Extracellular vesicles present in blood have been suggested as novel biomarkers for various diseases. Here, we present a protocol for the isolation of large plasma membrane-derived microvesicles from peripheral blood samples and their subsequent analysis by conventional flow cytometry and Western Blotting.
The release of extracellular vesicles (EVs) including small endosomal-derived exosomes (Exos, diameter < 100 nm) and large plasma membrane-derived microvesicles (MVs, diameter > 100 nm) is a fundamental cellular process that occurs in all living cells. These vesicles transport proteins, lipids and nucleic acids specific for their cell of origin and in vitro studies have highlighted their importance as mediators of intercellular communication. EVs have been successfully isolated from various body fluids and especially EVs in blood have been identified as promising biomarkers for cancer or infectious diseases. In order to allow the study of MV subpopulations in blood, we present a protocol for the standardized isolation and characterization of MVs from peripheral blood samples. MVs are pelleted from EDTA-anticoagulated plasma samples by differential centrifugation and typically possess a diameter of 100 – 600 nm. Due to their larger size, they can easily be studied by flow cytometry, a technique that is routinely used in clinical diagnostics and available in most laboratories. Several examples for quality control assays of the isolated MVs will be given and markers that can be used for the discrimination of different MV subpopulations in blood will be presented.
In the last years many in vitro studies have demonstrated that extracellular vesicles (EVs) play an important role in intercellular communication. Living cells constantly shed vesicles which differ in size, content and biogenesis. The best studied EVs are exosomes which originate from the endosomal system where they are stored as intraluminal vesicles in multivesicular bodies. Once the latter fuse with the plasma membrane, the contained vesicles are released as exosomes (Exos, diameter 30 – 100 nm1). A second population of EV which has gained increasing attention in the last years are large microvesicles (MVs, diameter 100 – 1,000 nm) which bud off directly from the plasma membrane 2.
Both types of vesicles are surrounded by a lipid bilayer and contain nucleic acids, e.g., DNA, mRNA or miRNA 3–5, and a plethora of proteins which they can transfer to neighboring cells . While in general the protein composition of the vesicles reflects the state of the cell of origin, some proteins seem to be selectively targeted and enriched on EVs 1. A major research interest is to characterize EVs from abnormal and diseased cells in order to define specific EV signatures which might allow the use of EVs as novel biomarkers. Especially in cancer, in which often the tumor itself is not easily accessible, liquid biopsies targeting tumor-specific EVs in blood might allow monitoring of therapy responses or help characterizing the primary tumor without the need for invasive procedures 6.
Indeed, EVs have already been successfully isolated from various body fluids including urine 7, CSF 8, breast milk 9 or blood 10. Several studies identified changes in EV counts and composition in different human diseases. For example, in sepsis patients the number of pro-coagulant MVs is significantly increased compared to healthy individuals 11. Also in patients with severe cerebral malaria an increase in total MVs in blood can be observed and counts of platelet-derived MVs correlate with coma depth and thrombocytopenia 12. Other studies report elevated numbers of endothelium-derived vesicles in patients with systemic lupus erythematosus or heart failure and in the case of the latter, this correlates with a higher probability of cardiovascular events 13,14.
Especially in cancer, EVs in blood are currently discussed as novel biomarkers with diagnostic and prognostic value. Levels of MVs expressing tumor-associated proteins such as MUC1, EGFR or FAK seem to be elevated in the blood of breast cancer patients 15,16. Also for Exos, recent studies have shown that blood-derived Exos carrying tumor-specific antigens such as Glypican-1 for pancreatic cancer or Del-1 for breast cancer allow early disease detection with high specificity and sensitivity 17,18. Additionally, serum-derived tumor Exos may contain DNA which can be used for detection of mutations such as KRAS and p53 which suggests their use for therapy prediction 19. Recent advances have shown that analysis of Exos in blood of glioblastoma patients using a specific microfluidic chip allows monitoring of therapy 20. Taken together, these findings imply that analysis of disease-specific subpopulations of vesicles gives valuable information about diagnosis, prognosis as well as therapeutic options and success.
