A hemolysis assay can be used as a rapid, high-throughput screen of drug delivery systems’ cytocompatibility and endosomolytic activity for intracellular cargo delivery. The assay measures the disruption of erythrocyte membranes as a function of environmental pH.
Phospholipid bilayers that constitute endo-lysosomal vesicles can pose a barrier to delivery of biologic drugs to intracellular targets. To overcome this barrier, a number of synthetic drug carriers have been engineered to actively disrupt the endosomal membrane and deliver cargo into the cytoplasm. Here, we describe the hemolysis assay, which can be used as rapid, high-throughput screen for the cytocompatibility and endosomolytic activity of intracellular drug delivery systems.
In the hemolysis assay, human red blood cells and test materials are co-incubated in buffers at defined pHs that mimic extracellular, early endosomal, and late endo-lysosomal environments. Following a centrifugation step to pellet intact red blood cells, the amount of hemoglobin released into the medium is spectrophotometrically measured (405 nm for best dynamic range). The percent red blood cell disruption is then quantified relative to positive control samples lysed with a detergent. In this model system the erythrocyte membrane serves as a surrogate for the lipid bilayer membrane that enclose endo-lysosomal vesicles. The desired result is negligible hemolysis at physiologic pH (7.4) and robust hemolysis in the endo-lysosomal pH range from approximately pH 5-6.8.
Although there are many potential high-impact therapeutic targets inside the cell, the intracellular delivery of agents poses a significant challenge. Frequently, drugs, especially biologics, are internalized by cells and trafficked into vesicles that either lead to degradation of their contents through the endo-lysosomal pathway, or are shuttled back out of the cell via exocytosis.1 In the latter process, the internal pH of the vesicles is acidified to approximately 5-6, which is the optimal pH for activity of enzymes that function in this compartment, such as lysozyme.2
Recently, a number of materials have been specifically engineered to leverage the acidification of endosomes to facilitate cytosolic delivery of their cargo. One example of this approach uses synthetic, polymer micelle nanoparticles whose core is zwitterionic and charge-neutral at physiologic pH (i.e. 7.4). However, at pH 6.0 – 6.5, the polymers become protonated and acquire a net positive charge that destabilizes the micelle core, and the exposed polymer segments interact with and disrupt the endosomal membrane. This activity has been shown to promote the endosomal escape of peptide and nucleic acid-based therapeutics, allowing them to access their cytosolic targets.3,4 Other examples of methods developed to mediate endosomal escape that disrupt the membrane barrier include ‘fusogenic’ peptides or proteins that can mediate membrane fusion or transient pore formation in the phospholipid bilayer.5 Homopolymers of anionic alkyl acrylic acids such as poly(propylacrylic acid) are another well-studied approach, and in these polymers, the protonation state of pendant carboxylic acid dictates transition into a hydrophobic, membrane-disruptive state in endo-lysosomal pH ranges.6,7
One useful model system for screening endosomolytic behavior is the ex vivo pH-dependent hemolysis assay.8 In this model system, the erythrocyte membrane serves as a surrogate for the lipid bilayer membrane that enclose endo-lysosomal vesicles. This generalizable model has been used by others to evaluate the endosomolytic behavior of cell-penetrating peptides and other polymeric gene delivery systems.8-11 In this experiment, human red blood cells and test materials are co-incubated in buffers at defined pHs that mimic extracellular (7.4), early endosomal (6.8), and late endo-lysosomal (< 6.8) environments. The amount of hemoglobin released during the incubation period is quantified as a measure of red blood cell lysis, which is normalized to the amount of hemoglobin released in positive control samples lysed with a detergent.
From screening a small library of potentially endosomolytic test materials, one can infer that samples that produce no hemolysis at pH 7.4, but significantly elevated hemolysis at pH < 6.5, will be the most effective and cytocompatible candidates for cytosolic drug delivery. Materials that fit these criteria would be expected to remain inert and not indiscriminately destroy lipid bilayer membranes (i.e. that could cause cytotoxicity) until being exposed to a drop in the local pH following internalization into endo-lysosomal compartments.
In this protocol, erythrocytes are isolated from a human donor and co-incubated at pH 5.6, 6.2, 6.8, or 7.4 with experimental endosomolytic drug delivery agents. Intact erythrocytes are pelleted, and the supernatants (containing hemoglobin released from lysed erythrocytes) are analyzed for the characteristic absorbance of hemoglobin via a plate reader (Figure 1).
