Bioluminescent bacteria regulate light production through a variety of mechanisms, such as quorum sensing. This novel method allows the in situ investigation of bioluminescence and the correlation of light emission to cell density. An artificial bioluminescent Escherichia coli system allows the characterization of lux operons, Lux proteins, and their interplay.
There is a considerable number of bacterial species capable of emitting light. All of them share the same gene cluster, namely the lux operon. Despite this similarity, these bacteria show extreme variations in characteristics like growth behavior, intensity of light emission or regulation of bioluminescence. The method presented here is a newly developed assay that combines recording of cell growth and bioluminescent light emission intensity over time utilizing a plate reader. The resulting growth and light emission characteristics can be linked to important features of the respective bacterial strain, such as quorum sensing regulation. The cultivation of a range of bioluminescent bacteria requires a specific medium (e.g., artificial sea water medium) and defined temperatures. The easy to handle, non-bioluminescent standard-research bacterium Escherichia coli (E. coli), on the other hand, can be cultivated inexpensively in high quantities in laboratory scale. Exploiting E. coli by introducing a plasmid containing the whole lux operon can simplify experimental conditions and additionally opens up many possibilities for future applications. The expression of all lux genes utilizing an E. coli expression strain was achieved by construction of an expression plasmid via Gibson cloning and insertion of four fragments containing seven lux genes and three rib genes of the lux-rib operon into a pET28a vector. E. coli based lux gene expression can be induced and controlled via Isopropyl-β-D-thiogalactopyranosid (IPTG) addition resulting in bioluminescent E. coli cells. The advantages of this system are to avoid quorum sensing regulation restrictions and complex medium compositions along with non-standard growth conditions, such as defined temperatures. This system enables analysis of lux genes and their interplay, by the exclusion of the respective gene from the lux operon, or even addition of novel genes, exchanging the luxAB genes from one bacterial strain by another, or analyzing protein complexes, such as luxCDE.
The emission of light by living organisms (bioluminescence) is a fascinating process found in bacteria, fungi, insects, nematodes, fish, and squids1. Bioluminescent light emission emerges from a chemiluminescent reaction in which chemical energy is (partially) transformed into light energy ("cold light"). In bioluminescent bacteria, the heterodimeric enzyme luciferase catalyzes the monooxygenation of long chain, aliphatic aldehydes, such as tetradecanal, to the corresponding acids accompanied by light emission with a maximum at 490 nm2,3.
Figure 1: General reaction scheme of bacterial luciferase. The bacterial luciferase (LuxAB) catalyzes the monooxygenation of long chain aldehydes (CH3(CH2)nCHO) by utilizing reduced flavin mononucleotide (FMNH2) and molecular oxygen (O2), yielding the products long chain acids (CH3(CH2)nCOOH), flavin mononucleotide (FMN), water (H2O), and the emission of light centered at 490 nm. Please click here to view a larger version of this figure.
The energy released during this oxidation causes an excited state FMN-4a-hydroxide, which serves as the light emitting luciferin4. The proteins involved in bacterial bioluminescence, namely LuxCDABEG, are encoded by the lux operon and are highly conserved over various bacterial strains2,5. The genes luxA and luxB encode for the heterodimeric luciferase; luxC's, luxD's, and luxE's gene products are components of a fatty acid reductase complex; and luxG encodes for a flavin reductase6. A number of bioluminescent Photobacteria (e.g.,Photobacterium mandapamensis 27561) carry the additional luxF gene. It was reported that LuxF is a homodimeric protein that binds the unusual flavin derivative 6-(3'-(R)-myristyl)-FMN (myrFMN)7,8,9,10,11,12. Additional genes have been identified that are responsible for riboflavin synthesis (e.g., ribEBH) and furthermore regulatory genes have been reported, that play a role in quorum sensing regulation of bioluminescence, especially for Vibrio fischeri and Vibrio harveyi6,13. Despite the highly conserved gene order, bioluminescent bacteria show high variations in characteristics like growth behavior, intensity of light emission, or regulation of bioluminescence2,5,14.
