An Imaging Technique to Study the Calcium Response in Bacteria-Infected Cells

Published: October 31, 2023

Abstract

Source: Smail, Y., et al. Imaging Ca2+ Responses During Shigella Infection of Epithelial Cells. J. Vis. Exp. (2018).

This video demonstrates a technique for detecting local and global calcium ion response upon Shigella infection of human epithelial cells. Shigella invades host cells and releases invasion effectors, impacting intracellular calcium levels. The amplitude and frequency of the local and global cytosolic calcium are studied using a fluorescent indicator.

Protocol

1. Preparations

  1. Bacteria preparation
    1. Plate the bacteria—Shigella wild-type strain expressing the AfaE adhesin (M90T-AfaE)—onto a trypticase soy (TCS) agar plate containing 0.01% Congo red (CR) and incubate them for 18 h at 37 °C.
      Note: To increase their reproducibility, the Shigella plates obtained in step 1.1.1 are stored at 4 °C and should be used within a week because all colonies on CR medium will eventually turn red over time.
    2. Inoculate TCS broth pre-culture by picking 3 red colonies from the streak plates.
      Note: An inoculation with 3 colonies is performed to limit the probability of picking a single clone whose virulence plasmid has undergone a genetic recombination.
    3. Grow liquid bacterial cultures in a shaking incubator for 16 h at 37 °C at 200 rpm. Add ampicillin at a final concentration of 75 mg/mL. Antibiotic concentrations should not exceed 3x the minimal inhibitory concentration, as an excess of antibiotic may lead to the loss of the large virulence plasmid.
      Note: The maintenance of the Shigella virulence plasmid should be verified by plating the bacterial cultures on CR plates supplemented with appropriate antibiotic concentrations. The presence of white colonies indicates plasmid loss.
    4. Inoculate the TCS culture with the bacterial pre-culture at a 1:100 dilution. Incubate it at 37 °C in a shaking incubator for 2 h at 200 rpm. Ensure that the optical density at 600 nm (OD600nm) is 0.2 – 0.4.
    5. Centrifuge the bacterial culture for 2 min at 13,000 x g at 21 °C and resuspend the pellet in an equivalent volume of EM medium (120 mM NaCl, 7 mM KCl, 1.8 mM CaCl2, 0.8 mM MgCl2, 5 mM glucose, and 25 mM HEPES, pH = 7.3).
    6. Dilute the bacterial suspension in an EM buffer at a final OD600nm of 0.1 and use it immediately or store it at 21 °C and use it within the next 60 min.
  2. Cell preparation
    1. Culture HeLa cells in DMEM with 1 g/L of glucose supplemented with 10% fetal calf serum (FCS) and grow them at 37 °C with 10% CO2. Grow TC-7 grown in DMEM with 4.5 g/L of glucose, containing 10% FCS and non-essential amino acids in a 37 °C incubator containing 10% CO2.
    2. For cell maintenance, split the cells regularly to avoid a growth-contact inhibition linked to confluent states; this is critical for a high Ca2+ probe loading/transfection efficiency.
    3. Plate HeLa cells onto sterile 25-mm diameter circular coverslips in 6-well plates at a density of 3 x 105 cells/well the day before the experiment for the HeLa cells.
    4. For TC-7 cells, trypsinize and count cells. Seed them at 4 x 105 cells/well and incubate them for 5 – 7 days at 37 °C in a 10% CO2 incubator before the experiments to allow for polarization.
      1. Refresh the cell culture medium every day until the day of the experiment.
        Note: Glass-bottom 35-mm diameter disposable chambers may also be used as an alternative to the coverslips-containing wells. If the latter are used, temperature control through a heated stage or objective is not sufficient, and a thermostat incubation chamber mounted on the microscope stage is required.
  3. On the day of the experiment, remove the medium and wash the cells 3x with 1 mL EM medium at 21 °C.
  4. Load the cells with 3 mM Fluo-4/acetoxymethyl ester (Fluo-4-AM) in an EM buffer for 30 min at 21 °C.
    Note: While the loading of sub-confluent HeLa cells does not raise major problems, the loading of polarized TC-7 cells is often heterogeneous and poorly efficient. For these cells, we found that the loading efficiency is enhanced by the addition of the dispersing agent—pluronic acid—at a final concentration of 0.1% and of the anion-transporter inhibitor bromosulfophtalein at a final concentration of 20 µM to the Fluo-4-AM-containing EM. The use of ratiometric chemical probes or genetically encoded FRET probes requiring dual acquisition is not compatible with the speed of acquisition required for the imaging of local Ca2+ responses.
  5. Wash the samples 3x with EM buffer and further incubate them in 1 mL of EM buffer at 21 °C to allow for the hydrolysis of the AM moiety. Use Fluo-4 loaded cells immediately or within the next 90 minutes (maintained at 21 °C).

