Here we present how to expose the geniculate ganglion of a live, anesthetized laboratory mouse and how to use calcium imaging to measure the responses of ensembles of these neurons to taste stimuli, allowing for multiple trials with different stimulants. This allows for in depth comparisons of which neurons respond to which tastants.
Within the last ten years, advances in genetically encoded calcium indicators (GECIs) have promoted a revolution in in vivo functional imaging. Using calcium as a proxy for neuronal activity, these techniques provide a way to monitor the responses of individual cells within large neuronal ensembles to a variety of stimuli in real time. We, and others, have applied these techniques to image the responses of individual geniculate ganglion neurons to taste stimuli applied to the tongues of live anesthetized mice. The geniculate ganglion is comprised of the cell bodies of gustatory neurons innervating the anterior tongue and palate as well as some somatosensory neurons innervating the pinna of the ear. Imaging the taste-evoked responses of individual geniculate ganglion neurons with GCaMP has provided important information about the tuning profiles of these neurons in wild-type mice as well as a way to detect peripheral taste miswiring phenotypes in genetically manipulated mice. Here we demonstrate the surgical procedure to expose the geniculate ganglion, GCaMP fluorescence image acquisition, initial steps for data analysis, and troubleshooting. This technique can be used with transgenically encoded GCaMP, or with AAV-mediated GCaMP expression, and can be modified to image particular genetic subsets of interest (i.e., Cre-mediated GCaMP expression). Overall, in vivo calcium imaging of geniculate ganglion neurons is a powerful technique for monitoring the activity of peripheral gustatory neurons and provides complementary information to more traditional whole-nerve chorda tympani recordings or taste behavior assays.
A key component of the mammalian peripheral taste system is the geniculate ganglion. In addition to some somatosensory neurons that innervate the pinna of the ear, the geniculate is comprised of the cell bodies of gustatory neurons innervating the anterior tongue and palate. Similar to other peripheral sensory neurons, the geniculate ganglion neurons are pseudo-unipolar with a long axon projecting peripherally to the taste buds, and centrally to the brainstem nucleus of the solitary tract1. These neurons are activated primarily by the release of ATP by taste receptor cells responding to taste stimuli in the oral cavity2,3. ATP is an essential neurotransmitter for taste signaling, and P2rx receptors expressed by the gustatory ganglion neurons are necessary for their activation4. Given that taste receptor cells express specific taste receptors for a particular taste modality (sweet, bitter, salty, umami, or sour), it has been hypothesized that gustatory ganglion neuron responses to taste stimuli would also be narrowly tuned5.
Whole nerve recordings have shown both the chorda tympani and the greater superior petrosal nerves conduct gustatory signals representing all five taste modalities to the geniculate ganglion6,7. However, this still left questions about the specificity of neuronal responses to a given tastant: if there are taste modality specific neurons, polymodal neurons, or a mixture of both. Single fiber recordings give more information about the activity of individual fibers and their chemical sensitivities8,9,10, but this methodology is limited to collecting data from small numbers of fibers. Similarly, in vivo electrophysiological recordings of individual rat geniculate ganglion neurons give information about the responses of individual neurons11,12,13, but still loses the activity of the population and yields relatively few neuron recordings per animal. In order to analyze the response patterns of neuronal ensembles without losing sight of the activity of individual neurons, new techniques needed to be employed.
Calcium imaging, especially using genetically encoded calcium indicators like GCaMP, has provided this technical breakthrough14,15,16,17,18. GCaMP uses calcium as a proxy for neuronal activity, increasing green fluorescence as calcium levels within the cell rise. New forms of GCaMP continue to be developed to improve the signal to noise ratio, adjust binding kinetics, and adapt for specialized experiments19. GCaMP provides single neuron resolution, unlike whole nerve recording, and can simultaneously measure responses of ensembles of neurons, unlike single fiber or single cell recording. Calcium imaging of the geniculate ganglia has already provided important information about the tuning profiles of these neurons in wild-type mice16,20, and has identified peripheral taste miswiring phenotypes in genetically manipulated mice18.
One major difficulty to applying in vivo calcium imaging techniques to the geniculate ganglion is that it is encapsulated within the bony tympanic bulla. In order to obtain optical access to the geniculate, delicate surgery is required to remove the layers of bones, while keeping the ganglion intact. For that purpose, we have created this guide to help other researchers access the geniculate ganglion and image the GCaMP mediated fluorescent responses of these neurons to taste stimuli in vivo.