However, isolation and analysis of Exos from blood is time-consuming, requires special lab equipment and therefore is not yet suited for routine clinical diagnostics. In contrast, MVs can be isolated much faster and, due to their larger size, can be easily analyzed by flow cytometry without the need to couple them to latex beads as it is necessary for Exos 18,21. Thus, here we present a protocol that can be used for the standardized isolation of MVs from blood samples and the subsequent characterization of MV subpopulations by flow cytometry. This protocol will allow the further study and in depth characterization of MV profiles in large patient groups which will be required in order to use MVs for everyday clinical diagnostics.
All experiments including human subjects have been approved by the local ethics committee (approval no. 3/2/14). For the choice of patients it should be noted that several factors such as age, sex, current therapy regimens and many more may influence MV composition in blood and therefore should be taken into consideration prior to sample collection 22,23.
1. Preparation of Plasma Samples
2. Isolation of MVs
3. Characterization of MVs by Flow Cytometry
4. Characterization of MVs by Western Blotting
In order to quantify the yield of MVs that can be isolated following the described protocol, we calculated the amount of MVs isolated from blood samples of 10 donors. The MV yield, which was assessed in a Lowry protein assay, ranged from 10 up to 30 µg with a mean of 19.2 µg MVs per mL blood (Table 1). The particle concentration determined by nanoparticle tracking analysis (NTA) ranged from 1.66 x 109 to 2.36 x 1010 with a mean of 5.9 x 109 particles per mL plasma sample (Table 2). Further characterization of the MVs by transmission electron microscopy revealed a population of vesicles with a diameter > 100 nm that were surrounded by a lipid bilayer and did not contain any cell organelles (Figure 1A). NTA confirmed that the size of the isolated MVs ranged from 100 up to 600 nm (Figure 1B) and the mean MV size was 201 nm (Figure 1C). Staining for typical MV and Exo markers by Western Blotting demonstrated that the isolated MVs were positive for Tubulin and only showed a slight expression of CD9 and CD81, while Exos were negative for Tubulin and enriched in CD9 and CD81 (Figure 2).
Analysis of the isolated MVs by flow cytometry (Figure 3A) revealed a defined vesicle population that could be gated using the same parameters normally used for MVs isolated from cell culture supernatants and that was clearly different from the background signal obtained by the measurement of PBS + 1% vesicles-depleted FCS without addition of MVs (Figure 3B). In order to analyze the different MV populations present in blood, MVs were stained with established markers for the different blood cell populations, e.g., CD62P for platelet-derived MVs, CD45 for leukocyte-derived MVs, CD235a for red blood cell-derived MVs and CD62E for endothelial cell-derived MVs (Figure 4). This characterization showed that the percentage of MV subpopulations differed among the investigated donor blood samples, while the majority of MVs seemed to be shed by platelets in all samples.
Figure 1: Size Distribution of MVs Isolated from Peripheral Blood. A, Isolated MVs were visualized by transmission electron microscopy. B, Representative nanoparticle tracking analysis (NTA) of MVs illustrating the size distribution of the vesicles. C, The mean MV size from 10 independent preparations was measured by NTA (mean). Please click here to view a larger version of this figure.
Figure 2: Characterization of Isolated MVs by Western Blotting. Differential protein expression on the isolated MVs and Exos from two donors was visualized by Western Blotting. Please click here to view a larger version of this figure.
Figure 3: Analysis of MVs by Flow Cytometry. A, MVs are first visualized on forward (FSC) versus sidescatter (SSC) plots to gate on the respective MV population. Subsequently, these MVs are characterized for the antigen of interest by using fluorescently labeled antibodies directed against the antigen. B, Typical FSC versus SSC plots for MVs isolated from the plasma of two donors. As comparison, a typical plot for tumor cell-derived MVs from A549 lung cancer cells isolated from cell culture supernatant as well as a negative control using only PBS + 1% vesicle-depleted FCS without MVs are shown on the right. Please click here to view a larger version of this figure.
Figure 4: Characterization of Isolated MVs by Flow Cytometry. MVs from three donors were characterized for the expression of established blood cell markers (red) by flow cytometry. The respective isotype controls are shown in grey. Please click here to view a larger version of this figure.
Sample | MVs/mL blood [µg] |
#1 | 29.4 |
#2 | 10.3 |
#3 | 15.2 |
#4 | 31.1 |
#5 | 18.8 |
#6 | 22.7 |
#7 | 19.1 |
#8 | 18.7 |
#9 | 15.0 |
#10 | 11.9 |
Table 1: MV Protein Yield from Peripheral Blood Samples. Shown is the amount of MVs per mL peripheral blood that was drawn from 10 donors. MV yields were quantified by Lowry assay.