2. Infection and Image Acquisition of Local Ca2+ Responses

  1. Place the coverslip containing the Fluo-4 loaded cells in an imaging chamber or glass-bottom chamber. Wash the samples in the imaging chamber or glass-bottom disposable chamber 3x with EM buffer to remove compounds potentially resulting from cell lysis. Add 1 mL of EM buffer.
  2. Place the chamber on an inverted fluorescence microscope stage heated at 33 °C.
    Note: This temperature is selected as a compromise between the optimal temperatures compatible with the Shigella invasion process and the slowing down of Ca2+ responses to visualize local responses. We use a 63X immersion oil objective (NA = 1.25) equipped with phase contrast rings.
  3. Select a microscopy field and set up acquisition parameters, including exposure time and binning if necessary, to optimize the Fluo-4 fluorescent signal.
    Note: The major challenges of local Ca2+ imaging are the low amplitude and the small duration of the responses, requiring acquisition at least every 30 ms. Several commercially available back-illuminated electron-multiplying charge-coupled devices (EM-CCD) or complementary metal-oxide semiconductor (C-MOS) cameras present the required sensitivity to detect local Ca2+ responses using Fluo-4. Detection sensitivity is also an important issue in limiting photodamage or artifacts such as spontaneous responses linked to the fluorescent excitation of Fluo-4 at a high frequency. Here, an LED-based illumination of 470 nm, with a 480 ± 40 nm band-pass excitation filter, a 505-nm dichroic filter, and a 527 ± 30 nm band-pass emission used at 5% of its maximal intensity combined with a 1.0 neutral density filter were used to minimize these problems under a stream of acquisitions of limited durations. An analysis of local Ca2+ signals by batches of 120 s streams was routinely performed. Under these low illumination conditions, fluorophore photobleaching was not observed during the 2 min-stream acquisitions. Successive acquisitions on the same sample can be performed, provided different fields are used. As a general rule, a first acquisition stream is performed on a control field in the absence of bacteria stimulation to ensure the absence of spontaneous responses. If spontaneous responses are observed, the samples are washed with EM buffer until no responses are observed.
  4. To add bacteria to the sample, remove 500 µL of EM buffer from the chamber and add 500 µL of the bacterial suspension prepared in step 1.1.6 to obtain a final OD600nm of 0.05, with the appropriate care to avoid moving the selected microscopy field; the volumes ensure a proper mixing of the bacteria and a homogeneous distribution of the bacteria onto the cell samples.
  5. Perform an acquisition upon the bacterial addition. Alternatively, perform an acquisition 10 min following the bacterial addition, which corresponds to the time required for bacteria to sediment onto cells under the conditions used. At the end of the acquisition stream, acquire a phase-contrast image of the selected field to visualize the bacteria contacting the cells and the membrane ruffles associated with bacterial invasion sites.
  6. Repeat the acquisition procedure as in step 2.5, at intervals that are amenable to the duration of the image acquisitions, file savings, and selection of a new field to cover the whole process.
    Note: For Shigella, we found that acquisition streams every 5 min for 20 min, following the 10 min bacterial sedimentation, allowed to cover the majority of the invasion events.
  7. At the end of the acquisition procedure, add a final concentration of 2 µM of the Ca2+ ionophore ionomycin samples to determine the maximal amplitude of the Ca2+ signals. Acquire images every 3 – 5 s until signal stabilization, usually for less than 10 min.
  8. Follow by adding Ca2+ chelator ethylene glycol-bis(β-aminoethyl ether)-N, N, N′, N′-tetraacetic acid (EGTA) at a final concentration of 10 mM to determine the fluorescence signal in the absence of Ca2+. Acquire images every 3 – 5 s until signal stabilization, usually for less than 10 min.
    Note: Because of the relatively slow dynamics of the global Ca2+ variations, perform these acquisitions every 3 – 5 s (not in streaming mode), allowing for Ca2+ imaging on the same microscopic field during the successive treatments.

