MS1 lipid ions that were fragmented into MS2 products is shown as a mean value from three technical replicates. For each lipid, the ionization percentage was calculated based on the MS2 peak area. A value of the highest percentage of MS1 lipid ions that were fragmented is displayed in bold for each lipid (compare with the data presented in Table 7). This value is the highest if the efficiency of MS2 product ion formation is the highest. Other abbreviations: CL = cardiolipin; FFA = free (unesterified) fatty acid; PC = phosphatidylcholine; PE = phosphatidylethanolamine; PG = phosphatidylglycerol; PHC = phytoceramide; PHS = phytosphingosine; PI = phosphatidylinositol; PS = phosphatidylserine; TAG = triacylglycerol.
Supplemental Table 1: A list of molecular species of 10 different lipid classes identified and quantified in S. cerevisiae cells with the help of our LC-MS/MS method. These lipid classes included free (unesterified) fatty acids (FFA), cardiolipin (CL), phytoceramide (PHC), phytosphingosine (PHS), phosphatidylcholine (PC), phosphatidylethanolamine (PE), phosphatidylglycerol (PG), phosphatidylinositol (PI), phosphatidylserine (PS), and triacylglycerol (TAG). S. cerevisiae cells were cultured in the synthetic minimal YNB medium initially containing 2% glucose. Aliquots of yeast cells for lipid extraction and LC-MS/MS analysis of extracted lipids were recovered on days 1, 2, 3, 4, 6, 8, and 10 of culturing. All lipid species of each lipid class that were identified in yeast cells recovered on different days of culturing are shown. Some of these lipid species were present only in chronologically young yeast cells recovered on days 1-4 of culturing, others only in chronologically old yeast cells recovered on days 6-10 of culturing, whereas some were present in both chronologically young and old yeast cells. The highest MS peak area for each lipid species of each lipid class identified on a certain day of culturing is shown. Lipid standards of different lipid classes that were used for quantitation of other species within this lipid class are displayed in red color. The calculated m/z values are for the adducts of lipids. Abbreviation: ESI (-) = the ESI (-) mode of MS; ESI (+) = the ESI (+) mode of MS. Data are presented as mean values of two independent experiments, for each of which three technical replicates were performed. Please click here to view this table (Right click to download).
The following precautions are important for the successful implementation of the protocol described here:
1. Chloroform and methanol are toxic. They efficiently extract various substances from surfaces, including laboratory plasticware and your skin. Therefore, handle these organic solvents with caution by avoiding the use of plastics in steps that involve contact with chloroform and/or methanol, using borosilicate glass pipettes for these steps, and rinsing these pipettes with chloroform and methanol before use.
2. During lipid extraction by methanol/chloroform (17:1) mixture, use a borosilicate glass pipette to transfer the lower organic phase (~400 µL) to a 15 mL high-strength glass screw top centrifuge tube with a polytetrafluoroethylene lined cap. Do not disrupt the glass beads or upper aqueous phase during such transfer. Keep the lower organic phase under the flow of nitrogen gas.
3. During sample preparation for LC-MS/MS, it is important to eliminate all air bubbles in the glass vials before inserting the vials into a wellplate.
4. To achieve a complete solubilization of ammonium formate and ammonium acetate in mobile phases A and B prior to lipid separation by LC, dissolve each salt in 500 µL of nano-pure water before mixing the solution with the mobile phase and sonicating for 20 min.
5. Do not store the lipid film formed after solvent evaporation for a long period of time prior to running. We store this film at -80 °C for no more than a week before dissolving it in the acetonitrile/2-propanol/nano-pure water (65:35:5) mixture and then subjecting the lipids to LC-MS/MS.
The LC-MS/MS method described here is a versatile, robust, and sensitive technique for a quantitative assessment of many lipid species comprising the cellular lipidome of yeast or any other eukaryotic organism. The method enables the identification and quantification of different isobaric or isomeric lipid species, allows to use alternative mobile phase additives for the ESI MS to promote lipid ionization and to make lipid identification and quantification more efficient, and can use both HCD and CID methods for the fragmentation or activation of MS1 lipid ions.