Sample | MVs/mL plasma [particle count] |
#1 | 6.42E+09 |
#2 | 2.36E+10 |
#3 | 1.88E+09 |
#4 | 6.51E+09 |
#5 | 3.48E+09 |
#6 | 4.57E+09 |
#7 | 2.09E+09 |
#8 | 1.66E+09 |
#9 | 2.54E+09 |
#10 | 6.20E+09 |
Table 2: MV Particle Yield from Peripheral Blood Samples. MV were isolated from plasma samples of 10 donors and particle counts were determined by nanoparticle tracking analysis. Shown is the mean value from three independent measurements.
Recent studies on EVs in blood have demonstrated that EV composition and counts change during the cause of several diseases. Therefore, the analysis and further characterization of these EVs are of high interest to further assess their potential use as disease biomarkers for diagnosis and prognosis or to evaluate therapy responses. The protocol we present here allows the isolation of vesicles with a diameter of up to 600 nm which do not contain any cell organelles. These observations are in line with the current definition of MVs and exclude the presence of apoptotic bodies 2. Using Western Blotting, we were able to demonstrate that the isolated MVs show a high expression of Tubulin, while the tetraspanins CD9 and CD81 that are often used as Exo markers were only slightly expressed. This confirms that MVs differ from Exos and fits to recent in-depth characterization and comparison of both EV populations by proteomics 25.
During acquisition of blood samples, it is critical to keep the time between venipuncture and plasma preparation as short as possible in order to prevent MV degradation. Moreover, prolonged storage of blood samples could lead to the activation of blood cells causing enhanced MV shedding and ultimately apoptosis which results in the release of apoptotic bodies. Another important consideration for MV isolation is to prevent contaminations of MV preparations with plasma proteins or smaller Exos. Therefore, it is critical to remove as much of the supernatant as possible after spinning down the MVs at 14,000 x g. Since the pellet is normally visible and tightly attached to the wall of the tube, the supernatant can be easily removed with a pipette tip. In contrast to Exos which tend to form aggregates during preparation by high speed ultracentrifugation and are often hard to resuspend, this problem does not occur with MVs.
Our study shows that it is possible to characterize MV subpopulations present in blood by flow cytometry. Although the detection limit of most flow cytometers is around 200 – 300 nm, MVs were reproducibly measured in donor as well as cell culture samples with the same parameters of analysis and gates that clearly allowed their distinction from background signals. It is important to verify prior to the measurements that the PBS used for the analyses does not contain any contaminating particles that could cause a high background during flow cytometry (Figure 3). Although some smaller MVs might not be captured in a flow cytometric approach, we detected MVs from all major blood cell populations (e.g., platelets, red blood cells, leukocytes, endothelial cells). In our analyses we used standard markers for the different blood cells that have been previously found on MVs 26–29. It should be noted that in order to obtain the best possible results by flow cytometry, the amount and concentration of all antibodies should be titrated on a MV sample expressing the antigen of interest. If specific MV subpopulations in blood shall be identified with higher specificity, it is possible to perform double staining against two different antigens present on the respective MVs and only consider all double positive MVs for subsequent analyses 23. Currently, there are efforts to define a standard range of MV subpopulations in blood of healthy individuals 23,30. These studies have already shown that platelet-derived MVs constitute the largest population of MVs in blood which is in correspondence with our observations.
One advantage of flow cytometry to characterize MV samples is that this method is already well established for diagnostic purposes in most clinical centers which would allow the possible use of MVs as biomarkers in everyday clinical diagnostics. Previous studies on EVs in blood which have mostly focused on smaller Exos, rely on either specific sorting procedures to selectively analyze the desired Exo target population 31,32 or require a time-consuming (2 days) isolation process with coupling of Exos to Latex beads prior to analysis 18. Our own unpublished observations suggest that the flow cytometric analysis of MVs from whole blood preparations even allows the detection of MVs such as tumor-derived MVs without any such selection processes.
Taken together, the protocol presented here allows the fast isolation of MVs from peripheral blood samples with standard lab equipment and their subsequent characterization using flow cytometry and Western Blotting. The whole process can be performed in around 2 h which will facilitate future studies on MV profiles in patients' blood that are required to assess the potential of MVs as disease biomarkers.