Several modified strains or plasmids containing parts or whole lux operons are known, exploiting bioluminescence as reporter systems. Various applications such as determining promoter activity, monitoring of bacterial contaminations in environment or food samples, Bioluminescence Resonance Energy Transfer (BRET), in vivo imaging of infections in eukaryotic organisms, pyrosequencing, and so forth were established15,16,17. Interestingly, the three most frequently used bioluminescent reporter systems are derived from the North American firefly (Photinus pyralis), the enteric pathogen of nematodes (Photorhabdus luminescens), and the sea pansy (Renilla reniformis). None of those systems has a bacterial origin, but the use of lux genes and operons from bacterial origins is gaining more interest for applied research16. The less abundant application of bioluminescence proteins from bacterial sources is mainly due to lower stability and longevity of bacteria derived luminescent proteins which can be related to their marine habitats. Bioluminescent bacteria of marine habitats are not cultivable under standard lab conditions. These bacteria require specific growth media and conditions, such as artificial sea water medium and lower growth/incubation temperatures (e.g., 28 °C).
To simplify comparison of lux operon characteristics or single lux genes of a range of different bioluminescent bacterial strains, a method to standardize lux operon expression and analysis is a prerequisite. Thus, the idea of integrating the whole lux-rib operon into the standard-research bacterium Escherichia coli (E. coli) emerged. For this purpose, Gibson assembly proved to be a useful tool to integrate multiple linear, overlapping fragments into one expression vector without the need for specific restriction sites. This method is also suitable when DNA inserts are too large (e.g.,P. mandapamensis 27561 luxCDABFEG-ribEBH; ~ 9 kb operon size) to be amplified via PCR. A lux operon can be separated into multiple overlapping fragments, then be assembled into one expression plasmid and finally the sequence verified assembly product can be directly transformed into an appropriate E. coli system for high yield protein expression18,19,20. In addition to the easy to handle E. coli based lux gene expression, a simple method combining recording of cell growth and bioluminescent light emission remained to be established. The method described here allows the in situ measurement and correlation of cell density and light emission of bioluminescent bacteria.
The analysis of lux genes and lux operon order and regulation of various bioluminescent bacteria with, on the one hand, an artificial bioluminescent E. coli system containing the whole lux-rib operon of P. mandapamensis 27561 and, on the other hand, a newly developed plate reader assay combining the in situ recording of cell density and light emission, helps to gain more information on the various bacterial lux systems. This fundamental characterization and comparison of luciferases and related enzymes may lead to alternatives to the already established reporter systems with enhanced stability and activity.
1. Design, Preparation, and Expression of the lux Operon in Escherichia coli
Note: See Table of Materials for information on commercial kits used in this section.
2. Expression of Modified E. coli Strains
3. Expression of Bacterial Bioluminescent Strains
NOTE: Bacterial bioluminescent strains require specific growth medium/artificial sea water medium for growth and light production.
4. In Vivo Activity Assay for Bacterial Bioluminescent Strains and Modified E. coli Strains
NOTE: Long time storage of strains is normally acieved through freezing glycerol stocks of the bacterial culture. Strains should always be streaked on agar plates first to assure uniform starting conditions for all strains, prior to usage for liquid cultures, due to a lag phase in growth after thawing.
The gene order of the lux operon - luxCDABFEG – is highly conserved over various strains2,5,14. For the design of the plasmid, the sequence information was taken from the bioluminescent bacterial strain Photobacterium mandapamensis 27561 and its gene order was kept the same, and, also, noncoding sequences between single genes were considered. A schematic overview of the applied Gibson cloning strategy is depicted in Figure 2. Four fragments in total, luxCDAB, luxF, luxEG, and ribEBH, with 20 – 40 base pair overlapping sequences were generated. After following all steps of the Gibson assembly20, DNA sequencing confirmed the correct assembly of the plasmid, including all fragments. The vector map of the final assembly product pET28a containing the lux-rib operon is depicted in Figure 3. A significant advantage of this modified pET28a vector is the utilization of standardized E. coli growth conditions and controlled induction with IPTG.
