This article aims to describe a basic protocol for combining transcranial direct current stimulation (tDCS) with proton magnetic resonance spectroscopy (1H-MRS) measurements to investigate the effects of bilateral stimulation on primary motor cortex metabolism.
Transcranial direct current stimulation (tDCS) is a neuromodulation technique that has been increasingly used over the past decade in the treatment of neurological and psychiatric disorders such as stroke and depression. Yet, the mechanisms underlying its ability to modulate brain excitability to improve clinical symptoms remains poorly understood 33. To help improve this understanding, proton magnetic resonance spectroscopy (1H-MRS) can be used as it allows the in vivo quantification of brain metabolites such as γ-aminobutyric acid (GABA) and glutamate in a region-specific manner 41. In fact, a recent study demonstrated that 1H-MRS is indeed a powerful means to better understand the effects of tDCS on neurotransmitter concentration 34. This article aims to describe the complete protocol for combining tDCS (NeuroConn MR compatible stimulator) with 1H-MRS at 3 T using a MEGA-PRESS sequence. We will describe the impact of a protocol that has shown great promise for the treatment of motor dysfunctions after stroke, which consists of bilateral stimulation of primary motor cortices 27,30,31. Methodological factors to consider and possible modifications to the protocol are also discussed.
The idea of applying electricity to the human brain to modulate its activity has been studied since ancient times. In fact, writings from as early as the 11th century have been found that describe the use of the torpedo electric fish in the treatment of epileptic seizures1. Yet, it is not until recently that non-invasive brain stimulation has received widespread interest in the scientific community as it was shown to produce modulatory effects on cognitive function and motor response2. While transcranial magnetic stimulation (TMS) has been extensively studied since the early 1980's3, recent interest in transcranial direct current stimulation (tDCS) has increased as it is now considered a viable treatment option for a wide range of neuropathologies, such as stroke4, alcohol addiction5, and chronic pain6. tDCS has many advantages over neurostimulation techniques like TMS, for example, since it is relatively inexpensive, painless, well tolerated by patients, and portable, thus making it possible to administer at bedside7. In fact, only a small percentage of patients experience a mild tingling sensation during stimulation8. However, this sensation usually disappears after a few seconds9. Consequently, tDCS allows robust double-blind, sham-controlled studies since a majority of participants cannot differentiate sham stimulation from real stimulation9,10.
tDCS involves the induction of a constant low-amperage electric current (1-2 mA) applied to the cortex via surface electrodes positioned on the scalp of the subject. The electrodes are usually placed into saline-soaked sponges or directly on the scalp with an EEG-type paste. To conduct a tDCS study, four main parameters need to be controlled by the experimenter: 1) the duration of stimulation; 2) the intensity of stimulation; 3) the electrode size; and 4) the electrode montage. In standard protocols, the “active” electrode is positioned over the region of interest while the reference electrode is usually placed over the supraorbital region. The current flows from the positively charged anode towards the negatively charged cathode. The effect of tDCS on primary motor cortex (M1) is determined by the polarity of the stimulation where anodal stimulation enhances the excitability of a population of neurons and cathodal stimulation reduces it 11. Unlike TMS, the induced current is insufficient to produce action potentials in cortical neurons. The changes in cortical excitability are believed to be due to the modulation of the membrane neuronal threshold leading to either the hyperpolarization of membrane potentials or a facilitation of depolarization of neurons depending on the direction of the current flow 8,11. The duration of the excitability changes can persist for up to 90 min after the offset of stimulation, depending on stimulation duration 11,12.
tDCS and Motor Rehabilitation
The M1 has been extensively used as a target of stimulation since excitability changes elicited by tDCS can be quantified through motor evoked potentials (MEPs) induced by single pulse TMS 3. Early studies showing the possibility of measuring polarity-specific excitability changes induced by tDCS have used M1 as a target of stimulation 11,12. Since then, M1 has remained one of the primary targets of tDCS in studies involving both clinical populations and healthy subjects because of its importance in motor function, memory formation, and consolidation of motor skills 12.