1. Preparation and Sterilization of Buffers and Test Agents
2. Preparation of Erythrocytes
NOTE: All procedures must be pre-approved by the appropriate Institutional Review Board (IRB), and venipuncture and blood collection must be performed by a trained phlebotomist in order to minimize the risk to the donor. Standard phlebotomy procedures have been published elsewhere.13
3. Lysis Assay 96 Well Plate Setup and Quantification
NOTE: For ease, it is recommended that a separate 96-well plate should be prepared for each pH to be tested, with each sample (at each concentration) loaded at n=3-4 per plate.
NOTE: Different plate readers may have different saturation points and sensitivities, so the choice of a wavelength for measurements depends on whether or not hemolysis data from experimental samples can be reliably normalized against maximum hemolysis as induced by detergent treatment. This requires accurate measurement of absorbance values of the positive control samples.
Typically, the agents that exhibit ideal pH-dependent hemolytic behavior have the highest potential for cytosolic delivery of drugs, nucleic acids, or other bioactive molecules. This is exemplified by Agent #1 as portrayed in Figure 2, which exhibits minimal hemolysis at pH 7.4, but a sharp increase in hemolytic behavior at endosomal pH ranges (< 6.5). Some agents may exhibit significant levels of hemolytic behavior at physiological pH ranges (Agent #2 at 40 μg/ml; Figure 2), suggesting that these agents may not be hemocompatible and could potentially be cytotoxic at these concentrations.
In most cases, hemolysis is also dose-dependent, as increasing concentrations of the test materials correspond with higher levels of hemolysis, especially at the lower pH ranges tested (5.6 – 6.2).
Figure 1. Schematic Diagram of Red Blood Cell Hemolysis Assay. Human erythrocytes are isolated and incubated with experimental endosomolytic drug delivery agents in a series of buffers simulating the pH range from physiologic (7.4) to late endosomes/lysosomes (5.6). The optimal drug delivery agents will not disrupt the erythrocytes at physiologic pH but will exhibit robust hemolysis in more acidic conditions. To assess percent hemolysis, the release of hemoglobin into the surrounding medium is measured via absorbance on a plate reader.
Figure 2. Representative Results of a Hemolysis Assay Demonstrating Behavior of Two Experimental Endosomolytic Agents. First, the average A450 of the vehicle (PBS) control was subtracted from the other samples tested at that pH. Afterward, experimental samples were normalized to the A450 of Triton X-100-treated erythrocyte samples and multiplied by 100%. Based on these control samples, the ability of experimental transfection agents to lyse erythrocytes can be calculated. Typically, ideal endosomolytic agents exhibit dose-dependent and pH-dependent hemolytic behavior. Ideal agents (such as Agent #1) exhibit minimal hemolysis at pH 7.4, but a sharp increase in hemolytic behavior at endosomal pH ranges (< 6.5). Some agents exhibit substantial hemolytic behavior at physiological pH ranges (Agent #2 at 40 μg/ml), suggesting that these agents may be cytotoxic at these concentrations. Error bars indicate standard deviation of 4 independent measurements.
pH-responsive polymers or other agents designed for endosomolytic function can be rapidly and effectively screened based on lysis of red blood cells at pH values encountered in the endosome (Figure 1; pH 6.8 – early endosome, pH 6.2 – late endosome, pH 5.6 – lysosome).14-17 pH-dependent hemolysis has been used to screen the ability of carriers to mediate endosomal release of biomacromolecular therapeutics (e.g. peptides, siRNA, ODNs, proteins), and results of this assay can be predictive of performance as an intracellular drug delivery vehicle.3,4,8,18,19 Thus, this assay represents an effective screen to gauge the ability of polymeric drug carriers to mediate intracellular drug delivery based on their pH-dependent membrane disruption.
As noted in the procedure, hemolysis is detected through spectrophotometric measurement of the supernatants of red blood cells treated with experimental agents. Therefore, in addition to hemoglobin, it is likely to contain other erythrocyte-derived cytosolic components, including proteins and carbohydrates. While these other components may contribute a small amount of signal to the spectrophotometric measurement, 100% hemolysis was calibrated to the erythrocyte lysate resulting from treatment with Triton X-100. Assuming all erythrocytes from the same donor contain similar levels of hemoglobin and other biomolecules, we can safely conclude that the ‘contaminating’ components will not contribute any artifacts to the hemolysis measurement, especially if the same blood sample is used for all tests. However, this highlights the possibility that, for any given blood donor, there are likely to be small day-to-day variations in blood composition and hematocrit, and therefore, internal control samples (steps 3.3-3.4, 3.10-3.11) should be analyzed for all experiments.