To measure light emission of bioluminescent bacteria and the respective cell density, a plate reader based method was developed. The method for the plate reader was generated combining single measurement scripts for light intensity and cell density. This novel script enabled the measurement of OD650 and light intensity every 10 min for a user defined time frame, which has to be adjusted to the generation time of the bacteria used for the respective analysis (e.g., 10 h). The measurement of the optical density was performed at 650 nm to avoid interference with the light emission. As a proof of concept and to assure the health and the correct growth behavior of the E. coli cells, reference measurements were performed. In Figure 4 the comparison of E. coli BL21 cells, E. coli BL21 cells containing an empty pET28a vector, and E. coli BL21 cells containing the pET28a vector with the lux-rib operon insert are presented. For the latter strain, no IPTG was added to analyze the light emission due to the leakiness of the T7 promoter. All three reference measurements show a sigmoidal growth curve with three growth phases (lag, exponential, and stationary phase). Only the E. coli BL21 cells containing the pET28a vector with the lux-rib operon insert start to emit light, but in contrast to the measurements where expression is induced by addition of IPTG and light is emitted after 30 min, the non-induced cells only start to shine after approximately 5 h and show a much lower light emission (ca. 4-fold) compared to the induced system.
Figure 5 gives a comparison of growth curves and light intensities of the lux operon expressed in E. coli and the bioluminescent bacterial strain P. mandapamensis 27561, either in LB medium or in artificial sea water medium, using the novel established in situ method. To compare these bacteria, the measurements were performed at an incubation temperature of 28 °C. This temperature decreases the growth rate of the modified E. coli strain in LB medium as well as artificial sea water medium, but for bioluminescent bacterial strains lower temperatures are crucial. This temperature dependence is visible in Figure 5A, as P. mandapamensis 27561 shows a much higher cell density than E. coli. Furthermore, while for E. coli strains, LB medium allows generation of higher cell densities, for natural bioluminescent bacterial strains, artificial sea water medium is preferred and essential for bioluminescence. The recorded cell densities correlate with the respective light intensities, as shown in Figure 5B. Noteworthy, the bioluminescent E. coli cells reach similar light emission maxima in both LB medium as well as artificial sea water medium, although the highest intensities were recorded at different time points. In contrast to this observation, P. mandapamensis 27561 is viable with highly reduced growth rates in LB medium, but the bacterial cells did not emit light at all (Figure 5B). In artificial sea water medium, P. mandapamensis 27561 shows a maximum of light emission at around 1 x 104 counts per second, which is nearly a factor of 200 lower than E. coli. Figure 5C represents relative light units where the bioluminescence is normalized by the OD. These results confirm that not only was the insertion of a plasmid containing the lux operon into E. coli successful and functional, but also that this modified E. coli strain is a valid alternative with even higher light emission yields and without the limitation of bacterial bioluminescence of marina bacteria, such as a complex seawater medium and lower temperatures.
Additionally, a long-term measurement of the E. coli based lux-rib gene expression over 24 h was performed to analyze the longevity of the light emission (Figure 6). Light emission lasted for 19.5 h, much longer than the bacterial strains (e.g., P. mandapamensis 27561) where a gradual decrease was observed resulting in very low light emission after 10 h.
To illustrate the limitations of the developed assay, Figure 7 shows the measurement results of three bioluminescent bacterial strains, namely Photobacterium mandapamensis S1, Photobacterium mandapamensis TH1 and Vibrio harveyi 14126. For the first strain (S1), the method works very well and shows a maximal bioluminescence intensity of nearly 2 x 106. For the other two strains (TH1 and 14126), the maximal light intensity cannot be determined because the light intensity generated by both exceeded the detection limit of the used instrument settings. The gain value defined for the developed method (script) for these two strains was set too high. Nevertheless, the onset of bioluminescence activity can be compared with each other. P. mandapamensis TH1 and P. mandapamensis S1 start shining after approximately 1 h and an OD650 value of 0.1 – 0.2, respectively. In contrast, V. harveyi 14126 starts to emit light after approximately 5.5 h at an OD650 value of 1.0. The observed onset of light emission is accompanied by an exponential increase in OD as well as bioluminescence. It is known that bioluminescence of V. harveyi 14126 underlies quorum sensing regulation and therefore a specific cell density allowing the activation of the lux operon, which can be clearly observed in Figure 713. This result demonstrates that with this novel in situ plate reader assay it is possible to easily compare bioluminescent bacteria and also roughly define a regulatory mechanism of these strains by determining whether a quorum sensing regulation can be observed or not.
