In this protocol, the synthesis of Cd-free InP/ZnS quantum dots (QDs) is detailed. InP-based QDs are gaining popularity due to the toxicity of Cd2+ ions that may be released through nanoparticle degradation. After synthesis, QDs are solubilized in water using an amphiphilic polymer for use in biomedical applications.
Fluorescent nanocrystals, specifically quantum dots, have been a useful tool for many biomedical applications. For successful use in biological systems, quantum dots should be highly fluorescent and small/monodisperse in size. While commonly used cadmium-based quantum dots possess these qualities, they are potentially toxic due to the possible release of Cd2+ ions through nanoparticle degradation. Indium-based quantum dots, specifically InP/ZnS, have recently been explored as a viable alternative to cadmium-based quantum dots due to their relatively similar fluorescence characteristics and size. The synthesis presented here uses standard hot-injection techniques for effective nanoparticle growth; however, nanoparticle properties such as size, emission wavelength, and emission intensity can drastically change due to small changes in the reaction conditions. Therefore, reaction conditions such temperature, reaction duration, and precursor concentration should be maintained precisely to yield reproducible products. Because quantum dots are not inherently soluble in aqueous solutions, they must also undergo surface modification to impart solubility in water. In this protocol, an amphiphilic polymer is used to interact with both hydrophobic ligands on the quantum dot surface and bulk solvent water molecules. Here, a detailed protocol is provided for the synthesis of highly fluorescent InP/ZnS quantum dots that are suitable for use in biomedical applications.
Quantum dots (QDs) are semiconducting nanocrystals that exhibit fluorescent properties when irradiated with light1. Due to their small size (2-5 nm), which is similar to many larger biomolecules, and ease of biofunctionalization, QDs are an extremely attractive tool for biomedical applications. They have found use in biological labeling, single-molecule live-cell imaging, drug delivery, in vivo imaging, pathogen detection, and cell tracking, among many other uses2-8.
Cd-based QDs have been most commonly used in biomedical applications because of their intense fluorescence and narrow emission peak widths9. However, concerns have been raised due to potential toxicity of Cd2+ ions10 that may be released through degradation of the nanoparticle. Recently, InP-based QDs have been explored as an alternative to Cd-based QDs because they maintain many fluorescence characteristics of Cd-based QDs and may be more biocompatible11. Cd-based QDs have been found to be significantly more toxic than InP-based QDs in in vitro assays at concentrations as low as 10 pM, after only 48 hr11.
The fluorescence emission color of QDs is size-tunable1. That is, as the size of the QD increases, the fluorescence emission is red-shifted. The size and size dispersity of the QD products can be modified by changing the temperature, reaction duration, or precursor concentration conditions during the reaction12. While the emission peak of InP QDs is typically broader and less intense than Cd-based QDs, InP QDs can be made in a large variety of colors designed to avoid spectral overlap, and are sufficiently intense for most biomedical applications12. The synthesis detailed in this protocol yields QDs with a red emission peak centered at 600 nm.
Several steps are taken after synthesis of the QD cores to maintain the optical integrity of the QDs and to make them compatible for biological applications. The surface of the QD core must be protected from oxidation or surface defects that may cause quenching; therefore, a ZnS shell is coated over the core to produce InP/ZnS (core/shell) QDs13. This coating has been shown to protect the photoluminescence of the QD product. The presence of zinc ions during InP QD synthesis has been shown to limit surface defects, as well as decrease size distribution12. Even with the presence of Zn2+ in the reaction medium, synthesis of InZnP are highly unlikely12. After coating, resulting InP/ZnS QDs are coated in hydrophobic ligands such as trioctylphosphine oxide (TOPO) or oleylamine12,14. An amphiphilic polymer can interact with hydrophobic ligands on the QD surface as well as bulk water molecules to impart water solubility15. Amphiphilic polymers with carboxylate chemical groups can be used as "chemical handles" to further functionalize the QDs.
This protocol details the synthesis and functionalization of water-soluble InP/ZnS QDs with very intense fluorescence emission and relatively small size-dispersity. These QDs are potentially less toxic than commonly used CdSe/ZnS QDs. Herein, the synthesis of InP/ZnS QDs provides a practical alternative to Cd-based QDs for biomedical applications.