The brain relies on a complex interaction between motor regions of both hemispheres to perform a movement 14. When one area is damaged, after suffering a stroke for example, inter-hemispheric interactions are altered. Studies on brain plasticity have shown that the motor areas of the brain adapt to this modification in different ways 15. First, the intact, surrounding regions of the damaged area can become overactived, leading to inhibition of the damaged area – a process called intra-hemispheric inhibition. Second, the homologous region of the damaged area can become overactivated and exert inhibition on the injured hemisphere – a process called inter-hemispheric inhibition. The affected M1 can therefore be twice penalized: first by the lesion and second by the inhibition coming from both the unaffected M1 and the surrounding region of the affected M1 16. A recent study has shown that increased excitability in the unaffected hemisphere is linked to slower rehabilitation 17, which has been described as maladaptive inter-hemispheric competition 18.
Understanding the plasticity occurring after a stroke may lead to the development of neuromodulation protocols that can restore interhemispheric interactions 19. Three main tDCS treatments have been proposed in patients with motor deficits following stroke 20,21. The first treatment aims to reactivate the injured motor cortex by unilateral anodal stimulation (a-tDCS). In this case, stimulation aims at directly increasing activity in perilesional areas, which are believed to be essential for recovery. In fact, studies have shown improvement of the paretic upper or lower limb following this treatment 22-26. The second treatment was developed with the aim of reducing the over-activation of the contralesional hemisphere by applying unilateral cathodal tDCS (c-tDCS) over the intact M1. Here, stimulation aims at indirectly increasing activity in perilesional areas through interhemispehric interactions. Results from these studies have shown improvement of motor function after c-tDCS 4,27-29. Finally, the third treatment aims at combining the excitatory effects of a-tDCS over the injured M1 with the inhibitory effects of c-tDCS over the unaffected M1 using bilateral tDCS. Results have shown improvements in motor function after bilateral tDCS 27,30,31. Moreover, one study demonstrated greater improvements following bilateral tDCS compared to both unilateral methods 32.
Physiological Mechanisms of tDCS
Despite the increasing use of tDCS in the treatment of stroke, the physiological mechanism underlying its effects remains unknown 33. A better understanding of the physiological effects could help develop better treatment options and could lead to standardized protocols. As mentioned earlier, the effects of tDCS can last for up to 90 min after the offset of stimulation 11,12. Therefore, hyperpolarization/depolarization processes cannot completely explain long lasting effects 33,34. Different hypotheses have been suggested regarding the physiological mechanism underlying tDCS after-effects on M1 including changes in neurotransmitter release, protein synthesis, ion channel function, or receptor activity 34,35. Insights into this matter were first acquired through pharmacological studies showing a suppression of the after effects of anodal and cathodal stimulation on M1 excitability by the glutamatergic N-methyl-D-aspartate (NMDA) receptor antagonist dextromethorphan36,37 whereas the opposite effect was shown using a NMDA receptor agonist38. NMDA receptors are thought to be involved in learning and memory function through long term potentiation (LTP) and long term depression (LTD), both mediated by glutamatergic and GABAergic neurons39,40. Animal studies are in line with this hypothesis as they have shown that a-tDCS induces LTP13.
Despite the important progress made in our understanding of the mechanisms of action underlying tDCS effects, pharmacological protocols present important limitations. Indeed, drug action cannot be as spatially specific as tDCS, especially in the context of human experimentation, and the mechanism of action of their effects is mostly due to post-synaptic receptors 34. Therefore, there is a need to investigate more directly the effects of tDCS on the human brain. Proton magnetic resonance spectroscopy (1H-MRS) is a good candidate as it allows non-invasive in vivo detection of neurotransmitter concentrations in a specific region of interest. This method is based on the principle that every proton-containing neurochemical in the brain has a specific molecular structure and consequently, produces chemically specific resonances that can be detected by 1H-MRS 41. The acquired signal from the brain’s volume of interest is generated from all protons that resonate between 1 and 5 ppm. The acquired neurochemicals are represented on a spectrum and plotted as a function of their chemical shift with some clearly distinguishable peaks, but where many resonances from the different neurochemicals overlap. The signal intensity of each peak is proportional to the concentration of the neurometabolite 41. The amount of neurochemicals that can be quantified depends on the strength of the magnetic field 42,43. However, low-concentration metabolites, which are obscured by very strong resonances, are hard to quantify at lower field strength such as 3 T. One way to obtain information about such overlapping signals is to remove the strong resonances via spectral editing. One of such techniques is a MEGA-PRESS sequence, which allows detection of γ-aminobutyric acid (GABA) signals 44,45.