Animal protocols were reviewed and approved by the Institutional Animal Care and Use Committees of the University of Texas San Antonio.
1. Pre-operative setup
NOTE: Please note that initial setup of equipment is not addressed here, as it will vary based on pump system, microscope, camera, and imaging software used. For setup instructions please refer to instructional materials provided by equipment vendor. For equipment used by the authors, please see the Table of Materials.
2. Anesthetizing and immobilizing the animal
NOTE: The following protocol is a terminal procedure optimized for mice of either sex weighing 18-35 g. It is recommended for use with animals between 10 and 12 weeks of age. It may be used with transgenic animals expressing Genetically Encoded Calcium Indicators (GECIs) such as the Snap25-GCaMP6s, or animals stereotaxically injected with viral GECIs. Gloves, lab coat, and face mask should be worn for entirety of protocol.
3. Tracheotomy
4. Breaking open the tympanic bulla
5. Exposing the geniculate
Figure 1: Surgical exposure of the geniculate ganglion. (A) Image of the mouse neck cavity post tracheotomy. Arrow is pointing to the digastric muscle lying over the surgical area explored in the rest of the figure. (B) Image of region under the previously indicated digastric muscle. Arrow indicates the seam in musculature for blunt dissection. (C) Image of the Tympanic Bulla. Arrow indicates seam in the bone to break with a surgical probe. (D) Image of surgical area after opening the bulla. Lower left arrow indicates the cochlea, upper arrow points to the tensor tympani. Boxed line indicates area in (E) and (F). (E) Image of surgical area after cochlea has been broken and the contents removed. White arrow indicates where to place surgical probe referenced in protocol step 5.6. (F) An image of the exposed geniculate ganglion. Arrow indicates body of the seventh nerve, dashed triangle surrounds the geniculate ganglion. Panels A-B, Scale = 5 mm. Panels C-F, Scale = 1 mm. Please click here to view a larger version of this figure.
6. Run tastant panel
Following the protocol, a transgenic Snap25-GCaMP6s animal was sedated, geniculate ganglia were exposed, and tastant was applied to the tongue while video was recorded. The aim of the experiment was to define which tastants elicited responses from each cell. Tastants (30 mM AceK, 5 mM Quinine, 60 mM NaCl, 50 mM IMP + 1 mM MPG, 50 mM Citric Acid)18 were dissolved in DI water and were applied to the tongue for 2 s separated by 13 s of DI water.
Figure 2: Responses of geniculate ganglion neurons to tastants using in vivo GCaMP6s imaging. (A) Epifluorescent image of the geniculate ganglion of a Snap25-GCaMP6s transgenic mouse during baseline as water is perfused over the tongue. Dashed lines indicate the approximate boundaries of the geniculate ganglion. The seventh cranial nerve is labeled as such. (B) Snapshot of the same ganglion in (A) as a sweet tastant (AceK 30 mM) is applied to the tongue of the mouse. Notice several individual neurons increase in fluorescence intensity. Dashed line box indicates sweet responding cell used in (C) end. (C) Traces from five neurons indicating the amplitude of their GCaMP6s mediated fluorescence in response to a panel of tastants comprising sweet (30 mM acesulfame K), bitter (5 mM quinine); salty (60 mM NaCl); umami (50 mM monopotassium glutamate and 1mM inosine monophosphate); and sour (50 mM citric acid). Colored bars show the placement and duration (2 s) of the stimulus over the time course of the experiment. These representative data do not include a response to umami. Individual neurons commonly respond to both bitter and sour stimuli (bottom trace) 16,18,20. Panels A-B, Scale = 5 mm. Panel C, horizontal scale bar indicates 6.5 seconds, vertical scale bar indicates threshold of 4% dF/F. Please click here to view a larger version of this figure.
As can be seen in Figure 2, taste stimuli applied to the tongue should result in a rapid, transient increase in GCaMP fluorescence, causing a noticeable change in brightness among responding neurons. The video can be analyzed with a variety of software packages to produce traces displaying the changes in fluorescence over baseline (dF/F) over time of individual regions of interest (such as individual neurons), thereby showing the responses of each cell to the tastant panel. In a successful surgery, in a Snap25-GCaMP6s transgenic line, it is typical to see responses in 20-40 neurons within a single ganglion/field of view. This may change depending on the transgenic line used or if AAV-GCaMP is used instead. Note that baseline fluorescence may be affected by a number of factors, including the expression level of the GCaMP, and possible damage to the cells during the surgery. Changes in fluorescence intensity above a threshold level (typically df/f > 3-fold above the average noise)20,21 is considered a positive response.
