Summary

Majör Histo-uyum Kompleks sınıf II Dextramers kullanarak Beyin ve Heart reaktif CD4 T hücrelerinin in situ tespiti

Published: August 01, 2014
doi:

Summary

MHC kompleksi sınıf II dextramers ile direkt boyama ile beyin ve kalp kendinden reaktif CD4 T hücreleri algılamak için protokol bu raporda tarif edilmiştir. Kapsamlı bir analiz için in situ antijene özgü CD4 + T hücrelerinin frekansları numaralandırmak için güvenilir bir yöntem de planlanmaktadır.

Abstract

This report demonstrates the use of major histocompatibility complex (MHC) class II dextramers for detection of autoreactive CD4 T cells in situ in myelin proteolipid protein (PLP) 139-151-induced experimental autoimmune encephalomyelitis (EAE) in SJL mice and cardiac myosin heavy chain-α (Myhc) 334-352-induced experimental autoimmune myocarditis (EAM) in A/J mice. Two sets of cocktails of dextramer reagents were used, where dextramers+ cells were analyzed by laser scanning confocal microscope (LSCM): EAE, IAs/PLP 139-151 dextramers (specific)/anti-CD4 and IAs/Theiler’s murine encephalomyelitis virus (TMEV) 70-86 dextramers (control)/anti-CD4; and EAM, IAk/Myhc 334-352 dextramers/anti-CD4 and IAk/bovine ribonuclease (RNase) 43-56 dextramers (control)/anti-CD4. LSCM analysis of brain sections obtained from EAE mice showed the presence of cells positive for CD4 and PLP 139-151 dextramers, but not TMEV 70-86 dextramers suggesting that the staining obtained with PLP 139-151 dextramers was specific. Likewise, heart sections prepared from EAM mice also revealed the presence of Myhc 334-352, but not RNase 43-56-dextramer+ cells as expected. Further, a comprehensive method has also been devised to quantitatively analyze the frequencies of antigen-specific CD4 T cells in the ‘Z’ serial images.

Introduction

Majör histokompatibilite kompleksinin kullanımı antijene özgü CD4 T hücrelerinin saptanması için (MHC) sınıf II tetramerler bir sorun 1-7 olmuştur. MHC sınıf II tetramerler algılama hassasiyetini artırmak için, araştırma ekibi belirlenen nesil tetramers, "dextramers" 8 yarattı. Dextramers örneğin birkaç peptide gergin, biyotinile edilmiş monomerler, bir MHC molekülüne dekstran 9 bağlı olabilir birden fazla streptavidin-fluorofor kısımları konjüge edildiği dekstran omurgalar içerir. Böylece, birkaç MHC-peptid komplekslerini içeren MHC dextramers büyük agrega çok T hücre reseptörleri (TCRler) ile etkileşime girebilir.

Bu grup, son zamanlarda çeşitli self-antijenlerine dextramers üretilir ve dextramers algılama hassasiyeti tetramerleri, yaklaşık 8 den fazla beş kat olduğu gösterilmiştir. Deney Sistemleri deneysel otoimmün ensefalomiyelit içerir (EAE) proteolipid protein (PLP) SJL farelerinde 139-151 ile indüklenen; EAE miyelin oligodendrosit glikoprotein (MOG) C57BL / 6 farelerinde 35-55 ile indüklenen; ve deneysel otoimmün miyokardit (EAM), kardiyak miyosin ağır zincir-α (Myhc) A / J farelerinde 334-352 ile neden oldu. Bu çalışma, PLP 139-151 kullanımını gösterir – ve Myhc 334-352 böylece florofor antikorlar kullanılarak gelen sinyalleri yükseltmek için ihtiyacı ortadan kaldırarak, direkt bir boyama protokolü geliştirerek özgüllük ile in situ olarak antijene spesifik CD4 T hücrelerini tespit etmek için bir dextramers Yaygın bir yaklaşım tetramerleri kullanımı ile kullanılabilir. Buna ek olarak, doku değerlendirilmesi kapsamlı bir yöntem de güvenilir bir şekilde yerinde 10 antijene spesifik CD4 T hücrelerinin frekansları numaralandırmak için tasarlanmış edilmiştir. In situ olarak antijen-spesifik T hücrelerinin aktivasyonunun tespiti seyirci neden olduğu belirli antijenik uyarıcılarla neden olduğu olaylar çizimi izin verir. Benzer şekilde, in situ tekniği de providhedef organ içinde antijen-spesifik T hücresi sızıntılar kinetiğini takip etmek için fırsatlar es.