Only a few studies have investigated the effect of tDCS on the brain metabolism using 1H-MRS in motor 34,46 and non-motor regions47. Stagg and collaborators 34 assessed the effects of a-tDCS, c-tDCS, and sham stimulation on M1 metabolism. They found a significant reduction in GABA concentration following a-tDCS, and a significant reduction of glutamate+glutamine (Glx) and GABA following c-tDCS. In another study, it was reported that the amount of changes in GABA concentration induced by a-tDCS over M1 was related to motor learning 46.
These studies highlight the potential of combining 1H-MRS with tDCS to increase our understanding of the physiological mechanism underlying the effect of tDCS on motor function. In addition, the use of clinical protocols such as a-tDCS and c-tDCS over M1 is useful because their behavioral effects are well studied and can be directly related to physiological results. Therefore, a standard protocol for combining bilateral tDCS and 1H-MRS is demonstrated in healthy participants using a 3 T MRI system. Bihemispheric tDCS is presented to contrast data with a previous MRS study where unilateral cathodal or unilateral anodal tDCS were applied over motor cortex 34. The protocol is described specifically for stimulation with a NeuroConn stimulator in a Siemens 3 T scanner performing MEGA-PRESS 1H-MRS.
The study was approved by the Research and Community Ethics Boards of Unité de Neuroimagerie Fonctionnelle and University of Montréal and was done in compliance with the code of ethics as stated in the Declaration of Helsinki. All subjects gave written informed consent following careful screening for MRI compatibility and were financially compensated for their participation.
1. tDCS Material
2. Planning of the Conditions for Stimulation
3. Consenting the Participants
4. Measurements for Electrodes Placement
5. Placement of Electrodes
6. tDCS Test Outside the Scanner Room
7. tDCS Setup
8. MRI Scan Preparation
9. Pre-tDCS 1H-MRS Session
10. tDCS Procedure
11. Post-tDCS 1H-MRS Session
12. Analysis of the 1H-MRS Data
Figure 6 shows the position of the VOI located on the representation of hand in M1 where all MRS measures were taken. In figure 6D, a 3D visualization shows a clear representation of the tDCS electrodes positioned on the scalp over the putative primary motor cortex. Figure 7 shows representative “EDIT OFF” and difference (“DIFF”) spectra acquired in M1. Peaks corresponding to Glx, GABA+MM as well as NAA can be clearly seen.
Figure 8 shows the percentage of change between the MRS acquisition pre-tDCS and post-tDCS for the three different conditions in a single participant. Results from the post-tDCS session are separated into two time points to illustrate the evolution of change over time. Figure 8a shows the percentage of change for Glx. For sham stimulation, Glx concentration displays no notable modulation. For bilateral stimulation 1 (left anodal, right cathodal), again no notable modulation of Glx is observed; however, modulation of the concentration over time is opposite to what is observed in the sham stimulation. Finally, regarding bilateral stimulation 2 (left cathodal, right anodal), a similar pattern is observed to the sham stimulation but with a notable enhancement of the Glx concentration in the second time-point following stimulation.
Figure 8b shows the percentage of change in the concentration of GABA in relation to the condition of stimulation. For the sham stimulation, GABA concentration displays no notable modulation. However, a slight reduction is observed at both time points. The modulation of GABA following the sham stimulation is more important than for the Glx,. In contrast, a notable increase of GABA concentration is seen in the second-time point after bilateral stimulation 1 (left anode, right cathode). Finally, a similar pattern of change to the sham stimulation is observed for bilateral stimulation 2 (left cathode, right anode).
Figure 9 shows the obtained spectra from two different participants. Figure 9a shows a spectrum of good quality with an acceptable lipids signal. Figure 9b shows a spectrum with large lipids signals, which was excluded after visual inspection. Finally, figure 10 shows displacement of the location of the voxel of interest following 5 mm participant movement.
Figure 1: Materials. 1) Saline solution; 2) Conductive paste; 3) Electrode gel; 4) Alcohol prepping pad; 5) Measuring tape; 6) EEG pencil; 7) Rubber bands; 8) Inner box; 9) tDCS device; 10) Outer box; 11) Inner box cable; 12) Outer box cable; 13) Electrodes; 14) Long box cable
Figure 2: tDCS device Image of the positioning of the buttons on the specific tDCS device used in the present protocol. These buttons are used to pre-set the different settings.