The authors have nothing to disclose.
The authors acknowledge Meike Schaffrinski for excellent technical assistance. We would like to thank the following people for their help in the collection of peripheral blood samples (all from University Medical Center Göttingen): Henrietta Vida (Dept. of Transfusion Medicine), Kia Homayounfar, Lena-Christin Conradi (Dept. of General, Visceral and Pediatric Surgery), Leila Siam, Bawarjan Schatlo (Dept. of Neurosurgery), Hendrik A. Wolff, Martin Canis (Dept. of Otorhinolaryngology, Head and Neck Surgery) as well as all employees of the interdisciplinary short-term oncology. We acknowledge Dirk Wenzel (Max Planck Institute for Biophysical Chemistry, Göttingen) for his help with the electron microscopy of MVs.
The study was funded by the German Ministry of Education and Research (BMBF) project MetastaSys (grant no. 0316173) as well as the German Cancer Aid (grant no. 109615).
butterfly needle (21 gauge) | Hospira Deutschland GmbH | 490P29201 | |
Bovine serum albumin Fraction V | Roth | 8076.3 | For 10x TBS weigh 24.2 g Tris base and 80 g NaCl, ad 1 L H2O and adjust pH to 7.6 |
For 1x TBS-T mix 100 mL 10x TBS with 900 mL H2O and add 1 mL Tween-20 | |||
CD235a-PE | Beckman Coulter | A07792 | use 5µl for staining |
CD45-FITC | Beckman Coulter | 7782 | use 5µl for staining |
CD62E-PE | Biolegend | 336008 | use 0.8µg for staining |
CD62P-PE | Biolegend | 304905 | use 0.1µg for staining |
CD81 antibody | Biolegend | 349501 | 1:2000 in 5%BSA in TBS-T; use non-reducing conditions for Western Blotting |
CD9 antibody | Immunotools | 21270091 | 1:1000 in 5%BSA in TBS-T; use non-reducing conditions for Western Blotting |
Chemiluminescence imager ImageQuant LAS-4000 | Fujitsu Life Sciences | ||
DC protein assay kit II | Bio-Rad | 5000112 | |
ECL detection reagent | GE Healthcare | RPN2232 | |
EDTA vacutainers for blood collection | Sarstedt | 01.1605.001 | |
FACSCanto II | BD Biosciences | ||
fetal calf serum (FCS) | Invitrogen | 10091148 | heat-inactivated (30 min, 56°C) |
filter 0.22µm | Sarstedt | 83.1826.001 | |
HRP-coupled anti-mouse secondary antibody | santa cruz | sc-2005 | use 1:10,000 in 5% milk powder in TBS-T |
HRP-coupled anti-rabbit secondary antibody | santa cruz | sc-2004 | use 1:10,000 in 5% milk powder in TBS-T |
4x Laemmli loading buffer, Roti-Load 1 | Roth | K929.1 | |
microfuge SIGMA 1-15K | Sigma Laborzentrifugen | ||
milk powder (Blotting-Grade Blocker, nonfat dry milk) | BioRad | 170-6404 | |
multifuge 3 L-R | Heraeus | ||
NanoSight LM10 | NanoSight Ltd. | ||
PBS, w/o Ca and Mg | Pan biotech | P04-36500 | |
perfusor syringe 50 mL | Braun | 8728844F | |
Ponceau-S staining solution | PanReac AppliChem | A2935,0500 | |
rotor Sw32.1 Ti for ultracentrifugation (6x 17 mL) | Beckman Coulter | ||
rotor TLA-120.2 for ultracentrifugation (10x 1.5 mL) | Beckman Coulter | ||
tubes for flow cytometry (5 mL, round-bottom) | BD Biosciences | 352054 | |
tubes for ultracentrifugation (15 mL) | Beckman Coulter | 344061 | |
tubes for ultracentrifugation (11* 34 mm) | Beckman Coulter | 343778 | |
Tubulin antibody | Millipore | 05-829 | 1:5000 in 5%BSA in TBST |
ultracentrifuge Optima L-80 XP | Beckman Coulter | ||
ultracentrifuge TL-100 | Beckman Coulter | ||
valve filter Seraplas V15 | Sarstedt | 53,428 |