Back to chapter

2.18:

Titrimetric Methods: Types and Commonly Used Strategies

JoVE Core
Analytical Chemistry
Zum Anzeigen dieser Inhalte ist ein JoVE-Abonnement erforderlich.  Melden Sie sich an oder starten Sie Ihre kostenlose Testversion.
JoVE Core Analytical Chemistry
Titrimetric Methods: Types and Commonly Used Strategies

Sprachen

Teilen

Titrimetric methods are quantitative procedures used in analytical chemistry.

For example, volumetric titrations involve measuring the volume of a titrant of known concentration required to react completely with an analyte.

Whereas in gravimetric titrations, an analyte reacts with a titrant to yield a precipitate that is isolated and weighed.

Alternatively, coulometric titrations involve measuring the charge required to complete an electrochemical reaction.

Strategies for titration include direct titration, where a titrant reacts with an analyte until it reaches the endpoint.

Other strategies are used if the reaction is slow or there is no direct titration reaction.

Back titration involves determining the excess of a standard solution used to consume an analyte by titrating with a second standard solution.

If the analyte displaces a group from a complex, the amount of the displaced group is determined using displacement titration.

2.18:

Titrimetric Methods: Types and Commonly Used Strategies

In chemistry, titrimetric methods are broadly classified into three types: volumetric, gravimetric, and coulometric. Volumetric titrations involve measuring the volume of a titrant of known concentration that is required to react completely with an analyte. In gravimetric titrations, the standard solution reacts with the analyte to form an insoluble precipitate, which is filtered, dried, and weighed. In coulometric titrations, current is applied to an electrochemical reaction until the reaction is complete, and the charge required for this reaction is calculated to determine the amount or concentration of the reactant(s).

Generally, in titrations, a titrant with a known concentration is added to the analyte until the analyte is consumed, i.e. when the endpoint is reached. In this case, the process is called direct titration. In some cases, the reaction may be too slow for a sharp endpoint to be obtained. In such cases, back titration is used. In a back titration, the analyte is allowed to react with an excess amount of a standard solution, and the remaining quantity of this standard solution is titrated with a second standard solution. The exact amount of the first standard solution required to react with the analyte can then be calculated.

Sometimes, no suitable indicator can be found for either a direct or an indirect (back) titration. In this case, displacement titration can be used, in which the analyte displaces a reagent, usually from a complex, and the displaced reagent is measured by titration.