3. Analysis

  1. Express cytosolic Ca2+ variations over time as the percentage of ΔF/F0, where ΔF represents the variation of the average fluorescence intensity of the region of interest (ROI) and F0 the baseline fluorescence in the same ROI, to which a non-relevant region of the field devoid of cells is subtracted.
    1. Remove the basal fluorescence levels for each cell in different fields, corresponding to baseline levels; these levels can be unambiguously determined due to the low frequency and relatively short duration of local Ca2+ responses in a given stream acquisition.
      ​Note: Quantify striking features of the responses related to the questions asked and the pathogenic model studied. Classically, various parameters are taken into account to analyze Ca2+ signals, including the frequency of cells showing local or global Ca2+ responses, as well as the duration, amplitude, and frequency of these responses. In the case of Shigella and local responses, another important aspect of the analysis is the spatial association of the responses with bacterial invasion sites.
  2. To quantify the percentage of responsive cells showing global or local responses, draw ROIs in cells, in time series corresponding to the variations of Fluo-4 intensity.
    1. Set strict parameters to identify local Ca2+ responses, such as an amplitude of three-fold above background variations of the average fluorescence intensity cell baseline, or a duration of at least 200 ms, to avoid scoring a false positive.
      Note: As a general rule, even small local Ca2+ responses can be distinguished from any background noise by their profile. The ROIs should be large enough to integrate enough fluorescence signals to allow for the detection of local variations. Depending on the intensity of the Fluo-4 detection, these ROIs may correspond to circles with diameters ranging from 2 – 5 mM.
    2. Measure the variations of the average Fluo-4 fluorescence intensity in 2 regions in a distinct area of the same cell, to determine whether the responses are local or global.
      Note: The analysis of a large number of cells is facilitated by the use of imaging software permitting the online screen display of the variations of the average fluorescence intensity over time for the selected regions. Commercially available imaging software has such an option, but this can also be performed using the Icy freeware, using the ROI Intensity Evolution plugin.
    3. Determine the percentage of cells showing local responses.
      Note: This percentage is calculated from the total number of cells analyzed in the microscopy field, which should be in sufficient numbers to support a statistical significance using a non-parametric test.
    4. Determine the duration of the local responses.
      Note: Local Ca2+ responses can be further distinguished according to their duration ranges (i.e., less than 500 ms, between 5 and 10 s, or above 10 s) and their association with Shigella invasion sites.
  3. Quantify the amplitude of the responses. First, calibrate the maximal Ca2+ and cell background levels determined in step 2.1.7. Since the Fluo-4 load may vary for each cell, perform these determinations for individual cells in the field.
    1. Express the amplitude of the responses as a relative percentage of the maximal response.
    2. Perform statistical testing using a normality test, followed by a parametric test to analyze potential differences in the amplitude of responses between samples.
    3. Determine the association of these responses relative to the bacterial invasion sites by their respective localization to the bacterial-induced membrane ruffles visualized in the corresponding phase contrast images.

Offenlegungen

The authors have nothing to disclose.

Materials

Fluo-4 AM Invitrogen F14201
Metamorph version 7.7 Universal Imaging
CoolLED illumination system pE-2 Roper Scientific
Micro-dish 35 mm, high IBIDI 81156
Trypticase Soy (TCS) broth Thermofisher B11768
TCS agar Thermofisher B11043
Congo red Sigma-Aldrich 75768
M90T-AfaE Sun et al. 2017 Shigella flexneri serotype V. expressing the AfaE adhesin
ipgD-AfaE Sun et al. 2017 Isogenic ipgD mutant strain expressing the AfaE adhesin

Tags

Play Video

Diesen Artikel zitieren
An Imaging Technique to Study the Calcium Response in Bacteria-Infected Cells. J. Vis. Exp. (Pending Publication), e21664, doi: (2023).

View Video