Protocol

Etik Açıklama: Bütün hayvan prosedürleri Laboratuar Hayvanlarının Bakımı ve Kullanımı kurallarına uygun olarak yapılmıştır ve Nebraska-Lincoln, Lincoln, NE Üniversitesi tarafından onaylanmıştır. EAE 1. İndüksiyon Aşama 1.1: EAE neden olmak için, aşağıdaki modifikasyonlar ile 11 'de tarif edildiği gibi peptid / tam Freund adjuvanı (CFA) emülsiyonu hazırlamak. 1 x fosfat tamponlu tuzlu su (PBS) içind…

Representative Results

Bu raporda, MHC sınıf II ile doğrudan dextramers lekelemesi ile antijen spesifik, oto-reaktif CD4 T hücrelerinin in situ tespiti tarif edilmektedir. Taze kesilmiş beyin kesitleri EAE farelerden türetilen ve (kontrol) dextramers ve anti-CD4 (özel) veya TMEV 70-86 PLP 139-151 içeren kokteyller ile boyandı. Şekil 1 'de üst paneller Çift pozitif hücreler, sarı çıktı PLP 139-151 dextramers (kırmızı) ve CD4 antikoru (yeşil) ile costained beyin bölümlerinin LSCM analizini g?…

Discussion

MHC sınıf I tetramerleri farklı olarak, rutin uygulamalar için MHC sınıf II tetramerleri kullanımı özellikle aktivasyon bağımlılık 6,15-17 kısmen nedeniyle düşük-yakınlık oto-reaktif CD4 T hücrelerinin, bir ön-madde frekansları numaralandırmak için, zor olmaya devam etmektedir. Son zamanlarda, bu sorun, PLP'ye 139-151, MOG 35-55 ve Myhc 334 gibi Otoantijenler, bir dizi için antijen-spesifik CD4 T hücreleri algılamak için bize izin ", dextramers" denilen tetramerler ne…

Divulgations

The authors have nothing to disclose.

Acknowledgements

Bu çalışma, Amerikan Kalp Derneği ve Çocuk Kardiyomiyopati Vakfı (SDG2462390204001) ve Ulusal Sağlık Enstitüleri (HL114669) tarafından desteklenmiştir. CM Miyokardit Vakfı, NJ tarafından verilen doktora sonrası araştırma bursu hibe bir alıcı.

Materials

CFA Sigma Aldrich, St Louis, MO 5881 Store at 4οC
MTB  H37Rv extract  Difco Laboratories, Detroit, MI 231141 Store at 4οC
PT List Biologicals Laboratories, Campbell, CA 181 Store at 4οC
1x PBS  Corning, Manassas, VA 21-040-CV Store at 4οC
Female A/J mice  Jackson Laboratories, Bar Harbor, ME 646
Female SJL/J mice Jackson Laboratories, Bar Harbor, ME 686
Leur-lok sterile 1 ml syrringe BD, Franklin Lakes, NJ 309628
Leur-lok sterile 3 ml syrringe BD, Franklin Lakes, NJ 309657
Sterile needle, 18 G BD, Franklin Lakes, NJ 305195
Sterile needle, 27 1/2 G BD, Franklin Lakes, NJ 305109
3-way stopcock  Smiths Medical ASD, Inc. Dublin, OH MX5311L
Kerlix gauze bandage rolls  Covidien, Mansfield, MA 6720
Kimwipes Kimberly-Clark Professional, Roswell, GA 34155
Agarose, Low Melting Point, Analytical Grade Promega corporation, Madison, WI V2111
Immunopure normal goat serum Thermo Scientific, Waltham, MA 31873 Store at -20 οC
Anti-mouse CD4 conjugated with PE dye eBioscience, San Diego, CA  12004185 Store at 4οC
Paraformaldehyde Electron Microscopy Sciences, Hatfield, PA 19202 Store at 4οC
Faramount Aqueous Mounting Medium Dako, Carpinteria, CA 10073021
Conical tube (15ml) BD Biosciences, San Jose, CA 352099
Conical tube (50 ml) BD Biosciences, San Jose, CA 352070
24-well flat bottomed tissue culture plates BD Biosciences, San Jose, CA 356775
Water color #2 brushes Charles Leonard, Inc. Hauppauge, NY 73502
Plain Microscope slides, size: 3" x 1" x 1.2 mm Fisher Scientific, Pittsburgh, PA 1255010
Premium Cover glass, 22 x 22-1 Fisher Scientific, Pittsburgh, PA 12548B
Disposable deep base mold histology cassettes Laboratory prodcust, Rochester, NY M-475-10
Loctite Super glue Henkel Corporation, Westlake, OH 1471879
Razor blades Gillette SuperSilver
Myhc-a 334-352 (DSAFDVLSFTAEEKAGVYK) Neopeptide, Cambridge, MA Store at 4οC
PLP 139-151 (HSLGKWLGHPDKF) Neopeptide, Cambridge, MA Store at 4οC
MHC class II/IAs PLP 139-151 or TMEV 70-86 dextramers conjugated with APC dye Store at 4οC
MHC class II/IAk Myhc 334-352 or  or RNase 40-56 dextramers conjugated with APC dye Store at 4οC
Dextran conjugated SA-APC  Immundex, Copenhagen, Demark Store at 4οC
Sterile surgical scissors and forceps INOX tool Corporation
Micro oven GE Healthcare, Pittsuburgh, PA
Leica VT 1200 Vibratome Leica Microsystems, Inc. Buffalo Grove, IL
Olympus BX 60  Laser scanning confocal microscope Olympus America, Inc. Center Valley, PA
Nikon A1-Eclipse 90i confocal microscope Nikon Inc. Melville, NY