To determine the timing of stimulus delivery, the time it takes for liquid to flow through the lines should be measured in order to know when a fluid change actually contacts the tongue. To reduce this delay, use a moderate flow rate (5-10 ml/min) and a short length of tubing leading from the perfusion manifold to the oral cavity. Typically, with the stimuli described here, fluorescence starts almost immediately after tastant is applied to the tongue and will begin to fade almost immediately after the tastant is stopped and the oral cavity is washed with vehicle solution. When working with an unknown stimulus it can be helpful to observe the change in fluorescence of a region without responding neurons to compare overall changes in the image.
This work describes a step-by-step protocol to surgically expose the geniculate ganglion and visually record the activity of its neurons with GCaMP6s. This procedure is very similar to that described previously17, with a few notable exceptions. First, the use of a head post allows for easy adjustment of head positioning during surgery. Second, regarding stimulus delivery, the approach by Wu and Dvoryanchikov flows taste stimuli through esophageal tubing17, whereas this protocol delivers liquid directly into the mouth with a dispensing needle. Either method can be used to successfully evoke geniculate ganglion neuron responses by stimulating the fungiform and palatal taste buds.
A note on maintaining a clear imaging field: after breaking the cochlea, there will be continuous seepage of fluid within the cavity, including directly over the geniculate ganglion. It is also possible that bleeding will obscure the geniculate ganglion. While a small amount of seepage may not be sufficient to prevent imaging, even small amounts of blood can entirely occlude the ganglia. These issues can be addressed in a couple of ways. First, if seepage is relatively minor, it can be removed using a suction line fitted with a blunt dispensing needle between trials. Alternatively, liquid can also be wicked away from the field by carefully placing absorbent points posterior or lateral to the seventh nerve. If the flow is particularly bad, it may be necessary to apply suction to the cavity during imaging. A carefully placed suction line can keep the ganglia clear while being applied to a lateral location, so as to avoid obscuring the ganglia during imaging.
The imaging itself can be accomplished using different styles of microscope setups, each with its attendant advantages and limitations. When using an epifluorescence scope18,21, it is only possible to image the more superficial neurons. Another issue with epifluorescence imaging is that signals from deeper cells will come out as changes in background fluorescence (out of focus light) so be careful with the analysis not to pick up fluorescence changes from other cells in the ROI. For particularly thin structures, such as the geniculate ganglia, these issues may not be problematic. Use of a 2-photon16 or confocal20 microscope can potentially allow for imaging cells in deeper layers.
It is important to highlight a few critical steps and ways to troubleshoot common issues. First, it must be noted that analysis will vary considerably depending on the software used. The open-source software, ImageJ provides tools sufficient for preliminary analysis. First, remove small motion artifacts using the Image Stabilizer plugin22, Next use ImageJ to calculate the change in fluorescence divided by baseline fluorescence (dF/F). This can be accomplished using one of many open source macros for ImageJ23, the referenced macro provides detailed installation notes. For other macros please refer to their documentation. After correcting for dF/F, utilize the forward and reverse buttons at the bottom of the image stack to observe cell responses to stimuli. Using the lasso tool from the tool bar, select fluorescing cells individually. After selecting a cell use Image | Stacks | Plot-Z-Axis. This will provide sufficient information to determine response profiles and analyze the time related events of each region of interest (ROI). More advanced analysis was long the domain of custom scripts in Matlab, R, etc. However, the popularity of calcium imaging has gradually led to the development of multiple open-source resources for analysis including CaImAn, EZCalcium, and more24,25.
Calcium imaging is a powerful tool for examining the activity of neural ensembles with single neuron resolution. Because of the geniculate ganglion's small size, this protocol is especially powerful because the entire ganglion can be visualized within a single field. However, there are some limitations to this technique. In addition to the limitations common to all calcium imaging experiments, the surgical approach described here is invasive and must be carried out under anesthesia. This is a terminal procedure – the animal must be euthanized immediately after imaging. Therefore this surgical approach is not appropriate for awake/behaving recordings.