Figure 3: Time course of tDCS conditions. A) Time course of the active tDCS condition. After the pre-tDCS metabolite acquisition, turn on the tDCS device and ramp-up the current for 15 sec until an intensity of 1 mA is reached. Stimulate for 20 min and ramp-down the current for 15 sec until an intensity of 0 mA is reached. Do not turn off the tDCS device and proceed to the post-stimulation metabolite acquisition. B) Time course of the sham tDCS condition. After the pre-tDCS metabolite acquisition, turn on the tDCS device and ramp-up the current for 15 sec until an intensity of 1 mA is obtained. Stimulate for 15 sec (the minimum time available on the current device) and ramp-down the current for 15 sec until an intensity of 0 mA is reached. Wait for 20 min. Do not turn off the tDCS device and proceed to the post-stimulation metabolite acquisition.
Figure 4: Electrode positioning A) 10/20 international system landmarks used for the identification of C3 and C4. The vertex (Cz) corresponds to 50% of the distance between the nasion and the inion, and 50% of the distance between the two preauricular points. B) C3 and C4 correspond to 20% of the total distance between the preauricular points, measured from the vertex point. Make sure to leave at least 8 cm of distance between both electrodes.
Figure 5: Schematic view of the MR room. Placement of the materials in the MR scanning and console rooms. It is essential to follow the protocol for the positioning of the different parts of the device in order to obtain a MR signal of good quality and for safety purposes.
Figure 6: VOI placement. Position of the VOI (30 x 30 x 30 mm3) over the left hand area of M1 in (A) sagittal, (B) coronal, and (C) axial slices. 3D visualization of the positioning of the electrodes is shown in (D).
Figure 7: 1H-MRS metabolite spectrum. Representative (A) “EDIT OFF” and (B) difference (“DIFF”) spectra acquired with the MEGA-PRESS sequence 44,45 including the raw data, the fit from LCModel and the residuals. Cr: total creatine (creatine + phosphocreatine (Cr-CH3 + PCr-CH3)); NAA: N-acetyl-aspartate + NAAG (sNAA + NAAG); Glx : glutamate + glutamine (Glu + Gln); GABA + MM: γ-aminobutyric acid + macromolecules
Figure 8: Effects of bilateral tDCS on Glx and GABA for a single subject. A) tDCS effects on Glx concentration are shown for the three conditions. Results are expressed as percentage of change between the pre-tDCS acquisition and the two post stimulation acquisitions. B) tDCS effects on GABA concentration are shown for the three conditions. Results are expressed as percentage of change between the pre-tDCS acquisition and the two post stimulation acquisitions. Sham: Bilateral, Bilateral 1: left anode, right cathode; Bilateral 2: left cathode, right anode
Figure 9: Visual inspection of the spectra A) Example of a good quality data. The figure shows the ”EDIT OFF” and ”DIFF” spectra with an acceptable amount of lipids. SNR from analysis of ”DIFF” spectra: 56 CRLB of the GABA signal: 14% Lw of tCr-CH3 at 3 ppm: 5.6 Hz. B) Example of a poor quality data caused by excessive movement of the participant. The figure shows the ”EDIT OFF” and ”DIFF” spectra. SNR from analysis of ”DIFF” spectra: 39 CRLB of the GABA signal: 47% Lw of tCr-CH3 at 3 ppm: 4.4 Hz
Figure 10: VOI location after movement Position of the VOI (30 x 30 x 30 mm3) over the left hand area of M1 in (A) sagittal and (B) coronal slices after a movement of 5 mm. Inclusion of the cranial bones and the meninges in the box would lead to inclusion of lipids and elimination of the scan. The light grey square shows the initial position of the VOI.
The present paper aimed to describe a standard protocol for combining tDCS and 1H-MRS using a 3 T scanner. In the next section, methodological factors will be discussed.