References

  1. Cecconi, V., Moro, M., Del Mare, ., Dellabona, S., P, G., Casorati, Use of MHC class II tetramers to investigate CD4+ T cell responses: problems and solutions. Cytometry A. 73 (11), 1010-1018 (2008).
  2. Ferlin, W., Glaichenhaus, N., Mougneau, E. Present difficulties and future promise of MHC multimers in autoimmune exploration. Curr Opin Immunol. 12, 670-675 (2000).
  3. Kwok, W. W., Ptacek, N. A., Liu, A. W., Buckner, J. H. Use of class II tetramers for identification of CD4+ T cells. J Immunol Methods. 268, 71-81 (2002).
  4. Landais, E., et al. New design of MHC class II tetramers to accommodate fundamental principles of antigen presentation. J Immunol. 183, 7949-7957 (2009).
  5. Nepom, G. T. MHC class II tetramers. J Immunol. 188, 2477-2482 (2012).
  6. Vollers, S. S., Stern, L. J. Class II major histocompatibility complex tetramer staining: progress, problems, and prospects. Immunology. 123, 305-313 (2008).
  7. Wooldridge, L., et al. Tricks with tetramers: how to get the most from multimeric peptide-MHC. Immunology. 126, 147-164 (2009).
  8. Massilamany, C., Upadhyaya, B., Gangaplara, A., Kuszynski, C., Reddy, J. Detection of autoreactive CD4 T cells using major histocompatibility complex class II dextramers. BMC Immunol. 12, 1471-2172 (2011).
  9. Batard, P., et al. Dextramers: new generation of fluorescent MHC class I/peptide multimers for visualization of antigen-specific CD8+ T cells. J Immunol Methods. 310 (1-2), 136-148 (2006).
  10. Massilamany, C., Gangaplara, A., Jia, T., et al. Direct staining with major histocompatibility complex class II dextramers permits detection of antigen-specific, autoreactive CD4 T cells in situ. PLoS One. 9 (1), (2014).
  11. Massilamany, C., Khalilzad-Sharghi, V., Gangaplara, A., Steffen, D., Othman, S. F., Reddy, J. Noninvasive Assessment of Cardiac Abnormalities in Experimental Autoimmune Myocarditis by Magnetic Resonance Microscopy Imaging in the Mouse. J Vis Exp. (88), e51654 (2014).
  12. Massilamany, C., Steffen, D., Reddy, J. An epitope from Acanthamoeba castellanii that cross-react with proteolipid protein 139-151-reactive T cells induces autoimmune encephalomyelitis in SJL mice. J Neuroimmunol. 219 (1-2), 17-24 (2010).
  13. Donermeyer, D. L., Beisel, K. W., Allen, P. M., Smith, S. C. Myocarditis-inducing epitope of myosin binds constitutively and stably to I-Ak on antigen-presenting cells in the heart. J Exp Med. 182 (5), 1291-1300 (1995).
  14. Liao, L., Sindhwani, R., Leinwand, L., Diamond, B., Factor, S. Cardiac alpha-myosin heavy chains differ in their induction of myocarditis. Identification of pathogenic epitopes. J Clin Invest. 92 (6), 2877-2882 (1993).
  15. Cameron, T. O., Cochran, J. R., Yassine-Diab, B., Sekaly, R. P., Stern, L. J. Cutting edge: detection of antigen-specific CD4+ T cells by HLA-DR1 oligomers is dependent on the T cell activation state. J Immunol. 166 (2), 741-745 (2001).
  16. Novak, E. J., et al. Activated human epitope-specific T cells identified by class II tetramers reside within a CD4high, proliferating subset. Int Immunol. 13 (6), 799-806 (2001).
  17. Reddy, J., et al. Detection of autoreactive myelin proteolipid protein 139-151-specific T cells by using MHC II (IAs) tetramers. J Immunol. 170 (2), 870-877 (2003).
  18. Skinner, P. J., Daniels, M. A., Schmidt, C. S., Jameson, S. C., Haase, A. T. Cutting edge: In situ tetramer staining of antigen-specific T cells in tissues. J Immunol. 165 (2), 613-617 (2000).
  19. Skinner, P. J., Haase, A. T. In situ tetramer staining. J Immunol Methods. 268 (1), 29-34 (2002).
  20. Skinner, P. J., Haase, A. T. In situ staining using MHC class I tetramers. Curr Protoc Immunol. Chapter 17, Unit 17.14.11 (2004).

Play Video

Citer Cet Article
Massilamany, C., Gangaplara, A., Jia, T., Elowsky, C., Li, Q., Zhou, Y., Reddy, J. In Situ Detection of Autoreactive CD4 T Cells in Brain and Heart Using Major Histocompatibility Complex Class II Dextramers. J. Vis. Exp. (90), e51679, doi:10.3791/51679 (2014).

View Video