Over the past few years, researchers have used this technique to study response profiles of the neurons of the geniculate ganglion16,20,18. Recent work has focused on potential genetic markers that could be used to manipulate subpopulations within the ganglia and has shown how transgenic Cre driver lines and Cre-dependent GCaMP can be used to identify the response profiles of these populations26. Other work may use GCaMP with photo-activated proteins such as pa-mCherry to first identify and then mark cells activated by tastants to then be used in immunohistochemistry or in situ hybridization27. It may also be possible to utilize calcium dependent photo-convertible proteins such as CaMPARI to the same effect while using experimental methods very similar to those described here28. Regardless of the specific questions and experiments, calcium imaging offers a powerful tool for exploring the response profiles of neurons engaged in any number of activities, and its usefulness in exploring the taste system is only beginning.
The authors have nothing to disclose.
The authors thank S. Humayun for mouse husbandry. Funding for this work has been provided in part by UTSA's Brain Health Consortium Graduate and Postdoctoral Seed Grant (B.E.F.) and NIH-SC2-GM130411 to L.J.M.
1 x #5 Inox Forceps | Fine Science Tools | NC9792102 | |
1ml Syringe with luer lock | Fisher Scientific | 14-823-30 | |
2 x #3 Inox Forceps | Fine Science Tools | M3S 11200-10 | |
27 Gauge Blunt Dispensing Needle | Fisher Scientific | NC1372532 | |
3M Vetbond | Fisher Scientific | NC0398332 | |
4-40 Machine Screw Hex Nuts | Fastenere | 3SNMS004C | |
4-40 Socket Head Cap Screw | Fastenere | 3SSCS04C004 | |
Absorbent Points | Fisher Scientific | 50-930-668 | |
Acesulfame K | Fisher Scientific | A149025G | |
Artificial Tears | Akorn | 59399-162-35 | |
BD Allergist Trays with Permanently Attached Needle | Fisher Scientific | 14-829-6D | |
Blunt Retractors | FST | 18200-09 | |
Breadboard | Thor Labs | MB8 | |
Citric Acid | Fisher Scientific | A95-3 | |
Cohan-Vannas Spring Scissors | Fine Science Tools | 15000-02 | |
Contemporary Ortho-Jet Liquid | Lang | 1504 | |
Contemporary Ortho-Jet Powder | Lang | 1520 | |
Cotton Tipped Applicators | Fisher | 19-062-616 | |
Custom Head Post Holder | eMachineShop | See attached file 202410.ems | |
Custom Metal Head Post | eMachineShop | See attached file 202406.ems | |
DC Temperature Controller | FHC | 40-90-8D | |
Digital Camera, sCMOS OrcaFlash4 Microscope Mounted | Hamamatsu | C13440 | |
Disection Scope | Leica | M80 | |
Hair Clippers | Kent Scientific | CL7300-Kit | |
IMP | Fisher Scientific | AAJ6195906 | |
Ketamine | Ketaved | NDC 50989-996-06 | |
LED Cold Light Source | Leica Mcrosystems | KL300LED | |
Luer Lock 1/16" Tubing Adapters | Fisher | 01-000-116 | |
Microscope | Olympus | BX51WI | |
Mini-series Optical Posts | Thorlabs | MS2R | |
MPG | Fisher Scientific | AAA1723230 | |
MXC-2.5 Rotatable probe Clamp | Siskiyou | 14030000E | |
NaCl | Fisher Scientific | 50-947-346 | |
petri dishes | Fisher Scientific | FB0875713A | |
Pressurized air | Airgas | AI Z300 | |
Quinine | Fisher Scientific | AC163720050 | |
Self Sticking Labeling Tape | Fisher Scientific | 159015R | |
Silicone Pinch Valve Tubing 1/32" x 1/16" o.d. (per foot) | Automate Scientific | 05-14 | |
Sola SM Light Engine | Lumencor | ||
Snap25-2A-GCaMP6s-D | JAX | 025111 | |
Student Fine Scissors | Fine Science Tools | 91460-11 | |
Surgical Probe | Roboz Surgical Store | RS-6067 | |
Surgical Probe Holder | Roboz Surgical Store | RS-6061 | |
Thread | Gütermann | 02776 | |
BD Intramedic Tubing | Fisher Scientific | 22-046941 | |
Two Stage Gas Regulator | Airgas | Y12FM244B580-AG | |
Tygon vinyl tubing – 1/16" | Automate Scientific | 05-11 | |
Valvelink8.2 digital/manual controller | Automate Scientific | 01-18 | |
Valvelink8.2 Pinch Valve Perfusion System | Automate Scientific | 17-pp-54 | |
Xylazine | Anased | NADA# 139-236 |