Journal
/
/
A Modified EPA Method 1623 that Uses Tangential Flow Hollow-fiber Ultrafiltration and Heat Dissociation Steps to Detect Waterborne Cryptosporidium and Giardia spp.
JoVE Journal
Immunologie und Infektion
This content is Free Access.
JoVE Journal Immunologie und Infektion
A Modified EPA Method 1623 that Uses Tangential Flow Hollow-fiber Ultrafiltration and Heat Dissociation Steps to Detect Waterborne Cryptosporidium and Giardia spp.

A Modified EPA Method 1623 that Uses Tangential Flow Hollow-fiber Ultrafiltration and Heat Dissociation Steps to Detect Waterborne Cryptosporidium and Giardia spp.

DOI:

12:11 min

July 09, 2012

, , , ,

Kapitel

  • 00:05Titel
  • 01:18Tangential Flow Hollow-fiber Ultrafiltration Procedure
  • 05:08Immunomagnetic Separation Procedure
  • 08:58Staining and Examination
  • 10:20Results: Visualization of Giardia cysts and Cryptosporidium oocysts
  • 11:40Conclusion

Summary

Automatische Übersetzung

This protocol describes the use of a tangential flow hollow-fiber ultrafiltration sample concentration system and a heat dissociation as alternative steps for the detection of waterborne Cryptosporidium and Giardia species using EPA Method 1623.