1. Synthesis of Indium Phosphide/Zinc Sulfide (InP/ZnS) Quantum Dots
2. Water Solubilization of InP/ZnS Quantum Dots Using an Amphiphilic Polymer
The uncoated InP cores do not demonstrate substantial visible fluorescence by eye. However, InP/ZnS (core/shell) quantum dots appear to fluoresce brightly by eye under UV irradiation. The fluorescence of InP/ZnS QDs was characterized using fluorescence spectroscopy. The fluorescence spectrum of QDs in hexanes (Figure 1) excited at 533 nm demonstrates one major peak centered at 600 nm with a full width at half maximum (FWHM) of 73 nm. While absorbance (0.2) offset in Figure 1 could imply QDs scattering light, and thus the presence of aggregated QDs, blinking analysis (vide infra) indicate that most QDs are single, or very small groups, of QDs. After coating with the amphiphilic polymer PMAL-d, the quantum yield of InP/ZnS QDs was investigated by comparing the integrated fluorescence intensity of the QDs with Rhodamine B as a standard17. The quantum yield of QDs in hexanes was determined to be 7.96% on average (2 measurements, 7.69% and 8.22%) and 6.03% in water on average (2 measurements, 5.98% and 6.08%).
The size of water-soluble InP/ZnS QDs was characterized using both transmission electron microscopy (TEM) and dynamic light scattering (DLS). TEM images, which only visualize the nanocrystal core and shell (InP/ZnS), not organic ligands on the surface, were captured at a nominal magnification of 150,000X. The images were analyzed using Fiji ImageJ18 and the threshold was adjusted to give binary images. The minimum and maximum Feret's diameters were averaged to determine the diameters of these water-soluble QDs. This data demonstrated small, relatively monodisperse QDs with an average diameter of 2.74 ± 0.72 nm (Figures 2A & B). The effective hydrodynamic diameter of the QDs in water at pH 7, encapsulated in PMAL-d, was measured from using DLS. It should be noted that the effective hydrodynamic diameter via DLS measures the solvated QD, including organic ligands and polymers on the surface of the QD, as well as water molecules that interact with them. Therefore, DLS measurements are generally much larger than measurements obtained in TEM experiments. In this measurement, QDs were assumed to be spherical and a total of 30 measurements were captured to calculate the effective diameter by volume using BIC Partial Solutions software. These values were averaged, providing an average diameter of 14.8 ± 6.0 nm (Figure 2C).
In order to determine if the synthesized InP/ZnS QDs were suitable for single-molecule imaging, blinking analysis was performed using epifluorescence microscopy8. While it is not possible to see individual QDs using light microscopy, the analysis of "on" and "off" fluorescence emission states can be used to identify single QDs puncta in fluorescence images. A puncta representing a single blinking quantum dot exhibits an "on" state that is differentiated from the "off" state. A movie of blinking QDs (diluted to approximately 100 pM in deionized water) was captured using a 63X, 1.4 NA, oil-immersion objective fitted onto an epifluorescence microscope with an appropriate filter cube and CCD camera. Images were captured with 30 msec exposure consecutively for 500 frames. Blinking analysis was performed by analyzing the average intensity of a single puncta (approximately 4 pixels) in each frame using ImageJ19 (Figure 3A). The distinct gap in between the "on" and "off" states of our QDs show their potential for single-molecule imaging (Figure 3B).
The interaction of the InP/ZnS QDs with cells was also investigated through both toxicity and cellular internalization. For both studies, mouse neuroblastoma (N2a) cells were used and all experiments were carried out in cellular medium (50/50 D-MEM/Opti-MEM supplemented with 10% fetal bovine serum and antibiotic/antimycotic). A trypan blue toxicity assay20 was performed by incubating N2a cells for 24 and 48 hr with varying concentrations of QDs. The results demonstrate negligible toxicity of N2a cells at QD concentrations between 1-5 nM (Figure 4). To observe QD internalization, N2a cells were incubated with water-soluble InP/ZnS QDs for 12 hr at both 5 and 10 nM. Images of cells incubated with these QDs appears to demonstrate a lysosomal localization of QDs after 12 hr (Figure 5), which is consistent with other internalization results of nanoparticles21.