Figure 8 shows an example of an expression culture of E. coli BL21 cells harboring the assembled pET28a plasmid containing the lux operon after induction with IPTG. After approximately one h after induction, the E. coli cells start shining with a blue-green color. Figure 8A shows the E. coli expression culture photographed in the light and Figure 8B gives the same culture in the dark. Figure 8C depicts an agar plate of artificial sea water medium with P. mandapamensis S1 glowing in the dark in the same blue-green color characteristic for bacterial bioluminescence.
Figure 2: Schematic representation of the applied Gibson cloning strategy. Step (I): Overlapping primers (colored arrows; ca. 20 – 40 base pair overlap) are designed. Overlapping primers contain annealing sequences consisting of the respective 5' and 3' region of one fragment and the respective 3' and 5' region of the adjacent segment. Step (II): The designed fragments for assembly are generated via standard PCR reactions. Step (III): The target vector is linearized by restriction digestion (e.g., NcoI, XhoI). Step (IV): The DNA concentrations of all fragments and the linearized vector have to be determined to adjust concentration appropriate for Gibson assembly (according to the manufacturer's protocol). Step (V): All fragments and the linearized vector with optimized DNA concentrations are combined with the Gibson assembly master mix (T5 exonuclease, DNA polymerase, and DNA ligase) and are incubated at 50 °C for 1 h. Step (VI): The assembly product is transformed according to standard protocols into an appropriate E. coli strain for high yield plasmid replication (e.g., E. coli TOP10 or XL-1). Step (VII): To verify the correct assembly of the plasmid, DNA sequencing of the assembled plasmid has to be performed. Please click here to view a larger version of this figure.
Figure 3: Vector map of pET28a containing the lux-rib operon. The lux-rib operon of P. mandapamensis 27561 is inserted in the multiple cloning site of pET28a in the original gene order (luxCDABFEG-ribEBH). Restriction sites used for cloning are NcoI and XhoI. Fragments used for Gibson assembly of the operon are luxCDAB in orange, luxF in green, luxEG in blue and ribEBH in lavender; genes within a fragment are shown as a separate box. Noncoding sequences between each gene of the operon are included in the applied cloning strategy. The final plasmid size of pET28a containing the whole lux-rib operon is 14,625 base pairs. Please click here to view a larger version of this figure.
Figure 4: Comparison of growth curves and light intensities of reference strains. The OD at 650 nm and the bioluminescence intensity in counts per second were measured every 10 min over 10 h at 28 °C. All measurements are mean values of three biological replicates with four technical replicates each. Error bars represent standard deviations. E. coli BL21 cells (grey squares), E. coli BL21 cells containing an empty pET28a vector (grey circles), and E. coli BL21 cells containing the pET28a vector with the lux-rib operon insert (black diamond) were analyzed to assure correct growth behavior of our E. coli cells. Please click here to view a larger version of this figure.
Figure 5: Comparison of growth curves and light intensities of the lux operon expressed in E. coli (squares) and P. mandapamensis 27561 (circles) in LB medium (open symbols) or artificial sea water medium (filled symbols). All measurements are mean values of three biological replicates with four technical replicates each. Error bars represent standard deviations. All experiments were performed at an incubation temperature of 28 °C. (A) Optical density (OD) measurements at 650 nm were performed every 10 min for 10 h. E. coli lux operon expression (left panel) is compared to P. mandapamensis 27561 (right panel) in LB medium and artificial sea water medium. Cell densities are determined at 650 nm to avoid bioluminescence-interference. (B) Measurement of light intensity (bioluminescence [counts/s]) was performed every 10 min for 10 h. E. coli lux operon expression (left panel) is compared to P. mandapamensis 27561 (right panel) in LB medium and artificial sea water medium. (C) Relative light intensities (RLU/OD) of the lux operon expressed in E. coli (left panel) and P. mandapamensis 27561 (right panel) are determined by normalizing bioluminescence to cell density. Please click here to view a larger version of this figure.