Critical Steps
Contraindications Screening
Previous to the experiment, it is crucial to screen participants for any contraindication regarding the use of tDCS and 1H-MRS. The use of the following exclusion criteria is recommended for tDCS: a psychiatric or neurological history, the presence of a pacemaker, a piece of metal implanted in the skull, a history of fainting, a history of seizures or a history of substance abuse. Because only metabolites from the left M1 will be acquired, the exclusion of left handed participants from the study is recommended. In fact, a recent study has shown differential interhemispheric inhibition between the dominant and non-dominant hemispheres depending on the hand preference, which could modulate the effect of stimulation 15. Moreover, before starting the experiment, check for any lesion on the scalp and ask for any skin disease 56. If there is a lesion present, try to avoid stimulating directly the affected area. It is also recommended to inspect the skin after stimulation 57. Also, screen for the presence of allergies to any of the products used for electrode montage. For 1H-MRS, the exclusion criteria should be the same as for any magnetic resonance imaging study including a careful screening of any prior surgeries for the presence of metal in the body.
It is also important to determine if the participant felt any discomfort during tDCS stimulation. Again, after the experiment, participant should be asked about any side effects. It is possible to use a record-form including the most reported side effects to quantify their presence in relation to the protocol (see 58 for an example). The most reported side effects are mild tingling (70.6%), moderate fatigue (35.3%), a light sensation of itching under the electrodes (30.4%), and slight burning sensation (21.6%) 58.
Movement Artefacts Reduction
Movement of the participant in the scanner is a major issue during 1H-MRS as this is one of the main factors affecting the quality of the data 59. As shown in figure 10, a movement of the subject (from 1 mm to 5 mm) can lead to large lipids signal in the spectrum thus altering the quality of the data and consequently, to the exclusion of this acquisition from the data. Therefore, it is crucial to carefully explain to the participant the importance of head stability during the entire scan. During the positioning of the participant in the scanner, it is important to ask the subject to find the most comfortable position to avoid any further movement. During positioning of the VOI, it is also important to notify the participant that even though the scan is silent, it is essential to remain still.
In addition, the duration of the experiment is an important factor to help minimize total amount of movement. First, it is important to use an optimal length for the anatomical sequence, as short as possible, but long enough to obtain good quality images for placement of the VOI. Second, the use of a short sequence of metabolite acquisition is recommended before tDCS. Third, in order to capture the temporal course of stimulation effects, the use of a longer sequence of acquisition after stimulation is advised. Fourth, compare pre- and post-experiment localizer images to estimate participant movement.
Analysis
The MEGA-PRESS sequence44,45 is used to acquire localized, water suppressed, and edited spectra. A spatial localization in PRESS is performed using a 90° Hamming-filtered sync pulse (bandwidth time product = 8.75, duration = 2.12 msec, bandwidth (FWHM) = 4.2 kHz) and two 180° mao pulses (duration = 5.25 msec, bandwidth = 1.2 kHz). All localization pulses are executed at 3 ppm. A selective double-banded 180° Shinnar-Le Roux pulse is applied at 1.9, the resonance frequency of β–CH2 of GABA, and 4.7 ppm alternating with 7.5 and 4.7 ppm. Additional water suppression using variable power with optimized relaxation delays (VAPOR) and outer volume suppression, OVS50 were adapted for the human 3 T system and incorporated prior to MEGA-PRESS and are used to suppress water and to improve the localization of the VOI. When the selective pulse is applied at 1.9 ppm, the resonance at 1.9 ppm and the resonances within the bandwidth of the pulse are inverted causing refocusing of γ–CH2 resonance of GABA (“EDIT ON”). When the selective pulse is applied at 7.5 ppm, the usual spectrum at TE of 68 msec is obtained (“EDIT OFF”) with the γ–CH2 resonance of GABA phase modulated. The subtraction of signals from alternate scans results in selective observation of outer lines of GABA triplet and cancelation of the total creatine (creatine + phosphocreatine) resonance (“DIFF”). Due to the bandwidth of the inversion pulse, additional resonances of NAA, Glu + Gln, and macromolecules are also observed. The whole protocol is divided into four interleaved acquisitions and the frequency is updated before each individual scan to minimize the frequency drifts due to the hardware. The interleaved acquisition and single FID storage allows the correction of frequency and phase in post-processing.
