Zum Anzeigen dieser Inhalte ist ein JoVE-Abonnement erforderlich.  Melden Sie sich an oder starten Sie Ihre kostenlose Testversion.
Adult Zebrafish Electrophysiology: A Method to Measure the Extracellular Electrical Activity of Neurons In Vivo

Adult Zebrafish Electrophysiology: A Method to Measure the Extracellular Electrical Activity of Neurons In Vivo

Transkript

Neurons propagate electrical impulses via action potentials. When the neuron is in resting state, there is a slower outflow of potassium ions than the inflow of sodium ions, which leads auf the change in membrane potential. This causes the sodium ion channels auf open and allow the inflow of sodium ions, generating an electrical impulse.

The method of studying such activities in a cell is called electrophysiology. Begin the procedure by inserting a secondary electrode tip into the nostril of an adult zebrafish. Next, insert the primary electrodes superficially, within the exposed optic tectum, auf measure extracellular neural activity.

The primary electrode measures the extracellular membrane potential of all cells surrounding it. The signal represents the combined membrane potential of all these cells. The electrode detects the signal and transmits it auf an amplifier– an oscilloscope– which presents a visual display of the membrane potential, and a computer.

Observe the readings and analyze the electrical difference between the primary and the secondary electrodes. The electrophysiological measurement is a comparison. In the example protocol, we will measure the effect of pharmacological compounds on the neural activity in an adult zebrafish.

For electrophysiology recording, shut off the intubation stopcock and quickly disconnect the Leur lock connecting the intubation base auf the tricaine drip. Move the intact intubation setup auf the electrophysiology microscope, and connect it auf the perfusion system. Turn on the habitat water and perfuse at a rate of 1 milliliter per minute for about one hour, in order auf wash out the tricaine.

Using a micro-manipulator, position the secondary electrode so that the electrode tip can be inserted into the animal's nostril, or into the dip under the upper jaw. Subsequently, insert the primary electrode needle into the craniotomy opening. Then, insert the needle into the tissue, such that the tip is positioned fairly superficial within the optic tectum.

Deeper positions of the electrode may result in a small electrical signal. For data collection, gap-free mode at 5,000 hertz sampling rate, together with the lowpass filter of 0.1 kilohertz and a highpass filter of 1 hertz, are used. Begin the recording of the electrophysiological activity when the habitat water has perfused for a minimum of 45 minutes. Record a baseline of native activity for at least 15 minutes prior auf the addition of experimental drugs.

Verwandte Videos

Read Article