Figure 6: Comparison of growth curves and light intensities of E. coli based lux gene expression for 24 h. The OD at 650 nm and the bioluminescence intensity in counts per second were measured every 10 min over 24 h at 28 °C. All measurements are mean values of three biological replicates with four technical replicates each. Error bars represent standard deviations. Additionally, the relative light intensities (RLU/OD) where bioluminescence is normalized by cell density are represented. Please click here to view a larger version of this figure.
Figure 7: Comparison of bioluminescent bacteria to evaluate potential quorum sensing regulation. Light emission and cell density are measured every 10 min for 10 h and represent mean values of three biological replicates with four technical replicates each. Error bars represent standard deviations.Measurements of Photobacterium mandapamensis TH1 (black squares), Vibrio harveyi 14126 (grey circles) and Photobacterium mandapamensis S1 (grey diamonds) were compared to each other; (A) depicts the optical density (OD) at 650 nm, (B) the light intensity (bioluminescence [counts/s]), and (C) relative light intensities (RLU/OD). Please click here to view a larger version of this figure.
Figure 8: Bioluminescence in liquid media and on agar plates. (A) 5 L flask with 2 L LB medium inoculated with E. coli BL21 cells expressing the pET28a lux operon plasmid photographed in light. (B) The same culture as in (A) photographed in the dark. Pictures A and B were taken approximately 2 h after induction of expression. (C) Artificial sea water medium agar plate with streaked culture of P. mandapamensis S1 photographed in the dark. Please click here to view a larger version of this figure.
The construction of an expression plasmid containing four fragments composing the whole lux-rib operon of P. mandapamensis 27561 was achieved via Gibson cloning. This E. coli based lux gene expression enables E. coli cells to emit light. Avoiding quorum sensing regulation and non-standard growth conditions are substantial advantages of this system.
The advantages of using Gibson cloning strategy are the easy assembly of multiple linear DNA fragments, high flexibility and no need for specific restriction sites18,19,20. This method allows to easily change a lux operon, excluding single genes or gene clusters or introducing new genes or exchanging genes from one strain with another. A prerequisite for the application of this method is the availability of the respective lux operon gene sequence. Only for a small number of bioluminescent bacteria is the complete DNA sequence of the respective lux operon known and/or available. Many of these sequences are fragmented because they were generated using shotgun sequencing. In the case of the investigated P. mandapamensis 27561 the complete DNA sequence of the lux operon is known and available from the NCBI gene database (GenBank: DQ988878.2).
One critical step in the protocol of the Gibson assembly is the calculation of the DNA concentration of the single fragments. In the assembly protocol of the manufacturer it was recommended to use 0.2 – 0.5 pmols and a total volume of 20 µL for 4 – 6 fragments20,21. In our case, where luxCDABFEG-ribEBH is comprised of 4 fragments, the concentrations and total volumes were 0.1 pmol and 45 µL, respectively, depending on the yield of PCR products. On the one hand, the concentration had to be reduced and on the other hand, the volume had to be increased. Nevertheless, the assembly worked very well and DNA sequencing confirmed the correct insertion at the first attempt. This finding confirmed Gibson assembly as a robust and appropriate method for our investigations, which can easily be modified18,19,20.
The newly established plate reader assay is an easy to handle method. It enables a simple primary analysis of new or (un-)known bioluminescent bacterial strains and gives already a first hint on the regulatory mechanism of light production (e.g., lag in luminescence at low cell densities). Additionally, growth conditions in combination with light production can easily be evaluated by simply changing growth medium or temperature.
The measurements with the plate reader were performed at 28 °C. The reason for this unusual setting is the temperature sensitivity of bioluminescent bacterial strains, where temperatures above 30 °C lead to less or even no growth and/or light emission. Note, that the plate reader is capable of keeping a defined temperature over time with the limitation of a missing active cooling system. Therefore, the ambient temperature has to be below the temperature of the measurement.