Figure 1. Absorbance and Fluorescence Characterization of InP/ZnS QDs. Absorbance and corrected fluorescence emission spectra of InP/ZnS in hexanes excited at 533 nm, showing a maximum absorbance at 600 nm and a FWHM of 73 nm. Please click here to view a larger version of this figure.
Figure 2. Size Analysis of Polymer-coated InP/ZnS QDs in Water. (A) Transmission electron micrograph of InP/ZnS QDs dissolved in water (scale bar = 50 nm). (B) Particle size distribution histogram of TEM results with an average diameter of 2.74 ± 0.72 nm. (C) Dynamic light scattering analysis of InP/ZnS QDs in water, showing an average hydrodynamic diameter of 14.8 ± 6.0 nm. Please click here to view a larger version of this figure.
Figure 3. Blinking Analysis of InP/ZnS QDs. Single fluorescent puncta analysis detailing the presence of distinct "on" and "off" states through (A) a blinking profile of InP/ZnS QDs in water using 460 nm ± 25 nm excitation filter, 500 nm long pass emission filter, and 475 nm dichroic mirror, and (B) a histogram exhibiting the bimodal distribution of pixel intensity from one QD blinking profile. Please click here to view a larger version of this figure.
Figure 4. Trypan Blue Toxicity Assay of N2a Cells Treated with InP/ZnS QDs. Graph depicting the viability of N2a cells after incubation with InP/ZnS QDs for 24 (black) or 48 hr (red) with 1 – 25 nM QDs. Negligible toxicity is observed below 5 nM. Error bars are based on standard deviation of viability in 3 different measurements. Please click here to view a larger version of this figure.
Figure 5. Internalization of InP/ZnS QDs in N2a cells. Fluorescence micrograph showing the internalization of InP/ZnS QDs after 12 hr of incubation with 0 nM control (A) DIC (B) QD, and (C) overlay, after 12 hr of incubation with 5 nM QDs (D) DIC (E) QD, and (F) overlay, and after 12 hr of incubation with 10 nM QDs (G) DIC (H) QD, and (I) overlay. Scale bar = 10 μm. Please click here to view a larger version of this figure.
This protocol details the synthesis of highly fluorescent InP/ZnS QDs that can be used in many biological systems. The QD products synthesized here exhibited a single fluorescence emission peak centered at 600 nm with a FWHM of 73 nm (Figure 1), which is comparable to other previously described syntheses12. Reaction time and reaction temperature are extremely crucial steps due to their profound effect on QD synthesis quality and repeatability. After solubilization in water, the QDs were determined to have a quantum yield of approximately 6%. Variation of the reaction time, temperature, or precursor concentration allows the tuning of QD size and emission wavelength, which may be used in multi-spectral applications.
Size and surface charge are extremely important factors to consider when using nanoparticles in biological systems. To minimize disturbance of target biomolecules, QDs should maintain a small, monodisperse size. Additionally, the surface charge of QDs in solution can be modified to decrease nonspecific binding towards unintended targets. The synthesis of QDs presented here produced QDs with a diameter of 2.74 ± 0.72 nm by TEM (only the core and shell are visible) (Figures 2A and 2B). Water-soluble QDs were found to have an effective hydrodynamic diameter of 14.8 ± 6.0 nm, which is comparable to Cd-based QDs currently used for biological studies22. The surface charge and functionality of aqueous QDs can be modified by further reaction of the carboxylate chemical groups of the amphiphilic polymer.
Blinking analysis was used to explore the suitability of these InP/ZnS for single-molecule imaging studies. Since it is not possible to visualize individual QDs using light microscopy, the blinking of individual QDs can be used to identify single particles. This blinking phenomenon is the alternation between of discrete "on" and "off" fluorescence states23, which can be investigated using the average pixel intensity of single fluorescent QD puncta over time. The fluorescence traces of InP/ZnS QD puncta demonstrate characteristic "on" and "off" states (Figure 3A). Moreover, there is no overlap between the "on" and "off" states of a single puncta (Figure 3B), which has been used in previous studies to distinguish single particles8.
