Source: Wabnitz, G. et al., Qualitative and Quantitative Analysis of the Immune Synapse in the Human System Using Imaging Flow Cytometry. J. Vis. Exp. (2019)
This video analyzes the immune synapse formation between T cells in unpurified pan-leukocyte preparations and Staphylococcus aureus enterotoxin B, SEB-loaded Raji cells. CD3 and F-actin enrichment is observed in the immune synapse using imaging flow cytometry.
All procedures involving sample collection have been performed in accordance with the institute's IRB guidelines.
1. Preparation of Pan-leukocytes
2. Loading of Raji Cells with SEB
3. Induction of Immune Synapses and Staining Protocol
4. Image Acquisition Using a Flow Cytometer
NOTE: The following image acquisition procedure and data analysis are based on imaging flow cytometry using software such as imagestream (IS100), INSPIRE, and IDEAS. However, other flow cytometers and analysis software can also be used.
The authors have nothing to disclose.
Multifuge 3 SR | Heraeus | ||
RPMI 1640 | LifeTechnologies | #11875085 | 500 mL |
FCS | Pan Biotech #3302-P101102 | ||
Polystyrene Round-Bottom Tube | Falcon | #352054 | 5 mL |
Dulbecco's Phosphate-Buffered Saline | Sigma | D8662 | |
Bovine Serum Albumin | Roth | #8076.3 | |
Saponin | Sigma | S7900 | |
Paraformaldehyde | Sigma Aldrich | #16005 | |
Speed Bead | Amnis | #400041 | |
Minishaker MS1 | IKA Works | MS1 | |
Microtiter plate | Greiner Bio One | #650101 | 96U |
Enterotoxin SEB | Sigma Aldrich | S4881 | |
DAPI | Sigma Aldrich | D9542 | One to three thousand ratio |
CD3-PeTxR | Invitrogen | MHCD0317 | One to thirty ratio |
Phalloidin-AF647 | Molecular Probes | A22287 | One to one fifty ratio |
IS100 | Amnis | Imaging flow cytometer | |
IDEAS | Amnis | Software | |
INSPIRE | Amnis | Software |