As a proof of concept, the comparison of the E. coli construct with the bioluminescent strain P. mandapamensis (Figure 5) on the one hand and the reference measurements (Figure 4) on the other hand were performed and confirm the reliability of this newly established system. Additionally, the long-term measurement assured the longevity of the light emission (Figure 6). But one has to consider that OD values are not reliable above a certain optical density, depending on the characteristics of the used measurement device (approximately 15 h in the present case) where an appropriate dilution would be needed for a measurement in the linear range of the detector. These high variances in OD values make these long time measurements not reliable. Therefore, shorter measurements such as 10 h are recommended using the experimental setup reported here.
Limitations of the established plate reader assay can be seen in Figure 7. The difficulty is to find an appropriate setting of the measurement. The 'gain value' adjusts the sensitivity of the photo multiplier tube (PMT). The gain is the amplification of the signal in the PMT, meaning that a higher gain factor will increase the signal. If the gain is set too low, the signal to noise ratio becomes bigger and light intensities of "low" shining bioluminescent bacteria cannot be measured any more (signals close to zero, data not shown). The challenge in a bioluminescent assay is to set the gain so the measurement results for all bacterial strains stay within the range of the instrument. Additionally, the measurement range for luminescence depends on the measurement interval time (e.g., maximum of 2,000,000 for 1 s).
The gain was set to 2800, which was empirically tested and chosen for the specific plate reader used for the establishment of this method. The used gain setting allows the recording of maximum emitted light by the bioluminescent E. coli system, P. mandapamensis 27561, and P. mandapamensis S1 without an overflow, but for the strains P. mandapamensis TH1 and V. harveyi 14126 the gain was too high. Therefore, these latter strains exceed the detection limit and the real maximal light intensity cannot be measured. This technical limitation might prevent the comparison of bioluminescent bacteria, which show high variations in maximum light emission, although growth conditions and cell densities might be comparable.
Positioning of the analyzed bacterial strains within the used well plates has to be evaluated empirically. Although black well plates with glass bottoms were used, crosstalk between the samples was observed. The light intensity of specific strains is so high, that all neighboring wells will show false positive light emissions (e.g., blank). Therefore, it is important to measure two different strains either separately or with a certain spatial separation to each other.
There are already many modified E. coli strains known that contain parts of the lux operon and are mainly application-oriented15,16,17. The methods described here, aim at fundamental research, for example the possibility of analyzing each lux gene separately. Although research of bioluminescence has a long history, there are still many open questions. By excluding or introducing genes from the lux operon, exchanging the luxAB genes with genes from another strain, or analyzing protein complexes, embedded in the easy to handle E. coli system and further application of the plate reader assay, it might be possible to gain more information on regulatory processes and the functions of lux genes.
The authors have nothing to disclose.
We want to thank Wladislaw Maier (BMG Labtech GmbH) for his support in establishing the self-written script for the plate reader. This work was supported by the Austrian "Fonds zur Förderung der wissenschaftlichen Forschung" (FWF) to PM (P24189) and the PhD program "DK Molecular Enzymology" (W901) to PM.
NEBuilder High-Fidelity DNA Assembly Cloning Kit | New England Biolabs Inc. | E2621S | for 10 rxn dx.doi.org/10.17504/protocols.io.cwaxad |
Phusion Polymerase | Thermo Scientific | F530S | |
Q5 High Fidelity DNA Polymerase | New England Biolabs Inc. | M0491S | |
GeneJet Genomic DNA Purififcation Kit | Thermo Scientific | K0721 | for 50 rxn |
Restriction enzymes and buffer (NcoI, XhoI) | New England Biolabs Inc. | R3193S/R0146S | |
Wizard SV Gel and PCR Clean-Up kit | Promega | A9282 | for 250 rxn |
Monarch DNA Gel Extraction Kit | New England Biolabs Inc. | #T1020S | for 50 rxn |
GeneJet Plasmid Miniprep Kit | Thermo Scientific | K0503 | for 250 rxn |
GoTaq G2 DNA Polymerase | Promega | M7841 | |
24-well black sensoplate with glass bottom | Greiner Bio One | 662892 | |
FLUOStar Omega plate reader | BMG Labtech | ||
OPTIMA/Mars Analysis Software | BMG Labtech | Version 2.20 | |
Microsoft Excel 2010 | Microsoft | ||
Multitron Standard Incubator Shaker | Infors AG |