Further experiments were used to explore the suitability of these InP/ZnS QDs for cellular studies. A trypan blue toxicity assay was performed to assess the biocompatibility of the InP/ZnS QDs. After incubation for 24 hours up to 48 hr at QD concentrations ranging from 1-5 nM, negligible toxicity was observed (Figure 4), which is comparable to toxicity studies for InP/ZnS QDs11. Substantial toxicity was not observed below 25 nM; this concentration is much higher than required for many biomedical applications. For example, single-molecule imaging studies often require pM concentrations of the QD probe to label a representative number of surface-bound cellular receptors24. Additionally, N2a cells incubated with QDs at 5 nM or 10 nM for 12 hr in cellular media indicate that QDs are internalized via endocytosis, i.e., QDs demonstrate a punctate staining pattern within the cells (Figure 5). These results indicate the suitability of these InP/ZnS QDs for investigating cellular processes.
This protocol details the synthesis and functionalization of water soluble InP/ZnS QDs with intense fluorescence emission, relatively small size-dispersity, and biological compatibility. The high quality of these QD products is indicated by the visualization of single QDs in fluorescence microscopy, which demonstrates that they are suitable for single-molecule imaging. It is anticipated that these Cd-free QDs are potentially much less toxic to the biological systems studied, as well as the researchers studying them. As such, the use of these In-based QDs for biomedical applications is a prudent alternative to Cd-based QDs.
The authors have nothing to disclose.
The authors gratefully acknowledge the Department of Chemistry and the Graduate College at Missouri State University for their support of this project. We also acknowledge the Electron Microscopy Laboratory at the Frederick National Laboratory for Cancer Research for use of their transmission electron microscope and carbon-coated grids.
Oleylamine | Acros | 129540010 | |
Zinc (II) chloride | Sigma | 030-003-00-2 | |
Indium (III) chloride | Chem-Impex | 24560 | |
Tris(dimethylamino)phosphine | Encompass | 50-901-10500 | |
1-dodecanethiol | Acros | 117625000 | |
Hexanes | Fisher Sci | H292-4 | |
Acetone | TransChemical | UN 1090 | |
Zinc Stearate | Aldrich Chem | 307564-1KG | |
Tetrahydrofuran | Acros | 34845-0010 | |
Molecular Water | Fisher Sci | BP2470-1 | |
Poly(maleic anhyrdride-alt-1-tetradecene), 3-(dimethylamino)-1-propylamine derivative | Sigma | 90771-1G | |
Boric acid | Fisher Sci | BP168-500 | |
Sodium Tetraborate Decahydrate | Fisher Sci | BP175-500 | |
Rhodamine B | Aldrich Chem | R95-3 | |
Nitrogen gas | Airgas | UN1066 | |
Trypan blue | Thermo Sci | SV30084.01 | |
3 mL plastic Luer-lock syringe | BD | 309657 | |
Luer-lock Needle | Air-Tite | 8300014471 | 4 inch, 22 gauge |
50 mL polypropyene centrifuge tube | Falcon | 352098 | |
250 mL centrifuge bottle | Thermo Sci | 05-562-23 | Nalgene PPCO |
5 mL centrifuge tubes | Argos-Tech | T2076 | |
1.5 mL microcentrifuge tubes | Bio Plas | 4150 | |
0.1 μm Syringe filter | Whatman | 6786-1301 | Puradisc 13 mm nylon filter |
Slide-A-Lyzer MINI Dialysis Unit | Thermo Sci | 69590 | 20,000 MWCO |
Rotary Evaporator | Heidolph | ||
Centrifuge 5072 | Eppendorf | Swinging Bucket with 50 mL tube adapters | |
Lambda 650 UV/VIS Spectrometer | Perkin Elmer | UV-Vis Spectrophotometer | |
LS 55 Fluorescence Spectrometer | Perkin Elmer | Fluorometer | |
Axio Observer.A1 | Zeiss | epifluorescence microscope | |
AxioCam MRm | Zeiss | CCD Camera | |
Tecnai TF20 Microscope | FEI | Transmisison Electron Miscroscope | |
TEM Eagle CCD | FEI | TEM CCD Camera | |
NanoBrook Omni DLS | Brookhaven | Dynamic Light Scattering Instrument |