The analysis method described in the protocol allows the calculation of the best fit of the experimental spectrum as a linear combination of model spectra. Model spectra in the basis set for “EDIT OFF” spectra were simulated based on density matrix formalism 59 and known chemical shifts and J couplings 60, and included the following: acetyl moiety of N-acetylaspartate (sNAA), alanine (Ala), ascorbate (Asc), aspartate (Asp), aspartate moiety of NAA (mNAA), CH2 group of Cr (Cr-CH2), CH3 group of Cr (Cr-CH2), CH2 group of PCr (PCr-CH2), CH3 group of PCr (PCr-CH2), GABA, glucose (Glc), Glu, Gln, glycerophosphorylcholine (GPC), glycine (Gly), glutathione (GSH), lactate (Lac), myo-inositol (mI), N-acetylaspartylglutamate (NAAG), phosphorylcholine (PCho), phosphorylethanolamine (PE), scyllo-inositol (sI), and taurine.
The basis set for “DIFF” spectra was generated from experimentally measured spectra of four 100 mM solutions of NAA, GABA, Glu, and Gln (600 ml spherical glass flasks) using the same parameters and scanner as for in vivo experiments. Each solution additionally contained K2HPO4 (72 mM), KH2PO4 (28 mM), sodium azide (0.1 mM), 3-(trimethylsilyl)-1-propanesulfonic acid sodium salt (TSP; 2 mM), formate (200 mM; optional), and distilled water. The basis set spectra were acquired at the physiological temperature of 37°C and every effort was made to minimize cooling (~1°C within the 15 of acquisition) by preheating the phantoms in a large water tank before placing each one in a smaller water-filled isolated plastic container, which was placed in the coil. Temperature and pH are particularly important in spectroscopy because they affect the chemical shift of the metabolites. Additionally, for both “EDIT OFF” and “DIFF” spectra, basis sets included a metabolite-nulled macromolecular spectrum experimentally measured from 10 subjects from the occipital cortex using the inversion-recovery (inversion time, TI = 760 msec) technique using the same parameters as the regular MEGA-PRESS acquisition (except for TR = 2.7 s) 61.
Phantom Testing
Testing the procedure on a 100 mM GABA phantom with and without the tDCS stimulator that will be used on participants with the exact scanner and sequence parameters is strongly advised prior to the first participant being studied. The procedure should include a localizer sequence, an anatomical sequence (i.e. MPRAGE), a line-width scan and 16 “EDIT ON” and “EDIT OFF” scans. This should be repeated if stimulator, stimulation parameters or scanners are changed. In order to investigate the presence of artefacts on the signal, one should review spectra for changes in SNR with and without the tDCS simulator, presence of spikes and noise at certain frequencies, and the SNR values and any important artefact on the anatomical images.
Possible Modifications to the Protocol
1H-MRS Parameters
To acquire metabolite concentrations using 1H-MRS, it is necessary to localize a specific region and excite signals in this volume 35. In the present paper, the procedure for the placement of a single VOI over left M1 was described. However, many different modifications to this protocol can be applied. Successful measurement of metabolite concentrations have been demonstrated in various cortical and subcortical regions, such as the prefrontal cortex 62, hippocampus 63, cerebellum striatum and pons 64, visual cortex 66, and auditory cortex 67. The size of the VOI can also differ as a function of the region of interest, but the volume typically ranges between 3 and 27 cm3 68. However, it is hard to obtain concentration of low-concentration metabolites such as GABA from voxels smaller than 20 cm3. An important issue is to make sure to avoid any contact of the VOI with the cranial bones, meninges, and extra-cerebral cerebrospinal fluid. In smaller brains, the VOI might include part of the left lateral ventricle. In this case, the inclusion of the ventricle is preferable over the inclusion of cranial bones.
Additionally, depending on the selected acquisition sequence, different metabolites can be quantified 69. Previous methods, such as the Point-RE-Solved spectroscopy (PRESS) sequence 70 and stimulated echo acquisition mode (STEAM) 71, did not allow quantification of GABA at 1.5 T. However, because of the polarity-specific effect of tDCS on cortical excitability, the quantification of both excitatory (glutamate) and inhibitory (GABA) neurotransmitters is essential. In the present protocol, the use of the MEGA-PRESS spectral editing sequence 44,45 was shown, which allows the quantification of the major neurochemicals, including GABA (see figure 6). Other sequences allowing GABA quantification, such as ultra-short TE MRS and J-resolved MRS, have been developed over the last few years (see 41 for a review).