We use this LC-MS/MS method to study age-related changes in the cellular and organellar lipidomes during chronological aging of the budding yeast S. cerevisiae. We also employ this method to investigate how many aging-delaying genetic, dietary, and pharmacological interventions influence lipid composition of the entire S. cerevisiae cell and its various organelles. Because of its versatility, robustness, and sensitivity, this LC-MS/MS method can be successfully used for the quantitative assessment of the cellular and organellar lipidomes in eukaryotic organisms across phyla.
The authors have nothing to disclose.
We are grateful to current and former members of the Titorenko laboratory for discussions. We acknowledge the Centre for Biological Applications of Mass Spectrometry and the Centre for Structural and Functional Genomics (both at Concordia University) for outstanding services. This study was supported by grants from the Natural Sciences and Engineering Research Council (NSERC) of Canada (RGPIN 2014-04482) and Concordia University Chair Fund (CC0113). K.M. was supported by the Concordia University Merit Award.
15 mL High-speed glass centrifuge tubes with Teflon lined caps | PYREX | 05-550 | |
2 mL Glass sample vials with Teflon lined caps | Fisher Scientific | 60180A-SV9-1P | |
2-Propanol | Fisher Scientific | A461-500 | |
Acetonitrile | Fisher Scientific | A9554 | |
Agilent 1100 series LC system | Agilent Technologies | G1312A | |
Agilent1100 Wellplate | Agilent Technologies | G1367A | |
Ammonium acetate | Fisher Scientific | A11450 | |
Ammonium bicarbonate | Sigma | 9830 | |
Ammonium formate | Fisher Scientific | A11550 | |
Ammonium hydroxide | Fisher Scientific | A470-250 | |
Bactopeptone | Fisher Scientific | BP1420-2 | |
Cardiolipin | Avanti Polar Lipids | 750332 | |
Centra CL2 clinical centrifuge | Thermo Scientific | 004260F | |
Ceramide | Avanti Polar Lipids | 860517 | |
Chloroform | Fisher Scientific | C297-4 | |
CSH C18 VanGuard | Waters | 186006944 | Pre-column system |
Free fatty acid (19:0) | Matreya | 1028 | |
Glass beads (acid-washed, 425-600 μM) | Sigma-Aldrich | G8772 | |
Glucose | Fisher Scientific | D16-10 | |
Hemacytometer | Fisher Scientific | 267110 | |
L-histidine | Sigma | H8125 | |
Lipid Search software (V4.1) | Fisher Scientific | V4.1 | LC-MS/MS analysis software |
L-leucine | Sigma | L8912 | |
L-lysine | Sigma | L5501 | |
Methanol | Fisher Scientific | A4564 | |
Phosphatidylcholine | Avanti Polar Lipids | 850340 | |
Phosphatidylethanolamine | Avanti Polar Lipids | 850704 | |
Phosphatidylglycerol | Avanti Polar Lipids | 840446 | |
Phosphatidylinositol | Avanti Polar Lipids | LM1502 | |
Phosphatidylserine | Avanti Polar Lipids | 840028 | |
Reverse-phase column CSH C18 | Waters | 186006102 | |
Sphingosine | Avanti Polar Lipids | 860669 | |
Thermo Orbitrap Velos MS | Fisher Scientific | ETD-10600 | |
Tricylglycerol | Larodan, Malmo | TAG Mixed FA | |
Ultrasonic sonicator | Fisher Scientific | 15337416 | |
Uracil | Sigma | U0750 | |
Vortex | Fisher Scientific | 2215365 | |
Yeast extract | Fisher Scientific | BP1422-2 | |
Yeast nitrogen base without amino acids | Fisher Scientific | DF0919-15-3 | |
Yeast strain BY4742 | Dharmacon | YSC1049 |