Recording Neural Activity in Freely Moving Mice Using Fiber Photometry

Published: October 31, 2024

Abstract

Source: Martianova, E., et al. Multi-Fiber Photometry to Record Neural Activity in Freely-Moving Animals. J. Vis. Exp. (2019).

This video demonstrates a method for recording neural activity in a freely moving mouse using fiber photometry. In this method, neurons in a specific brain region express a genetically encoded calcium indicator. A stimulus is applied to this brain region, and the stimulus-dependent change in fluorescence is measured to identify neural activity.

Protocol

All procedures involving animal models have been reviewed by the local institutional animal care committee and the JoVE veterinary review board.

1. Alignment of the optical path between the CMOS (complementary metal oxide semiconductor) camera and the individual or branching patch cord

  1. Loosen all screws on the 5-axis translator (Figure 1B).
  2. Screw in the patch cord (Figure 1B) to the adaptor [SMA (sub-miniature A) or FC (fiber optic connector)] that is affixed to the 5-axis translator.
  3. Turn on the 470 nm excitation light (Figure 1B) at low power (100 μW) and place the tip of the patchcord pointing to an autofluorescent plastic slide. This does not have any bearing on future recordings but is solely for visualizing the alignment process.
  4. Record from the CMOS camera (Figure 1B) in live mode. Increase the gain or adjust the lookup table (LUT) until the image is not entirely black. The point is to be able to see an image at the focal point of the objective (Figure 1B).
  5. Advance the 5-axis translator towards the objective, ensuring that the 470 nm light is centered on the fiber at the SMA or FC end of the patch cord until an image can be resolved on the camera.
  6. Adjust the X and Y axes until the image is centered and well-resolved.
  7. Visualize the light emitted from the ferrule end of the patch cord. It should appear as an isotropic circle. If a branching patch cord is used, the amount of light emitted at the ferrule ends of each patch cord should be similar. If the circle is not isotropic or the emitted light is unequal, adjust the 5-axis translator in the X-Y axis.

2. Setup of ROIs around fibers for measurement of mean fluorescent intensity

  1. Turn on all the excitation lights to visualize the fibers better. Adjust the camera gain so that no pixels are saturated and a clear image of the fibers is present.
  2. Live record or take a preliminary image.
  3. Draw ROIs around the fibers and keep them for measuring the mean intensity values during recordings (Figure 1A).
  4. For multiple fiber recordings, test for independence in signals.
    1. Live record from all fibers.
    2. Point one fiber towards a light source and tap with a finger. Large fluctuations should occur solely in that channel (acceptable leakage 1:1000).
    3. If the signals are not independent, redraw more conservative ROIs and repeat the independence test.
  5. To label and track which ROI corresponds to which fiber, colored tape, or nail polish can be applied to the end of the fibers. Take a picture before the start of any experiment as a secondary reminder.

3. Setup of recording arena

  1. Hang the patch cord above the arena using stands, clamps, or holders.
  2. Make sure that the animal can freely move throughout the entire arena, uninhibited by the length of the fiber.
  3. If an operant box or open field is used, ensure the patch cord can reach the animal with minimal bending. If this requires a nose poke, ensure that there is enough room overhead to prevent the bending of the fiber. Avoid any excessive bending or twisting of the patch cord.

4. In vivo recordings

  1. Visually inspect the distal end of the fibers of the patch cord by eye and with a minifiber microscope. If the surface of the fibers is scratched, repolish the fibers using fiber polishing/lapping film with fine grit (1 μm and 0.3 μm).
  2. Clean the distal ends of the patch cord with 70% ethanol and a cotton tip applicator.
  3. Clean the fiber-optic cannulas using 70% ethanol and a cotton tip applicator.
  4. Connect the ferrule end of the patch cord to the implanted fiber using a ceramic split sleeve covered with a black shrink tube. Ensure the sleeve is tight during the connection. Otherwise, use a new sleeve.
    NOTE: If there is any space between the patch cord ferrule and the implant, there will be a large amount of signal loss, and the recordings will not work.
  5. Allow the animal to recover for a few minutes before the start of behavioral testing.
  6. Start recording the optical signal and run the experiment.
  7. While recording, keep a careful eye on the live-trace to ensure quality recordings. The signal is expected to rapidly decrease as a function of time in the first 2 min of recording. This effect is caused by heat-mediated LED decay, whereby the increase in heat increases the resistance of the optical element.
  8. If a jump in the signal that exceeds the on/off kinetics of GCaMP occurs, this often indicates that the sleeve is not tight enough and the space between the patch cord and the implant is changing. In this case, stop the experiment and reconnect the animal using a new sleeve.