Finally, since metabolite concentrations are usually expressed as a ratio in relation to another metabolite (relative concentration), the choice of the reference metabolite is highly important, and particularly so in studies employing clinical populations 69. The most commonly used reference metabolites are tCr and NAA, as their concentrations are found to be relatively stable in the human brain. It should be noted it is also possible to use an absolute quantification of metabolites which requires referencing to either an external (e.g., phantom) or internal signal (e.g., water signal) 68. The use of an internal water reference requires an additional step of tissue correction since the water concentration and relaxation properties differ between grey matter, white matter and cerebrospinal fluid (CSF).72 The tissue correction can be performed either using the estimated tissue composition in the VOI of all participants or using subject specific tissue composition from segmentation 73. Additionally, it should be noted that tDCS carries the theoretical risk of inducing oedema, which could have a minor impact on water concentrations. However, Nitsche and collaborators 74 directly assessed this specific concern and showed no evidence of oedema following tDCS on the frontal cortex. Consequently, the use of a water reference is considered a viable option.
tDCS Parameters
Different electrodes sizes can be used 9 depending on the region of stimulation and the desired focality of stimulation 75,76. Da Silva and collaborators 56 provide a comprehensive description of the different types of electrodes that are currently available for tDCS. Furthermore, as described in the present paper, 1H-MRS is a useful technique that can be used to verify the underlying mechanisms of action of specific tDCS protocols that have been shown to improve symptoms in different clinical populations. Electrode positioning and duration of stimulation can be modified to investigate the effects of these specific tDCS protocols, such as those one used in the treatment of pain, depression, tinnitus, Parkinson’s, migraine, and alcohol abuse (see 77 for a description of the protocols). It should also be noted that if the impedance level is above 20 kΩ, the device will not stimulate and display an impedance error message on the screen. Different factors that can cause a high impedance include: 1) insufficient amount of conductive paste on the electrodes; 2) insufficient pressure on the electrodes; 3) bad contact with the scalp (caused by hair); 4) thickening of the scalp due to baldness; 5) problems with connections; 6) problems with wiring; (7) problems with stimulator; and 8) problems with electrodes.
It should also be noted that localization of primary motor cortex for tDCS could be made more precise. In the present protocol, the 10/20 EEG system is used, which may introduce slight misalignment between maximum electrical field projection and actual representation of M1 within precentral gyrus. One possible way to circumvent this issue is to use transcranial magnetic stimulation to precisely localize the hand representation in M1 through the TMS-induced muscular response. Availability of a TMS unit in the vicinity of the MR scanner may limit this possibility.
Safety of tDCS and 1H-MRS
Safety of tDCS
Multiple studies have shown that tDCS is a safe neuromodulation technique producing only minor adverse effects in both non-clinical and clinical populations 10. In fact, no case of epileptic seizure has ever been reported following tDCS 10. However, the safety of tDCS has yet to be investigated in children and pregnant women 78.
MR Compatible Materials
Caution should be taken when stimulating inside a MR scanner. All materials brought into the MR room must be MR compatible (see figure 1). Because of the possible interaction between the electric current produced by the tDCS and the MR scanner, tDCS should always be turned on, and the electrodes should remain connected, during the MR sequences described in the present protocol. Coiling of the wires under the head coil can produce artefacts and distortions in the signal. Moreover, improper connection of the wires could potentially produce a current strong enough to burn the participant 79. Finally, it is important to never disconnect the electrodes while the current is flowing as this might cause an unwanted high-voltage stimulation.
tDCS-MRS Technique
Using tDCS in conjunction with MRS offers the possibility to better understand the mechanism underlying modulation of brain activity with this relatively new neuromodulation technique. However, some limitations of the technique should be addressed. First, the electrodes used in tDCS are usually rather large and the effects of stimulation are believed to cover a wide spatial extent of brain tissue. Coupled with the fact that MRS acquisition is limited to a small voxel of interest, tDCS-MRS only allows for the assessment of spatially circumscribed effects despite presumed widespread modulation of brain excitability. One possible way to circumvent this problem is to use multiple voxels of interest distributed throughout the brain. However, this will significantly increase duration of the experimental session, which is already a major limitation of the present technique. Indeed, when considering participant preparation, pre-tDCS MRS, tDCS intervention and post-tDCS MRS, a full session may easily last up to two hours. Duration can also increase if one wishes to map the time course of tDCS effects on metabolite concentration.