One should also always closely examine the raw absorbance data. Though it cannot be appreciated in the normalized example data shown in Figure 2, detergents such as Triton X-100 effectively destabilize erythrocyte membranes regardless of pH, and one should expect to see very little sample to sample variability in positive controls. The absorbance spectrum of Triton X-100 does not include peaks in the 400-600 nm range recommended for this assay, and therefore, should not interfere with the normalization of experimental data.20 Furthermore, for negative control samples, one should not observe significant hemolysis after the 1 hr incubation in any of the buffers used (i.e. even the most acidic buffer does not typically generate hemolysis on this timeframe). Background readings on negative control samples should closely approximate background absorbance readings taken on the fresh buffers.
Ideally, researchers will employ complementary strategies to characterize their experimental drug delivery systems. The hemolysis assay is advantageous for initial endosomolytic agent screening on naturally-occurring biomembranes, but should be considered as only one of the many tools in the drug delivery researcher’s armamentarium for testing cytosolic delivery agents. For example, one potential shortcoming of the hemolysis assay is that it utilizes the red blood cell membrane as a biological model for endosomal membranes. However, the make-up and lipid content of endosomal membranes varies by cell-type and may not be accurately recapitulated by the blood cell membrane.1 A variety of other, complementary assays have been developed to mimic endosomal membrane composition and behavior.21,22 One alternative to is to utilize liposomes containing fluorescence resonance energy transfer (FRET)-quenched fluorophores, which become unquenched following destabilization of the liposomes and release of the fluorophores to the surrounding media. In studies that employ this method, the quantification of unquenched fluorophores has been found to correlate with the ability of a vehicle to mediate endosomal escape of its payload.21,23 Microscopy-based measurements can provide a more robust but lower-throughput method that is complementary to the hemolysis assay. For example, it is common to assess colocalization of the carrier or the drug itself with dye-labeled lysosomes (e.g. LysoTracker by Life Technologies), or the trafficking pathways can be characterized using pH-sensitive dyes conjugated the carrier or drug (e.g. pHrodo by Life Technologies).24-26
Once an endosomolytic delivery system has been confirmed to achieve cytosolic cargo delivery, the hemolysis assay can also provide information on the mechanism through which endosomal escape occurs. For example, gene delivery vehicles based on polyethyleneimine (PEI) lack an inherent ability to disrupt phospholipid membranes at neutral or acidic pH’s.11,27 Instead, PEI achieves cytosolic gene delivery through a ‘proton sponge’ effect. After internalization, PEI buffers the endosome by “absorbing” protons that are pumped across the endosomal membrane to acidify these compartments. Eventually, this leads to buildup of excess protons and their counter-ions inside the endosome. This results in a rise in osmotic pressure, water influx, vesicle swelling, and endosomolysis. Therefore, the success of proton sponge effect necessitates the accumulation of a critical concentration of PEI into an endosome.27 Delivery vehicles that achieve endosomal disruption through the ‘proton sponge’ effect will not physically disrupt red blood cells or liposomes, and their efficacy in achieving intracellular drug delivery must be assessed through osmotic pressure calculations, or in vitro microscopy, or functional studies.
In conclusion, the hemolysis assay described here is a reliable model for screening pharmaceutical agents designed for intracellular delivery of biologic drugs. This assay provides a high throughput means of drug delivery vehicle screening, enabling the rapid development of formulations that deliver biologics with intracellular targets.
The authors have nothing to disclose.
The authors acknowledge funding through the Department of Defense Congressionally Directed Medical Research Programs (#W81XWH-10-1-0445), National Institutes of Health (NIH R21 HL110056), and American Heart Association (#11SDG4890030).
Name of the reagent | Company | Catalogue number | Comments (optional) |
BD Vacutainer – K2EDTA Vacutainer Tubes | Fisher Scientific | 22-253-145 | For blood collection |
BD Vacutainer Blood Collection Needles, 20.5-gauge | Fisher Scientific | 02-665-31 | For blood collection |
BD Vacutainer Tube Holder / Needle Adapter | Fisher Scientific | 22-289-953 | For blood collection |
BD Brand Isopropyl Alcohol Swabs | Fisher Scientific | 13-680-63 | For blood collection |
BD Vacutainer Latex-Free Tourniquet | Fisher Scientific | 02-657-6 | For blood collection |
Hydrochloric acid (conc.) | Fisher Scientific | A144-500 | For adjustment of pH of D-PBS. |
Triton X-100 | Sigma-Aldrich | T8787 | Positive control |
Dulbecco’s PBS | Invitrogen | 14190 | |
Nalgene MF75 Sterile Disposable Bottle-Top Filter Unit with SFCA Membrane | Fisher Scientific | 09-740-44A | |
BD 96-well plates, flat-bottomed, tissue culture-treated polystyrene | Fisher Scientific | 08-772-2C | For plate-reading at the end of the assay. |
BD 96-well plates, round-bottomed, tissue culture-treated polystyrene | Fisher Scientific | 08-772-17 | For incubation of red blood cells with experimental agents. |