Representative Results

Figure 1
Figure 1: Fiber photometry schematic. (A) The excitation light from two LEDs (410 nm and 470 nm) passes through a series of filters and dichroic mirrors and produces an excitation spot at the working distance of the 20x objective. The light passes through either a single patch cord or bundled fibers (for multiple site recordings) connected to the implanted cannulas. The emitted fluorescence is collected by the same fibers, filtered, and projected on a CMOS camera sensor. On the captured images, the mean fluorescence intensity is recorded at the ROIs of each fiber. A time-division multiplexing is implemented to simultaneously acquire signals from both 410 nm and 470 nm LEDs (lower right diagram). (B) Image of our custom-made photometry system and its components: (1) Fiber to the 465 nm LED, (2) Fiber to the 405 nm LED, (3) Collimators, (4) 470 nm bandpass filter, (5) 410 nm bandpass filter, (6) 535 nm bandpass filter, (7) Tube lens, (8) Cube with longpass 425 dichroic mirror, (9) Cube with longpass 495 dichroic mirror, (10) 20x objective, (11) 5-axis translator, (12) Mono- or bundled-fiber patch cord, (13) CMOS camera.

Divulgations

The authors have nothing to disclose.

Materials

1/4"-20 Stainless Steel Cap Screw, 1" Long Thorlabs SH25S100
1/4"-20 Stainless Steel Cap Screw, 1/2" Long Thorlabs SH25S050
1/4"-20 Stainless Steel Cap Screw, 3/8" Long Thorlabs SH25S038
1000 µm, 0.50 NA, SMA-SMA
 Fiber Patch Cable
Thorlabs M59L01
12.7 mm Optical Post Thorlabs TR30/M
12.7 mm Pedestal Post Holder Thorlabs PH20EM
15 V, 2.4 A Power Supply Unit with
 3.5 mm Jack Connector for T-Cube
Thorlabs KPS101
20x objective Thorlabs RMS20X
30 mm Cage Cube with Dichroic Filter Mount Thorlabs CM1-DCH/M
405 nm LED Doric Lenses CLED_405
410 nm bandpass filter Thorlabs FB410-10
465 nm. LED Doric Lenses CLED_465
470 nm bandpass filter Thorlabs FB470-10
560 nm bandpass filter Semrock FF01-560/14-25
560 nm LED Doric Lenses CLED_560
5-axis kinematic Mount Thorlabs K5X1
Achromatic Doublet Thorlabs AC254-035-A-ML
Adaptor for 405 collimator Thorlabs AD11F
Adaptor for ajustable collimator Thorlabs AD127-F
Aluminum Breadboard Thorlabs MB1824
Clamping Fork Thorlabs CF125
Cube connector Thorlabs CM1-CC
Dual 493/574 dichroic Semrock FF493/574-Di01-25×36
Emission filter for GCaMP6 Semrock FF01-535/22-25
Enclosure with Black Hardboard Panels Thorlabs XE25C9
Externally SM1-Threaded End Cap for Machining Thorlabs SM1CP2M
Fast-change SM1 Lens Tube Filter Holder Thorlabs SM1QP
Fixed Collimator for 405 nm light Thorlabs F671SMA-405
Fixed collimator for 470 and 560 nm light Thorlabs F240SMA-532
Green emission filter Semrock FF01-520/35-25 In light beam splitter
High-Resolution USB 3.0 CMOS Camera Thorlabs DCC3260M
Light beam splitter Neurophotometrics SPLIT
Longpass Dichroic Mirror, 425 nm Cutoff Thorlabs DMLP425R
Longpass Dichroic Mirror, 495 nm Cutoff Semrock FF495-Di03
Metabond dental cement C&B
M8 – M8 cable Doric Lenses Cable_M8-M8
Optic fiber cannulas Doric Lenses Need to specify that these will be used to photometry experiments requiring low autofluorescence
Optic fiber Patchcords Doric Lenses Need to specify that these will be used to photometry experiments requiring low autofluorescence
Red emission filter Semrock FF01-600/37-25 In light beam splitter
T7 LabJack LabJack
T-cube LED Driver Thorlabs LEDD1B
USB 3.0 I/O Cable, Hirose 25, for DCC3240 Thorlabs CAB-DCU-T3