An important issue related to the duration of the experiment is the possibility that electrode impedance will increase after the participant is in the scanner. Since tDCS can easily begin more that 45 minutes after electrode placement, there is a risk that the stimulating electrodes will gradually lose adherence to the participant’s scalp if paste application is not optimal and electrodes are not held tightly enough. If impedance reaches more than 20 kΩ, stimulation will not be possible and the participant will need to be removed from the scanner to solve the problem. Since the described procedure involves multiple scanning of the same area pre- and post-tDCS, removing the participant from the scanner may create important displacement of the voxel of interest. It is therefore very important to test impedance immediately prior to scanning and to take great care when installing electrodes.
Theoretically, the current flow of the tDCS could produce artefacts in the MR signal. Antal and collaborators 80 investigated this specific concern by measuring the impact of different tDCS conditions (with and without electrodes, with and without stimulation, etc.) on the quality of functional magnetic resonance images. However, to our knowledge, the presence of artefacts in the spectroscopy signal due to the presence of the tDCS device in the scanner has yet to be assessed.
Finally, care should be taken with regards to the resistors in the electrode cables. The MR field may damage resistors, thus preventing stimulation. As a precautionary measure, resistance should be tested outside the scanner environment prior to every MRS session. In addition, an impedance of more than 20 kΩ can lead to skin reactions and high impedance may reflect an incipient or actual problem with the stimulator. Therefore, the stimulator should be checked carefully before every participant and impedance levels checked outside the scanner room prior to every MRS session.
Combined tDCS and 1H-MRS is a powerful tool that provides a quantitative measure of the effect of clinically used treatments on brain metabolism. As the physiological mechanism of tDCS effects remains poorly understood, there is a need for multimodal approaches that can shed light on these processes. With the recent surge in interest in tDCS as a clinical tool for pathologies such as stroke 27,30,31 and depression 81, it is clear that combination of tDCS with MRS may be an important tool to better understand the therapeutic effects of tDCS. Furthermore, tDCS-MRS may serve as an early tool to determine which patients have a better chance to respond clinically to tDCS. If such a marker is found, tDCS-MRS may be used as a screening test prior to enrolling patients in a tDCS intervention.
The authors have nothing to disclose.
This works was supported by grants from the Canadian Institutes of Health Research and the Natural Sciences and Engineering Research Council of Canada. ST was supported by a Vanier Canada Graduate scholarship from the Canadian Institutes of Health Research. MM acknowledges the support from Biotechnology Research Center (BTRC) grant P41 RR008079 and P41 EB015894 (NIBIB), and NCC P30 NS076408.
We would like to acknowledge Romain Valabrègue (Centre de NeuroImagerie de Recherche – CENIR, Paris, France) and Brice Tiret (Centre Recherche de l’Institut Universiatire de Gériatrie (CRIUGM), Montréal, Canada; Commissariat à l'énergie atomique et aux énergies alternatives (CEA), Paris, France) for developing processing tools, and Edward J. Auerbach (Center for Magnetic Resonance Research and Department of Radiology, University of Minnesota, USA). The MEGA-PRESS and FASTESTMAP sequences were developed by Edward J. Auerbach and Małgorzata Marjańska and were provided by the University of Minnesota under a C2P agreement.
DC-stimulator plus | NeuroConn | 30DCS01E | MR compatible device |
NuPrep preparation gel | Weaver and Co. | #10-61 | |
Ten20 conductive paste | Weaver and Co. | #10-20-4 | |
Electrode prepping pad | Grass technologies | MD0017 | 70% isopropyl alcohol and pumice |
Saline solution | Local drugstore sample | 0.9% sodium chloride | |
Non permanent hydro-marker | Sharpie | SHPE20WH | |
SYNGO MR VB17 | Siemens AG | MRI software | |
MAGNETOM Trio A Tim System | Siemens AG | MRI scanner version | |
Matlab 2013a (Version 8.1) | MathWorks Inc | processing and analysis software | |
LCModel 6.3 | LC MODEL inc | see: s-provencher.com | |
FASTESTMAP | Developers: Edward J. Auerbach and Małgorzata Marjańska | shimming sequence | |
MEGA-PRESS | Developers: Edward J. Auerbach and Małgorzata Marjańska | MRS sequence |