Source: Sionov, R. V., et al., Isolation and Characterization of Neutrophils with Anti-Tumor Properties. J. Vis. Exp. (2015)
In this video, we demonstrate the isolation of cytotoxic high-density neutrophils and low-density neutrophils from the blood of a tumor-bearing mouse by discontinuous sucrose gradient centrifugation.
All procedures involving animal models have been reviewed by the local institutional animal care committee and the JoVE veterinary review board.
1. Neutrophil Isolation
Figure 1. Neutrophil purification from whole blood. (A) 3 ml of 1.077 g/ml sucrose is carefully layered on top of 3 ml 1.119 g/ml sucrose to form a discontinuous gradient. Whole murine blood, diluted in PBS-BSA (0.5%) to a final volume of 6 ml, is then layered on top of the 1.077 g/ml sucrose. (B) Following a 30 min spin at 700 x g with no break, 3 distinct fractions can be observed; R – red blood cells in the pellet, G – the granulocytic fraction containing high-density neutrophils, M – mononuclear fraction containing mononuclear cells and low-density neutrophils. (C) Freshly drawn human blood is mixed with an equal volume of Dextran 500 (3%) and incubated at RT for 30 min. The top fraction containing the white blood cells (buffy coat) is then layered on top of 10 ml 1.077 g/ml sucrose. (D) Following a 30 min spin at 400 x g with no break, 2 distinct fractions may be observed; R+G – pellet containing red blood cells and high-density neutrophils, M – mononuclear fraction containing mononuclear cells and low-density neutrophils.
The authors have nothing to disclose.
Mouse 4T1 breast carcinoma cells | ADCC | CRL-2539 | Growth medium: DMEM + 10 % heat-inactivated FBS |
24-well Tissue Culture Plate | Falcon | 353047 | |
100 mm Tissue Culture Plate | Corning | 430167 | |
25 cm2 Tissue Culture Flask | Nunc | 156340 | |
90 mm Bacterial Grade Culture Dish | Miniplast, Ein Shemer, Israel | 20090-01-017 | |
15 ml Sterile Conical Centrifuge Tube | Miniplast, Ein Shemer, Israel | 835015-40-111 | |
50 ml Sterile Conical Centrifuge Tube | 835050-21-111 | ||
Falcon 12×75 mm Round-Bottom Polystyrene Tube | Becton Dickinson | 352058 | |
HPLC grade water | J.T. Baker | 4218-03 | Autoclave |
Histopaque-1119 | Sigma | 11191 | Sterile filter through a 0.2 mm filter. |
Histopaque-1077 | Sigma | 10771 | Sterile filter through a 0.2 mm filter. |
PBS+0.5% BSA | Dissolve 2.5g BSA in 500 ml PBS, and sterile filter through a 0.2 mm filter. | ||
PBS+1% BSA | Dissolve 1g BSA in 100 ml PBS, and sterile filter through a 0.2 mm filter. | ||
Bovine serum albumin (BSA), fraction V | Sigma | A7906 |